• Title/Summary/Keyword: TEST-1

Search Result 59,887, Processing Time 0.07 seconds

Test of Independence in a Markov Dependent Waiting-time Distribution

  • Bai, Do-Sun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.1 no.1
    • /
    • pp.99-103
    • /
    • 1975
  • A procedure for the test of independence of the observations and the null distribution are studied for a waiting-time distribution of the number of Bernoulli trials required to obtain a preassigned number of successes under Markov dependence. Selected critical values for the test statistic are tabulated.

  • PDF

Axial Load Transfer Behavior of a Large Diameter Drilled Shaft by Osterberg Type Load Test (오스트버그식 재하시험을 이용한 대구경 현장타설말뚝의 축하중전이거동)

  • 임태경;정창규;정성민;최용규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.447-454
    • /
    • 2003
  • In this test, two separated oil jacks were placed at bottom of drilled shaft(D = 1,500mm, L = 33m), and maximum upward and downward load of 1,250 tonf was applied. Also, the deformable rod sensors were placed on each level, and axial strains at each level were measured. Because the side skin friction and the end bearing could be measured separately in the Osterberg type pile load test, this test might be more economical and more applicable than a conventional static pile load test. Thus, if this Osterberg type pile load test could be established during design stage, construction cost might be reduced and its application for large diameter pile could be enhance greatly.

  • PDF

Three-phase Making Test Method for Common Type Circuit Breaker

  • Ryu, Jung-Hyeon;Choi, Ike-Sun;Kim, Kern-Joong
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.5
    • /
    • pp.778-783
    • /
    • 2012
  • The synthetic short-circuit making test to adequately stress the circuit breaker has been specified as the mandatory test duty in the IEC 62271-100. The purpose of this test is to give the maximum pre-arcing energy during making operation. And this requires the making operation with symmetrical short-circuit current that is established when the breakdown between contact gap occurs near the crest of the applied voltage. Also, if the interrupting chamber of circuit breakers is designed as the type of common enclosure or the operation is made by the gang operated mechanism that three-phase contacts are operated by one common mechanism, three-phase synthetic making test is basically required. Therefore, several testing laboratories have developed and proposed their own test circuits to properly evaluate the breaker performance. With these technical backgrounds, we have developed the new alternative three-phase making circuit.

Development of Low Cost Flight Test Equipment by Using Bang-pai Kite (방패연을 이용한 저비용 비행시험장치 개발)

  • Park, Jongseo;Kim, Bonggyun;Lee, Sangchul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.25 no.3
    • /
    • pp.68-73
    • /
    • 2017
  • In this study, we design a low-cost test equipment for real-time image observation and transmission/reception distance test using 1m by 1.5m bang-pai kite. The image observation is made by using two servo motors to enable the camera to control the two axis attitude. The image observation equipment is hung on the string of a kite and the test is performed to observe the real time image. The transmission and reception distance test of the wireless RF transceiver module is conducted on the ground and in the air.

Inlet Distortion Test of Gas Turbine Engine (가스터빈 엔진의 입구 유동 왜속 시험)

  • Lee, Jinkun;Lee, Kyungjae;Kho, Sunghee;Kwak, Jae Su
    • Journal of Aerospace System Engineering
    • /
    • v.1 no.1
    • /
    • pp.53-59
    • /
    • 2007
  • Inlet distortion test was performed at Korea Aerospace Research Institute in order to evaluate the degradation of engine performance under the distorted inlet condition. In this paper, only the inlet pressure distortion was taken into consideration. During the development process of the inlet distortion test technique, variable distortion screen was designed and evaluated under various test conditions to establish the experimental database of distortion for engine test. The result of inlet distortion test for engine shows that the operating point was changed toward the worse direction and the degradation of engine performance by inlet distortion was verified.

