• Title/Summary/Keyword: TE 5

Search Result 1,254, Processing Time 0.035 seconds

An Experimental Study on the Antioxidant Effect of Electroacupuncture at the Waiguan($TE_5$) (외관전침의 항산화 효과에 대한 실험적 연구)

  • Lee, Jae-Min;Lee, Hyun;Hong, Kwon-Eui
    • Journal of Acupuncture Research
    • /
    • v.24 no.5
    • /
    • pp.53-66
    • /
    • 2007
  • Objectives : The purpose of this study is to observe the antioxidant effect of electroaupuncture at TE5 on the rats that were given AAPH(50mg/kg) everyday. Methodes : The Rats were given AAPH(50mg/kg) in abdominal cavity everyday for one week. $TE_5-NR$ group were treated by acupucture on left $TE_5$ for 15min. $TE_5-EA$ group were treated by electroacupucture on left $TE_5$ for 15min. The author observe several changes of rats. First, it is change of rat weight. Second, it is change of Liver index. Third, it is changes of albumin, total bilirubin, LDL-cholesterol, LDH, Glucose, GOT, GPT. Fourth, it is changes of SOD & Catalase activity, Glutathione & NO & MDA concentration. Fifth, it is change of tissue. Results: 1. In the $TE_5-EA$ group, the live index was decreased significant compared with control & holder group. 2. In the $TE_5-EA$ group, the albumin level were increased significant compared with control & holder group, LDL-cholesterol, GOT level were decreased significant compared with control & holder group. 3. In the $TE_5-EA$ group, the SOD activity, Catalase activity were increased significant compared with control group, Glutathione level was increased significant compared with control & holder, sham-EA, $TE_5-NR$ group, NO and MDA concentration were decreased significant compared with control group.

  • PDF

Neutron-irradiated effect on the thermoelectric properties of Bi2Te3-based thermoelectric leg

  • Huanyu Zhao;Kai Liu;Zhiheng Xu;Yunpeng Liu;Xiaobin Tang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.3080-3087
    • /
    • 2023
  • Thermoelectric (TE) materials working in radioisotope thermoelectric generators are irradiated by neutrons throughout its service; thus, investigating the neutron irradiation stability of TE devices is necessary. Herein, the influence of neutron irradiation with fluences of 4.56 × 1010 and 1 × 1013 n/cm2 by pulsed neutron reactor on the electrical and thermal transport properties of n-type Bi2Te2.7Se0.3 and p-type Bi0.5Sb1.5Te3 thermoelectric alloys prepared by cold-pressing and molding is investigated. After neutron irradiation, the properties of thermoelectric materials fluctuate, which is related to the material type and irradiation fluence. Different from p-type thermoelectric materials, neutron irradiation has a positive effect on n-type Bi2Te2.7Se0.3 materials. This result might be due to the increase of carrier mobility and the optimization of electrical conductivity. Afterward, the effects of p-type and n-type TE devices with different treatments on the output performance of TE devices are further discussed. The positive and negative effects caused by irradiation can cancel each other to a certain extent. For TE devices paired with p-type Bi0.5Sb1.5Te3 and n-type Bi2Te2.7Se0.3 thermoelectric legs, the generated power and conversion efficiency are stable after neutron irradiation.

Effect of CdTe Deposition Conditions by Close spaced Sublimation on Photovoltaic Properties of CdS/CdTe Solar Cells (CdTe박막의 근접승화 제조조건에 따른 CdS/CdTe 태양전지의 광전압 특성)

  • Han, Byung-Wook;Ahn, Jin-Hyung;Ahn, Byung-Tae
    • Korean Journal of Materials Research
    • /
    • v.8 no.6
    • /
    • pp.493-498
    • /
    • 1998
  • CdTe films were deposited by close spaced sublimation with various substrate temperatures, cell areas, and thicknesses of CdTe and ITO layers and their effects on the CdS/CdTe solar cells were investigated. The resistivity of CdTe layers employed in this study was 3$\times$ $10^{4}$$\Omega$cm For constant substrate temperature the optimum substrate ternperature for CdTe deposition was $600^{\circ}C$. To obtain larger grain size and more compact microstructure, CdTe film was initially deposited at 62$0^{\circ}C$, and then deposited at 54$0^{\circ}C$. The CdTe film was annealed at 62$0^{\circ}C$ and $600^{\circ}C$ sequentially to maintain the CdTe film quality. The photovoitaic cell efficiency improved by the "two-wave" process. For constant substrate temperature, the optimum thickness for CdTe was 5-6$\mu m$. Above 6$\mu m$ CdTe thickness, the bulk resistance of CdTe film degraded the cell performance. As the cell area increased the $V_{oc}$ remained almost constant, while $J_{sc}$ and FF strongly decreased because of the increase of lateral resistance of the ITO layer. The optimum thickness of the ITa layer in this study was 300~450nm. In this experiment we obtained the efficiency of 9.4% in the O.5cm' cells. The series resistance of the cell should be further reduced to increase the fill factor and improve the efficiency.

