• Title/Summary/Keyword: TEQ

Search Result 119, Processing Time 0.019 seconds

Comparison of Dioxin Analytical Results Between SP-2331 and DB-5MS Capillary Columns in the HRGC/HRMS Analysis (HRGC/HRMS에 SP-2331 및 DB-5MS 컬럼 사용시 다이옥신 결과의 비교)

  • Hong, Jongki;Yang, Jeong-Soo;Shin, Jung-Hwa;Ahn, Yun-Gyong;Lee, Dai-Woon
    • Analytical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.184-191
    • /
    • 2004
  • In this study, the separation of toxic dioxin 2,3,7,8-congeners by DB-5MS and SP-2331 GC columns which are widely used in HRGC/HRMS analysis was examined. Through the dioxin analysis of column performance check standard solution and fly ash sample, the isomer specific separation of 2,3,7,8-substituted dioxins from tetra to hexa-isomers on DB-5MS and SP-2331 columns were studied. The effect of I-TEQ value by these columns was also studied. The total concentrations of toxic dioxins for the column performance check standard solution were 508.4 ng/mL analyzed by DB-5MS and 515.8 ng/mL analyzed by SP-2331, respectively. The I-TEQ value obtained by both columns was shown to be almost equivalent for the column performance check standard solution and fly ash sample.

Contamination level and congener profiles of PCBs, Co-PCBs and PCDD/DFs in transformer insulation oil samples (변압기 절연유 중 PCBs, Co-PCBs 및 PCDD/PCDFs 오염수준 및 이성체 분포)

  • Kim, Kyoung-Soo;Kim, Jong-Guk;Shin, Sun-Kyoung;Kim, Kyoung-Sim;Song, Byung-Joo
    • Analytical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.263-271
    • /
    • 2006
  • The levels of total PCBs, Co-PCBs and PCDD/Fs in the transformer insulation oil samples obtained using GC/ECD and HRGC/HRMS were ranged from N.D. to 77.3 ppm, from 0.0863 to 2.49 ppm and from N.D. to 0.00241 ppm, respectively. In terms of WHO-TEQ values, Co-PCBs and PCDD/Fs were ranged from 23.3 to 600 pgTEQ/g and from N.D. to 128 pgTEQ/g, respectively (${\Sigma}Co$-PCBs+PCDD/Fs concentration was calculated 24.4~728 pgTEQ/g). Although, the contribution of PCDD/Fs was below 12% in total TEQ concentration, it is suggested contamination of PCDD/Fs in transformer insulation oils. Among 10 samples, 4 samples showed higher concentration than 2 ppm (specific waste criterion of Korea) and Aroclor 1242, 1248, 1254 and 1260 was detected in samples as a single or mixture of Aroclor. It was shown reliable relationship between concentration of Co-PCBs and those of PCDD/Fs (p<0.003), however, was not shown between production year of transformer and concentration of PCBs. The distribution pattern of Co-PCB congeners showed that the ratios of mono-ortho substituted congeners were higher than non-ortho substituted congeners. Among that, PCB-118 congener was predominant. In addition, the OCDD congener was predominated in PCDD/Fs congeners as above 53%. Moreover, the congener pattern of Co-PCBs was similar to that of Aroclor as well as ambient air, which suggested that PCBs volatilization from transformer insulation oil affected the pattern of Co-PCBs in ambient air.

Distribution of Persistent Organic Pollutants(POPs) in Sediment and Organism Collected from Various Culturing Grounds, Korea (국내 양식어장 퇴적물과 생물 중 잔류성유기오염물질 분포)

