• Title/Summary/Keyword: TEST-1

Search Result 59,887, Processing Time 0.071 seconds

IEEE 1500 Wrapper and Test Control for Low-Cost SoC Test (저비용 SoC 테스트를 위한 IEEE 1500 래퍼 및 테스트 제어)

  • Yi, Hyun-Bean;Kim, Jin-Kyu;Jung, Tae-Jin;Park, Sung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.65-73
    • /
    • 2007
  • This paper introduces design-for-test (DFT) techniques for low-cost system-on-chip (SoC) test. We present a Scan-Test method that controls IEEE 1500 wrapper thorough IEEE 1149.1 SoC TAP (Test Access Port) and design an at-speed test clock generator for delay fault test. Test cost can be reduced by using small number of test interface pins and on-chip test clock generator because we can use low-price automated test equipments (ATE). Experimental results evaluate the efficiency of the proposed method and show that the delay fault test of different cores running at different clocks test can be simultaneously achieved.

A Study on Composing the Structural Test Equipment of Large Scale Beam Type Test Specimen to Load Multiple Point and Capacity (대형 보형 실험체의 다점 다하중 가력을 위한 실험장치 구성에 관한 연구)

  • Park, Dong Su;Lee, Kyung Jin;Ham, Kyung Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.189-197
    • /
    • 2011
  • In the field of structural test, it is a very important factor to apply with an appropriate test jig to enhance test accuracy and efficiency. Especially in the large scale structure test, proper test apparatus scheme will reduce overall cost and time of the test project. Actuators, oil jack and UTM is generally used to evaluate the flexural capacity of the test beam. But in the case of multiple loading point or asymmetric loading of large scale test specimen, existing test method such as UTM have a difficulty in giving an accurate load. In this study new test method which is composed of existing test apparatus will be developed to improve test accuracy and economic efficiency.

The Method of Reinforcing the Immunity of Residual Current Circuit Breaker for the EMC Composite Surge (누전차단기의 EMC 조합서지 내성 강화를 위한 방안)

  • Kim Jae-Chul;Han Yoon-Tak;Kim Oun-Seok;Seol Kyu-Hwan;Kang Jang-Kyou;Moon Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.8
    • /
    • pp.322-328
    • /
    • 2006
  • In this paper, The impulse un-tripping characteristics and the electro magnetic compatibility characteristics are compared with each other. The performance of impulse un-tripping test exists at domestic standard (KSC 4613). However test items are insufficient because the more test items such as EMC exist at international standard (IEC). Also, Electric Appliances Safety Certificate has taken the certificate test since July 2004 in Korea but did not confirm the EMC performance for RCCBs made in Korea. Thus, in this paper, We experiment with Oscillatory waves immunity test and the 7 EMC tests for 32 RCCBs of 4 types (mini, home standard, plug, outlet) for 16 brands according to IEC standard 61009-1 and 61008-1. As a result, 24 RCCBs proved to be poor for surge immunity test. However the RCCBs operating incorrectly for surge immunity test operate correctly for oscillatory waves immunity test. Thus, the correlation between oscillatory waves immunity test and EMC test is little and standard for compatibility of combination surge at IEC 61000-4-5 should be added to KS standard as soon as possible.

A Study on the Validity of 'Hepa-S' Hepatitis B Antibody Detecting Reagent after Vaccination of 'Hepa-Vax' (B형 간염백신 'Hepa-Vax' 접종후 항체검사시약 'Hepa-S' kit의 정확도에 관한 연구)

