• Title/Summary/Keyword: TECHNIQUE

Search Result 61,200, Processing Time 0.069 seconds

Microvascular Anastomosis Using 'Continuous Suture with Interrupted Knot' Technique (연속 봉합 단속 결찰법을 이용한 미세 혈관 문합법)

  • Choi, Moon-Su;Park, Sang-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.8 no.1
    • /
    • pp.22-27
    • /
    • 1999
  • While the conventional end-to-end anastomotic technique is accepted as 'the golden standard' for microvascular anastomosis, it is time-consuming and tedious. In an effort to offer faster and safer ways of performing microvascular anastomoses, numerous anastomotic techniques have been proposed, but further refinements in microvascular techniques are still necessary. A 'continuous suture with interrupted knot' technique was devised for faster and safer anastomosis. It has been successfully used in microanastomoses of both artery and vein for free tissue transfer. It is a combination of the interrupted suturing technique and the continuous suturing technique. First, a continuous suture is made with the size of loop decreasing in order, and then the sutures are tied individually from the first loop to the last one as in the conventional interrupted suturing technique. It was applied clinically to fourteen patients over the past ten months and found to be a highly efficient technique that satisfied our needs. This 'continuous suture with interrupted knot' technique has several advantages over other techniques : The operative time is reduced comparing conventional interrupted suture technique. By delaying the tie and with the vessel walls kept separated, the risk of through-stitch can be reduced. Tying all the sutures at one time not only speed up the procedures, but also reduced the surgeon's fatigue. In addition, it has no problem of anastomotic stenosis which is a disadvantage of continuous suture technique. This technique proved to be faster and safer, and has patency equal to that of the conventional end-to-end anastomosis. It is of great help to the surgeon in reducing operative time, especially in clinical situations when many anastomoses are required, or lengthy grafting procedures are undertaken.

  • PDF

Hypothesis Tests For Performances of a New Spline Interpolation Technique (신 스플라인보간법의 퍼포먼스 가설점정)

  • Yu, Ki-Yun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.7 no.1 s.13
    • /
    • pp.29-40
    • /
    • 1999
  • In vector GIS, natural linear entities (called linear entitles) are usually represented by a set of line segments. As an alternative of the line segments, curve segments can be used to represent the linear entities. The curve segments, as one-dimensional spatial objects, we generated by spline interpolation technique such as Bezier technique. In an effort to improve its accuracy in resembling the linear entities, the Bezier technique was modified generating a new technique (called New technique) (Kiyun, 1998). In this paper, validity of the New technique was tested. Test focused on answering two questions: (1) whether or not the curve segments from the New technique replace line segments so as to enhance the accuracy of representations of linear entities, and (2) whether or not the curve segments from the New technique represent the linear entities more accurately than curve segments from the Bezier technique. Answering these two questions entailed two hypothesis tests. For test data, a series of hydrologic lines on 7.5-minute USGS map series were selected. Test were done using t-test method and statistical inferences were made from the results. Test results indicated that curve segments from both the Bezier and New techniques represent the linear entities more accurately than the line segments do. In addition, curve segments from the New technique represent the linear entities more accurately than the line segments from the Bezier technique do at probability level 69% or higher.

  • PDF

A STUDY ON ACCURACY AND DIMENSIONAL STABILITY ACCORDING TO IMPRESS10N METHODS (인상채득방법과 방향에 따른 인상체의 정밀성과 체적 안정성에 관한 연구)

  • Lee, Jae-Young;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.567-580
    • /
    • 1999
  • Accurate reproduction of intraoral tissue is essential in the fabrication of fixed prosthesis. This selection of impression material and method is very important. In this study, vinyl polysiloxane type impression material $Panasil^{(R)}$ was used. Three impression methods ; one-step technique, individual tray technique, and individual tooth tray technique using the vinyl polysiloxane type bite registration material $Futar^{(R)}$ Occlusion, were used to take horizontal and vertical impression. Improved stone models were fabricated. The amount of occlusal surface discrepaneies, interabutment distance discrepancies, amount of marginal defect were evaluated with the $X-PLAN360d^{(R)}$ and photoscanning. The results were as follows. 1. There was no significant difference in occlusal surface according to the directions and techniques of impression taking. 2. There was no significant difference in interabutment distance discrepancies according to the directions and techniques of impression taking 3. There was no significant difference in marginal discrepancies according to the direction of impression taking but there was significant difference between one-step technique and individual tray technique, individual tooth tray technique (P<0.05). Taken together, these results suggest that individual tray technique and individual tooth tray technique are more accurate for impression taking than one-step technique.