  • baek, Seung-Hong;Lee, In-Seok;Kim, Hye-Seon;Choi, Minkyu;Hwang, Dong-Woon;Kim, Sook-Yang;Choi, Hee-Gu
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.17 no.4
    • /
    • pp.262-269
    • /
    • 2012
  • We investigated the concentration levels and evaluated the distributions of 17 polychlorinated dibenzo-p-dioxins and furans(PCDD/Fs), 12 dioxin-like polychlorinated biphenyls(DLPCBs) and 24 polybrominated diphenyl ethers (PBDEs) in sediment and organism from various culturing grounds in Korean coast. The levels of PCDD/Fs, DLPCBs, and PBDEs in sediment samples ranged from 0.03 to 2.9(Mean${\pm}$SD, $1.2{\pm}0.89$) pg $WHO_{2005}$-TEQ $g^{-1}$ dry weight(dw), ND(not detected) to 1.1($0.09{\pm}0.19$) pg $WHO_{2005}$-TEQ $g^{-1}$ dw, and ND to 16.6($2.96{\pm}3.53$) ng $g^{-1}$ dw, respectively. Also, the levels of PCDD/Fs, DLPCBs, and PBDEs in culturing organisms ranged from ND to 0.24($0.07{\pm}0.06$) pg $WHO_{2005}$-TEQ $g^{-1}$ wet weight(ww), ND to 0.11($0.04{\pm}0.04$) pg $WHO_{2005}$-TEQ $g^{-1}$ ww, and 0.05 to 0.29($0.13{\pm}0.06$) ng $g^{-1}$ ww, respectively. The levels of total dioxins(PCDD/Fs+DLPCBs) and PBDEs in sediments from East and South sea were four to seven times higher than those from West sea. PCDD/Fs had dominant contribution(mean, 94%) for TEQ concentration in sediment, whereas relatively higher contribution of DLPCBs(33%) were shown in culturing organism than sediment. BDE209 was a dominant congener in both matrix. The concentrations of PCDD/Fs, DLPCBs and PBDEs were in decreasing trends in Korea coasts compared to previous results.

Characteristics of organic pollutants in discharged industrial waste in Korea - Focuse on metallic and plastic manufacturing processes and wastewater treatment plants - (국내 사업장 폐기물 중 유기오염물질의 배출특성 연구 - 금속과 플라스틱 제조공정 및 폐수처리시설 중심으로 -)

  • Yeon, Jin-Mo;Kang, Young-Yeul;Kim, Woo-Il;Shin, Sun-Kyoung;Jeong, Seong-Kyeong;Cho, Yoon-A;Kim, Na;Kim, Min-Sun
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.421-428
    • /
    • 2012
  • In this study, PCDD/PCDFs, PAHs and PCBs in wastes from metal, plastic and wastewater treatment facilities were analyzed. The concentrations of PCDD/PCDFs ranged from 7.37~432.20 ng-TEQ/kg in fly ash, 0.51~855.01 ng-TEQ/kg in incinerated ash and 0.37~385.81 ng-TEQ/kg in dust. Dioxin content was lower, compared to data in foreign countries. PAHs concentration was in the range of 0.0075~2.9225 mg/kg for process sludge and 0.0035~1.6716 mg/kg for wastewater sludge, which satisfied all of the two standards (Nap, Ant, B(a)F:4/0.8, Phen, B(a)A:5/1, Flt:10/2.5, B(a)P:4.5/0.9) of the Marine Environment Management Act. PAHs concentration in process sludge and wastewater sludge were slightly lower than those abroad. According to the analysis of seven types of PCBs (in comparison with the first standard, 0.15 mg/kg), concentration was found in the range of 0.0~0.65 mg/kg, while PCB-52, PCB-101, PCB-138, PCB-153 and PCB-180 isomers were detected in excessive value in some machine oil and hydraulic fluid.

A Study on the PCDDs/PCDFs Contents in the Flue Gas of Muncipal Solid Waste Incinerator(III) -Emission Concentration Varying the Combustion Temperature- (쓰레기소각로 배출가스의 PCDDs/PCDFs 함유량에 관한 연구(III) -소각로 연소 온도변화에 따른 보일러 후단에서의 배출 농도 변화-)

  • Shin, S.K.;Chung, Y.H.;Lee, J.I.
    • Analytical Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.540-549
    • /
    • 1999
  • The combustion temperature was controlled between $880^{\circ}C$ to $1070^{\circ}C$ to find the relation the combustion temperature and emission amount of PCDDs/PCDFs in the Municipal solid waste incinerator. The emission amount of PCDDs/PCDFs decreased when the temperature increased in the rear of the boiler. The PCDDs/PCDFs concentration were detected $7.82ng-TEQ/Nm^3$ at $880^{\circ}C$, $6.97ng-TEQ/Nm^3$ at $970^{\circ}C$ and $6.13ng-TEQ/Nm^3$ at $1070^{\circ}C$. Also, The chlorophenols, chlorobenzenes, and PCB concentration decreased by increasing the temperature from $880^{\circ}C$ to at $1070^{\circ}C$, and the isomer of the prescsors had a tendency to emit the higbly cbiorinated compounds.

