• Title/Summary/Keyword: TEMP

Search Result 385, Processing Time 0.026 seconds

Analysis of the Effect of Fog Cooling during Daytime and Heat Pump Cooling at Night on Greenhouse Environment and Planst in Summer (하절기 주간 포그 냉방과 야간 히트펌프 냉방이 온실 환경 및 작물에 미치는 영향 분석)

  • Lee, Taeseok;Kim, Jingu;Park, Seokho;Lee, Choungkeun
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.328-334
    • /
    • 2021
  • This study was conducted to analyze the effect of fog cooling during daytime and heatpump cooling at night in greenhouses in summer. During daytime, the average temp. and RH of the control greenhouse which had shading screen were 32.1℃ and 59.4%. and the average temp. and RH of the test greenhouse which had fog cooling were 30.0℃ and 74.3%. At this time, the average outside temp. and RH were 31.4℃ and 57.7%. So, the temp. of the control was 0.7℃ higher than outside temp., but the temp. of the test was 1.4℃ lower than outside and 2.1℃ lower than control. The average RH was 74.3% in the test and 59.4% in control. The average temp. and RH of the control greenhouse which had natural ventilation at night were 25.2℃ and 85.1%, and the average temp. and RH of the test greenhouse which had heat pump cooling were 23.4℃, 82.4%. The average outside temp. and RH at night were 24.4℃ and 88.2%. The temp. of the control was 0.8℃ higher than outside temp., but the temp. of the test was 1.0℃ lower than outside and 1.8℃ lower than control. The average RH was 82.4% in test and 85.1% in control greenhouse. There was no significant difference between the plants growth eight weeks after planting. But after the cooling treatment, the values of stem diameter, plant height, chlorophyll in test were higher than control. The total yield was 81.3kg in test, 73.8kg in control, so yield of test was 10.2% higher than control. As a result of economic analysis, 142,166 won in profits occurred in control greenhouse, but 28,727 won in losses occurred in test greenhouse, indicating that cooling treatment was less economical.

Effect of Storage Period and Temperature on the Characteristics Related with Rice Quality (벼 저장온도 및 저장기간이 미질 관련 형질에 미치는 영향)

  • Ha, Ki-Yong;Park, Hong-Kyu;Ko, Jae-Kwon;Kim, Chung-Kon;Choi, Yoon-Hee;Kim, Ki-Young;Kim, Young-Doo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.51 no.spc1
    • /
    • pp.25-29
    • /
    • 2006
  • This study was carried out to investigate physiochemical properties and factors related with eating quality in the rice and paddy rice with different storage methods. As storage period was longer and temperature was higher, the b values of chromaticity and degree of fatty acid were increased, and the b value of room temp. was higher than that of low temp. In the varieties, the b value of Samcheonbyeo was the highest among varieties. also b value of Gancheokbyeo and Sae-gyehwabyeo were more increased than those of Dongjinbyeo and Hojinbyeo. Toyo meter values were significantly different according to storage temperature and period. Toyo meter values in storage of low temp. small decreased from 8 month after storages and that of loom temp. was severe decreased from 2 month after storages. In storage of low temp, Toyo meter values in storage of low temp. $(5{\sim}10^{\circ}C)$ was the lowest, and those of the early varieties were the most decreased. Degree of fatty acid of brown rice was increased from 2 month after storages and those of low temp. was severe increased. So, they made rice quality and eating quality to be deteriorated.

A STUDY FOR SETTING AND THERMAL EXPANSION OF DENIAL SOLDERING INVESTMENTS (납착용 매몰재의 경화팽창과 열팽창에 관한 연구)

