• Title/Summary/Keyword: TCD

Search Result 174, Processing Time 0.028 seconds

Development of a Sensor System to Measure Real Time Vibro Displacement of Civil Structure (레이저 센서를 이용한 구조물의 변위 측정 장비 개발)

  • O, Heung-Il;Kim, Hui-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.823-825
    • /
    • 2003
  • A sensor system was designed to measure real time vibro displacement of civil structure. The He-Ne laser is used for the displacement measuring method, because it guarantees short time stabilization, long time output power stability. Also, it guarantees simple maintenances and repairs under actual using condition. The line CCD image sensor(Tcd-142d) is used to detect the displacement of Ne-Ne laser responding to the vibro of civil structure. For accurate measurement and comparison, CDP-50 is used. Usually CDF-50 (Strain type displacement device) is used for the standard correction device of optical measurement equipments. The data processing part is consists of Optical sensor part, Wireless data transmission device, DAQp-1200, and LapView program. The displacement data of vibro from optical sensor part inputted to wireless data transmission device and then transmitted to DAQp-1200 in main control room. DAQp-1200 performs A/D conversion for the receiving data. After that the converted data inputted to computer system using LapView program for user display. The significance of this paper is to develope a convenient, accurate and lost saving real time displacement measurement system for the civil structure.

  • PDF

The Effects of Regular Resistive Exercise on Cardiopulmonary Ability and Cerebral Blood Flow Velocity (규칙적인 저항 운동이 심폐 능력과 뇌혈류 속도에 미치는 영향)

  • Yu, Jae-Ho;Lee, Suk-Min
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.2
    • /
    • pp.255-264
    • /
    • 2010
  • Purpose : The purpose of this study is to analysis effects of resistive exercise on cardiopulmonary fitness and cerebral artery blood flow velocity. Methods : Ten healthy university students had done resistive exercise without aerobic exercise over one year participated resistive exercise group and ten general university students, then were calculated oxygen consumption ($VO_2$) and respiratory exchange rate($VO_2/VCO_2$). After a week, they were measured Transcranial Doppler Ultrasonography(TCD) at moderate exercise(HRmax 50%), maximal exercise (HRmax 100%) for taking cerebral blood flow velocity. Results : In the comparison between groups, resistive exercise group showed significant higher oxygen consumption and lower respiratory exchange than controls(p<0.05). In resistive exercise group, oxygen consumption was significant negative correlation with cerebral artery pulsatory index(p<0.05). but, oxygen consumption was significant positive correlation with systolic blood flow velocity in controls(p<0.05). Conclusions : After considering all the factors, important value in resistive exercise is regular participation and help us increasing contingency response ability.

Preparation of Affinity Membrane by Electrospinning Method (전기방사법에 의한 친화막 제조)

  • Byun, Hong-Sik;Hong, Byung-Pyo
    • Membrane Journal
    • /
    • v.17 no.1
    • /
    • pp.23-30
    • /
    • 2007
  • Protein affinity membranes based on polyethersulfone (PES) and bovine serum albumin (BSA) were prepared by using an electrospinning method. The changes in the size of nanofiber according to the various conditions of electrospinning (concentration of spinning solution, voltage, flow rate, tip to collector distance) were investigated, and the preparation conditions of the affinity membrane were optimized. XPS and FT-IR results showed the firm incorporation of BSA with PES. It was found PES-BSA nanofibers could be prepared at the temp. of $20{\sim}22^{\circ}C$ and humidity of $45{\sim}55%$. The size of nanofibers increased with increase of the content of PES in the spinning solution while BSA did not affect much to the size of nanofiber. It was also revealed that the narrow size distribution of nanofiber could be obtained with PES 7 wt%, BSA 0.7 wt%, HFP 92.3 wt% at the electrospinning conditions of 1 mL/hr, 10 cm TCD, and 10 kV.

A case of the patient treated with Chunmagudung-um who was diagnosed with Vertebrobasilar insufficiency (척추기저동맥부전환자를 천마구등음(天麻鉤藤飮)으로 치료한 치험 1례)

