• Title/Summary/Keyword: T1강조영상

Search Result 261, Processing Time 0.024 seconds

MR Imaging Findings of Recurred Dermatofibrosarcoma Protuberans of the Scalp: A Case Report (두피에서 재발한 융기성 피부섬유육종의 MR영상: 증례 보고)

  • Cho, Joon;Roh, Hong-Gee;Kim, Mi-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.121-125
    • /
    • 2006
  • A 48-year-old man presented with a dermatofibrosarcoma protuberans (DFSP) of the scalp associated with local recurrence. Axial T1- and T2-weighted images demonstrated a well-circumscribed hypointense and intermediate hyperintense mass in the skin and subcutaneous layer of the scalp, respectively. Contrast-enhanced T1-weighted images showed the strongly enhanced mass invasion to the skin, subcutaneous layer and adjacent galeal layer. Scalp DFSP is very uncommon but is an aggressive tumor, so MR imaging diagnosis of the extent of the lesion to underlying structures, and initial wide local resection is important to prevent recurrence.

  • PDF

Intradural Extramedullary Ependymoma with Hemorrhage: A Case Report (출혈을 동반한 경막내 수외 뇌실막세포종: 증례 보고)

  • Changwon Choi;Sun Joo Lee;Sung Hwa Paeng;Hwa Jin Cho
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.6
    • /
    • pp.1414-1420
    • /
    • 2023
  • In adults, spinal ependymomas are usually found in intramedullary locations. However, intradural extramedullary spinal ependymomas are rare. Additionally, spinal ependymomas usually show iso to hypointensity on T1-weighted images without hemorrhage. Herein, we present a rare case of a 43-year-old female with a pathologically confirmed intradural extramedullary ependymoma that showed hyperintensity on T1-weighted imaging accompanied by hemorrhage.

Pre-operative Evaluation of Consistency in Intra-axial Brain Tumor with Diffusion-weighted Images (DWI) and Conventional MR Images (확산강조영상과 고식적 자기공명영상을 이용한 수술 전 축내 뇌종양의 경도 평가)

  • Oh, Moon-Sik;Ahn, Kook-Jin;Choi, Hyun-Seok;Jung, So-Lyung;Lee, Yoon-Joo;Kim, Bum-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.2
    • /
    • pp.102-109
    • /
    • 2011
  • Purpose : To retrospectively evaluate the usefulness of diffusion-weighted images, ADC maps and conventional MR images for determination of brain tumor consistency. Materials and Methods : Twenty-three patients with brain tumor underwent MR examinations with T1, T2 and diffusion-weighted images. Regions of interest (ROIs) were drawn in the tumors, and the measured signal intensities (SI) were normalized with the contralateral side. We evaluated the correlation between SI ratios from various images and tumor consistency assessed at surgery. In three patients with both cystic and solid components, each component was evaluated independently. Qualitatively observed SIs were also correlated with tumor consistency. Results : Statistical analysis revealed significant correlation between tumor consistency and ADC ratio (r = -0.586, p = 0.002), SI ratios on T2-weighted images (r = -0.497, p = 0.010), and observed SIs on T2-weighted images (r = -0.461, p = 0.018). The relative ratio of ADC value correlated with tumor consistency most strongly. Conclusion : The measured ratio of ADC, SI ratio and observed SI grade on T2-weighted images can provide valuable information about the consistency of brain tumor.

The Age-related Microstructural Changes of the Cortical Gray and White Matter Ratios on T2-, FLAIR and T1- weighted MR Images (T2, FLAIR, T1 강조 MR영상에서 나이에 따른 뇌피질의 회질과 백질의 미세구조 변화)

  • Choi, Sun-Seob;Kim, Whi-Young;Lee, Ki-Nam;Ha, Dong-Ho;Kang, Myong-Jin;Lee, Jin-Hwa;Yoon, Seong-Kuk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.32-40
    • /
    • 2011
  • Purpose : The purpose of this study was to investigate the microstructural changes according to aging on the thickness and signal intensity (SI) of the cortical gray matter (GM) and white matter (WM) on the T2-, fluid-attenuated inversion recovery (FLAIR) and T1-weighted MR images in normal subjects. Materials and Methods : The 10, 20, 30, 40, 50, 60, 70, 80 and 90 year age groups of men and women (each 10 individuals) who underwent routine brain MRI, including the T2-, FLAIR and T1-weighted images, were selected for this study. We measured the thickness and the SI of the cortical GM and WM at the postcentral gyrus, which has an even thickness at the level of centrum semiovale, on the axial scans and we calculated the mean values of the thickness ratio of the gray/white matter (TRGW) and the signal intensity ratio of the gray/white matter (SRGW), and we compared the ratios of each age group. Results : On the T2-weighted images, the TRGWs were 0.81 and 0.79 at the age of 10 and they were 0.73 and 0.71 at the age of 90 in the men and women, respectively. So, the GM thickness was decreased more than the WM thickness was with aging. On the FLAIR images, the TRGWs were 1.09 and 1.00 at the age of 10 and they were 1.11 and 0.95 at the age of 70 in the men and women, respectively. On the T1-weighted images, the TRGWs were 0.66 and 0.80 at the age of 10, and the ratio was changed to 0.90 and 0.78 at the age of 90 in the men and women, respectively. On the T2-weighted image, the SRGWs were 1.53 and 1.43 at the age of 10, and they were 1.23 and 1.27 at the age of 90 in the men and women, respectively. On the FLAIR images, the SRGWs were 1.23 and 1.25 at the age of 10 and they were 1.06 and 1.05 at the age of 90 in the men and women, respectively. On the T1-weighted images, the SRGWs were 0.86 and 0.85 at the age of 10, and they were 0.90 and 0.87 at the age of 90 in the men and women, respectively. Conclusion : We suggest that the age-related microstructural changes of the thickness and the SI of the cortical GM and WM on the T2-, FLAIR and T1-weighted images are unique, and so this knowledge will be helpful to differentiate neurodegenerative disease from normal aging of the brain.