  • Moon, In-Sook
    • Journal of Preventive Medicine and Public Health
    • /
    • v.18 no.1
    • /
    • pp.51-57
    • /
    • 1985
  • To attempt to measure the effect of domestic product P.H.A. kit 'Hepa-S' after completion of 'Hepa-Vax' vaccination schedule, P.H.A. test and R.I.A. test on the 330 healthy adults were carried out. The results obtained were as follow ; 1. The positive anti HBs rate after completion of 'Hepa-Vax' vaccination were; in P.H.A. test with domestic product P.H.A. kit 81.2%, in P.H.A. test with foreign product P.H.A. kit 82.7%, and in R.I.A. test 95.8% 2. Using the result of R.I.A. test as the standard, sensitivity of P.H.A. test with domestic product P.H.A. kit was 84.8% and specificity was 100.0% 3. Using the result of R.I.A. test as standard, sensitivity of P.H.A. test with foreign P.H.A. kit was 86.4% and specificity was 100.0%. 4. The concordance rate of P.H.A. test with domestic product and foreign product kit was 98.5%. On the result of this study, there was no significant difference in the validity between the domestic product P.H.A. kit 'Hepa-S' and the foreign P.H.A. kit $'Hebsgencell^{TM}'$. So that it is recommendable to use domestic product P.H.A. kit instead of foreign product P.H.A. kit.

  • PDF

Studies on serological tests for pullorum disease (추백리의 혈청학적 진단법에 관한 연구)

  • 김정태;심항섭;김태종;고태오;우종태;유기승;박유순
    • Korean Journal of Veterinary Service
    • /
    • v.21 no.3
    • /
    • pp.313-323
    • /
    • 1998
  • In order to establish a sensitive and specific diagnostic method for detection of antibody to Salmonella pullorum, a enzyme-linked immunosorbent assay(ELISA) was designed and standardized. The diagnostic efficacy of the established ELISA was compared with that of the serum plate agglutination test and immunodiffusion test for pullorum disease. 1. The chicken hyperimmune sera to Salmonella pullorum, S gallinarum, S typhimurium and S typhi were shown the cross reaction to S pullorum antigen by serum plate agglutination test. 2. When compared the cross reaction titer of microplate agglutination test for chickens hyperimmune sera, it was found that the titer were 64 in S pullorum, 32 in S gallinarum, 4 in S typhimurium and 8 in S typhi, respectively. 3. When compared the specificity of various antigen(HA, EA, PA and SA) by the immunodiffusion test, the most suitable antigen was phenol-treated bactrium. 4. The optimal concentration of S pullorum antigen for ELISA was 1 : 160 dilution of bacterium. 5. The efficacy of the ELISA for detection of S pullorum antibody was compared with serum Plate agglutination test and immunodiffusion test in chickens infected with S pullorum. The antibody was first detected at 6 days after infection using three tests examined. The antibody was alldetected at 9 days by ELISA, at 12 days by serumplate agglutination test, at 15 days by immunodiffusion test.

  • PDF

Direct and indirect methods for determination of mode I fracture toughness using PFC2D

  • Sarfarazi, Vahab;Haeri, Hadi;Shemirani, Alireza Bagher
    • Computers and Concrete
    • /
    • v.20 no.1
    • /
    • pp.39-47
    • /
    • 2017
  • In this paper, mode I fracture toughness of rock was determined by direct and indirect methods using Particle Flow Code simulation. Direct methods are compaction tension (CT) test and hollow centre cracked quadratic sample (HCCQS). Indirect methods are notched Brazilian disk (NBD) specimen, the semi-circular bend (SCB) specimen, hollow centre cracked disc (HCCD), the single edge-notched round bar in bending (SENRBB) specimen and edge notched disk (END). It was determined that which one of indirect fracture toughness values is close to direct one. For this purpose, initially calibration of PFC was undertaken with respect to data obtained from Brazilian laboratory tests to ensure the conformity of the simulated numerical models response. Furthermore, the simulated models in five introduced indirect tests were cross checked with the results from direct tests. By using numerical testing, the failure process was visually observed. Discrete element simulations demonstrated that the macro fractures in models are caused by microscopic tensile breakages on large numbers of bonded discs. Mode I fracture toughness of rock in direct test was less than other tests results. Fracture toughness resulted from semi-circular bend specimen test was close to direct test results. Therefore semi-circular bend specimen can be a proper test for determination of Mode I fracture toughness of rock in absence of direct test.

