• Title/Summary/Keyword: T2값

Search Result 2,408, Processing Time 0.036 seconds

MR T2 Map Technique: How to Assess Changes in Cartilage of Patients with Osteoarthritis of the Knee (MR T2 Map 기법을 이용한 슬관절염 환자의 연골 변화 평가)

  • Cho, Jae-Hwan;Park, Cheol-Soo;Lee, Sun-Yeob;Kim, Bo-Hui
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.298-307
    • /
    • 2009
  • By using the MR T2 map technique, this study intends, first, to measure the change of T2 values of cartilage between healthy people and patients with osteoarthritis and, second, to assess the form and the damage of cartilage in the knee-joint, through which this study would consider the utility of the T2 map technique. Thirty healthy people were selected based on their clinical history and current status and another thirty patients with osteoarthritis of the knee who were screened by simple X-ray from November 2007 to December 2008 were selected. Their T2 Spin Echo (SE hereafter) images for the cartilage of the knee joint were collected by using the T2 SE sequence, one of the multi-echo methods (TR: 1,000 ms; TE values: 6.5, 13, 19.5, 26, 32.5. 40, 45.5, 52). Based on these images, the changes in the signal intensity (SI hereafter) for each section of the cartilage of the knee joint were measured, which yielded average values of T2 through the Origin 7.0 Professional (Northampton, MA 01060 USA). With these T2s, the independent samples T-test was performed by SPSS Window version 12.0 to run the quantitative analysis and to test the statistical significance between the healthy group and the patient group. Closely looking at T2 values for each anterior and lateral articular cartilage of the sagittal plane and the coronal plane, in the sagittal plane, the average T2 of the femoral cartilage in the patient group with arthritis of the knee ($42.22{\pm}2.91$) was higher than the average T2 of the healthy group ($36.26{\pm}5.01$). Also, the average T2 of the tibial cartilage in the patient group ($43.83{\pm}1.43$) was higher than the average T2 in the healthy group ($36.45{\pm}3.15$). In the case of the coronal plane, the average T2 of the medial femoral cartilage in the patient group ($45.65{\pm}7.10$) was higher than the healthy group ($36.49{\pm}8.41$) and so did the average T2 of the anterior tibial cartilage (i.e., $44.46{\pm}3.44$ for the patient group vs. $37.61{\pm}1.97$ for the healthy group). As for the lateral femoral cartilage in the coronal plane, the patient group displayed the higher T2 ($43.41{\pm}4.99$) than the healthy group did ($37.64{\pm}4.02$) and this tendency was similar in the lateral tibial cartilage (i.e., $43.78{\pm}8.08$ for the patient group vs. $36.62{\pm}7.81$ for the healthy group). Along with the morphological MR imaging technique previously used, the T2 map technique seems to help patients with cartilage problems, in particular, those with the arthritis of the knee for early diagnosis by quantitatively analyzing the structural and functional changes of the cartilage.

  • PDF

수세법과 pH 조절법에 의한 닭가슴살 surimi의 품질 특성

  • Park, Gi-Hun;Kim, In-Jin;Ha, Ji-Hui;Gang, Seok-Mo;Kim, Il-Seok;Jin, Sang-Geun
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2005.05a
    • /
    • pp.155-158
    • /
    • 2005
  • 닭가슴살을 이용해서 수리미 제조 시 4회 수세한 대조구, pH 3.0으로 산 처리한 T1, pH 11.0으로 알카리 처리한 T2로 하여 그 품질 특성을 비교한 결과 일반성분에서 수분, 조단백질과 염용성단백질 및 수율은 대조구에 비하여 pH 조절법으로 한 두 구가 높았으며, 조지방은 T2가 다른 두 구에 비하여 높았다. pH, 보수력, 파괴강도, 변형값은 처리 간에 유의적인 차이를 보이지 않았다. 전단가는 T2가 가장 높고, T1, 대조구 순이었다. $L{\ast}$값은 T2가 다른 두 구보다 낮았으며, $a{\ast}$값은 T1이 다른 두 구에 비하여 낮았다. $b{\ast}$값은 대조구가 가장 높고, T2가 가장 낮았다. 조직감에서 파쇄성 및 경도는 처리 간에 유의적인 차이를 보이지 않았으며, 응집성은 T1이 다른 두 구보다 낮았으며, 탄력성과 부착성은 대조구에 비하여 T1과 T2가 높았다. 검성은 대조구와 T1에 비하여 T2가 높았다. 조직감의 전 항목에서 T2 가 가장 높았다. 관능검사 결과 외관과 맛은 T1이 가장 높고, 대조구가 가장 낮았다. 색, 향, 다즙성, 연도 및 전체적인 기호도는 처리 간에 유의적인 차이가 없었다.