  • Shin, Sung-Ae;Lim, Jang-Seop;Jeong, Chang-Mo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.6
    • /
    • pp.730-740
    • /
    • 1999
  • The purpose of this study was to investigate setting and thermal expansion of dental soldering investments. In order to compare expansion rates and to investigate the effect of water/powder ratio on expansion, setting and thermal expansion of low dental soldering investments were measured under three different water/powder ratio conditions. standard, 20% decreased and 20% increased. Setting expansion of investments was measured by use of dialgauge method. Each measurement was started two minutes later from the beginning of spatulation and recorded every one minute for one hour. Thermal expansion of cylindrical test specimens, 10mm diameter, 50mm length, was recorded in a thermodilatometer at heating rate of $10^{\circ}C$ per minute from $25^{\circ}C\;to\;700^{\circ}C$. The results of this study were obtained as follows: 1. Setting expansion rates under the standard water/powder ratio condition were 0.198% in Speed-E, 0.090% in Deguvest, 0.080% in CM and Hi-temp. Setting expansion of Speed-E was significantly different from those of CM, Deguvest and Hi-temp, and setting expansion of Deguvest was significantly different from those of CM and Hi-temp(p<.05). 2. Under the decreased water/powder ratio condition, there was significant increase in setting expansion of 4 dental soldering investments (p<.05). 3. There were no significant differences in setting expansions of investments except Hi-temp between standard and increased water/powder ratio condition(p<.05). 4. Thermal expansion rates under the standard water/powder ratio condition were 1.923% in Deguvest, 1.629% in Speed-E, 1.619% in Hi-temp and 1.580% in CM. No significant differences in thermal expansions under the standard water/powder ratio condition existed only between Speed-I and Hi-temp(p<.05) 5. Under the decreased water/powder ratio condition, there was significant increase in thermal expansion of CM and Deguvest but decrease in thermal expansion of Speed-E (p<.05). 6. Under the increased water/powder ratio condition, there was significant decrease in thermal expansion of CM, Deguvest and Speed-I but decrease in thermal expansion of Hi-temp(p<.05).

  • PDF

Evaluation and Comparison with Standard 48 hr Acute Bioassay and High Temperature Rapid Toxicity Test for Sewage Toxicity Test (하수의 독성평가를 위한 표준독성시험법과 온도증가 단기독성평가법의 비교 평가)

  • Lee, Sang-Ill;Jun, Byong-Hee;Weon, Seung-Yeon;Kim, Yi-Jung;Kim, Keum-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.2
    • /
    • pp.191-197
    • /
    • 2005
  • A new method, ToxTemp (TOXcity test based on TEMPerature control) using Ceridaphnia dubia was applied to evaluate the toxicity of insecticide materials and compared with the standard 48 hr acute bioassay. BPMC, diazinon and fenitrothion may cause the inhibition to the biological process in sewage treatment plant and need to detect toxicity within short contact time. The ToxTemp method showed sensitive detection with more shorter contact of 1-1.5 hr time than that of the standard 48 hr acute bioassay. To evaluate toxicity of real wastewater/sewage, the inhibition rate of nitrification and oxygen uptake rate (OUR) using activated sludge, the standard 48hr acute bioassay and ToxTemp method using C. dubia were compared, respectively. On the basis of the inhibition rate of nitrification, the OUR test showed the less sensitive results at the relatively strong toxic sewage. On the other hands, the standard 48hr acute bioassay and ToxTemp method using C. dubia represented the toxicity of each wastewater/sewage with high sensitivity. Even the slightly low (about 1.5%) sensitivity, the ToxTemp method showed the high applicability to the real site of sewage treatment plant.

Effect of TempCore Processing on Microstructure and Mechanical Properties of 700 MPa-Grade High-Strength Seismic Resistant Reinforced Steel Bars (700 MPa급 고강도 내진 철근의 미세조직과 기계적 특성에 미치는 템프코어 공정의 영향)

  • Shin, S.H.;Kim, S.K.;Lim, H.G.;Hwang, B.
    • Transactions of Materials Processing
    • /
    • v.30 no.2
    • /
    • pp.91-98
    • /
    • 2021
  • The present study deals with the microstructure and mechanical properties of 700 MPa-grade high-strength seismic resistant reinforced steel bars fabricated by various TempCore process conditions. For the steel bars, in the surface region tempered martensite was formed by water cooling and subsequent self-tempering during TempCore process, while in the center region there was ferrite-pearlite or bainite microstructure. The steel bar fabricated by the highest water flow and the lowest equalizing temperature had the highest hardness in all regions due to the relatively fine microstructure of tempered martensite and bainite. In addition, the steel bar having finer microstructures as well as the high fraction of tempered martensite in the surface region showed the highest yield and tensile strengths. The presence of vanadium precipitates and the high fraction of ferrite contributed to the improvement of seismic resistance such as high tensile-to-yield strength ratio and high uniform elongation.