  • Song, Cheol-Min;Chang, Tong-Young;Rhim, Eun-Kyung;Lee, Yun-Jae;Lee, Jung-Sub;Shin, Sun-Ho;Lee, In;Moon, Byung-Soon;Jeong, Hyun-Ae
    • The Journal of Internal Korean Medicine
    • /
    • v.26 no.3
    • /
    • pp.699-707
    • /
    • 2005
  • Vertebrobasilar insuffciency(VBI) is also refered to as vertebrobasilar transient ischemic attack(V-B TIA). Vertebrobasilar insufficiency is often undiagnosed or misdiagnosed due to complexity of the symptoms. Transcranial doppler(TCD) can be used to possible to record the blood flow velocities in the cerebral arteries through the intact cranium. Transcranial doppler and magnetic resonance angiography(MRA) are both noninvasive techniques that can be used in vertebrobasilar insufficiency, but transcranial doppler is more sensitive with respect to evaluating stenotic lesion of the arteries than magnetic resonance angiographv. Diagnostic values of transcranial doppler were assessed in patients with vertebrobasilar insufficiency. A case of vertebrobasilar insufficiency is here reported. A 62-year-old man with dizzness, nausea and tremor because of vertebrobasilar insufficiency was admitted at Wonkwang Oriental Medicine Hospital. He was treated with the herbal medicine Chunmagudung-um and with acupunture. Results showed improvement of symptoms and favorable transcranial doppler readings. The process used in this successful treatment is here described.

  • PDF

Installation and Test Run of Comprehensive Analysis System for SF6 in Power Equipment

  • Lee, Jeong Eun;Kim, Kwang Sin;Kim, Ah Reum;Park, Seoksoon;Kim, Kyeongsook
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.1
    • /
    • pp.41-47
    • /
    • 2017
  • After $SF_6$, which is being used in power equipment as an insulating material, is classified as one of the 6 major greenhouse gases, the maintenance and the refinement of used $SF_6$ started to get attention. In regard to this, KEPCO Research Institute (KEPRI) is developing $SF_6$ recovery and refinement technology starting with establishing a comprehensive $SF_6$ analysis system. With the analysis system, qualitative and quantitative analyses of the purity and the impurities of $SF_6$ before and after recovery, and before and after refinement have been carried out. The analysis system is comprised of GC-DID (Gas Chromatograph -Discharge Ionization Detector) for trace impurities analysis, GC-TCD (Thermal Conductivity Detector) for analyses of $SF_6$ purity and major impurities concentration from several hundred ppm up to percent range, GC-MSD (Mass Selective Detector) for analyses of impurities not included in standard gas, FT-IR (Fourier Transform-Infrared) Spectrometer for analysis of HF and $SO_2$, and moisture analyzer for analysis of moisture below 100 ppm. With this analysis system, complete analysis method of $SF_6$ has been established. This analysis system is being used in the maintenance of power equipment and the development of $SF_6$ recovery and refinement technologies. In this paper, the analysis results of four samples - gas and liquid phase $SF_6$ samples from a $SF_6$ refinement system before and after refinement are presented.

Influence of Reaction Temperature on Bio-oil Production from Rice Straw by the Pyrolysis (볏짚으로부터 바이오오일 생산에 대한 열분해 반응온도의 영향)

  • Kang Bo-Sung;Park Young-Kwon;Kim Joo-Sik
    • Resources Recycling
    • /
    • v.15 no.1 s.69
    • /
    • pp.12-19
    • /
    • 2006
  • Rice straw is one or the main renewable energy sources in Korea. Bio-oil is produced from rice straw with a lab-scale equipment mainly with a fluidized bed and a char removal system. It was investigated how the reaction temperature affected the production of bio-oil and the efficiency of a char removal system. To elucidate how the temperature depended on the production of bio-oil, experiments were conducted at $466^{\circ}C,\;504^{\circ}C\;and\;579^{\circ}C$, respectively. The mass balance was established in each experiment, and the produced gas and oil were analyzed with the aid of GCs and a GC-MS system. The char removal system is composed of a cyclone and a hot filter. Tn the experiments, we observed that the production of bio-oil was decreased with temperature, and the bio-oil contained very useful chemicals.

Counting Method and Application of Pulse-taking on both Carotid and Wrist Pulses in Suwen·LiuJieCangXiangLun (『소문(素問)·육절장상론(六節藏象論)』의 인영(人迎)·촌구(寸口) 맥진(脈診)의 셈법과 활용에 대한 연구)

  • Jo, Hak-jun
    • Journal of Korean Medical classics
    • /
    • v.30 no.3
    • /
    • pp.77-93
    • /
    • 2017
  • Objectives : Clear and detailed analysis on Pulse-taking on both Carotid and Wrist Pulses is an absolute prerequisite if it is to be applied in real practice or its practical value proven. Methods : The original notes found in Suwen and Lingshu, their translations, and conventional studies regarding Suwen LiuJieCangXiangLun's Pulse-taking are compared and analyzed to find cases within medical texts where this method was used and to get an idea of the direction taken by the conventional study. Results : The ilsung, esung, samsung, and sasung of Carotid (or wrist pulses) refers that the pulse is one-, two-, three-, four-fold in differences. Refrainment should be practiced while comparing carotid and wrist pulses. Rather, they need to be compared with their normal states. Used by Luo Tianyi in Ming Dunasty, this method of pulse-taking was used for (radial artery) when diagnosing and treating the degree of seriousness of food injury. The measurement of maximum blood flow velocity using TCD done recently proved the validity of this pulse-taking, and it's been used for alleviating hypertension or tinnitus through acupuncture, or abating intractable diseases (around carotid). Conclusions : The obscurity of the measuring method of this pulse-taking can be resolved, and the problem which occurs while comparing carotid and wrist pulses can be solved. Even though there are differences in opinion regarding the positions when comparing the two pulses, their practical values are acknowledged since their usages in diagnosis, treatments, experiments, and researches have yielded positive results to a degree. They may not be used that often, but they are nonetheless under utilization.