  • PDF

TRH Stimulation Tests Compared with $T_3$ Suppression Tests in Patients With Marginal Hyperthyroidism (경도(輕度) 갑상선기능항진증환자(甲狀腺機能亢進症患者)에서 TRH 자극시험(刺戟試驗)과 $T_3$ 억제시험(抑制試驗)과의 비교연구(比較硏究))

  • Choi, Sung-Jae;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.14 no.1
    • /
    • pp.17-21
    • /
    • 1980
  • TRH stimulation tests and $T_3$ suppression tests were done in 13 patients with clinically suspected mild or early hyperthyroidism who were all conventional thyroid function tests gave results within the accepted normal range. The results were as follows 1. 6 patients with normal $T_3$ suppression test revealed normal TRH stimulation test and could be easily diagnosed as euthyroidism. 2. 7 patients with abnormal $T_3$ suppression test exhibited no TSH response to TRH stimulation test and could be easily diagnosed as hyperthyroidism. The TRH stimulation test is a single, sensitive and reliable test of thyroid function and can well replace $T_3$ suppression test in the diagnosis of marginal hyperthyroidism.

  • PDF

Fabrication of Test Socket from BeCu Metal Sheet (BeCu 금속박판을 이용한 테스트 소켓 제작)

  • Kim, Bong-Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.34-38
    • /
    • 2012
  • We have developed a cost effective test socket for ball grid array(BGA) integrated circuit(IC) packages using BeCu metal sheet as a test probe. The BeCu furnishes the best combination of electrical conductivity and corrosion resistance. The probe of the test socket was designed with a BeCu cantilever. The cantilever was designed with a length of 450 ${\mu}m$, a width of 200 ${\mu}m$, a thickness of 10 ${\mu}m$, and a pitch of 650 ${\mu}m$ for $11{\times}11$ BGA. The fabrication of the test socket used techniques such as through-silicon-via filling, bonding silicon wafer and BeCu metal sheet with dry film resist(DFR). The test socket is applicable for BGA IC chip.

A Test for Spherical Symmetry (구형 대칭성 검정에 대한 연구)

  • Park Cheolyong
    • The Korean Journal of Applied Statistics
    • /
    • v.18 no.1
    • /
    • pp.99-113
    • /
    • 2005
  • In this article, we propose a chi-squared test of spherical symmetry. The advantage of this test is that the test statistic and its asymptotic p-value are easy to compute. The limiting distribution of the test statistic is derived under spherical symmetry and its accuracy, in finite samples, is studied via simulation. Also, a simulation study is conducted in which the power of our test is compared with those of other tests for spherical symmetry in various alternative distributions. Finally, an illustrative example of application to a real data is provided.

Prediction of Ship Maneuverability by Circular Motion Test (Circular Motion Test를 이용한 선박의 조종성능 추정에 관한 연구)

  • Shin, Hyun-Kyoung;Jung, Jae-Hwan;Lee, Ho-Young
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.46 no.3
    • /
    • pp.259-267
    • /
    • 2009
  • Recently, ship maneuverability has been very important issue due to accidents of frequent occurrence at sea. IMO standards for ship maneuverability were applied from January 1, 2004. In this study, maneuverability model tests were considered through a 2m-class KVLCC1 in the Ocean Engineering Wide Tank at University of Ulsan(UOU). Circular Motion Test(CMT) was performed to obtain the maneuvering coefficients by using X-Y Carriage. The trajectories simulated using the coefficients are compared with those of PMM test and free running test.

Analysis of Insulation Condition in Traction Motor Stator Windings (견인전동기 고정자 권선의 절연상태 분석)

  • Kim, Hee-Dong;Park, Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.7
    • /
    • pp.631-635
    • /
    • 2007
  • Diagnostic, surge and ac breakdown tests are widely used to evaluate the insulation condition of stator winding in traction motor. Diagnostic test included ac current, tan delta and maximum partial discharge. The result of diagnostic test indicates that five kinds of stator windings are good condition. Surge test was peformed to confirm the healthy of turn insulation in stator windings. This test is very easy to detect the turn insulation failure between normal and defect stator windings. After completing the diagnostic test, ac breakdown test has conducted gradually increasing ac voltage, until the stator winding punctured. No. 5 stator windings failed near rated voltage of 18.9 kV The breakdown voltage of No. 1 stator windings was 13.0 kV The ac breakdown voltage of normal winding is about 1.45 times higher than that of defect windings. The failure was located in a line-end coil at the exit from the core slot.