  • PDF

The Comparison of Susceptibility Changes in 1.5T and3.0T MRIs due to TE Change in Functional MRI (뇌 기능영상에서의 TE값의 변화에 따른 1.5T와 3.0T MRI의 자화율 변화 비교)

  • Kim, Tae;Choe, Bo-Young;Kim, Euy-Neyng;Suh, Tae-Suk;Lee, Heung-Kyu;Shinn, Kyung-Sub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.154-158
    • /
    • 1999
  • Purpose : The purpose of this study was to find the optimum TE value for enhancing $T_2^{*}$ weighting effect and minimizing the SNR degradation and to compare the BOLD effects according to the changes of TE in 1.5T and 3.0T MRI systems. Materials and Methods : Healthy normal volunteers (eight males and two females with 24-38 years old) participated in this study. Each volunteer was asked to perform a simple finger-tapping task (sequential opposition of thumb to each of the other four fingers) with right hand with a mean frequency of about 2Hz. The stimulus was initially off for 3 images and was then alternatively switched on and off for 2 cycles of 6 images. Images were acquired on the 1.5T and 3.0T MRI with the FLASH (fast low angle shot) pulse sequence (TR : 100ms, FA : $20^{\circ}$, FOV : 230mm) that was used with 26, 36, 46, 56, 66, 76ms of TE times in 1.5T and 16, 26, 36, 46, 56, 66ms of TE in 3.0T MRI system. After the completion of scan, MR images were transferred into a PC and processed with a home-made analysis program based on the correlation coefficient method with the threshold value of 0.45. To search for the optimum TE value in fMRI, the difference between the activation and the rest by the susceptibility change for each TE was used in 1.5T and 3.0T respectively. In addition, the functional $T_2^{*}$ map was calculated to quantify susceptibility change. Results : The calculated optimum TE for fMRI was $61.89{\pm}2.68$ at 1.5T and $47.64{\pm}13.34$ at 3.0T. The maximum percentage of signal intensity change due to the susceptibility effect inactivation region was 3.36% at TE 66ms in 1.5T 10.05% at TE 46ms in 3.0T, respectively. The signal intensity change of 3.0T was about 3 times bigger than of 1.5T. The calculated optimum TE value was consistent with TE values which were obtained from the maximum signal change for each TE. Conclusion : In this study, the 3.0T MRI was clearly more sensitive, about three times bigger than the 1.5T in detecting the susceptibility due to the deoxyhemoglobin level change in the functional MR imaging. So the 3.0T fMRI I ore useful than 1.5T.

  • PDF

First Report on External Quality Assurance Study of Radioassay of Thyroid Related Hormones - First One Year of Operation From 1989. 9 To 1990. 8- (갑상선 호르몬의 외부정도 관리 분석 -1989년 9월부터 1990년 8월까지 첫해 시행 결과-)

  • Lee, Dong-Soo;Cho, Bo-Youn;Kwark, Cheol-Eun;Seo, Il-Taek;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.266-279
    • /
    • 1991
  • 1989년 9월부터 1990년 8월까지 국제 원자력기구의 지역 계획에 의해 국내 26개 (후반부 31개)의 기관이 참가하여 T3, T4, TSH를 측정하여 결과를 모으고, 외부정도관적를 시행한 결과가 다음과 같다. 1) 외부정도관리를 위한 컴퓨터 소프트웨어를 작성하였다. 데이타의 입력, 정도 분석, 월별 보고, 분기별 보고 및 수행 분석 프로그램을 만들되 전체 검사실결과에서 추린 평균값(all laboratories trimmed mean: ALTM)으로 모집단평균을 삼아 편차, 편이, 편이평균 그리고 이들의 경시적 변화를 분석하도록 하였다. 2) 전후반 2회에 나누어 만든 및치 사이의 편차는 유의하지 않았다. T3값의 변이계수는 7.2%이하(정상 T3 값) 또는 9.2%와 13.4%사이 (높은 T3 값), 74 값의 변이계수는 4.6%이하(정상 또는 높은 T4값), 5.4%와 9.5%사이(낮은 T4값)이었다. TSH는 정상범위 값에서 21.7%이하의 변이 계수를 보였고 정상보다 낮거나 높은 TSH의 풀은 8 7%와 21.2%사이의 변이제수를 보였다. 3) 전체 검사실 추린 평균값(ALTM)에 따른 변이계수의 변동은, ALTM이 정상 T4값범위일 때 변이계수는 15%이하이었고, 낮은 T4값일 때는 중간값이 15%이고 분포범위는 50%까지이었다. T3값의 변이계수는 대체로 20%이하이었다. TSH의 변이계수는 1mU/L를 전후로 급격히 상승하여 200%에 달하였다. 4) 3표준편차보다 높거나 낮은 값을 보인 검사실들의 분포는 전체 검사실결과에서 추린 평균값(ALTM)과 상관없었다. 5) 첨가한 T3, T4, TSH에 대한 회수율은 T4는 104, 106%, T3는 67%, 74%, TSH는 87%, 86%이었다. 이상과 같이, 저자들이 만든 소프트웨어 프로그램으로 외부정도관리를 위하여 쉽게 데이터를 분석하고 보고서를 작성하여 갑상선호르몬의 경사신뢰도를 평가할 수 있게 되었으며, 위에 요약한 첫 해의 외부정도관리 결과를 바탕으로 참가기관의 동의하에, 앞으로 정도관리 항목의 확대와 외부정도관리의 지속적인 시행이 바람직하다고 생각하였다.