Drainage Alone or Combined with Anti-tumor Therapy for Treatment of Obstructive Jaundice Caused by Recurrence and Metastasis after Primary Tumor Resection

  • Xu, Chuan;Huang, Xin-En;Wang, Shu-Xiang;Lv, Peng-Hua;Sun, Ling;Wang, Fu-An;Wang, Li-Fu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.6
    • /
    • pp.2681-2684
    • /
    • 2014
  • Aim: To compare drainage alone or combined with anti-tumor therapy for treatment of obstructive jaundice caused by recurrence and metastasis after primary tumor resection. Materials and Methods: We collect 42 patients with obstructive jaundice caused by recurrence and metastasis after tumor resection from January 2008 - August 2012, for which percutaneous transhepatic catheter drainage (pTCD)/percutaneous transhepatic biliary stenting (pTBS) were performed. In 25 patients drainage was combined with anti-tumor treatment, antineoplastic therapy including intra/postprodure local treatment and postoperative systemic chemotherapy, the other 17 undergoing drainage only. We assessed the two kinds of treatment with regard to patient prognosis. Results: Both treatments demonstrated good effects in reducing bilirubin levels in the short term and promoting liver function. The time to reobstruction was 125 days in the combined group and 89 days in the drainage only group; the mean survival times were 185 and 128 days, the differences being significant. Conclusions: Interventional drainage in the treatment of the obstructive jaundice caused by recurrence and metastasis after tumor resection can decrease bilirubin level quickly in a short term and promote the liver function recovery. Combined treatment prolongs the survival time and period before reobstruction as compared to drainage only.

Proposed Schemes for Image Sensors Compatibility in IEEE TG7r1 Image Sensor Communications

  • Nguyen, Trang;Hong, Chang Hyun;Jang, Yeong Min
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.7
    • /
    • pp.799-808
    • /
    • 2016
  • The IEEE 802.15.7r1 Task Group (TG7r1), known as the revision of the IEEE 802.15.7 Visible Light Communication standard targeting the commercial usage of visible light communication systems which mainly use either image sensors or cameras, is of interest in this paper. The vast challenge in Image Sensor Communications (ISC), as it has been addressed in the Technical Consideration Document (TCD) of the TG7r1, is the Image Sensor Compatibility to support the variety of different commercial cameras available on the market. The on-going ISC standard must adhere to compatible image sensors regulations. This paper brings an inside review of the TG7r1 and an inside look of related works on Image Sensor Communications. The paper analyzes the compatibility features by introducing a revised model of receiver to explain how those features are necessary. One of the most challenging but interesting features is the capability in being compatible to camera frame rates. The variation of camera frame rate is modeled from verified experimental results. Noticeably, three singular approaches to support frame rates compatibility, including temporal approach, spatial approach, and frequency-domain approach, are proposed on the paper along with concise definitions. Those schemes have been presented as valuable proposals on the call-for-proposal meeting series of the TG7r1 recently.

Influence of Reaction Temperature on the Pyrolytic Product of Rice Straw by Fast Pyrolysis using a Fluidized Bed (볏짚의 급속 열분해 생성물에 대한 반응온도의 영향)

  • Kang, Bo-Sung;Park, Young-Kwon;Kim, Joo-Sik
    • Proceedings of the Korean Institute of Resources Recycling Conference
    • /
    • 2005.10a
    • /
    • pp.47-58
    • /
    • 2005
  • Rice straw is one of the main renewable energy sources in Korea, and bio-oil is produced from rice straw with a lab. scale plant equipped mainly with a fluidized bed and a char removal system. We investigated how the reaction temperature affected the production of bio-oil and the efficiency of a char removal system. To elucidate how the temperature depended on the production of bio-oil, experiment were conducted between $450^{\circ}C\;and\;600^{\circ}C$ with a feed rate of about 300g/h. The mass balance was established in each experiment, and the produced gas and oil were analyzed with the aid of GCs and a GC-MS system. The char removal system is composed of a cyclone and a hot filter. In the experiments, we observed that the optimum reaction temperature range for the production of bio-oil is between $450^{\circ}C\;and\;500^{\circ}C$.

  • PDF