  • PDF

Distribution and Source Identification of PCDD/Fs and Co-PCBs in Sediments from the Geum River (금강 수계 퇴적물 중 PCDD/Fs 및 Co-PCBs의 농도 분포와 발생원 해석)

  • Park, Jong-Eun;Kim, Jong-Guk;Ahn, Sung-Yun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.12
    • /
    • pp.900-906
    • /
    • 2011
  • To investigate concentration and sources of PCDD/Fs and Co-PCBs in sediments, total 52 sediment samples were measured at 17 sites in Geum River. As a result of analysis, total concentrations of PCDD/Fs and Co-PCBs were ranged from not detected (N.D.)~193.47 pg/g-d.w. (mean value: 84.52 pg/g-d.w) and 0.34~359.19 pg/g-d.w (mean value: 114.65 pg/g-d.w.) respectively. Also, toxic equivalent (TEQ) concentration of PCDD/Fs and Co-PCBs were ranged from N.D.~5.12 (mean value: 0.88) pg I-TEQ/g-d.w and N.D.~0.58 (mean value: 0.09) $WHO_{2005}$-TEQ pg/g-d.w. respectively. The upstream indicate the highest concentration and as it goes to the downstream, it has tendency to decrease. Higher chlorinated compounds were dominant in most of site which detected PCDD/Fs. Occurrence of Co-PCBs isomer patterns appear similar to each sampling site was found. The isomer patterns showed similar between sediment and PCB products. The principal component analysis also showed that the samples contained the characteristics of PCBs products.

Annual Variation and Gas/Particie Partitioning of PCDD/DFs of Ambient Air at Busan, Korea (부산의 대기 중 PCDD/DFs의 연간 변화와 가스/입자상 분배)

  • Ok, Gon;Park, No-Jin;Hwang, Sung-Min;Lee, Seok-Hyung;Kim, Jee-Hoon;Kim, Sung-Yong
    • Journal of Environmental Science International
    • /
    • v.19 no.4
    • /
    • pp.447-457
    • /
    • 2010
  • This study aims to monitor the variation of concentration of PCDD/DFs between the gaseous phase-particulate phases in the ambient air of urban area in Korea. This monitoring is evaluated by using the Junge-Pankow model and the Koa absorption model with the application of the Octanol-air partition coefficient. In this study, the ambient air samples were analyzed according to each congener group of the PCDD/DFs by HRGC/HRMS, which have been investigated for the past 5 years. In the results, the annual variation in the concentration level of $\Sigma$PCDD/DFs in TSP was increased from $1588\;fg/m^3$ in 1998 to $5123\;fg/m^3$ in 2002, and from 31 fg I-TEQ/$m^3$ to 94 fg I-TEQ/$m^3$ in the $\Sigma$I-TEQ. In the case of PUF of gaseous phase sample, their variation was increased from $1615\;fg/m^3$ in 1998 to $2237\;fg/m^3$ in 2002, and in the $\Sigma$I-TEQ from 12 fg I-TEQ/$m^3$ to 17 fg I-TEQ/$m^3$. The relative coefficient between the gas phase concentration of PCDD/DFs and the temperature was a value of 0.744; the contributive rate of the temperature to the gaseous phase concentration was 0.554. According to the results, the pattern of the coefficient of distribution based on log $p_L^0$ is similar to the ambient air of the urban areas.