  • PDF

A Study on the Effectiveness of Horticultural Therapy on the Emotional Stability of Children From Broken Homes (원예심리치료가 결손가정아동의 정서적 안정에 미치는 효과성에 관한 연구)

  • Kang, Jong-Gu;Lee, Nam-Sug
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1628-1636
    • /
    • 2011
  • The purpose of this study is to analyze the effectiveness of horticultural therapy on children from broken homes: this treatment program, implemented in the social welfare field, targets the children's depression, self-esteem, and social and emotional stress. Its object was composed of 13 lower grade students enrolled in special facilities according to the life-cycle method, and its data were collected as making use of the structured questionnaire. The horticultural Therapy Program was practiced 14 sessions in total from September 2nd to December 16th, 2010, and its results in summary are as follows; The sociality in horticultural therapy was higher by .53 point in 2.76 after practice than in 2.23 before practice, and its value of the ability to cope with stress was higher by 0.52 point in 2.82 after coping with stress than in 2.30 before that. That was meaningful (t=-1.4398, p<.05). The value of anxiety was lower by .15 in 1.45 post-anxiety than in 1.60 pre-anxiety, and that was meaningful (t=-2.3842, p<.05). The value of self-esteem is higher by .42 in 2.92 post-self-esteem than in 2.50 pre-self-esteem, and that was strategically meaningful (t=-1.1871, p<.05). The value of emotional assessment was higher by 2.05 in 5.25 post-emotional assessment than in 3.20 pre-emotional assessment, and that was strategically meaningful (t=-2.4599, p<.05). Based on these results, this study suggests that this horticultural therapy program should apply to the issues of children in social welfare field as one of various approaches.

Study of Contrast Sensitivities using Polarizer-Transmittance (편광 투과율을 이용한 대비 민감도(Cs) 특성 연구)

  • Park, Sang-An;Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.59-63
    • /
    • 2001
  • Using the rotation of two polarizer plate and the area of transmittance In the visual light region measured by spectrophotometer, we obtained the luminance to measure the Contrast Sensitivity, and calculated the values of $L_{min}$ and ${\theta}_{min}$ after fixed the average contrast, $L_{max}$ and ${\theta}_{max}$ values from the values of two contrasts. Then, when it was fixed by $L_{max}=4000(T%nm)$ and ${\theta}_{max}=44.1^{\circ}$, $L_{min}$ and ${\theta}_{min}$ values were respectively given by 1333, 2666, 3920(T%nm) and 56.6, 54.3, $45^{\circ}$ in Cs values of 2.5, 100.

  • PDF

Effects of Addition of Pine Needle Extracts in Different Forms on the Antioxidant and Residual Nitrite Contents of Emulsified Sausages during Cold Storage (제조 방법이 다른 솔잎 추출물 첨가가 유화형 소시지의 냉장 저장 중 항산화 및 아질산염 잔존량에 미치는 영향)

  • Kim, Young-Jik
    • Food Science of Animal Resources
    • /
    • v.31 no.1
    • /
    • pp.74-80
    • /
    • 2011
  • The objective of this study was to determine the shelf-life effects and residual nitrite content of emulsified sausages added with pine needles during cold storage. The sausage consisted of four types: no pine needles added (control), pine needle juice added (T1), ethanol extract of pine needles added (T2), and boiling extract of pine needles added (T3). Each sausage type was tested in triplicate and assigned to one of four storage periods: 0, 10, 20, or 30 d. As storage time increased, the presence of pine needles resulted in decreased pH, meat color (CIE $L^*$, $a^*$ and $b^*$), residual nitrite value, and increased thiobarbituric acid reactive substances (TBARS) values and total plate counts (TPC). Values for pH, TBARS, residual nitrite, total plate counts and CIE $L^*$ and $a^*$ decreased significantly with added pine needles relative to the control (p<0.05). In particular, T2 was significantly (p<0.05) more effective for delaying lipid oxidation than the other treatment groups. In conclusion, the results demonstrate that adding an ethanol extract of pine needles (T2) to emulsified sausages tended to improve antioxidative and antimicrobial effects and reduce residual nitrite content during storage compared to the other treatment groups.