A Study of The Refraction at Video Display Terminal (VDT를 이용한 굴절검사에 대한 연구)

  • Lee, Hak Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.49-53
    • /
    • 2000
  • Comparing to an Image test chart which printed from computer. Hahn's standard test chart and Chart project test chart propose to make the program of an image test chart in computer. Test type of the test chart should be programed by difference size which was examined Hangul program of Hangul & Computer Co. An image test of visual acuity most decreased among 3 kinds of testing. Testing of Fixation disparity was same between Diplopia test and chart project test chart, so that. Design of test chart could be programed diverse by Hangul program of Hangul & Computer Co.

  • PDF

The Effects of Perfectionism and Cognitive-Emotion Regulation Strategies on Test Anxiety (완벽주의와 인지적 정서조절 전략이 시험불안에 미치는 영향)

  • Jung, A-Hyun;Kang, Min Ju
    • Korean Journal of Child Studies
    • /
    • v.35 no.1
    • /
    • pp.61-76
    • /
    • 2014
  • This study examined the effects of perfectionism and cognitive-emotion regulation strategies on the test anxiety. The participants in this study were 423(227 boys, 196 girls) 6th graders recruited from four elementary schools in Seoul, Korea. The participants completed the Test Anxiety Inventory-Korea(Kim, 1991), the Child and Adolescent Perfectionism Scale(CAPS; Flett at al, 2000), and the Cognitive-Emotion Regulation Questionnaire(CERQ; Garnefski, 2001). The results of this study were as follows. First, self-oriented perfectionism and socially prescribed perfectionism were both positively associated with test anxiety. Additionally, the children who used more adaptive cognitive-emotion regulation strategies reported lower test anxiety, whereas the children who used more maladaptive cognitive-emotion regulation strategies reported higher test anxiety. Secondly, there was an interactional effect between self-oriented perfectionism and maladaptive cognitive-emotion regulation strategies on test anxiety. Lastly, socially prescribed perfectionism and cognitive-emotion regulation strategies had a significant effect on children's test anxiety. However, there were no interactional effects observed between socially prescribed perfectionism and cognitive-emotion regulation strategies on test anxiety.

BIST implemetation with test points insertion (테스트 포인트 삽입에 의한 내장형 자체 테스트 구현)

  • 장윤석;이정한김동욱
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.1069-1072
    • /
    • 1998
  • Recently the development of design and automation technology and manufacturing method, has reduced the cost of chip, but it becomes more difficult to test IC chip because test technique doesn't keep up with these techniques. In case of IC testing, obtaining test vectors to be able to detect good chip or bad one is very important, but according to increasing complexity, it is very complex and difficult. Another problem is that during testing, there could be capability of physical and electrical damage on chip. Also there is difficulty in synchronization between CUT (circuit under test) and Test equipment〔1〕. Because of these difficulties, built in self test has been proposed. Not only obtaining test vectors but also reducing test time becomes hot issues nowadays. This paper presents a new test BIST(built in self test) method. Proposed BIST implementation reduces test time and obtains high fault coverage. By searching internal nodes in which are inserted test_point_cells〔2〕and allocating TPG(test pattern generation) stages, test length becomes much shorter.

  • PDF

An Overview of Flight Test Planning and Test Results for the Development of Korean Utility Helicopter (한국형 기동헬기 개발을 위한 비행시험 계획 및 시험결과 개요)

  • Kwon, Hyuk-Jun;Park, Jaeyoung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.268-276
    • /
    • 2013
  • The objective of this paper is to give a general understanding for the development flight test of Korean Utility Helicopter(KUH). This paper contains the contents of detailed flight test plan, the type of flight test, an introduction to main flight test area, and the overview of flight test results. At the beginning, more than 8,500 test points were identified for airworthiness certification to show the compliance for the KUH development requirements. However, the number of flight test points were optimized to 7,800 at the end. To accomplish the test objectives, about 860 flight test sorties had been performed, and more than 1,000 test sorties were consumed for trouble shooting. This paper also describes some major issues faced during development flight test phase.