Certification and Quality Control of the Official Test Facilities of Dioxins in Korea (국내 다이옥신 측정분석기관 지정 및 정도관리)

  • Jang, Seong-Ki;Kim, Tae-Seung;Lee, Won-Seok;Chung, Young-Hee;Choi, Doug-Il
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.675-682
    • /
    • 2000
  • The concentration of dioxins from flue gases of municipal waste incineration facilities with capacities over 50 tons/day are regulated by the guideline: $0.1ng-TEQ/Nm^3$ for new facilities, and $0.5ng-TEQ/Nm^3$ for existing facilities and it will be strengthened to $0.1ng-TEQ/Nm^3$ until 2003 year. Dioxins from these incineration facilities have to be measured more than 2 times annually by the Official Test Facilities of Dioxins. Seven institutions have been certified so far as the Official Test Facilities of Dioxins. These facilities have to be evaluated by the quality control program provided by National Institute of Environmental Research every year. We reported the results of quality control test performed in 1999. Four institutions certified in 1998 sampled flue gases at stack of M incineration facilitiy and analyzed dioxins by Official Methods of Air Pollution. The isokinetic coefficients, the parameter for evaluation of sampling ability were excellent for all four institutions. They were 100.9%, 102.4%, 102.1% and 99.2%, respectively. The criteria required are as follows; resolution over 10,000, mass calibration within ${\pm}5ppm$, ion abundance ratio within 15%, and the recovery of 50-120%. As results, those institutions also met these parameters of Official Method of Air Pollution.

  • PDF

Analysis of 2,3,7,8-substituted PCDDs, PCDFs, and DL-PCBs in muscle of crucian carp (Carassius auratus and Carassius cuvieri) from major rivers and lakes (주요 하천 및 호수에 서식하는 붕어 (Carassius auratus and Carassius cuvieri) 근육에 축적된 2,3,7,8-치환 PCDDs, PCDFs 및 DL-PCBs 분석)

  • Jeong, Gi-Ho;Moon, Ji-Yong;Moon, Dong-Ho
    • Analytical Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.484-492
    • /
    • 2011
  • Bioaccumulation status and distribution characteristics of PCDDs, PCDFs and DL-PCBs in cruian carp collected from the four representative sites of major river systems in Korea were investigated. The recovery rates of PCDDs and PCDFs ranged from 50.6% to 88.3%, and those of DL-PCBs ranged from 52.3% to 93.2%. The mean, median and concentration range of ${\sum}$dioxins, which represents the total concentratons of PCDDs, PCDFs and DL-PCBs accumulated in the muscle of crucian carp, were 0.39, 0.14 and 0.047-1.0 pg TEQ/g wet wt., respectively. DL-PCBs were detected above the detection limit from all the samples, whereas PCDDs and PCDFs were detected from limited crucian samples. The relative contribution of DL-PCBs to ${\sum}$dioxins was remarkably larger than those for PCDDs and PCDFs. The percent contribution was 83.6% for DL-PCBs, and followed by 12.7% and 3.7% for PCDFs and PCDDs, respectively.

Analysis of Toxic-PCBs in Sediment by Isotope Dilution HRGC/HRMS (Isotope Dilution HRGC/HRMS 방법을 이용한 저니토중 Toxic-PCBs 분석)

  • Jang, Seong-Ki;Choi, Duk-Il;Park, Sun-Ku;Kim, Kyung-Sup
    • Analytical Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.550-557
    • /
    • 1999
  • This Analysis was conducted for 13 toxic-PCBs having TEF value among 209 PCBs isomers in sediment by isotope dilution HRGC/HRMS method. From the result, the recovery of surrogate standard was in the range of 71~99%. The concentration range for 13 toxic-PCBs in sediment was found to be 0.84~2.49 ng/g, among them the concentration levels of 2,2',3,3',4,4',5-HpCB(IUPAC No. 170) and 2,2',3,4,4',5,5'-HpCB(IUPAC No. 180) represented almost 50% of total concentrarion and that of 2,3,4,4,5-PeCB(IUPAC No. 114) showed over 10%. The TEQ concentration levelwas in the range of 0.38~2.63 pg-TEQ/g and 3,3',4,4',5-PeCB(IUPAC No. 126) concentration represented over 50% of total TEQ concentration.

  • PDF