• Title/Summary/Keyword: T-type inverter

Search Result 96, Processing Time 0.029 seconds

Feasibility Study of Distributed Auxiliary Resonant Commutation Snubber Linked Three Phase Voltage Source ZVS Inverter with Digital Servo Control Implementation

  • Hiraki, E.;Hattori, H.;Nakaoka, M.;Horiuchi, T.;Sugawara, Y.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.341-345
    • /
    • 1998
  • This paper presents performance and loss analysis of Auxiliary Resonant Commutation Snubber-linked (ARCS) three phase voltage source soft switching inverter which is operated under a condition of Zero Voltage Switching (ZVS). The system performances of this ARCS soft switching inverter which is controlled on optimal type I digital servo scheme are illustrated and evaluated on the basis of experimental results.

  • PDF

DSVPWM Method for Improving the Efficiency of Three-phase Three Level NPC & T-type Inverter (삼상 3레벨 NPC 인버터와 T-type 인버터의 효율개선을 위한 DSVPWMx 적용 및 해석)

  • Shin, Hyunjin;Park, Juyoung;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.113-114
    • /
    • 2014
  • 대용량 분산 발전원이 증가하면서 이러한 대용량 분산 발전을 효율적으로 운전하기 위한 많은 연구가 진행되고 있다. 본 논문에서는 멀티레벨 인버터 토폴로지 중 3L-NPC와 3L-T-type 인버터에 DSVPWMx(DSVPWMP, DSVPWMN, DSVPWMPN0, DSVPWMPN1, DSVPWMPN2, DSVPWMPN3)를 적용하였을 때 두 개의 멀티레벨 인버터에서 발생하는 효율의 차이를 비교하였다. 이를 검증하기 위한 방법으로 Psim Thermal Module을 활용하여 회로를 구성하고 각 PWM방식에서 전압변조비에 따른 효율을 비교 분석하였다.

  • PDF

DSVPWM Method for Improving the Efficiency of Three-phase Three Level T-type Inverter (삼상 3레벨 T-type 인버터의 효율개선을 위한 DSVPWMx 적용 및 해석)

  • Shin, Hyunjin;Park, Juyeong;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.441-442
    • /
    • 2014
  • 대용량 분산 발전에 대한 관심이 많아지면서 분산발전원의 효율을 증가시키기 위한 많은 토폴로지들과 제어방식들이 적용되고 있다. 인버터의 효율을 증가시키기 위한 방법으로는 멀티레벨 인버터 토폴로지를 적용하는 방법과 스위칭 손실을 저감 시키기 위한 PWM방식을 쓰는 방법 등이 있다. 본 논문에서는 멀티레벨 인버터 중 T-type 인버터의 효율을 개선하기 위한 방법으로 DSVPWMx(DSVPWMP, DSVPWMN, DSVPWMPN0, DSVPWMPN1, DSVPWMPN2, DSVPWMPN3)를 적용하였다. 이를 검증하기 위한 방법으로 Psim Thermal Module을 활용하여 회로를 구성하고 각 PWM방식에서 전압변조비에 따른 THD와 효율을 비교 분석하였다.

  • PDF

DSVPWM Method for Efficiency Improving and Neutral Point Voltage Control of Three-phase Three Level NPC and T-type Inverter (삼상 3레벨 NPC 인버터와 T-type 인버터의 효율개선 및 중성점 제어를 위한 DSVPWMx 적용 및 해석)

  • Park, Juyoung;Park, Jonghoon;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.57-58
    • /
    • 2015
  • 대용량 분산 발전원이 증가하면서 이러한 대용량 분산 발전을 효율적으로 운전하기 위한 많은 연구가 진행되고 있다. 본 논문에서는 멀티레벨 인버터 토폴로지 중 NPC와 T-type 인버터의 중성점 전압제어와, DSVPWMx(Discontinuous Space Vector Pulse Width Modulation) 방식을 적용하여 두 개의 멀티레벨 인버터에서 발생하는 효율과 제어방식의 차이를 시뮬레이션 하였다.

  • PDF

Characteristic Analysis of Series Resonant High Frequency Inverter with Separated Capacitor (커패시터 분할형을 갖는 직렬공진 고주파 인버터의 특성해석)

  • Lee, Bong-Seob;Oh, Seung-Hoon;Jung, Do-Young;Lee, Sang-Ho;Ko, Seo-Yeong;Oh, Hong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1224-1226
    • /
    • 2000
  • In this paper, load paralleled type FB series resonant inverter of a new novel type is proposed. In the output control method, phase-shift driving signal control method with CVCF introduces. Also by driving signal patterns, the operation principle of the proposed circuit in detail is described and its characteristics are compared on separated ratio(n). According to each the mode in order to the analysis and characteristic evaluation of the circuit state equations are derived and presented using normalized parameter. To verify the theoretical analysis result, experimental results are provided.