  • PDF

Characteristics of Ag-added Ge2Sb2Te5 Thin Films and the Rapid Crystallization (Ag-첨가 Ge2Sb2Te5 박막의 물성 및 고속 결정화)

  • Kim, Sung-Won;Song, Ki-Ho;Lee, Hyun-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.7
    • /
    • pp.629-637
    • /
    • 2008
  • We report several experimental data capable of evaluating the amorphous-to-crystalline (a-c) phase transformation in $(Ag)_x(Ge_2Sb_2Te_5)_{1-x}$ (x = 0, 0.05, 0.1) thin films prepared by a thermal evaporation. The isothermal a-c structural phase changes were evaluated by XRD, and the optical transmittance was measured in the wavelength range of $800{\sim}3000$ nm using a UV-vis-IR spectrophotometer. A speed of the a-c transition was evaluated by detecting the reflection response signals using a nano-pulse scanner with 658 nm laser diode (power P = $1{\sim}17$ mW, pulse duration t = $10{\sim}460$ ns). The surface morphology and roughness of the films were imaged by AFM. It was found that the crystallization speed was so enhanced with an increase of Ag content. While the sheet resistance of c-phase $(Ag)_x(Ge_2Sb_2Te_5)_{1-x}$ was similar to that of c-phase $Ge_2Sb_2Te_5$ (i.e., $R_c{\sim}10{\Omega}/{\square}$), the sheet resistance of a-phase $(Ag)_x(Ge_2Sb_2Te_5)_{1-x}$ was found to be lager than that of a-phase $Ge_2Sb_2Te_5$, $R_a{\sim}5{\times}10^6{\Omega}{/\square}$. For example, the ratios of $R_a/R_c$ for $Ge_2Sb_2Te_5$ and $(Ag)_{0.1}(Ge_2Sb_2Te_5)_{0.9}$ were approximately $5{\times}10^5$ and $5{\times}10^6$, respectively.

Phase Change Properties of Amorphous Ge1Se1Te2 and Ge2Sb2Te5 Chalcogenide Thin Films (비정질 Ge1Se1Te2 과 Ge2Sb2Te5 칼코게나이드 박막의 상변화특성)

  • Chung Hong-Bay;Cho Won-Ju;Ku Sang-Mo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.10
    • /
    • pp.918-922
    • /
    • 2006
  • Chalcogenide Phase change memory has the high performance necessary for next-generation memory, because it is a nonvolatile memory with high programming speed, low programming voltage, high sensing margin, low power consumption and long cycle duration. To minimize the power consumption and the program voltage, the new composition material which shows the better phase-change properties than conventional $Ge_2Sb_2Te_5$ device has to be needed by accurate material engineering. In the present work, we investigate the basic thermal and the electrical properties due to phase-change compared with chalcogenide-based new composition $Ge_1Se_1Te_2$ material thin film and convetional $Ge_2Sb_2Te_5$ PRAM thin film. The fabricated new composition $Ge_1Se_1Te_2$ thin film exhibited a successful switching between an amorphous and a crystalline phase by applying a 950 ns -6.2 V set pulse and a 90 ns -8.2 V reset pulse. It is expected that the new composition $Ge_1Se_1Te_2$ material thin film device will be possible to applicable to overcome the Set/Reset problem for the nonvolatile memory device element of PRAM instead of conventional $Ge_2Sb_2Te_5$ device.

A Study on the Electrical Properties of MIM Structures Based on Ge2Sb2Te5 and Ge8Sb2Te11 Thin Films for ReRAM (ReRAM응용을 위한 Ge2Sb2Te5와 Ge8Sb2Te11 기반 MIM구조 박막의 전기적 특성 연구)

  • Jang, Hwi-Jong;Kong, Heon;Yeo, Jong-Bin;Lee, Hyun-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.3
    • /
    • pp.144-147
    • /
    • 2017
  • In this study, $Ge_2Sb_2Te_5$ and $Ge_8Sb_2Te_{11}$ were used as an insulator layer to fabricate ReRAM devices. The resistance change is correlated to the appearance or disappearance of a conductivity filament at the surface of the GeSbTe layer. Changes in the electrical properties of ITO/GeSbTe/Ag devices were measured using a I-V-L measurement system. As a result, compared to the $ITO/Ge_8Sb_2Te_{11}/Ag$ device, this $ITO/Ge_2Sb_2Te_5/Ag$ ReRAM device exhibits highly uniform bipolar resistive switching characteristics, such as the operating voltages, and the resistance values.

Thermoelectric Characteristics of the Electroplated Bi-Te Films and Photoresist Process for Fabrication of Micro Thermoelectric Devices (전기도금 공정으로 제조한 Bi-Te 박막의 열전특성 및 미세열전소자 형성용 포토레지스트 공정)

  • Lee, Kwang-Yong;Oh, Tae-Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.2 s.43
    • /
    • pp.9-15
    • /
    • 2007
  • Thermoelectric properties of the electrodeposited Bi-Te films and photoresist process have been investigated to apply for thermoelectric thin film devices. After plating in Bi-Te solutions of 20 mM concentration, which were prepared by dissolving $Bi_2O_3$ and $TeO_2$ into 1M $HNO_3$, thermoelectric properties of the films were characterized with variation of the Te/(Bi+Te) ratio in a plating solution. With increasing the Te/(Bi+Te) ratio in the plating solution from 0.5 to 0.65, Seebeck coefficient of Bi-Te films changed from $-59{\mu}V/K$ to $-48{\mu}V/K$ and electrical resistivity was lowered from $1m{\Omega}-cm$ to $0.8m{\Omega}-cm$ due to the increase in the electron concentration. Maximum power factor of $3.5{\times}10^{-4}W/K^2-m$ was obtained for the Bi-Te film with the $Bi_2Te_3$ stoichiometric composition. Using multilayer overhang process, the photoresist pattern to form thermoelectric legs of 30 m depth and 100m diameter was successfully fabricated fur micro thermoelectric device applications.

  • PDF