The Effect of Napping of Knitted Fabric on Wear Sensation (편성물의 기모가공이 착용감에 미치는 영향)

  • Lee Jong-Min;Lee Soon-Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.11 no.3 s.25
    • /
    • pp.41-55
    • /
    • 1987
  • The purpose of this study is to investigate the effects of napping of knitted fabric on wear sensation and physiological responses. Experimental garments were four types of warm-ups made of either $100\%$ PET or $65/35\%$ P /C and either napped or unnapped respectively. Two healthy young female adults were chosen as subjects for the experiment. Experimental room conditions were as follows: Temp., $22\pm0.5^{\circ}C$ R.H., $54\pm3\%$ and Air Velocity, 0.25m/ sec or 2. 86m/sec. The subjects exercised on bicycle ergometer and rested alternatively for totally 45-min. The results are summarized as follows. 1) With napped Warm-up, chest, back, mean skin temp. and microclimates, i.e., temp., relative humidity and water vapor pressure inside the clothing, were higher than with unnapped warm-up. And there was no difference in pulse rate between napped and unnapped warm-ups. 2) Wear sensations of thermal, humidity, tactile and comfort were 'more hot' and 'more uncomfortable' in 0.25m/sec air velocity. but in 2.86m/sec condition the tactile sensation was 'better' and 'more comfortable' with napped warm-ups. According to Pearson's Correlation, among various kinds of wear sensations, tactile is most related with comfort. From these results, it can be concluded that napped fabric decreases the rate of heat trans? mission and moisture diffusion through the clothing. Therefore skin and body temp. and temp., R.H., Vapor Pressure inside the clothing are increased.

  • PDF

COMPARISON OF RETENTIVE FORCES OF TEMPORARY CEMENTS AND ABUTMENT HEIGHT USED WITH IMPLANT-SUPPORTED PROSTHESES

  • Lee, Dong-Hee;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.280-289
    • /
    • 2008
  • STATEMENT OF THE PROBLEM: Recent data regarding the effects the cement type and abutment heights on the retentive force of a prosthetic crown are inconsistent and unable to suggest clinical guidelines. PURPOSE OF THE STUDY: This study evaluated the effects of different types of temporary cements and abutment heights on the retentive strength of cement-retained implant-supported prostheses. MATERIALS AND METHODS: Prefabricated implant abutments, 4 mm in diameter, $8^{\circ}$taper per side, and light chamfer margins, were used. The abutment heights of the implants were 4 mm, 5.5 mm and 7 mm. Seven specimens of a single crown similar to a first premolar were fabricated. Six commercially available temporary cements, TempBond, TempBond NE, Cavitec, Procem, Dycal, and IRM, were used in this study. Twenty-four hours after cementation, the retentive strengths were measured using a universal testing machine with a crosshead speed of 0.5 mm/min. The cementation procedures were repeated 3 times. The data was analyzed using two-way analysis of variance and a Tukey test (${\alpha}$=0.05). RESULTS: The tensile bond strength ranged from 1.76 kg to 19.98 kg. The lowest tensile strengths were similar in the TempBond and Cavitec agents. Dycal showed the highest tensile bond strength (P<0.01). More force was required to remove the crowns cemented to the long abutments (P<0.05). CONCLUSION: TempBond and Cavitec agents showed the lowest mean tensile bond strength. The Dycal agent showed more than double the tensile bond strength of the TempBond agent.

A study on the Durable Press finish by Wet-Fixation Process for Rayon Fabrics (II) - Effect of Treatment Temperature and Time - (레이온 직물의 Wet-Fixation에 의한 DP가공에 관한 연구(II) -처리온도 및 시간의 영향-)

  • Hu Yoon Sook;Kim Eun Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.13 no.4
    • /
    • pp.357-369
    • /
    • 1989
  • The purpose of this study was to investigate the effects of treatment temperature and time on the, of easy-care and strength properties of the wet fixation processed rayon fabrics. Viscose rayon fabrics were treated with mixed resins of melamine formaldehyde (MF) and DMDHEU by one bath and two bath wet fixation processes. The MF/DMDHEU mixed resin concentrations were 50/100, 50/150, 100/100 and 100/150(g/1). Magnasium chloride was used as a catalyst. The wet fixation conditions were 24hrs at room temperature,20 mins at $75^{\circ}C$ and 5 mins at $105^{\circ}C$ Wet fixation processed fabrics did not show the difference in the resin add-one, DP ratings and wrinkle recovery angles by the different treatment temperatures and times. DP ratings were in the order of $105^{\circ}C>75^{\circ}C>room$ temp, in one bath and two bath wet fixation. Breaking and tearing strength of one bath processed fabrics showed in the order of $75^{\circ}C>room\;temp>105^{\circ}C$ The breaking strength of two bath processed fabrics showed in the order of $105^{\circ}C>75^{\circ}C>room$ temp. Tearing strength showed in the order of $75^{\circ}c>105^{\circ}C>room$ temp. Abrasion resistances were in the order of $75^{\circ}C>105^{\circ}C>room$ temp. in one bath and two bath processes.

