• Title/Summary/Keyword: TAS method

Search Result 52, Processing Time 0.028 seconds

The Effect of TAS Method by an Auxiliary Method to Tunnel (터널보조공법으로서 TAS공법의 적용효과)

  • 천병식;여유현;백정식;최춘식;윤계한;황송연
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.213-220
    • /
    • 2002
  • Generally it is informed that urethane materials are superior to the others in physical characteristics, durability, ground improvement and the influence to environment . But, the existing urethane methods are too expensive to apply. So this study has analyzed the applicability of TAS method which has developed the existing urethane injection mechanism. From the results, Extending the max-infection distance over l0m from 6m which the existing methods could inject to, TAS method has proved to be economical. Also, the TAS method is obtained quickly to ground improvement effect in various tunnel constructions because rise-time was relatively shorter than that of cement-grouting. Therefore, it is expected that TAS method would be applied a lot for water proof and ground improvement etc. owing to its many advantages mentioned the above.

  • PDF

The Application and Geo-Enviromental Effect on TAS Method (TAS공법의 적용성과 지반환경 영향)

  • Chun, Byung Sik;Yeoh, Yoo Hyeon;Baik, Jung-Shik;Choi, Choon-Sik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.3
    • /
    • pp.27-36
    • /
    • 2002
  • Generally, it is known that urethane injection is excellent in long-term durability and environment friendly for ground improvement. However, urethane grouting has short rise time thus the penetration distance from the injection point is so short. Therefore, urethane injection cannot be used for the site where requires ground improvement in deep location from the injection point. Other injection materials such as cement cannot be alternatives when rapid hardening is required. From this study, we improve disadvantage urethane injection by developing TAS method. From the field tests, it is ascertained that TAS increases injection distance over 10m, which is further than that of original urethane grouting. In addition, TAS has relatively short Rise-time compared to cement grouting thus instantaneous improvement can be mobilized right after the injection. Short Rise-time and long penetration distance provide excellent applicability for tunnel construction.

  • PDF

Comparison of Reliability and Validity of Three Korean Versions of the 20-Item Toronto Alexithymia Scale (TAS-20의 한국판 3종간의 신뢰도 및 타당도 비교)

  • Chung, Un-Sun;Rim, Hyo-Deog;Lee, Yang-Hyun;Kim, Sang-Heon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.11 no.1
    • /
    • pp.77-88
    • /
    • 2003
  • Objectives: The purpose of this study was to compare reliability and validity of three Korean versions of the 20-item Toronto Alexithymia scale and to confirm the most reliable and validated Korean translation of the 20-item Toronto Alexithymia Scale for both clinical and research purpose in Korea. The first one was a Korean version of the 20-Item Toronto Alexithymia Scale developed by Lee YH et al in 1996 which was designated as TAS-20K(1996) in this study. This scale had a problem with one item due to the cultural difference regarding the word 'analyzing' between western culture and Korean culture. The second one was the revised version of TAS-20K(1996) on that point by Lee YH et al in 1996 without validation which was designated as TAS-20K(2003) in this study. The third one was a 23-item Korean version developed by Sin HG and Won HT in 1997, which was somewhat different from the 20-item Toronto Alexithymia Scale(TAS-20) in the number of total item, the content of some items and the scoring method. This scale was designated as S-TAS here. Methods: 408 medical students were tested with one scale composed of all the different items randomly arranged from the three versions. We evaluated goodness-of-fit and Cronbach $\alpha$ coefficients of three scales for reliability. We used confirmatory factor analysis to compare validity. Results: TAS-20K(2003) showed that it had better internal consistency than TAS-20K(1996), which implied that the cultural difference should be considered in the Korean translation. Both TAS-20K(2003) and S-TAS replicated three-factor structures and had adequacy of fit, good internal consistency and acceptable validity. However, S-TAS had one item with poor item-factor correlation and didn't show high correlation between item 2 and factor 1 as before in 1997. Conclusion: Although S-TAS had added 3 items and changed the content of two items, it didn't show better reliability and validity than TAS-20K(2003). Therefore it is proposed to use TAS-20K (2003) as the Korean version of the 20-item Toronto Alexithymia Scale(TAS-20K) for international communication of results of Alexithymia research. It has good internal consistency and validity and maintains original items, the same construct and scoring method as the 20-item Toronto Alexithymia Scale.

  • PDF

A Design for Evaluation of the Trauma Apportionment in Cerebral Infarction after Trauma

