• Title/Summary/Keyword: T1WI

Search Result 220, Processing Time 0.026 seconds

Ultimate-Game Automatic Trace and Analysis System Using IoT (사물인터넷 기반 얼티미트 경기 자동추적 및 분석 시스템)

  • Lim, Jea Yun
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.11 no.1
    • /
    • pp.59-66
    • /
    • 2022
  • In this paper, by applying IoT technology to the Ultimate game, which is one of the games using Flyingdisc, the process of the game is traced based on the players and the flyingdisc, and a comprehensive relationship analysis between players is performed on the results of the game. A WiFi module with built-in GPS is attached in the players and flyingdisc. The player's ID, latitude/longitude values received from GPS and time are stored in the database in realtime during the game. Process informations of the game is also stored in the database at the same time using mobile Ultimate game App. Based on this informations after the game is over, we developed a system that can perform comprehensive analysis of the game contents. By using the informations stored in the database, the player-based game process and the flyingdisc-based scoring process are visualized in the virtual playground. Various game result informations for players are graphically analyzed using Python.

Design and Manufacture of Triple-Band Antennas with Modified Rectangular Ring and Rectangular Patch for WLAN/WiMAX system applications (변형된 사각 링과 사각 패치를 갖는 WLAN/WiMAX 시스템에 적용 가능한 삼중대역 안테나 설계 및 제작)

  • Kim, Woo-Su;Yoon, Joong-Han
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.3
    • /
    • pp.341-348
    • /
    • 2019
  • In this paper, a monopole type antenna applicable to WLAN and WiMAX standard frequency bands is designed and fabricated. The proposed antenna is designed to have rectangular ring and rectangular patch based on microstrip feeding for triple band characteristics and inserted two stub in the top of the rectangular ring patch to enhance impedance bandwidth characteristics. The proposed antenna has $18.0mm(2W_1+W_2){\times}33.0mm(L_7+L_8+L_9)$ on a dielectric substrate of $27.0mm(W_1){\times}44mm(L_1){\times}1.0mm$ size. From the fabrication and measurement results, impedance bandwidths of 660MHz (2,08 to 2.74GHz) for 2.4/2.5MHz band, 488MHz (3.40 to 3.88GHz) for 3.5MHz band, and 2,180MHz (4.61 to 6.79GHz) for 5,000MHz band were obtained based on the impedance bandwidth. The proposed antenna also obtained the measured gain and radiation pattern in the anechoic chamber.

Implementation of Automotive Multimedia Interface Supporting Multi-Channel Display in Multi-Screen Display (다채널 다중 화면 디스플레이를 지원하는 차량용 멀티미디어 인터페이스 구현)

  • Jeon, Young-Joon;Song, Bong-Gi;Kim, Jang-Ju;Park, Jang-Sik;Yu, Yun-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.1
    • /
    • pp.199-206
    • /
    • 2013
  • Recently, the diverse needs of the drivers for in-vehicle infotainment systems are increasing rapidly. As a result, the infotainment systems are equipped with more convenient and human-friendly high-tech features. In this paper, we designed and implemented in-vehicle multimedia infotainment system based on embedded system that was applied various multimedia to in-vehicles. The proposed system can support independent display on each screen for the multi-channel multimedia source based on one processor(1 CPU). Therefore, our system can be reduced costs compared to other systems. This system not only displays the video and audio data in storage devices but also displays CAM, T-DMB, and DVB-T multimedia contents which are supplied in real-time services. Also, our system could multi-screen displays multimedia data in smart phone using Wi-Fi. We expect that in-vehicle infotainment systems like AVN(Audio video navigation) and RSE(Rear Seat Entertainment) could be used in various applications and reduced costs.