MR Neurography: Current Several Issues for Novice Radiologists (자기공명영상 신경조영술: 경험이 적은 영상의학과 의사가 이해해야 할 몇 가지 쟁점들)

  • Dong-ho Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.81-100
    • /
    • 2020
  • Magnetic resonance neurography (MRN) has been increasingly used in recent years for the assessment of peripheral neuropathies. Fat suppression T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) have typically been used to provide high contrast MRN. Isotropic 3-dimensional (3D) sequences with fast spin echo, post-processing imaging techniques, and fast imaging methods, among others, allow good visualization of peripheral nerves that have a small diameter, complex anatomy, and oblique course within a reasonable scan time. However, there are still several issues when performing high contrast and high resolution MRN including standard sequence; fat saturation techniques; balance between resolution, field of view, and slice thickness; post-processing techniques; 2D vs. 3D image acquisition; different T2 contrasts between proximal and distal nerves; high T2 signal intensity of adjacent veins or joint fluid; geometric distortion; and appropriate p-values on DWI. The proper understanding of these issues will help novice radiologists evaluate peripheral neuropathies using MRN.

Acute Cerebral Infarction in a Rabbit Model: Perfusion and Diffusion MR Imaging (가토의 급성 뇌경색에서 관류 및 확산강조 자기공명영상)

  • Heo Suk-Hee;Yim Nam-Yeol;Jeong Gwang-Woo;Yoon Woong;Kim Yun-Hyeon;Jeong Young-Yeon;Chung Tae-Woong;Kim Jeong;Park Jin-Gyoon;Kang Heoung-Keun;Seo Jeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.116-123
    • /
    • 2003
  • Purpose : The present study was undertaken to evaluate the usefulness of cerebral diffusion (DWI) and perfusion MR imaging (PWI) in rabbit models with hyperacute cerebral ischemic infarction. Materials and Methods : Experimental cerebral infarction were induced by direct injection of mixture of Histoacryl glue, lipiodol, and tungsten powder into the internal cerebral artery of 6 New-Zealand white rabbits, and they underwent conventional T1 and T2 weighted MR imaging, DWI, and PWI within 1 hour after the occlusion of internal cerebral artery. The PWI scan for each rabbit was obtained at the level of lateral ventricle and 1cm cranial to the basal ganglia. By postprocessing using special imaging software, perfusion images including cerebral blood volume (CBV), cerebral blood flow (CBF), and mean transit time (MTT) maps were obtained. The detection of infarcted lesion were evaluated on both perfusion maps and DWI. MTT difference time were measured in the perfusion defect lesion and symmetric contralateral normal cerebral hemisphere. Results : In all rabbits, there was no abnormal signal intensity on T2WI. But on DWI, abnormal high signal intensity, suggesting cerebral infarction, were detected in all rabbits. PWI (rCBV, CBF and MTT map) also showed perfusion defect in all rabbits. In four rabbits, the calculated square of perfusion defect in MTT map is larger than that of CBF map and in two rabbits, the calculated size of perfusion defect in MTT map and CBF map is same. Any rabbits do not show larger perfusion defect on CBF map than MTT map. In comparison between CBF map and DWI, 3 rabbits show larger square of lesion on CBF map than on DWI. The others shows same square of lesion on both technique. The size of lesion shown in 6 MTT map were larger than DWI. In three cases, the size of lesion shown in CBF map is equal to DWI. But these were smaller than MTT map. The calculated square of lesion in CBF map, equal to that of DWI and smaller than MTT map was three. And in one case, the calculated square of perfusion defect in MTT map was largest, and that of DWI was smallest. Conclusion : DWI and PWI may be useful in diagnosing hyperacute cerebral ischemic infarction and in e-valuating the cerebral hemodynamics in the rabbits.