  • PDF

Effects of Modified Mulligan Technique accompanied by Taping on the Scapular Posture and Shoulder Range of Motion of Stroke Patients (테이핑을 동반한 수정된 멀리건 기법 적용이 뇌졸중 환자의 견갑골 자세와 견관절 가동범위에 미치는 영향)

  • Kim, Tae-keun;Shin, Seung-je;Jeon, Young-gil
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.22 no.2
    • /
    • pp.1-7
    • /
    • 2016
  • Background: The purpose of this study was to investigate the effects of between modified mulligan technique and modified mulligan technique with taping on the active range of motion & passive range of motion, scapula index into the stroke patients. Methods: The subjects with stroke were randomly divided into two groups. Group 1 (n=9) was conducted modified mulligan technique and Group 2 (n=9) was conducted modified mulligan technique with taping week three times for 4weeks. Active range of motion (AROM), passive range of motion (PROM) and scapula index (SI) were measured by goniometer and tape measure. Wilcoxon signed-rank tests were used to compare differences before and after intervention. Mann-Whitney U-test were conducted to compare before to after intervention in the two groups. Results: AROM was significantly different both groups (p<.05) and between groups were not significantly different into pre and post intervention (p>.05). PROM was significantly different both groups (p<.05) however, between groups were not significantly different into pre and post intervention (p>.05). SI was significantly different only group 2 and between groups were not significantly different (p>.05). Conclusions: This study demonstrated effective bo-th modified mulligan technique and modified mulligan technique with taping on the active range of motion and passive range of motion. Because only modified mulligan technique with taping are effective on the scapula index we recommend modified mulligan technique with taping than modified mulligan technique.

  • PDF

Reduction of Scattered Radiation by Air Gap Technique for High Kilovoltage Chest Roentgenography (흉부(胸部) 고관전압(高管電壓) 촬영(撮影)에 있어 Air Gap Technique를 이용한 산란선(散亂線) 경감(輕減)에 관(關)한 연구(硏究))

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok;Youn, Chul-Ho;Lee, Sang-Suk;Lim, Han-Young;Song, Jae-Kwan
    • Journal of radiological science and technology
    • /
    • v.3 no.1
    • /
    • pp.57-66
    • /
    • 1980
  • X-ray grid is the most important means to reduce the scattered ray from patients, but alternative way is air gap technique that is another name of Groedel technique. This technique is mainly used in chest radiography. Authors performed an experimental study on the air gap technique for chest radiography and obtained the results as follows; 1. In using the high voltage air technique, scattered ray could be reduced effectively, while the percentage of scattered ray was slightly increased than conventional grid technique. 2. In film contrast, 30cm air gap technique was inferior to 12:1 grid technique and contrast improvement was increased when the object was thicker and higher voltage was used. 3. The patient exposure dose was reduced about $25{\sim}45%$ compared with conventional grid technique by air gap technique used.

