• 제목/요약/키워드: T1 dynamic contrast enhanced imaging

검색결과 26건 처리시간 0.024초

관류자기공명영상의 이해 (Understanding of Perfusion MR Imaging)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제15권1호
    • /
    • pp.27-31
    • /
    • 2013
  • Perfusion MR imaging is how to use exogenous and endogenous contrast agent. Exogenous perfusion MRI methods which are dynamic susceptibility contrast using $T2^*$ effect and dynamic contrast-enhanced using T1 weighted image after injection contrast media. An endogenous perfusion MRI method which is arterial spin labeling using arterial blood flow in body. In order to exam perfusion MRI in human, technical access are very important according to disease conditions. For instance, dynamic susceptibility contrast is used in patients with acute stroke because of short exam time, while dynamic susceptibility contrast or dynamic contrast enhancement provides the various perfusion information for patients with tumor, vascular stenosis. Arterial spin labeling is useful for children, women who are expected to be pregnant. In this regard, perfusion MR imaging is required to understanding, and the author would like to share information with clinical users

  • PDF

Application of T1 Map Information Based on Synthetic MRI for Dynamic Contrast-Enhanced Imaging: A Comparison Study with the Fixed Baseline T1 Value Method

  • Dong Jae Shin;Seung Hong Choi;Roh-Eul Yoo;Koung Mi Kang;Tae Jin Yun;Ji-Hoon Kim;Chul-Ho Sohn;Sang Won Jo;Eun Jung Lee
    • Korean Journal of Radiology
    • /
    • 제22권8호
    • /
    • pp.1352-1368
    • /
    • 2021
  • Objective: For an accurate dynamic contrast-enhanced (DCE) MRI analysis, exact baseline T1 mapping is critical. The purpose of this study was to compare the pharmacokinetic parameters of DCE MRI using synthetic MRI with those using fixed baseline T1 values. Materials and Methods: This retrospective study included 102 patients who underwent both DCE and synthetic brain MRI. Two methods were set for the baseline T1: one using the fixed value and the other using the T1 map from synthetic MRI. The volume transfer constant (Ktrans), volume of the vascular plasma space (vp), and the volume of the extravascular extracellular space (ve) were compared between the two methods. The interclass correlation coefficients and the Bland-Altman method were used to assess the reliability. Results: In normal-appearing frontal white matter (WM), the mean values of Ktrans, ve, and vp were significantly higher in the fixed value method than in the T1 map method. In the normal-appearing occipital WM, the mean values of ve and vp were significantly higher in the fixed value method. In the putamen and head of the caudate nucleus, the mean values of Ktrans, ve, and vp were significantly lower in the fixed value method. In addition, the T1 map method showed comparable interobserver agreements with the fixed baseline T1 value method. Conclusion: The T1 map method using synthetic MRI may be useful for reflecting individual differences and reliable measurements in clinical applications of DCE MRI.

Development of 3D Mapping Algorithm with Non Linear Curve Fitting Method in Dynamic Contrast Enhanced MRI

  • Yoon Seong-Ik;Jahng Geon-Ho;Khang Hyun-Soo;Kim Young-Joo;Choe Bo-Young
    • 한국자기공명학회논문지
    • /
    • 제9권2호
    • /
    • pp.93-102
    • /
    • 2005
  • Purpose: To develop an advanced non-linear curve fitting (NLCF) algorithm for dynamic susceptibility contrast study of brain. Materials and Methods: The first pass effects give rise to spuriously high estimates of $K^{trans}$ in voxels with large vascular components. An explicit threshold value has been used to reject voxels. Results: By using this non-linear curve fitting algorithm, the blood perfusion and the volume estimation were accurately evaluated in T2*-weighted dynamic contrast enhanced (DCE)-MR images. From the recalculated each parameters, perfusion weighted image were outlined by using modified non-linear curve fitting algorithm. This results were improved estimation of T2*-weighted dynamic series. Conclusion: The present study demonstrated an improvement of an estimation of kinetic parameters from dynamic contrast-enhanced (DCE) T2*-weighted magnetic resonance imaging data, using contrast agents. The advanced kinetic models include the relation of volume transfer constant $K^{trans}\;(min^{-1})$ and the volume of extravascular extracellular space (EES) per unit volume of tissue $\nu_e$.

  • PDF

Focal nodular hyperplasia: Tripie-contrast enhanced MR imaging using gadolinium chelates, mangafodipir trisodium, and ferumoxides

  • Kim, Joo-Hee;Kim, Myeong-Jin;Park, Young-Nyun;Kim, Kyung-Sik;Lee, Jong-Tae;Yoon, Hyung-Sik
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.140-140
    • /
    • 2001
  • We present two cases of surgically proven focal nodular hyperplasia whou underwent tri contrast-enhance MR imaging using gadolinium chelates, mangafodipir trisodium, and ferumoxides After the unehanced MR images were obtained, dynamic gadolinium-enhanced T1-weighted imagi were performed, then mangafodipir enhanced and ferumoxides-enhanced images were obtained. In one case, the mass was isointense on both T1- and T2-weighted images on the unehanced M images, iso and slightly hyperintense on ferumoxides-enhanced FSE and GRE images, strong hyperintense on the mangafodipir enhanced and gadolinium enhanced arterial phase images. In th other case, the mass was isointense on T2-weighted and hypointense on T1-weighted image isointense on ferumoxides-enhanced images, and hyperintense on mangafodipir enhanced an gadolinium enhanced arterial phase images. Triple contrast enhanced MR images were useful correctly diagnose these two cases preoperatively.

