• Title/Summary/Keyword: TEST-1

Search Result 60,001, Processing Time 0.066 seconds

Study on Real-Time Load Simulator for Testing Propulsion Inverter Test (추진인버터 시험을 위한 실시간 부하 시뮬레이터에 관한 연구)

  • 김길동;신정렬;이우동;한석윤;박기준
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • A newly-built inverter has to undergo a series of stress tests in the final stage of production line. This can be achieved by connecting it to a dynamometer consisting of a three-phase machine joined by a rigid shaft to a DC load machine. The latter is controlled to create some specific load characteristic needed for the test. In this paper a test method is proposed, in which no mechanical equipment is needed. The suggested test stand consists only of a inverter to be tested and a simulator converter. Both devices are connected back-to-back on the AC-side via smoothing reactors. The simulator operates in real-time as an equivalent load circuit, so that the device under test will only notice the behaviour of a three-phase machine under consideration of the load. In oder to prove rightness of the suggested test method, the simulation and actural experiment carried out emulation for a 2.2kW induction motor.

A Review of Structural Testing Methods for ASIC based AI Accelerators

  • Umair, Saeed;Irfan Ali, Tunio;Majid, Hussain;Fayaz Ahmed, Memon;Ayaz Ahmed, Hoshu;Ghulam, Hussain
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.1
    • /
    • pp.103-111
    • /
    • 2023
  • Implementing conventional DFT solution for arrays of DNN accelerators having large number of processing elements (PEs), without considering architectural characteristics of PEs may incur overwhelming test overheads. Recent DFT based techniques have utilized the homogeneity and dataflow of arrays at PE-level and Core-level for obtaining reduction in; test pattern volume, test time, test power and ATPG runtime. This paper reviews these contemporary test solutions for ASIC based DNN accelerators. Mainly, the proposed test architectures, pattern application method with their objectives are reviewed. It is observed that exploitation of architectural characteristic such as homogeneity and dataflow of PEs/ arrays results in reduced test overheads.

Performance Test Circuit for a Valve of MMC Based HVDC Power Converter (MMC 기반 HVDC 전력변환기의 밸브 성능 시험회로)

  • Chi-Hwan Bae;Kwang-Rae Jo;Hak-Soo Kim;Eui-Cheol Nho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.76-81
    • /
    • 2023
  • A new test circuit for an MMC-based valve HVDC power converter is proposed. The proposed scheme satisfies the required clauses from IEC-62501. The valve test current contains second harmonic component and DC offset as well as a fundamental component that is quite similar to the real operating arm current of MMC based HVDC power system. The structure of the proposed test circuit is simple compared to conventional test circuits. Furthermore, the power supply voltage rating of the proposed test circuit is reduced dramatically around 20% of the conventional scheme with the same current rating. The validity of the proposed test circuit is verified through simulation and experimental results.

PMSM Propulsion Control System Development and Test for Rolling Stock (철도 차량용 PMSM 추진제어시스템 개발 및 시험)

  • Ro, Ae-Sook;Kim, Tae-Yun;Chung, Eun-Sung;Han, Jeong-Soo;Lee, Jang-Moo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1845-1850
    • /
    • 2011
  • Permanent Magnet Synchronous Motor(PM motor) of Advanced EMU is the direct drive morot(DDM) without using reduction gear and Interior buried Permanent Magnet Synchronous Motor(IPMSM). Propulsion system for IPMSM control is composed 1C1M. 1C1M is good for each motor control and anti slip/slide. Propulsion control system have completed running test on field and reliability test is in progress.

  • PDF

TTA 시험$\cdot$인증서비스 - 소프트웨어 분야 -

  • 김혜경
    • TTA Journal
    • /
    • s.86
    • /
    • pp.89-93
    • /
    • 2003
  • TTA(한국정보통신기술협회)는 2003년 2월 28일, 품질인증 제품으로 ㈜하나디에스디의''라이프에듀빌더 v 1.0'', ㈜연성정보기술의''이메일플러스 v 3.0'', ㈜포스정보의''책꽂이KDC v 3.1'', ㈜켈코인의''챌린저 웹진 웹스쿨 v 3.0'' 등 4개의 제품에 대하여 Good Software 마크를 발급하였다. 그리고 2003년 3월 10일에 VeriTest-TTA 인증제품으로 (주)스페이스 인터내셔널의''CD Tower v 3.1''은 VeriTest-TTA Good Quality, Optimized Performance & Internationalized 마크를, ㈜포스데이터의''BizBinder v 1.0''은 VeriTest-TTA Good Quality & Optimized Performance 인증마크를 발급하였다. 본 고에서는 상위의 인증 획득한 제품에 대하여 소개하고자 한다.

  • PDF

Performance Test and Evaluation of the Urban Transit Maglev (도시형 자기부상열차의 성능시험 및 평가)

  • 김국진;박계서;김남해;조흥제
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.485-493
    • /
    • 1998
  • The EMS/LIM driven system, called UTM-01 has been under development for LRT type urban transit applications. At the present time, the 1st vehicle of UTM-01 (a two vehicle system) is undergoing various tests on the 1.1km test track at the KIMM premises in Taejon. This paper describes the design, characteristics and test results of the Levitation /Guidance, the Propulsion/Braking System and the Leakage Flux for 1st vehicle of UTM-01.