Usefulness of the High B-value DWI in Brain Tumors (뇌종양 확산강조영상에서 High B-value의 유용성 평가)

  • Kim, Jin-tae;Byun, Jae-Hu;Park, Yong-Seong;Lee, Rae-Gon;Hwang, Seon-Kwang
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.33-41
    • /
    • 2015
  • This study attempts to examine the clinical usefulness of High b-value DWI (diffusion weighted imaging) for brain tumors with an edema. Subjects were seven patients selected from 65 patients who received an MRI scan for suspected encephalopathy and confirmed diagnosis at our hospital from February to July 2015 (male: 7, average age : 66 years old). As test equipment, 3.0T MR System (ACHIEVA Release, Philips, Best, The Netherlands) and 8Channel SENSE Head Coill were used. DWI checks on the use of the variable TR 5460ms, TE 132ms, Slice Thickness 4mm, gap 1mm, Slice number 29 is, 3D T1WI is TR 8.4ms, TE 3.9ms, matrix size $240{\times}240$, Slice can set 180 piecesIt was. b value of 0, 1,000, 2,000 s/mm2 with DWI acquisition and 3D T1WI enhancement five minutes after the Slice Thickness 3mm, gap 0mm to reconstruct the upper face axis (MPR TRA CE) was. As for the experiment, in b-value 1,000 and 2,000 images, SNR and the lesion at the lesion site and CNR in the normal site opposite to the lesion are measured. WW(window width) and WL(window level) are made equal in MRICro software, and the volume of the lesion is measured from each of b-value and MPR TRA CE image. Using SPSS ver. 1.8.0.0 Mann Whitney-test was analyzed for SNR and CNR, while Kruskal-Wallis test was analyzed for volume.

  • PDF

Study on the Positioning Method using BLE for Location based AIoT Service (위치 기반 지능형 사물인터넷 서비스를 위한 BLE 측위 방법에 관한 연구)

  • Ho-Deok Jang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.17 no.1
    • /
    • pp.25-30
    • /
    • 2024
  • Smart City, a key application area of the AIoT (Artificial Intelligence of Things), provides various services in safety, security, and healthcare sectors through location tracking and location-based services. an IPS (Indoor Positioning System) is required to implement location-based services, and wireless communication technologies such as WiFi, UWB (Ultra-wideband), and BLE (Bluetooth Low Energy) are being applied. BLE, which enables data transmission and reception with low power consumption, can be applied to various IoT devices such as sensors and beacons at a low cost, making it one of the most suitable wireless communication technologies for indoor positioning. BLE utilizes the RSSI (Received Signal Strength Indicator) to estimate the distance, but due to the influence of multipath fading, which causes variations in signal strength, it results in an error of several meters. In this paper, we conducted research on a path loss model that can be applied to BLE IPS for proximity services, and confirmed that optimizing the free space propagation loss coefficient can reduce the distance error between the Tx and Rx devices.

Intraparenchymal Sylvian Fissure Meningioma

  • Ko, Byung-Su;Jung, Shin;Jung, Tae-Young;Kim, In-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.2
    • /
    • pp.120-122
    • /
    • 2007
  • Meningiomas arise from meningothelial cells that line the arachnoid membrane. So most meningiomas are dural-based lesion. But meningiomas without dural-attachment do occur and are less common. We report our experience of intraparenchymal sylvian fissure menigioma. A 21-year-old female presented with a one-month history of headache that was associated with long-term intermittent partial seizure. CT revealed about $4.5{\times}4.3{\times}5.5cm$ sized calcified mass with enhancement in right temporal lobe. On MR imaging, the lesion was observed in the right temporal lobe that was low-signal intensity on T2WI and iso-signal intensity on T1WI with well enhancement. Operation was performed via right orbitocranial approach. The internal surface of dura was intact. Tumor was totally removed except the capsule of tumor adhered to main trunk of middle cerebral artery. The histopathology showed meningioma, psammomatous type. Intraparenchymal meningioma should be considered in the differential diagnosis of intraaxial lesions in patients of any age group.

Spontaneous Spinal Epidural Hematoma with Intraoperative Acute Massive Bleeding - Case Report - (수술중 급성 대량 출혈을 동반한 자발성 척추경막외혈종 - 증 례 보 고 -)

  • Kim, Hyoung Jong;Hwang, Soo Hyun;Park, In Sung;Kim, Eun-Sang;Jung, Jin-Myung;Han, Jong Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.9
    • /
    • pp.1184-1187
    • /
    • 2000
  • Spontaneous spinal epidural hematoma is rare disease and usually presents with a progressive neurological syndrome for which surgical decompression is usually indicated. The cause of bleeding in epidural hematoma remains unknown in most of the cases. The most frequently identified risk factor is coagulopathy or treatment with anticoagulants. Recently, authors experienced a case of spontaneous spinal epidural hematoma with intraoperative profuse bleeding at the cervicothoracic location. Laboratory examination showed no evidence of coagulopathy or hepatic disease. On neurologic examination, left hemiparesis(Grade : II) and left side sensory change were noted. On MRI scan, there was a mass of high signal intensity in T2WI and isosignal intensity in T1WI compressing the cord to left side. The patients had good surgical outcome after decompressive laminectomy and hematoma removal.

