• Title/Summary/Keyword: TELEMETRY

Search Result 546, Processing Time 0.042 seconds

Telemetry Performance Enhancement Based on Spectral Efficient Retransmission (주파수 효율적 재전송 기반 원격측정 성능 향상)

  • Park, Chung-woon;Park, Hyo Sub
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.5
    • /
    • pp.429-436
    • /
    • 2017
  • Since the telemetry performance using the time-delayed data dissipates the wireless channel resources, we propose the spectral efficient retransmission scheme in this paper. In the proposed scheme, the telemetry data is retransmitted based on triggered memory to improve the spectral efficiency. The proposed scheme minimizes the error caused by multipath fading, antenna pattern as well as the error caused by the flight events. In the flight simulation data, we show the proposed scheme improves the telemetry performance based on spectral efficient retransmission.

Measurement and Analysis of Rodent Biological Signals using Telemetry System (원격측정장치를 이용한 설치류의 생체신호 측정 및 분석)

  • Kim, Chang-Hwan;Hur, Gyeong-Haeng
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.1159-1165
    • /
    • 2011
  • Telemetry techniques of rats have been used for assessing safety pharmacology of drugs and chemicals. Biological signals including blood pressure and heart rate measured under anesthesia were significantly different from those obtained under normal conditions. The stress of restraint in awake animals can also affect the accuracy of physiological evaluation. This paper details the surgery required to allow key cardiovascular parameters to be determined. The telemetric measurement of cardiovascular parameters such as blood pressure, heart rate, electrocardiograph(ECG) established. We carried out the continuous monitoring of cardiovascular parameters using the telemetry system in F344 rats. During the measurement, no significant changes were observed in the heart rate and blood pressure. ECG signals and body temperature were also constant during the measurement of biological signals. With the results of this study, we conclude that this telemetry system can be applied usefully for the assesment of biological parameters in the rats.

Command/Telemetry System of KOMPSAT-I (아리랑 위성의 Command/Telemetry 시스템)

  • 강수연;이종인;천이진;정창호;김진철;백홍렬
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1998.10a
    • /
    • pp.662-664
    • /
    • 1998
  • 본 논문에서는 다목적 실용위성인 아리랑위성(KOMPSAT-I)에서 지상과의통신을 위해 사용하는 CCSDS(Consultative Committee for Space Data Systems)표준 Command/Telemetry(CMD/TLM)시스템과 KOMPSAT-I의 목적에 맞게 이를 적용한 CMD/TLM 시스템을 소개한다. 현재 한국항공우주 연구소는 Observer 회원 자격으로 CCSDS 에 가입되어 있으며 국내 위성 개발에서 CMD/TLM 시스템에 CCSDS프로토콜을 사용한 것은 처음이다.

  • PDF

A Design of the Telemetry Transmitter for Monitoring Exercise Electrocardiogram (운동중의 심전도 모니터링을 위한 원격조정 송신기의 설계)

  • 권창옥;최준영
    • Journal of Biomedical Engineering Research
    • /
    • v.3 no.2
    • /
    • pp.113-118
    • /
    • 1982
  • This paper presents a frequency modulated radio-telemetry, transmitter for monitoring and transmitting an exercise electrocardiogram (ECG) and respiration activity simultaneously on single carrier frequency in the standard FM broadcast band of 88-108 MHz. We have evaluated the performance of the FM telemetry transmitter which is proposed on the basis of an exercise ECG test in the treadmill.

  • PDF

An Unscented Kalman Filter for Noisy Parameter Estimation of Passive Telemetry Sensor System

  • Kim, Kyung-Yup;Jeong, Jong-Won;Ok, Soo-Yol;Lee, Joon-Tark
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.45-46
    • /
    • 2005
  • In this paper, a passive telemetry sensor system using Unscented Kalman Filter(UKF) is proposed. Specially, to show the effective tracking performance of the UKF, we compared with the tracking performance of Recursive Least Square Estimation (RLSE) using linearization.