  • PDF

Dynamic Response of Unreinforced Masonry Building (비보강 조적조의 동적 거동)

  • Kim, Nam-Hee;Kim, Jae-Kwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.5 s.39
    • /
    • pp.1-14
    • /
    • 2004
  • The seismic behavior of a 1/3-scale model of a two-story unreinforced masonry (URM) structure typically used in constructing low-rise residential buildings in Korea is studied through a shaking table test. The purposes of this study are to investigate seismic behavior and damage patterns of the URM structure that was not engineered against seismic loading and to provide its experimental test results. The test structure was symmetric about the transverse axis but asymmetric to some degrees about longitudinal axis and had a relatively strong diaphragm of concrete slab. The test structure was subjected to a series of differentlevels of earthquake shakings that were applied along the longitudinal direction. The measured dynamic response of the test structure was analyzed in terms of various global parameters (i.e., floor accelerations, base shear, floor displacements and storydrift, and torsional displacements) and correlated with the input table motion. Moreover, different levels of seismic performance were suggested for performance-based design approach. The results of the shaking table test revealed that the shear failure was dominant on a weak side of the 1stfloor while the upper part of the test model remained as a rigid body. Also, it was found that substantial strength and deformation capacity existed after cracking.

Algorithms for Detecting Coupling Faults in Semiconductor RAM's (반도체 RAM의 결합고장을 검출하는 알고리듬)

  • 여정모;조상복
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.1
    • /
    • pp.51-63
    • /
    • 1993
  • "Algorithm DA" is proposed to test linked 2-CFs(2-Coupling Faults) with order 2 or 3 which are not perfectly detected in conventional algorithms. "Test 1*", "Test 2*" and "Algorithm RA" are proposed restricted 3-CFS. The time complexity of "Test 1*" is reduced in view of the detection of 3-CFS. "Test 2*" and "Algorithm RA" have not only the reduces time complexity but also the improved fault coverage in comparison with conventional algorithms. And "Algorithm RA" can be applied step by step according to the degree of the fault coverage. If "Algorithm RA" is applied to the memory with parallel test. its time complexity is reduced considerably. It is proved that the MT(March Test) with nonlinear address sequences can not detect perfectly the CFs more complex than linked 2-CFs with order 3.ss sequences can not detect perfectly the CFs more complex than linked 2-CFs with order 3.

  • PDF

Rapid Bioassay Technique Based on Temperature Control of Ceriodaphnia dubia (Ceriodaphnia dubia의 온도조절에 근거한 단기급성독성 조사법)

  • PARK Jong Ho;LEE Sang Ill;CHO Young Oak;LEE Won Ho;YEON Ik Jun;CHO Kyu Seok
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.3
    • /
    • pp.209-214
    • /
    • 2004
  • A method for rapid acute toxicity test based on temperature control of Ceriodaphnia dubia has been developed and evaluated. A new toxicity test based on temperature control (TTBTC) which are based on temperature control, was developed and compared for the adsorption of the better methodology for short-term toxicity screening. Initially, daphnid larval are exposed to toxicants and at the same time the temperature of the water bath containing media is increased to high temperature $(35.5^{\circ}C).$ After 1.25 hrs of contact time, the number of the daphnids, either living (no toxic effect) or dead (toxic effect), is counted by the naked eyes. Effect of exposure time on test sensitivity was not significantly different between 1 to 1.5 hr. Comparison of the rapid 1.25 hr acute toxicity test developed in this study and the standard 48 hr acute toxicity test using heavy metals, cyanide and pentachlorophenol indicated that the 1.25 hour test provides an acceptable level of sensitivity in toxicity test for C. dubia.

The Quantitative Analysis by Digital Subtraction Radiography on the Effect of Platelet Rich Plasma Combined with Synthetic Bone Graft on Grade II Furcation Involvement (2급 치근 이개부 치료 시 합성골 이식 및 혈소판 농축 혈장의 골재생 효과에 대한 디지털 공제술의 정량적 분석)

  • Oh, Ji-Soo;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.2
    • /
    • pp.465-475
    • /
    • 2001
  • The purpose of this study was to evaluate effect of platelet rich plasma on the treatment of Grade II furcation involvement, with and without porous resorbable calcium carbonate($Biocoral^{(R)}$)in humans by digital subtraction radiography. 15 teeth(control group) were treated with porous resorbable calcium carbonate($Biocoral^{\(R)}$), and 15 teeth(test group) were treated with porous resorbable calcium carbonate($Biocoral^{(R)}$) and Platelet Rich Plasma. The change of bone density was assessed by digital subtraction radiography in this study. The change of mineral content by as much as 5%(vol) could be perceived in the subtracted images. The change of mineral content was assessed in the method that two radiographs are put into computer program to be overlapped and the previous image is subtracted by the later one. Both groups were statistically analyzed by Wilcoxon signed Ranks Test and Mann-whitney Test using SPSS program(5% significance level). The results were as follows: 1. In test group, the radiolucency in 3 months after surgry were significantly increased than 1 month after surgery(p<0.05). 2. In test group, there were no significant difference between 1 month after surgery and 6 months after surgery(p>0.05). 3. In test group, the radiopacity in 6 months after surgery were significantly increased than 3 months after surgery(p<0.05). 4. In control group, the radiolucency in 3 months and 6 months after surgery were significantly increased than 1 month after surgery(p<0.05). 5. In control group, the radiopacity in 6 months after surgery were significantly increased than 3 months after surgery(p<0.05). 6. There were no significant difference between test group and control group at 1 month, 3 months after surgery, but radiopacity in test group were significantly increased than control group at 6 months after surgery(p<0.05). In conclusion, Platelet Rich Plasma can enhance bone density.

  • PDF