  • PDF

Alternative Input Lower Weight Information Method Error to Reduce Specific Absorption Rate in MRI (자기공명영상 검사 시 환자정보의 체중을 낮게 입력하여 전자파흡수율을 감소시키는 대안의 오류)

  • Choi, Kwan-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.2
    • /
    • pp.472-477
    • /
    • 2020
  • The purpose of this study is to correct the error of lower weight input method as an alternative to reduce the specific absorption rate(SAR) in MRI. In order to prove that the SAR values not change according to the weight entered into the patient information, the 50kg phantom is placed in the coil and the input weight is changed from 10 to 100 in 10kg units to compare the SAR values. As a result, T1-weighted images had a SAR rate of 0.2W/kg and T2-weighted images had an average of 0.4W/kg. In conclusions, the SAR does not change according to the weight input by the technician before the scan, a lower weight when inputting patient information cannot be an alternative to reduce the SAR.

Investigation of Correlations of Double Inversion Recovery and MR Spectroscopy on Breast MR Imaging (유방 자기공명영상에의 이중반전회복기법과 자기공명분광영상법의 상관관계 연구)

  • Ryu, Jung Kyu;Rhee, Sun Jung;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.34-42
    • /
    • 2014
  • Purpose : To evaluate the correlation of lesion-to-normal ratio (LNR) of signal intensity from double inversion recovery MR imaging and total choline-containing compound (tCho) resonance from single voxel MR spectroscopy in breast cancers. Materials and Methods: Between August 2008 and December 2009, 28 patients who were diagnosed as breast cancer and had undergone both double inversion recovery (DIR) MR imaging and MR spectroscopy (MRS) were included in this study. The signal intensities of the lesion (L) and ipsilateral normal breast tissue (N) were measured in region of interest of each breast cancer in DIR and contrast enhance MR image (CE-T1WI) to calculate the LNR value for each technique. MRS was performed using single-voxel MR spectroscopy. The height, width and area of tCho resonance were compared with each LNR of DIR and CE-T1WI. We used Pearson's correlation coefficient(r) for correlation analysis and the significance level was p=0.05. Results: There was no statistically significant correlation between LNR of CE-T1WI and height (r=-0.322, p=0.094), width (r=-0.233, p=0.232) and area (r=-0.309, p=0.109) of MRS tCho. There was no statistically significant correlation between LNR of DIR and height (r=0.067, p=0.735), width (r=-0.287, p=0.139) and area (r=0.012, p=0.953) of MRS tCho, either. The Pearson's correlation coefficient was 0.186 between LNRs of CET1WI and DIR (p=0.344). Conclusion: There was no statistically significant correlation between LNR of DIR and relative amount of tCho resonance of MRS.

MR Imaging Characteristics of Primary T-Cell Lymphoma of the Cauda Equina: A Case Report and Literature Review (말총의 원발성 T세포 림프종에서 MR 영상 소견: 증례 보고와 문헌 고찰)

  • Younguk Kim;Guen Young Lee;Sujin Kim;Kwang-sup Song;Hee Sung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1613-1618
    • /
    • 2021
  • Primary central nervous system lymphoma is a rare form of extranodal non-Hodgkin lymphoma, and primary T-cell lymphoma of the cauda equina is extremely rare. We describe a case involving a 56-year-old female who presented with low back pain and radiating leg pain for 4 months. MRI of the lumbar spine revealed an elongated, multinodular intradural lesion of approximately 10 cm from the L4 body to the S2 body level with iso-signal intensity on T1-weighted imaging, heterogeneous iso- and high-signal intensity on T2-weighted imaging, and a heterogeneous intense enhancement on gadolinium contrast-enhanced T1-weighted imaging. A peripheral T-cell lymphoma of the cauda equina was diagnosed on the basis of immunohistochemical and T-cell receptor gamma gene rearrangement analysis after intradural biopsy of the mass.

Analysis of the Dental Implants MRI Artifacts by Using the ACR Phantom (ACR 팬텀을 이용한 치아 임플란트 자기공명영상 인공물 분석)

  • Shin, Woon-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.629-635
    • /
    • 2016
  • ACR phantom for quality control of magnetic resonance imaging equipment can evaluate magnetic resonance imaging picture quality through various structures within the phantom. In this study, percent Signal Ghosting and Slice position accuracy of imaging could be analyzed by attaching implant and the wire for correction of tooth using ACR phantom in Head coil of 3.0T equipment. In the T1 weighted imaging of the first slice and the eleventh slice of implant, the slice position accuracy appeared to be good in ingress bandwidth 300, and it was good in ingress bandwidth 130 when wire for correction was attached. Percent Signal Ghosting in the seventh slice of SE T1 weighted imaging, implant and wire for correction added all appeared to be good when ingress bandwidth was 230. It is thought that in case of implant dental prosthesis patients in brain exam using magnetic resonance imaging, optimum image can be obtained by changing ingress bandwidth.