  • Kim, Tae-Hoon;Lee, Kyeong-Seok;Park, Hae-Ran;Shim, Jae-Joon;Yoon, Seok-Mann;Doh, Jae-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.1
    • /
    • pp.19-22
    • /
    • 2015
  • Objective : Posttraumatic cerebral infarction (CI) is a well-known complication of traumatic brain injury (TBI). However, the causation and apportionment of trauma in patients with CI after TBI is not easy. There is a scoring method, so-called trauma apportionment score (TAS) for CI, consisted with the age, the interval, and the severity of the TBI. We evaluated the reliability of this score. Methods : We selected two typical cases of traumatic CI. We also selected consecutive 50 patients due to spontaneous CI. We calculated TAS in both patients with traumatic and spontaneous CI. To enhance the reliability, we revised TAS (rTAS) adding three more items, such as systemic illness, bad health habits, and doctor's opinion. We also calculated rTAS in the same patients. Results : Even in 50 patients with spontaneous CI, the TAS was 4 in 44 patients, and 5 in 6 patients. TAS could not assess the apportionment of trauma efficiently. We recalculated the rTAS in the same patients. The rTAS was not more than 11 in more than 70% of the spontaneous CI. Compared to TAS, rTAS definitely enhanced the discriminating ability. However, there were still significant overlapping areas. Conclusion : TAS alone is insufficient to differentiate the cause or apportionment of trauma in some obscure cases of CI. Although the rTAS may enhance the reliability, it also should be used with cautions.

A study on the flatness of automotive torque-angle sensors (자동차 토크앵글센서(TAS)의 평면 정밀도에 관한 연구)

  • Yoon, Sean-Jhin;Cho, Yong-Moo
    • Design & Manufacturing
    • /
    • v.12 no.2
    • /
    • pp.11-15
    • /
    • 2018
  • In this study, we proposed three analysis methods to calculate the flatness of torque-angle sensors (TAS). We introduced two statistical and one geometrical methods in evaluating the precision of the flat plane in the axis direction for TAS. To verified the results, we fabricated TAS and a reference sample using a injection molding machine, mold, polyester as a raw material. We measured ($x_i$, $y_i$) position using 3D contact automated system and applied three analysis methods developed for TAS and a reference sample to see the feasibility. While each analysis method has its own pros and cons, the analysis using the shortest optimal distance was the most precise technique for the flatness evaluation of TAS components.

Temporary Access Selection Technology in WIFI Networks

  • Lu, Yang;Tan, Xuezhi;Mo, Yun;Ma, Lin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.12
    • /
    • pp.4269-4292
    • /
    • 2014
  • Currently, increasing numbers of access points (AP) are being deployed in enterprise offices, campuses and municipal downtowns for flexible Internet connectivity, but most of these access points are idle or redundant most of the time, which causes significant energy waste. Therefore, with respect to power conservation, applying energy efficient strategies in WIFI networks is strongly advocated. One feasible method is dynamically managing network resources, particularly APs, by powering devices on or off. However, when an AP is powered on, the device is initialized through a long boot time, during which period clients cannot be associated with it; therefore, the network performance would be greatly impacted. In this paper, based on a global view of an entire WLAN, we propose an AP selection technology, known as Temporary Access Selection (TAS). The criterion of TAS is a fusion metric consisting of two evaluation indexes which are based on throughput and battery life, respectively. TAS is both service and clients' preference specific through balancing the data rate, battery life and packet size. TAS also works well independently in traditional WLANs in which no energy efficient strategy is deployed. Moreover, this paper demonstrates the feasibility and performance of TAS through experiments and simulations with Network Simulator version 3 (NS3).

Dynamic Programming Approach for Determining Optimal Levels of Technical Attributes in QFD under Multi-Segment Market (다수의 개별시장 하에서 QFD의 기술속성의 최적 값을 결정하기 위한 동적 계획법)

  • Yoo, Jaewook
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.2
    • /
    • pp.120-128
    • /
    • 2015
  • Quality function deployment (QFD) is a useful method in product design and development to maximize customer satisfaction. In the QFD, the technical attributes (TAs) affecting the product performance are identified, and product performance is improved to optimize customer requirements (CRs). For product development, determining the optimal levels of TAs is crucial during QFD optimization. Many optimization methods have been proposed to obtain the optimal levels of TAs in QFD. In these studies, the levels of TAs are assumed to be continuous while they are often taken as discrete in real world application. Another assumption in QFD optimization is that the requirements of the heterogeneous customers can be generalized and hence only one house of quality (HoQ) is used to connect with CRs. However, customers often have various requirements and preferences on a product. Therefore, a product market can be partitioned into several market segments, each of which contains a number of customers with homogeneous preferences. To overcome these problems, this paper proposes an optimization approach to find the optimal set of TAs under multi-segment market. Dynamic Programming (DP) methodology is developed to maximize the overall customer satisfaction for the market considering the weights of importance of different segments. Finally, a case study is provided for illustrating the proposed optimization approach.

Comparison of Outcomes after Atlantoaxial Fusion with Transarticular Screws and Screw-Rod Constructs