  • PDF

Prognostic Prediction Based on Dynamic Contrast-Enhanced MRI and Dynamic Susceptibility Contrast-Enhanced MRI Parameters from Non-Enhancing, T2-High-Signal-Intensity Lesions in Patients with Glioblastoma

  • Sang Won Jo;Seung Hong Choi;Eun Jung Lee;Roh-Eul Yoo;Koung Mi Kang;Tae Jin Yun;Ji-Hoon Kim;Chul-Ho Sohn
    • Korean Journal of Radiology
    • /
    • 제22권8호
    • /
    • pp.1369-1378
    • /
    • 2021
  • Objective: Few attempts have been made to investigate the prognostic value of dynamic contrast-enhanced (DCE) MRI or dynamic susceptibility contrast (DSC) MRI of non-enhancing, T2-high-signal-intensity (T2-HSI) lesions of glioblastoma multiforme (GBM) in newly diagnosed patients. This study aimed to investigate the prognostic values of DCE MRI and DSC MRI parameters from non-enhancing, T2-HSI lesions of GBM. Materials and Methods: A total of 76 patients with GBM who underwent preoperative DCE MRI and DSC MRI and standard treatment were retrospectively included. Six months after surgery, the patients were categorized into early progression (n = 15) and non-early progression (n = 61) groups. We extracted and analyzed the permeability and perfusion parameters of both modalities for the non-enhancing, T2-HSI lesions of the tumors. The optimal percentiles of the respective parameters obtained from cumulative histograms were determined using receiver operating characteristic (ROC) curve and univariable Cox regression analyses. The results were compared using multivariable Cox proportional hazards regression analysis of progression-free survival. Results: The 95th percentile value (PV) of Ktrans, mean Ktrans, and median Ve were significant predictors of early progression as identified by the ROC curve analysis (area under the ROC curve [AUC] = 0.704, p = 0.005; AUC = 0.684, p = 0.021; and AUC = 0.670, p = 0.0325, respectively). Univariable Cox regression analysis of the above three parametric values showed that the 95th PV of Ktrans and the mean Ktrans were significant predictors of early progression (hazard ratio [HR] = 1.06, p = 0.009; HR = 1.25, p = 0.017, respectively). Multivariable Cox regression analysis, which also incorporated clinical parameters, revealed that the 95th PV of Ktrans was the sole significant independent predictor of early progression (HR = 1.062, p < 0.009). Conclusion: The 95th PV of Ktrans from the non-enhancing, T2-HSI lesions of GBM is a potential prognostic marker for disease progression.

k-t FOCUSS 알고리듬을 이용한 고분해능 4-D MR 혈관 조영 영상 기법 (High Resolution Time Resolved Contrast Enhanced MR Angiography Using k-t FOCUSS)

  • 정홍;김응엽;예종철
    • Investigative Magnetic Resonance Imaging
    • /
    • 제14권1호
    • /
    • pp.10-20
    • /
    • 2010
  • 목적: 최근, 미국 애리조나 세도나에서 열린 국제자기공명학회 (ISMRM) 주관의 2009년 데이터 샘플링과 영상 복원에 관한 워크샵에서 자기공명영상 복원 대회가 열렸다. 이 대회는 time resolved contrast enhanced MR angiography 에 대한 고속 촬영의 실제 활용 가능성을 평가하기 위한 것이었다. 본 논문은 이 대회의 우승 결과를 얻은 k-t FOCUSS 알고리듬을 단계별로 자세히 묘사하도록 한다. 대상 및 방법: 본 그룹은 앞선 연구에서 비교적 덜 스파스한 심장 영상에 대해 k-t FOCUSS 알고리듬이 성공적으로 압축센싱 문제를 풀수 있음을 증명했다. 따라서 k-t FOCUSS 알고리듬을 time resolved contrast enhanced MR angiography 에 적용함으로써, 매우 정확한 영상 복원이 가능할 것이다. 영상 복원을 위해 X-ray 대뇌 혈관조영 영상으로부터 구성된 다운 샘플링된 데이터가 대회 주최측으로부터 공통으로 제시되었고, 방사선과 의사들이 각 복원된 영상에 대한 사전 정보 없이, 원래 영상과 복원된 결과를 비교함으로써, 영상의 질을 평가하였다. 결과: 다양한 다운샘플링에 대해 얻어진 결과들은 영상의 스파스 변환이나 샘플링 형태와 같은 압축센싱의 중요한 요소들에 의해 크게 영향을 받는다는 것을 보여주었다. 결론: 복원된 결과로부터, 압축센싱 동적자기공명영상 기법인 k-t FOCUSS 가 고해상도의 time resolved contrast enhanced MR angiography 를 가능하게 할 수 있음을 확인하였다.