  • PDF

Study on the Biomedical Signal Processing System (신호처리 알고리즘을 적용한 생체신호처리 시스템에 관한 연구)

  • 박차훈;김태선
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2001.05a
    • /
    • pp.252-255
    • /
    • 2001
  • The purpose of this study is to realize the real time monitoring ECG telemetry system applied by the telemetry unit, in which transmission is made through the electronic wave and reception is made through the light, and by the wavelet algorithm as well. A light receiver via existing telemetry unit which is based on baseband, the reception length was 50cm, but when the frequency modulation is used, the reception length is extended to 3m. In addition to this, we have found that the full-duplex method of transmission became available by using dual-mechanism.

  • PDF

Link anlaysis of TTC system for LEO satellite (저궤도 위성 관제 시스템의 링크 특성 분석)

  • 장대익;이점훈;김영완;최재익
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.7
    • /
    • pp.39-47
    • /
    • 1997
  • The mission of the TTC system is to acquire and process the telemetry data from the satellite and to provide mission planning and satellite control for the target stellite system. In this paper, the transmission scheme for the Tracking, Telemetry and Command(TTC) system of satelliteis described and determined according to the recommendation of CCSDS, and the channel characteristics are analyzed according to modulation method. Expecially, we introduced the concepts of carrier vs. telemetry data power ratio which causes the channel performance to degrade, and analyzed the effects of transmission performance according to the power ratio of carrier vs. telemetry data and the modulation index. The channel of the LEO TTC sytem is different with usual satellite communication system. So, we have generalized the link budget of TTC sytem for using the link budget of ground station well-known and proposed the determination method of modultion indices for improveing channel performance.

  • PDF

RLSE Based Batteryless Telemetry Capacitive Sensor System

  • Lee, Joon-Tark;Kim, Kyung-Yup
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.318-321
    • /
    • 2003
  • In case, sensor system performs where it is difficult to access physically and it is in the poor environment, it is limited to communicate by using wire and installing power module in sensor system. In this paper, it suggests how information is obtained from telemetry sensor by means of inductive coupling without battery. Comparing with the telemetry sensor system of inductive coupling by the power supply, this system estimates the capacitance of sensor with high precision in using RLSE, not the process of modulation and demodulation. In order to activate this system, inductive model is used and in case of time variant parameter, telemetry sensor system which has got high rate in accuracy is implemented by using the forgetting factor.

  • PDF

TELEMETRY TIMING ANALYSIS FOR IMAGE RECONSTRUCTION OF KOMPSAT SPACECRAFT

  • Lee, Jin-Ho;Chang, Young-Keun
    • Journal of Astronomy and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.117-122
    • /
    • 2000
  • The KOMPSAT(Korea Multi-Purpose SATellite) has two optical imaging instruments called EOC(Electro-Optical Camera) and OSMI (Ocean Scanning Multispectral Imager). The image data of these instruments are transmitted to ground station and restored correctly after post-processing with the telemetry data transfeered from KOMPSAT spacecraft. The major timing information of the KOMPSAT is OBT (On-Board Time) which is formatted by the on-board computer of the spacecraft, based on 1Hz sync. pulse coming from the GPS receiver involved. The OBT is transmitted to ground station with the house-keeping telemetry data of the spacecraft while it is distributed to the instruments via 1553B data bus for synchronization during imaging and formatting. The timing information contained in the spacecraft telemetry data would have direct relation to the image data of the instruments, which should be well explained to get a more accurate image. This paper addresses the timing analysis of the KOMPSAT spacecraft and instruments, including the gyro data timing analysis for the correct restoration of the EOC and OSMI image data at ground station.

  • PDF

Development of Home-care Medical Information System integrating Telemetry (Telemetry를 통합한 재택 진료시스템의 개발)

  • Ham, J.H.;Chee, Y.J.;Yim, S.H.;Park, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.295-298
    • /
    • 1997
  • We developed the system that enables patients to be treated at home during their daily life through digital telemetry and public communication line. This system records and transfers ECG signals through wireless digital telemetry unhindering the patient's normal activities in long-term recording, and transmits the processed data, which enables real-time remote examination via ISDN phone line. Patient's image, voice, and transmitted signals are transferred to medical experts in remote medical center interactively.

  • PDF