  • PDF

Long-Term Tropical Residency Diminishes Central Sudomotor Sensitivities in Male Subjects

  • Lee, Jeong-Beom;Bae, Jun-Sang;Shin, Young-Oh;Kang, Jong-Chul;Matsumoto, Takaaki;Toktasynovna, Aliopva Aziza;Kaimovich, Alipov Gabit;Kim, Wan-Jong;Min, Young-Ki;Yang, Hun-Mo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.11 no.6
    • /
    • pp.233-237
    • /
    • 2007
  • Tropical natives (TROP) are capable of tolerating tropical heat because of their long-term adaptation to tropical environments. When exposed to heat stress, these natives tend to respond with lower sweat output, which is generally thought to be the result of heat acclimatization. The main objective of this study was to clarify central mechanisms inherent to suppressed thermal sweating in tropical natives (Malaysians) by comparing their sweating responses to those of temperate native (TEMP) (Koreans). This experiment was conducted in a thermoneutral climatic chamber ($24{\pm}0.5^{\circ}C,\;40{\pm}3%$ relative humidity). Heat loads were applied to each subject by the immersion of their lower legs in a hot water bath ($43^{\circ}C$ for 30 min). Sweat onset-time and sweat volume were compared between TROP and TEMP. The sweat onset-times on four selected points on the body ranged from 10.25 to 13.47 min in TEMP subjects, and from 16.24 to 17.83 min in TROP subjects (p<0.001). The local sweat volumes at the same sites ranged from 4.30 to $9.74 mg/cm^2$ in TEMP subjects, and from between 1.80 to $4.40mg/cm^2$ in TROP subjects (p<0.001). These results demonstrated a significant difference between TROP and TEMP subjects with regard to the manner in which they regulate their body temperatures when exposed to heat loads, and verified that long-term thermal adaptation blunts sweating sensitivities.

Bracket bonding to polymethylmethacrylate-based materials for computer-aided design/manufacture of temporary restorations: Influence of mechanical treatment and chemical treatment with universal adhesives

  • Goracci, Cecilia;Ozcan, Mutlu;Franchi, Lorenzo;Di Bello, Giuseppe;Louca, Chris;Vichi, Alessandro
    • The korean journal of orthodontics
    • /
    • v.49 no.6
    • /
    • pp.404-412
    • /
    • 2019
  • Objective: To assess shear bond strength and failure mode (Adhesive Remnant Index, ARI) of orthodontic brackets bonded to polymethylmethacrylate (PMMA) blocks for computer-aided design/manufacture (CAD/CAM) fabrication of temporary restorations, following substrate chemical or mechanical treatment. Methods: Two types of PMMA blocks were tested: $CAD-Temp^{(R)}$ (VITA) and $Telio^{(R)}$ CAD (Ivoclar-Vivadent). The substrate was roughened with 320-grit sandpaper, simulating a fine-grit diamond bur. Two universal adhesives, Scotchbond Universal Adhesive (SU) and Assure Plus (AP), and a conventional adhesive, Transbond XT Primer (XTP; control), were used in combination with Transbond XT Paste to bond the brackets. Six experimental groups were formed: (1) $CAD-Temp^{(R)}/SU$; (2) $CAD-Temp^{(R)}/AP$; (3) $CAD-Temp^{(R)}/XTP$; (4) $Telio^{(R)}$ CAD/SU; (5) $Telio^{(R)}$ CAD/AP; (6) $Telio^{(R)}$ CAD/XTP. Shear bond strength and ARI were assessed. On 1 extra block for each PMMA-based material surfaces were roughened with 180-grit sandpaper, simulating a normal/medium-grit ($100{\mu}m$) diamond bur, and brackets were bonded. Shear bond strengths and ARI scores were compared with those of groups 3, 6. Results: On $CAD-Temp^{(R)}$ significantly higher bracket bond strengths than on $Telio^{(R)}$ CAD were recorded. With XTP significantly lower levels of adhesion were reached than using SU or AP. Roughening with a coarser bur resulted in a significant increase in adhesion. Conclusions: Bracket bonding to CAD/CAM PMMA can be promoted by grinding the substrate with a normal/medium-grit bur or by coating the intact surface with universal adhesives. With appropriate pretreatments, bracket adhesion to CAD/CAM PMMA temporary restorations can be enhanced to clinically satisfactory levels.