• Title/Summary/Keyword: TACS

Search Result 33, Processing Time 0.032 seconds

An Analysis of the Effects in the TAC System by Analyzing Catch of TAC Target Species (TAC 어종의 어획량 분석을 통한 TAC 제도의 효과 분석)

  • Sim, Seonghyun;Lee, Jungsam;Oh, Seoyeon
    • Ocean and Polar Research
    • /
    • v.42 no.2
    • /
    • pp.157-169
    • /
    • 2020
  • This study aimed to analyze the effect of total allowable catches (TACs) on the target species. First to effects analyse of TACs, the 8 TAC target species and 75 non-target species were selected for which catch data were available before and after the introduction of the TACs. The 8 target species were simply compared to catch changes before and after TACs. Through the comparison, it was confirmed how the catches of target fishes have changed after the implementation of the TACs. Secondly, the Difference In Differences(DID) analysis was conducted to confirm the effects of the TACs on the catches of the target fishes using the catch data of 8 TAC target species and 75 non-TAC species. Finally, to overcome the limitations of the DID analysis, the random effects model was estimated to confirm the effects of the TACs on the catch of the TAC target species. Overall, this study confirmed that the TACs affects catches of target species, not only through simple comparisons of catches before and after the introduction of the TACs but also through econometric analysis.

Steady and Transient State Analysis on Three Phase-in One Enclosure Type HTS Cable (3상 일괄형 Pipe Type HTS 케이블의 정상 및 과도상태 해석)

  • Jang, Ju-Yeong;Lee, Jong-Beom;Kim, Yong-Kap
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1748-1753
    • /
    • 2010
  • This paper suggests an improved technique to establish the modeling regarding steady and transient state on three phase-in one cryostat type HTS(High Temperature Superconducting) cable. The proposed modeling is established using EMTP/ATPDraw and TACS and MODELS provided by that. It has higher accuracy than the conventional method, as the actual HTS cable is modelled. Steady and transient state analysis performed by EMTP/ATPDraw calculate the current of conductor, shield and former, respectively. In case of the transient state modeled quench state occurred by a single line-to-ground fault, current of conductor shield and former are also calculated, respectively. Especially, various fault resistances and angles are considered to improve the reliability during transient state analysis. Analysis results reveal that the proposed technique improves the accuracy of modeling.

The Lightning Current Parameters that Impact on the Surge Analysis of the EHV Gas Insulated Substation by EMTP

  • Shim Eung-Bo;Han Sang-Ok
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.1
    • /
    • pp.1-7
    • /
    • 2005
  • This paper describes the lightning surge analysis model of extra high voltage GIS using EMTP. Various lightning current parameters were investigated in order to confirm the impact on the lightning surge analysis such as lightning current amplitude, waveform, size of GIS, tower footing resistance and surge arresters. The multi-story tower model and EMTP/TACS model were introduced for the simulation of dynamic arc characteristics. The margin between the maximum overvoltage and BIL of the GIS was about 10 percent and the margin between the maximum overvoltage and BIL of the transformer was 21 percent.

An Electric Arc Furnaces Load Model for Transient Analysis (과도현상 해석을 위한 EAFs 부하 무델의 개발)

  • Jang, Gilsoo;Venkata, S.S.;Kwon, Sea-Hyuk
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.3
    • /
    • pp.197-202
    • /
    • 1999
  • Electric arc furnaces (EAFs) use bulk electrical energy to create heat in metal refining industries. The electric arc process is a main cause of the degradation of the electric power quality such as voltage flicker due to the interaction of the high demand currents of the load with the supply system impedance. The stochastic models have described the aperiodic physical phenomena of EAFs. An alternative approach is to include deterministic chaos in the characterization of the arc currents. In this parer, a chaotic approach to such modeling is described and justified. At the same time, a DLL(Dynamic Link Library) module, which is a FORTRAN interface with TACS (Transient Analysis of Control Systems), is developed to implement the chaotic load model in the Electromagnetic Transients Program (EMTP). The details of the module and the results of tests performed on the module to verify the model and to illustrate its capabilities are presented in this paper.

  • PDF

New capacitor switching schemes to control subsynchronous resonance (SSR을 제어하기 위한 새로운 캐패시터 스위칭방법에 관한 연구)

  • 이훈구;이승환;강승욱;한경희;정연택
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.1
    • /
    • pp.67-73
    • /
    • 1996
  • Subsynchronous resonance(SSR) causes a torsional shaft torque on the generator. Damages resulting from the uncontrolled SSR have resulted in the breakdown in the shaft and costs for replacement power. This paper is to determine the feasibility of controlling SSR by the fast modulation of series compensation capacitors. The presence of subsynchronous currents in the system was detected by a subsynchronous relay which was modeled by the transient analysis of control systems(TACS) in electromagnetic transients program (EMTP). The capacitor segments were switched by bi-directional thyristor switches. These were modeled into EMTP. The strategy to switch the capacitors were modeled as a closed loop system. The paper proves that effective control of SSR can be obtained only by the detuning of the system and the removal or blocking of subsynchronous energy from the system. (author). refs., figs., tabs.