  • PDF

Comparing the efficiency and convenience of one-rescuer cardiopulmonary resuscitation chest compression techniques for infants (1인 구조자 영아 심폐소생술 가슴압박 방법에 따른 효율성 및 편리성 비교)

  • Kim, Yong-Joon;Lee, Kyoung-Youl
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.2
    • /
    • pp.109-123
    • /
    • 2019
  • Purpose: This study aimed to propose an effective one-rescuer infant cardiopulmonary resuscitation (CPR) chest compression technique by comparing the differences in efficacy, convenience, and pain levels between the two thumb-encircling and two finger techniques. Methods: Subjects were randomized to perform either two-thumb-encircling or two-finger technique for 8 minutes each on infant CPR manikins. After the chest compression, a survey was administered to the subjects to measure convenience and pain levels according to compression method. Results: Total compression depth over 8 minutes was significantly deeper for the two-thum-encircling technique ($43.5{\pm}4.8mm$) compared with the two-finger technique ($32.6{\pm}5.4mm$) (p<0.001). In terms of compression depth measured at 1-minute intervals, compression depth with the two-finger technique decreased from $38.3{\pm}4.23mm$ to $29.0{\pm}6.79mm$, whereas compression depth with the two-thumb-encircling technique did not show a significant change (from $43.7{\pm}4.12mm$ to $43.4{\pm}5mm$). The results of the survey indicated that, the majority of subjects found the two-thumb-encircling technique to be the most comfortable technique for compression depth (n=29, 64.4%). The majority of subjects (n=31, 68.9%) answered that the two-finger technique resulted in the most pain. Conclusion: Comparison of efficacy of the two-thumb-encircling and two-finger-techniques in the performance of one-rescuer infant CPR revealed that the two-thumb-encircling technique was more effective in maintaining chest compression depth.

Horizontal instability after acromioclavicular joint reduction using the two-hole technique is preferred over the loop technique: a single-blind randomized clinical trial

  • Mardani-Kivi, Mohsen;Asadi, Kamran;Leili, Ehsan Kazemnejad;Hashemi-Motlagh, Keyvan;Izadi, Amin;Pishgahpour, Mona;Darabipour, Zohre
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.3
    • /
    • pp.224-229
    • /
    • 2022
  • Background: Most acromioclavicular joint (ACJ) injuries are caused by direct trauma to the shoulders, and various methods and techniques are used to treat them; however, none of the options can be considered the gold standard. This study examines the horizontal stability of the ACJ after a complete dislocation was repaired using one of two Ethibond suture techniques, the loop technique and the two holes in the clavicle technique. Methods: In this single-blind, randomized clinical trial, 104 patients diagnosed with complete ACJ dislocation type V were treated using Ethibond sutures with either the loop technique or the two holes in the clavicle technique. Horizontal changes in the ACJ were radiographically assessed in the lateral axial view, and shoulder function was evaluated by the Constant (CS) and Taft (TS) scores at intervals of 3, 6, and 12 months after surgery. Results: The horizontal stability of the ACJ was better with the two-hole technique than the loop technique at all measurement times. CS and TS changes showed a significant upward trend over time with both techniques. The mean CS and TS at the final visit were 95.2 and 11.6 with the loop technique and 94.0 and 11.9 with the two-hole technique, respectively. The incidence of superficial infections caused by the subcutaneous pins was the same in the two groups. Conclusions: Due to the improved ACJ stability with the two-hole technique, it appears to be a more suitable option than the loop technique for AC joint reduction.

MECHANICAL PROPERTIES AND MICROLEAKAGE OF COMPOSITE RESIN MATERIALS CURED BY VARIABLE LIGHT INTENSITIES (가변 광도에 따른 복합레진의 기계적 물성 및 변연누출도 변화)