  • PDF

A Band Pass Filter with Directly Coupled Feeding Structure Using K-Inverter (K-인버터를 이용한 직접 결합 급전 구조를 갖는 대역 통과 필터)

  • Kim, In-Seon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.6 s.121
    • /
    • pp.639-647
    • /
    • 2007
  • This paper proposed the novel method that can realize the parallel coupled line(PCL) band-pass filter with directly coupled feeding structure by means of transforming the first and last PCL sections of the conventional PCL band-pass filter into K-inverters, then substituting T-type equivalence for K-inverter. The proposed method supplies simple design formulae and can considerably reduce time and efforts needed to optimize filter performance when compared to reported methods using external Q or equivalent parameters. On the basis of the proposed method, the band-pass filter using directly coupled feeding structure and having 18% fractional bandwidth was designed and fabricated. The validity of proposed method was proven by the measured result.

Development of Uninterruptible Power Supply with Voltage Sag Restorer Function (순시전압강하 보상 기능을 가지는 무정전전원공급장치의 개발)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.95-101
    • /
    • 2014
  • In this paper, UPS, with a built-in instantaneous sag drop compensation features, was developed to improve performance. The improved UPS, using instantaneous moving average method, compensates by quickly measuring the voltage and series inverter of half-bridge type, using line-interactive method that links with the voltage of the battery and power source, was developed. In addition, by developing a parallel inverter that uses a high-efficiency PWM switching method, overall UPS system was enhanced. To verify the performance of the proposed algorithm, single-phase 5[kVA] UPS systems were designed and the experimental system was constructed. The low-cost type of Cortex-M3 module CPU STM32F103R8T6 (32[bit]) is attached and the switching time of mode transfer was set within 4 [ms]. THD of the linear load operates in less than 3[%], and the stability of the output voltage operates in approximately ${\pm}2[%]$ range. The superior performance of the operations was confirmed with the system set as above.

A Resonant Circuit Design of the Inverter for Induction Heating by Analysis of the Coupling Coefficient (결합계수 해석에 의한 유도가열용 인버터의 공진회로 설계법)

  • 이광직;김주홍
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.6
    • /
    • pp.90-95
    • /
    • 1997
  • In designing a resonant circuit of the inverter which puts induction heating with high frequency to the load, an inductance L of the circuit, the coupling coefficient of a transformer transfering the output power to load, and the coupling coefficient of load circuit heating with coil affect to the output power of a resonant circuit, the circuit Q and the frequency. Those characteristics of the circuit are analyzed through Thevenan's equivalent circuit of the coupling coefficient type which is derived from the T-type equivalent circuit of a transformer. On this equivalent circuit, the impedance of a transformer referred to its primary side is not only proportional the square of turn ratio, nZ, but also the square of coupling coefficient, K2 This paper proposed a more accurate fundamental method to design a resonant circuit of the inverter by using the Thevenan's equivalent circuit.

  • PDF

A Voltage Inverter Switch With a New Clocking Scheme and its Application to Switched Capacitor Filter Design (새로운 Clocking 방식에 의한 Voltage Inverter Switch 및 Switched Capacitor Filter 설계에의 응용)

  • 이방원;박송배
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.18 no.4
    • /
    • pp.1-11
    • /
    • 1981
  • This paper proposes a method of generalizing the clocking scheme in the Switched Capacitor Filter(SCF) design using Voltage Inverter Switches (VIS's). Parallel RC and RL elements, and parallel LC resonators can be implemented by the proposed clocking schemes Applying these new elements and the generalized clocking schemes to the SCF design, the total number of required operational amplifiers and capacitors can be reduced. Experimental results of a band- stop filter and a low-pass filter using a new type grounded VIS show good agreements with t he theoretical characteristics.

  • PDF

Multilevel Inverter Development to Utilize Renewable Energy in Urban Railway Station (도시철도 역사 신재생에너지 활용을 위한 멀티레벨 인버터 개발)

  • Shin, Seungkwon;Kim, Hyungchul;Jung, Hosung;Park, Jong Young;Hyun, Byungsoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.324-330
    • /
    • 2015
  • Energy Saving Methods in existing railway vehicle are considered by active approach such as regenerative energy storage and utilization, eco driving, etc. On the other hands, energy saving measures in railway station are operated by passive method such as reduction of operating time in ventilation system, cooing system and power equipment. To reduce energy and for independence in railway system, it requires an active energy saving measures. It needs to its own power source besides the power source of electric supply company such as renewable energy and regenerative energy and take the advantage of power storage system and stored power are used in optimum time. This paper deal with 3-level NPC inverter and T-type NPC inverter that used in various multi-level topology applicable to the railway system.