• Title/Summary/Keyword: TAE-RA.

Search Result 734, Processing Time 0.031 seconds

Performance Assessment of Solid Reinforced Concrete Columns with Triangular Reinforcement Details Using Nonlinear Seismic Analysis (비선형 지진해석을 통한 삼각망 철근상세를 갖는 중실 철근콘크리트 기둥의 성능평가)

  • Kim, Tae-Hoon;Ra, Kyeong-Woong;Shin, Hyun-Mock
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.11-20
    • /
    • 2017
  • This study investigates the seismic performance of solid reinforced concrete columns with triangular reinforcement details using nonlinear seismic analysis. The developed reinforcement details are economically feasible and rational, and facilitate shorter construction periods. By using a sophisticated nonlinear finite element analysis program, the accuracy and objectivity of the assessment process can be enhanced. Solution of the equations of motion is obtained by numerical integration using Hilber-Hughes-Taylor (HHT) algorithm. The proposed numerical method gives a realistic prediction of seismic performance throughout the input ground motions for several column specimens. As a result, developed triangular reinforcement details were designed to be superior to the existing reinforcement details in terms of required performance.

A Study on Korean Dependency Parser Using Case Relation and Mutual Information (격 관계와 상호정보를 이용한 한국어 의존 파서)

  • Jung, Seok-Won;Park, Eui-Kyu;Ra, Dong-Yul;Yoon, Jun-Tae
    • Annual Conference on Human and Language Technology
    • /
    • 2001.10d
    • /
    • pp.450-456
    • /
    • 2001
  • 본 논문은 의존 문법에 기반만 한국어의 구문 분석 시스템을 제안한다. 일반적으로 올바른 구둔 구조를 얻기 위해서 많은 가능한 구문 구조를 생성하고 이 중에서 가장 좋은 것을 선택하는 방법을 사용한다. 이를 위하여 가능한 모든 구문 분석 구조를 생성하는 기법을 제안하였다. 이것은 모든 가능한 구문 구조에 관한 정보를 응축한 자료 구조를 구축한 다음 여기에서 구문 트리를 하나씩 추출하도록 하였다. 이 과정에서 의존 문법이 만족하여야 하는 모든 기본적인 제약 조건을 만족하는 트리 만이 효과적으로 추출되는 기법을 제안하였다. 그 결과 생성되는 트리의 수를 줄이게 되어 효율적인 구문 분석을 달성할 수 있게 되었다. 추출된 많은 트리 중에서 하나를 선택하는 작업에서 상호 정보가 이용되었다. 본 논문에서는 이러한 상호 정보를 구문 분석 중의성 해소에 효과적으로 사용하는 기법을 제시하였다. 제안된 기법의 타당성을 입증하기 위하여 구문 분석 시스템을 개발하고 여러 문장에 대한 분석을 실험하였다.

  • PDF

Restoring Encyclopedia Title Words Using a Zero Anaphora Resolution Technique (무형대용어 해결 기술을 이용한 백과사전 표제어 복원)

  • Hwang, Min-Kook;Kim, Young-Tae;Ra, Dongyul;Lim, Soojong
    • Annual Conference on Human and Language Technology
    • /
    • 2014.10a
    • /
    • pp.65-69
    • /
    • 2014
  • 한국어 문장의 경우 문맥상 추론이 가능하다면 용언의 격이 생략되는 현상 즉 무형대용어 (zero anaphora) 현상이 흔히 발생한다. 무형대용어를 채울 수 있는 선행어 (명사구)를 찾는 문제는 대용어 해결 (anaphora resolution) 문제와 같은 성격의 문제이다. 이러한 생략현상은 백과사전이나 위키피디아 등 백과사전류 문서에서도 자주 발생한다. 특히 선행어로 표제어가 가능한 경우 무형대용어 현상이 빈번히 발생한다. 백과사전류 문서는 질의응답 (QA) 시스템의 정답 추출 정보원으로 많이 이용되는데 생략된 표제어의 복원이 없다면 유용한 정보를 제공하기 어렵다. 본 논문에서는 생략된 표제어 복원을 위해 무형대용어의 해결을 기반으로 하는 시스템을 제안한다.

  • PDF

Properties of Mirror-surface Grinding for Metal Matrix Ceramic Composites (금속기지 세라믹 복합소재의 경면연삭 가공 특성)

  • Kwak, Tae-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.1
    • /
    • pp.90-94
    • /
    • 2012
  • This study has been focused on properties of mirror surface grinding technology by ELID(Electrolytic In-process Dressing) for metal matrix ceramic composites using in high precision mirror for optics. The experimental studies have been carried out to get mirror surface by grinding for composites, Al-SiC, Al-graphite and Mg-SiC. Grinding process is carried out with varying abrasive mesh type, depth of cut and feed rate using diamond wheel. The machining result of the surface roughness and condition of ground surface, have been analyzed by use of surface roughness tester and SEM measurement system. ELID grinding technology could be applied successfully for the mirror-surface manufacturing processes in spite of ductility of metal matrix material. As the results of experiments, surface roughness of Al-SiC(45 wt%) has been the most superior in these experimental work-pieces as 0.021 ${\mu}m$ Ra.