  • Han, Seung-Ryul;Min, Kyung-San;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.2
    • /
    • pp.134-145
    • /
    • 2003
  • Mechanical properties and microleakage of two composites [conventional hybrid type DenFil (VERICOM Co., Anyang, Korea) / micro matrix hybrid type Esthet X (Dentsply Caulk, Milford, DE, U.S.A.)] were evaluated to assess whether variable light intensity curing is better than conventional curing technique. Curing was done for 40 seconds in two ways of 2 step soft-start technique and 5 step ramping technique. Three kinds of light intensities of 50, 100, $200{\;}mW/\textrm{cm}^2$ were initially used for 10, 20, 30 seconds each and the maximum intensity of $600 {\;}mW/\textrm{cm}^2$ was used for the rest of curing time in a soft-start curing tech nique. In a ramping technique, curing was done with the same initial intensities and the light intensity was increased 5 times with the same rate to the maximum intensity of $600{\;}mW/\textrm{cm}^2$. After determining conditions that showed no different mechanical properties with conventional technique, Esthet X composite was filled in a class V cavity, which dimension was $4{\times}3{\times}1.5{\;}mm$ and cured under those conditions. Microleakage was evaluated in two ways of dye penetration and maximum gap estimation through SEM observation. ANOVA and Spearman's rho test were used to confirm any statistical significance among groups. The results were as follows : 1 Several curing conditions of variable light intensities resulted in the similar mechanical properties with a conventional continuous curing technique, except conditions that start curing with an initial light intensity of $50{\;}mW/\textrm{cm}^2$. 2. Conventional and ramping techniques were better than soft-start technique in mechanical properties of microhardness and compressive strength. 3. Soft-start group that started curing with an initial light intensity of $100{\;}mW/\textrm{cm}^2$ for 10 seconds showed the least dye penetration. Soft-start group that started curing with an initial light intensity of $200{\;}mW/\textrm{cm}^2$ for 10 seconds showed the smallest marginal gap, if there was no difference among groups. 4. Soft-start technique resulted in better dye-proof margin than conventional technique(p=0.014) and ramping technique(p = 0.002). 5. There was a very low relationship(p=0.157) between the methods of dye penetration and marginal gap determination through SEM evaluation. From the results of this study, it was revealed that ramping technique would be better than conventional technique in mechanical properties, however, soft-start technique might be better than conventional one in microleakage. It was concluded that much endeavor should be made to find out the curing conditions, which have advantages of both aspects or to solve these kinds of problems through a novel idea of polymerization.

A Study on Multi-Block Technique by Bi-CGSTAB Solver (Bi-CGSTAB 해법에 의한 복합격자망 해석방법에 관한 연구)

  • Bae, Jin-Hyo;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.8
    • /
    • pp.2611-2625
    • /
    • 1996
  • A numerical method on multi-block technique by Bi-CGSTAB(Bi-Conjugate Gradient STABilized) solver has been proposed. The present multi-block technique can reduce the numerical manipulation greatly because the common regions at the interface of each block are not necessary. In order to test the computational performance of present multi-block technique, the flow characteristics in a T type duct system and a N type duct system have been investigated by three kinds of methods such as the single-block method, the previous multi-block technique and the multi-block technique with Bi-CGSTAB solver. The results indicated that the required CPU time by present multi block technique was shorter than that of other two numerical methods and the convergency history was shown very stable at the present multi-block technique.

Three-dimensional Decorative Techniques of Flower Image Represented on Valentino Dress (발렌티노 드레스에 표현된 꽃이미지의 입체적 장식기법)

  • Rha, Soo-Im
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.14 no.3
    • /
    • pp.37-49
    • /
    • 2012
  • The purpose of this study is to provide basic data of dress design by researching three-dimensional decorative techniques representing flowers, a popular motif in dress design. This study analyzed 44 dresses that were presented in Valentino collection. The result of this study is as follows: First, the detailing expression method can show various patterns and colors through embroidery technique, sub-materials, and bonding techniques in embroidery, beads flower, and ribbon flowers. Second, the fabric flower technique expressed flower image in three-dimension in more various images than do either the ribbon or beads flower technique. Fabric flowers are mostly made from the same material as dresses. The expression technique of fabric flower is classified into the following three classifications: 1) A technique underlying a flower image with one, two and three large flowers, 2) a technique decorating a large area with a number of an identical motif, and 3) a technique highlighting a part of the body or design line by attracting eyes to one point, creating a corsage decorated where a designer wants to emphasize. Third, a silhouette technique realizes a flower image with a silhouette of a dress like sculpted structure and it is thus used less than a detailing expression technique. A flower image is expressed by making use of body lines or emphasizing the face. Finally, flower images on a dress were realized as a full blossomed flower, through visually streamlined shapes and curved lines.

  • PDF