Effect of the Addition Method of Mugwort on Antioxidant Effect, Total Plate Counts, and Residual Nitrite Content of Emulsified Sausages during Cold Storage (쑥 첨가방법이 유화형 소시지의 냉장 저장 중 항산화, 총미생물수 및 아질산염 소거에 미치는 영향)

  • Kim, Young-Jik
    • Food Science of Animal Resources
    • /
    • v.31 no.1
    • /
    • pp.122-128
    • /
    • 2011
  • This study was conducted to investigate the antioxidant effects, total plate count (TPC), and residual nitrite content of emulsified sausage with added mugwort during cold storage. The sausages were of five types: nothing added (control), mugwort powder added (T1), mugwort juice added (T2), mugwort ethanol extract added (T3), and mugwort hot water extract added (T4). Each sausage type was tested in triplicate and assigned to one of five storage periods: 0, 1, 2, 3, or 4 wk. As storage time increased, the presence of mugwort resulted in decreased pH, residual nitrite content, and meat color (CIE $L^*$ and $b^*$) and increased thiobarbituric acid reactive substance (TBARS) and TPC values. Values for pH, TBARS, residual nitrite, and TPC decreased significantly after adding mugwort compared with the control (p<0.05). Among all treatments, T3 was significantly (p<0.05) more effective in delaying lipid oxidation and microbial activity. The CIE $L^*$ and $b^*$ decreased significantly with the addition of mugwort relative to the control. In conclusion, the results demonstrate that adding an ethanol extract of mugwort (T3) to emulsified sausages tended to improve antioxidant and antimicrobial effects and residual nitrite content during storage compared to the other treatment groups.

Estimation of $T_2{^*}$ Relaxation Times for the Glandular Tissue and Fat of Breast at 3T MRI System (3테슬러 자기공명영상기기에서 유방의 유선조직과 지방조직의 $T_2{^*}$이완시간 측정)

  • Ryu, Jung Kyu;Oh, Jang-Hoon;Kim, Hyug-Gi;Rhee, Sun Jung;Seo, Mirinae;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose : $T_2{^*}$ relaxation time which includes susceptibility information represents unique feature of tissue. The objective of this study was to investigate $T_2{^*}$ relaxation times of the normal glandular tissue and fat of breast using a 3T MRI system. Materials and Methods: Seven-echo MR Images were acquired from 52 female subjects (age $49{\pm}12 $years; range, 25 to 75) using a three-dimensional (3D) gradient-echo sequence. Echo times were between 2.28 ms to 25.72 ms in 3.91 ms steps. Voxel-based $T_2{^*}$ relaxation times and $R_2{^*}$ relaxation rate maps were calculated by using the linear curve fitting for each subject. The 3D regions-of-interest (ROI) of the normal glandular tissue and fat were drawn on the longest echo-time image to obtain $T_2{^*}$ and $R_2{^*}$ values. Mean values of those parameters were calculated over all subjects. Results: The 3D ROI sizes were $4818{\pm}4679$ voxels and $1455{\pm}785$ voxels for the normal glandular tissue and fat, respectively. The mean $T_2{^*}$ values were $22.40{\pm}5.61ms$ and $36.36{\pm}8.77ms$ for normal glandular tissue and fat, respectively. The mean $R_2{^*}$ values were $0.0524{\pm}0.0134/ms$ and $0.0297{\pm}0.0069/ms$ for the normal glandular tissue and fat, respectively. Conclusion: $T_2{^*}$ and $R_2{^*}$ values were measured from human breast tissues. $T_2{^*}$ of the normal glandular tissue was shorter than that of fat. Measurement of $T_2{^*}$ relaxation time could be important to understand susceptibility effects in the breast cancer and the normal tissue.

A Study on the C.T.I in Phenolic Resin (Phenolic Resin의 C.T.I에 관한 연구)

  • 이보호;박동화
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.1 no.2
    • /
    • pp.62-69
    • /
    • 1987
  • In the thesis research on the C.T.I for the borne by tracking phenolic resin, electolytic errosion appearance of electrode materials causes the part of electrode to increase the failure of tracking. $\circled1$ In the material of insulation in which C.T.I has 350 degree or so, We can obtain the constant value by Cu.Zn electrode than Pt electrode. $\circled2$ C.T.I value has noting to do with resistance rate of electrolyte. $\circled3$ As the contact angle of interface grow, the starting electric stress of corona and the value of C.T.I increase.