  • PDF

Implementation of HSGS-Adaptive Reclosing Scheme for EHV Transmission System using EMTP/TACS (EMTP/TACS를 이용한 초고압선로 HSGS-적응재폐로 방식의 구현)

  • Choi, Bo-Soo;Chae, Myung-Seck;Yim, Han-Suck;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.106-108
    • /
    • 1996
  • This paper presents the Implementation and performance simulation of HSGS(High Speed Ground Switch)-Adaptive scheme for EHV transmission. EMTP/TACS(Transient Analysis of Control System) functions are combined and used for the implementation and simulation. The simulation results are compared with those for the conventional reclosing scheme and discussed.

  • PDF

Quantification of Myocardial Blood flow using Dynamic N-13 Ammonia PET and factor Analysis (N-13 암모니아 PET 동적영상과 인자분석을 이용한 심근 혈류량 정량화)

  • Choi, Yong;Kim, Joon-Young;Im, Ki-Chun;Kim, Jong-Ho;Woo, Sang-Keun;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.316-326
    • /
    • 1999
  • Purpose: We evaluated the feasibility of extracting pure left ventricular blood pool and myocardial time-activity curves (TACs) and of generating factor images from human dynamic N-13 ammonia PET using factor analysis. The myocardial blood flow (MBF) estimates obtained with factor analysis were compared with those obtained with the user drawn region-of-interest (ROI) method. Materials and Methods: Stress and rest N-13 ammonia cardiac PET imaging was acquired for 23 min in 5 patients with coronary artery disease using GE Advance tomograph. Factor analysis generated physiological TACs and factor images using the normalized TACs from each dixel. Four steps were involved in this algorithm: (a) data preprocessing; (b) principal component analysis; (c) oblique rotation with positivity constraints; (d) factor image computation. Area under curves and MBF estimated using the two compartment N-13 ammonia model were used to validate the accuracy of the factor analysis generated physiological TACs. The MBF estimated by factor analysis was compared to the values estimated by using the ROI method. Results: MBF values obtained by factor analysis were linearly correlated with MBF obtained by the ROI method (slope = 0.84, r = 0.91), Left ventricular blood pool TACs obtained by the two methods agreed well (Area under curve ratio: 1.02 ($0{\sim}1min$), 0.98 ($0{\sim}2min$), 0.86 ($1{\sim}2min$)). Conclusion: The results of this study demonstrates that MBF can be measured accurately and noninvasively with dynamic N-13 ammonia PET imaging and factor analysis. This method is simple and accurate, and can measure MBF without blood sampling, ROI definition or spillover correction.

  • PDF

A Study on Multi-Phase Flashover in 765kV Transmission Line using EMTP (EMTP를 이용한 765kV 송전선로 다상 섬락에 관한 연구)

  • Ka, B.H.;Min, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1586-1588
    • /
    • 1998
  • To use the EMTP, in this paper, a arcing horn is simulated by non-linear resistor and inductor element using TACS, a tower by distributed parameter model, and lines as K. C. Lee model. Changing lightning current characteristics, lightning position, and tower footing resistor value, we analysis multi-phase flashover characteristics in 765 kV transmission line.

  • PDF

EMTP Simulation of Bipolar HVDC System (바이폴 HVDC 시스템의 EMTP 시뮬레이션)

  • Kwak, Joo-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1053-1055
    • /
    • 1998
  • Using EMTP model which describes bipolar HVDC system, switching level simulation results are presented in this paper. Voltage synchronization at point of common coupling, gate pulse generation and current control loops are represented in TACS module. The system consists of 100 km submarine cable rated 300 MW and 12 pulse rectifier and inverter stations which are connected to equivalent three-phase sources and loads through the 154 kV AC lines, respectively. In convertor stations, harmonic filters and capacitor banks are equipped to cancel out the harmonics generated by converters and to supply the required reactive power.

  • PDF

Analysis of Hemodynamic Change in Diffuse Hepatocellular Diseases (미만성 간질환에서의 간혈류 동태의 분석에 관한 연구)

  • Lee, Sung-Yong;Chung, Soo-Kyo;Lee, Yung-Il;Kim, Jong-Woo;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.2
    • /
    • pp.53-59
    • /
    • 1986
  • Radionuclide angiography of the liver and spleen with rapid bolus injection of 5 mCi of $^{99m}Tc-Sn-phytate$ was performed for evaluation of dynamic flow change of the liver in 5 normal subjects and 11 patients with diffuse hepatocellular diseases. And quantification of hepatic arterial index (HAI) was generated from those TACs of the liver and compared with HAI generated from hepatic TAC with injection of $^{99m}Tc-TcO_4^-$ as previously reported method by former investigators, 67 patients with diffuse hepatocellular diseases undergoing hepatic scintigraphy were also evaluated by 2 minutes-hepatosplenic scintiangiography with 5 mCi of $^{99m}Tc-phytate$ and followed injection of 7 mCi of $^{99m}Tc-TcO_4^-$. Those heaptic and splenic TACs were analysed and compared with HAIs of 99m Tc-phytate for evaluation of relative change (%) of count at 30 seconds and 1 minuite after peaks of rapid influx phase to the peaks (100%) in T ACs of $^{99m}Tc-phytate$ and at 1 minuite and 3 minuites after in 5 minuite-TAC of $^{99m}Tc-TcO_4^-$. Correlation between HAIs with $^{99m}Tc-phytate$ and $^{99m}Tc-TcO_4^-$ was highly significant (R=0,984, P=0), and there was most significant and useful correlation (R=0,708, p<0.0001) between HAI and splenic TAC generated by $^{99m}Tc-phytate$.

  • PDF