Differentiation between Glioblastoma and Primary Central Nervous System Lymphoma Using Dynamic Susceptibility Contrast-Enhanced Perfusion MR Imaging: Comparison Study of the Manual versus Semiautomatic Segmentation Method

  • Kim, Ye Eun;Choi, Seung Hong;Lee, Soon Tae;Kim, Tae Min;Park, Chul-Kee;Park, Sung-Hye;Kim, Il Han
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권1호
    • /
    • pp.9-19
    • /
    • 2017
  • Background: Normalized cerebral blood volume (nCBV) can be measured using manual or semiautomatic segmentation method. However, the difference in diagnostic performance on brain tumor differentiation between differently measured nCBV has not been evaluated. Purpose: To compare the diagnostic performance of manually obtained nCBV to that of semiautomatically obtained nCBV on glioblastoma (GBM) and primary central nervous system lymphoma (PCNSL) differentiation. Materials and Methods: Histopathologically confirmed forty GBM and eleven PCNSL patients underwent 3T MR imaging with dynamic susceptibility contrast-enhanced perfusion MR imaging before any treatment or biopsy. Based on the contrast-enhanced T1-weighted imaging, the mean nCBV (mCBV) was measured using the manual method (manual mCBV), random regions of interest (ROIs) placement by the observer, or the semiautomatic segmentation method (semiautomatic mCBV). The volume of enhancing portion of the tumor was also measured during semiautomatic segmentation process. T-test, ROC curve analysis, Fisher's exact test and multivariate regression analysis were performed to compare the value and evaluate the diagnostic performance of each parameter. Results: GBM showed a higher enhancing volume (P = 0.0307), a higher manual mCBV (P = 0.018) and a higher semiautomatic mCBV (P = 0.0111) than that of the PCNSL. Semiautomatic mCBV had the highest value (0.815) for the area under the curve (AUC), however, the AUCs of the three parameters were not significantly different from each other. The semiautomatic mCBV was the best independent predictor for the GBM and PCNSL differential diagnosis according to the stepwise multiple regression analysis. Conclusion: We found that the semiautomatic mCBV could be a better predictor than the manual mCBV for the GBM and PCNSL differentiation. We believe that the semiautomatic segmentation method can contribute to the advancement of perfusion based brain tumor evaluation.

The Role of Dynamic Contrast Enhanced MR Mammography in Differentiation between Benign and Malignant Breast Lesions

  • 한송이;차은숙;정상설;김학희;변재영;이재문
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.135-135
    • /
    • 2002
  • Purpose: To assess diagnostic accuracy of dynamic contrast enhanced MR mammography in differentiating between benign and malignant lesions. Materials and methods: Ninety-three patients with suspicious mammographic, sonographic or palpable findings underwent pre- or postoperative contrast-enhanced MR imaging of breast using three dimensional fast low-angle shot (3D FLASH) sequence (16/4 msec[repetition time / echo time], 20 flip angle, 3mm slice thickness with no slice gap, 256 by 256 in-plane matrix) covering whole breasts. T1 weighted images were obtained before and after bolus administration of gadopentetate dimeglumine (0.15 mmol/kg). Subtraction images and time-signal intensity curves of region of interest were obtained sequentially and correlated with pathologic diagnoses of lesions.

  • PDF

Perfusion MR Imaging in Gliomas: Comparison with Histologic Tumor Grade

  • Sun Joo Lee;Jae Hyoung Kim;Young Mee Kim;Gyung Kyu Lee;Eun Ja Lee;In Sung Park;Jin-Myung Jung;Kyeong Hun Kang;Taemin Shin
    • Korean Journal of Radiology
    • /
    • 제2권1호
    • /
    • pp.1-7
    • /
    • 2001
  • Objective: To determine the usefulness of perfusion MR imaging in assessing the histologic grade of cerebral gliomas. Materials and Methods: In order to determine relative cerebral blood volume (rCBV), 22 patients with pathologically proven gliomas (9 glioblastomas, 9 anaplastic gliomas and 4 low-grade gliomas) underwent dynamic contrast-enhanced T2*-weighted and conventional T1- and T2-weighted imaging. rCBV maps were obtained by fitting a gamma-variate function to the contrast material concentration versus time curve. rCBV ratios between tumor and normal white matter (maximum rCBV of tumor / rCBV of contralateral white matter) were calculated and compared between glioblastomas, anaplastic gliomas and low-grade gliomas. Results: Mean rCBV ratios were 4.90°±1.01 for glioblastomas, 3.97°±0.56 for anaplastic gliomas and 1.75°±1.51 for low-grade gliomas, and were thus significantly different; p < .05 between glioblastomas and anaplastic gliomas, p < .05 between anaplastic gliomas and low-grade gliomas, p < .01 between glioblastomas and low-grade gliomas. The rCBV ratio cutoff value which permitted discrimination between high-grade (glioblastomas and anaplastic gliomas) and low-grade gliomas was 2.60, and the sensitivity and specificity of this value were 100% and 75%, respectively. Conclusion: Perfusion MR imaging is a useful and reliable technique for estimating the histologic grade of gliomas.

  • PDF