  • PDF

Thermodynamic Performance Analysis of Heat Pump Using Thermoelectric Semiconductor (열전반도체를 이용한 열펌프의 열역학적 성능 해석)

  • 박영무
    • Journal of Energy Engineering
    • /
    • v.2 no.1
    • /
    • pp.95-103
    • /
    • 1993
  • A conceptual thermoelectric heat pump(cooling mode) of small capacity is designed. Its performance is investigated through parametric analysis. COP and cooling capacity decease as the ambient temperature increases with ${\mu}$, J, T$\sub$wi/, fixed. To design a system of fixed capacity comes to calculate ${\mu}$ and J when T$\sub$wi/, and T$\sub$a/ are given. As v is fixed by semi-conductor manufacturers, optimum combination of n and I should be searched for ν. Optimum current could be calculated using ${\mu}$-J curve and optimum value of ${\mu}$. COR$\sub$R/ increases as water flow rate increases and T$\sub$a/ decreases. The effect of heat transfer coefficient at hot(heat releasing) side is more significant than that at cold(heat absorbing) side.

  • PDF

The Comparative Study on the Optimized Images between Spin Echo and Turbo Spin Echo Pulse Sequences in the 1.0 T ; Aspect of T1 Weighted Image in the Brain (SE와 TSE기법의 최적영상에 관한 고찰 (Brain T1WI 측면에서))

  • Cho M.J.;Jeong H.J.;Yoo B.K.;Kim W.S.;Min K.H.;Kim S.R.;Song I.C.
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.95-103
    • /
    • 2001
  • Ⅰ. Purpose : The purpose of this study was to evaluate optimized images of Turbo Spin Echo(TSE) imaging technique in Brain MRI compared with Spin Echo(SE) technique. Ⅱ. Materials and Methods : A retrospective comparison between SE and TSE sequences was pe

  • PDF

Effects of Contrast Agent Concentration on the Signal Intensity and Turbo Factor of TSE and Slice-selective IR in T1-weighted Contrast Imaging

  • Han, Yong Soo;Lee, Soo Chul;Lee, Dong Yong;Choi, Jiwon;Lee, Jong Woong;Kweon, Dae Cheol
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.115-124
    • /
    • 2016
  • The present study analyzes T1 TSE and T1 slice sel. IR (dark_fluid) signal strength according to the degree of gadolinium contrast agent dilution and analyzes the turbo factors with regard to changes in the maximum and overall signal strength to study correlations between changes and signal-to-noise ratios (SNRs) and compare peak-to-peak SNR (PSNR) enhancement in order to improve the quality of T1-weighted images. Enhancement TR (600 msec) evaluated to determine the T1 TSE turbo factor and obtain the maximum signal strength, T1WI were used sequentially to experiment with turbo factors_1-4. T1 slice sel. IR (dark-fluid) was used to sequentially test turbo factors_2-5 but not turbo factor_1 at a TR (1500 msec) and compare data at an increase in T1 of 900 msec. The T1 TSE was reduced according to the contrast agent concentration. Phantom signal strength increased, whereas turbo factors_1-4 exhibited maximum signal strength at a concentration of 3 mmol, followed by a gradual decrease. In the turbo factors_2-5, the signal strength increased sharply to maximum signal strength at 0.7 mmol, followed by a reduction. T1 TSE had a greater maximum signal strength than did T1 slice sel. IR (dark_fluid). A comparison of SNR found that T1 TSE imaging was superior (33.3 dB) in turbo factor_1 and T1 slice sel. IR (dark_fluid) was highest (33.9 dB) at turbo factor_5. A PSNR comparison analysis was not sufficient to distinguish between the images obtained with both techniques at 30 dB or higher under all experimental conditions.