  • Kim, Ji Yong;Oh, Chang Hyun;Yoon, Seung Hwan;Park, Hyeong-Chun;Seo, Hyun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.5
    • /
    • pp.255-260
    • /
    • 2014
  • Objective : The purpose of this study was to compare the radiological and neurological outcomes between two atlantoaxial fusion method for atlantoaxial stabilization; C1 lateral mass-C2 pedicle screws (screw-rod constructs, SRC) versus C1-2 transarticular screws (TAS). Methods : Forty-one patients in whom atlantoaxial instability was treated with atlantoaxial fixation by SRC group (27 patients, from March 2005 to May 2011) or TAS group (14 patients, from May 2000 to December 2005) were retrospectively reviewed. Numeric rating scale (NRS) for pain assessment, Oswestry disability index (ODI), and Frankel grade were also checked for neurological outcome. In radiologic outcome assessment, proper screw position and fusion rate were checked. Perioperative parameters such as blood loss during operation, operation time, and radiation exposure time were also reviewed. Results : The improvement of NRS and ODI were not different between both groups significantly. Good to excellent response in Frankel grade is shown similarly in both groups. Proper screw position and fusion rate were also observed similarly between two groups. Total bleeding amount during operation is lesser in SRC group than TAS group, but not significantly (p=0.06). Operation time and X-ray exposure time were shorter in SRC group than in TAS group (all p<0.001). Conclusion : Both TAS and SRC could be selected as safe and effective treatment options for C1-2 instability. But the perioperative result, which is technical demanding and X-ray exposure might be expected better in SRC group compared to TAS group.

Evaluation of Antioxidant Status and Correlation among Antioxidant Indices in Female College Students

  • Kim, Jung-Hee;Heajoon Ahn
    • Journal of Community Nutrition
    • /
    • v.5 no.1
    • /
    • pp.13-20
    • /
    • 2003
  • This study was done to evaluate the antioxidant status of female college students by determining their intakes and plasma levels of antioxidnt vitamins (vitamin C, A and E) and total antioxidant status (TAS). Subjects were 46 healthy female college students aged 20 - 29 years. Body composition was determined by a multifrequency bioelectrical impedance analysis. Dietary intakes were examined by 24hr record method and nutrients intakes were analyzed by the Computer Aided Nutritional analysis program for professional (CAN-pro). Plasma vitamin C level were measured by spectrophotometric method and retinol, ${\beta}$-carotene, ${\alpha}$-tocopherol were measured by HPLC. Plasma TAS was measured with a Randox kit using the trolox equivalent antioxidant capacity (TEAC) method. Daily energy and protein intakes of the female college students were 1670.5㎉ (83% of RDA) and 63.3g (115.1% of RDA), respectively. However their intakes of Ca and Fe were below 75% of RDA. Their intakes of vitamin A and C were 596.6 ${\mu}$ gRE (85.2% of RDA) and 71.0mg (101.4% of RDA), respectively. Plasma levels of vitamin C, retinol, ${\beta}$-carotene and ${\alpha}$-tocopherol were 14.7mg/L, 0.7mg/L, 0.2mg/L and 9.1mg/L, respectively which were within normal range. There was no subject with deficiency or marginal level in plasma vitamin A and C. However 1.6% of the subjects had below adequate level in vitamin E. Plasma TAS level was 1.2mmol/L. Correlation data showed that all plasma antioxidant vitamins were positively correlated with plasma TAS. Overall data indicate that the antioxidant status of female college students were pretty good. However it might be necessary to educate them to eat more fruits and vegetables for preventing many chronic diseases in a later life. (J Community Nutrition 5(1) : 13∼20, 2003)

Polymorphisms of TAS1R3 and GNAT3 Genes Are Associated with Patients with Taste Disorder (미각장애와 TAS1R3 및 GNAT3 유전자의 다형성과의 연관성)

  • Bae, Jae-Woong;Kim, Un-Kyung;Kwon, Tae-Jun;Choi, Su-Jin;Ye, Mi-Kyung
    • Journal of Life Science
    • /
    • v.21 no.3
    • /
    • pp.412-416
    • /
    • 2011
  • Taste sensation plays a crucial role in selecting and ingesting foods with different qualities which convey information about their nutrient content and/or safety. Sweetness is one of the five modalities in humans and serves as an energy resource for metabolism. There are reports on allelic polymorphisms which influence perception of sweetness in mice and humans. Since the influence of genetic factors on taste disorder has not been studied, we investigated the association of genetic polymorphisms in TAS1R3 and guanine nucleotide binding protein, alpha transducing 3 (GNAT3) genes and taste disorder. A total of 150 individuals composed of 50 patients with taste disorder and 100 healthy controls were recruited for the study and PCR-mediated directing sequencing method was used to genotype for two different single nucleotide polymorphisms (SNPs) - rs307355 (T>C) and rs35744813 (T>C) in the TAS1R3 gene, and rs7792845 (T>C) and rs1524600 (C>T) in the the GNAT3 gene. The allele and genotype frequencies of rs307355 and rs35744813 in the TAS1R3 gene showed a significant association between patients with taste disorder (p=0.022 and p=0.013 in both of SNPs, respectively). In addition, the frequency of T-T haplotype in the TAS1R3 gene was higher in taste disorder cases than in the controls (OR, 1.93: 95%. CI, 1.09-3.39, p=0.022). In the GNAT3, the genotype frequency of rs7792845 in the patients was also different from the controls (p=0.048), but allele frequency was not significantly associated in either group. Our result provides the frequencies of SNPs and haplotypes of the TAS1R3 and GNAT3 genes for the fundamental information of nutrigenetics in perception of the taste of sweetness in the Korean population. Also, the study suggests that the allelic polymorphisms of TAS1R3 and GNAT3 genes may be useful as a molecular marker for evaluating patients with taste disorder. Further studies with large samples are required to clarify our observation.