Least Mean Square Estimator for Motor Frequency Measurement Based on Linear Hall Sensor (선형 홀센서 기반의 모터 회전속도 측정을 위한 평균 최소 자승 추정기)

  • Choi, Ga-Hyoung;Ra, Won-Sang;Kwak, Ki-Seok;Yoon, Tae-Sung;Park, Jin-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.866-874
    • /
    • 2008
  • Motor frequency can be measured by a hall sensor. Among the many hall sensors, a linear type hall sensor is good at high accuracy frequency measuring problem. However, in general, this linear type hall sensor has DC offset which can vary along sensor's operating voltage change. Therefore, In motor frequency measurement problem using the linear hall sensor, it needs an estimator that can estimate frequency and DC offset simultaneously. In this paper, we propose the least mean square estimator to estimate motor frequency. To verify its performance, we compare the LMS estimator with a commercial analog tachometer. Experimental results shows the proposed LMS estimator works well in varying frequency and stationary DC offset.

Humanoid Robot Control Using Marionette-type Motion Conversion (마리오네트 타입 인간 동작 변환 기법을 이용한 휴머노이드 로봇 제어)

  • Yoo, Jung-Min;Ra, Sung-Kwon;Kim, Eun-Tae;Kim, Chang-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1801-1802
    • /
    • 2008
  • 마리오네트는 끝단에 연결된 줄을 이용하여 사용자가 제어 할 수 있는 인형이다. 본 연구는 마리오네트 원리를 적용하여 인간의 동작을 통해 로봇을 직접 제어할 수 있는 방법을 제안한다. 이를 위해 인간 손과 로봇 손의 사이에 가상의 줄(Virtual Elastic strip)이 연결되어 있는 모델을 사용한다. 실시간으로 측정되는 인간의 동작에 따라 가상 줄의 길이가 변하게 되고 가상 힘이 발생된다. 이 가상 힘을 고려하여 로봇 팔의 정동역학(Forward dynamics) 해를 구한 후, 제어를 위한 로봇의 각 관절값을 얻게 된다. 제안한 방법을 이용하여 인간 동작을 실시간으로 가상 로봇의 동작으로 변환하고 제어하는 실험을 수행하였다.

  • PDF

Integrated microfluidic device with polymer-based micropump and microvalve for $\mu$-TAS devices (마이크로 펌프, 밸브가 집적된 폴리머 기반의 미세 유체제어 시스템의 기계적 특성 강화)

  • Ra, Gyu-Sik;Jha, Sandeep Kumar;Yoon, Tae-Sik;Lee, Hyun-Ho;Kim, Yong-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1458-1459
    • /
    • 2008
  • 미세 유체 제어 시스템 (마이크로 펌프, 마이크로 밸브, 마이크로 채널, 마이크로 믹서 등)의 집적은 화학 및 바이오 유체를 제어하는 Lab-on-a-chip 의 일부분으로서 사용되며 이러한 시스템의 집적은 Lab-on-a-chip 개발을 위해 필수적으로 요구된다. 본 논문에서는 이러한 microchip을 구현하기 위해서 초미세 유체 제어 소자인 마이크로 펌프와 마이크로 밸브를 같은 기판 위에 Polydimethylsiloxane (PDMS)와 indium tin oxade (ITO)를 사용하여 집적하였다. 그리고 밸브의 반복 작동 시 계속적인 유량의 감소를 줄이기 위해 PDMS 의 혼합비를 달리하여 PDMS membrane 의 기계적 특성을 강화시켰다.

  • PDF

The natural convection in a three dimensional enclosure using color capturing technique and computation (색상 포착 기법과 수치계산을 이용한 3차원 밀폐 공간내의 자연대류 연구)

  • Lee, Gi-Baek;Kim, Tae-Yeong;Yang, Jang-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.12
    • /
    • pp.1595-1607
    • /
    • 1997
  • The natural convection of a horizontal layer heated from below in a three-dimensional rectangular enclosure was dealt with both numerically and experimentally. The aspect ratios are 1:2:3.5 and Boussinesq fluid is water with the Prandtl number of 5.0. This experimental study showed how to measure the variation of temperature field in a 3-D rectangular enclosure with small aspect ratios by using TLC(Thermochromic Liquid Crystal) and color capturing technique. The experimental temperature field had periodic characteristics of 75 sec at Ra=2.37*10$^{5}$ . But the numerical convection flow had periodic characteristics of 79 sec at the same Rayleigh number. In three dimensional computation it was found that the convection roll structure bifurcated from four rolls to two rolls as the Rayleigh number is increased.

장기간에 걸친 교정정수의 변화에 의한 원통형이온함의 안정성에 관한 연구

  • Ra, Jeong-Eun;Sin, Dong-O;Kim, Gwi-Ya;Jeong, Hui-Gyo;Seo, Tae-Seok
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.96-99
    • /
    • 2005
  • 본 연구에서는 식품의약품안전청의 도움을 받아 1998년부터 2003년까지 장기간에 걸친 교정정수의 분석을 통한 원통형이온함의 모델별 안정성을 확인하여 보다 효율적인 이온함의 선택으로 방사선치료기관의 선량측정체계의 정확도 향상에 기여하고자 한다. 방사선치료기관에서 사용하고 있는 Farmer형의 원통형이온함에 대한 에어커마 교정정수(NK)를 분석한 결과 Wellhofer FC65G (IC70)와 PTW 30001, 30013 (30006) 그리고 NE 2571 이온함 모델에 대한 교정정수는 모두 0.3%이내에서 잘 일치하였다. 또한 에어커마 교정정수를 이용하여 계산된 물 흡수선량 교정정수(Cal. ND,W)와 실제 측정에 의해 결정된 물 흡수선량 교정정수(Mea. ND,W)를 비교한 결과는 약 1.0% 정도 측정에 의한 교정정수가 높게 나타났으며 에어커마 교정정수를 분석한 결과와 마찬가지로 위 동일한 모델의 이온함에 대해서 측정의 표준편차가 0.14~0.17%로 나타나 장기적인 안정성이 입증되었다.

  • PDF