• 제목/요약/키워드: T-type H-bridge

검색결과 19건 처리시간 0.023초

A Novel Modulation Scheme and a DC-Link Voltage Balancing Control Strategy for T-Type H-Bridge Cascaded Multilevel Converters

  • Wang, Yue;Hu, Yaowei;Chen, Guozhu
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2099-2108
    • /
    • 2016
  • The cascaded multilevel converter is widely adopted to medium/high voltage and high power electronic applications due to the small harmonic components of the output voltage and the facilitation of modularity. In this paper, the operation principle of a T-type H-bridge topology is investigated in detail, and a carrier phase shifted pulse width modulation (CPS-PWM) based control method is proposed for this topology. Taking a virtual five-level waveform achieved by a unipolar double frequency CPS-PWM as the output object, PWM signals of the T-type H-bridge can be obtained by reverse derivation according to its switching modes. In addition, a control method for the T-type H-bridge based cascaded multilevel converter is introduced. Then a single-phase T-type H-bridge cascaded multilevel static var generator (SVG) prototype is built, and a repetitive controller based compound current control strategy is designed with the DC-link voltage balancing control scheme analyzed. Finally, simulation and experimental results validate the correctness and feasibility of the proposed modulation method and control strategy for T-type H-bridge based cascaded multilevel converters.

Damage detection in truss bridges using vibration based multi-criteria approach

  • Shih, H.W.;Thambiratnam, D.P.;Chan, T.H.T.
    • Structural Engineering and Mechanics
    • /
    • 제39권2호
    • /
    • pp.187-206
    • /
    • 2011
  • This paper uses dynamic computer simulation techniques to develop and apply a multi-criteria procedure using non-destructive vibration-based parameters for damage assessment in truss bridges. In addition to changes in natural frequencies, this procedure incorporates two parameters, namely the modal flexibility and the modal strain energy. Using the numerically simulated modal data obtained through finite element analysis of the healthy and damaged bridge models, algorithms based on modal flexibility and modal strain energy changes before and after damage are obtained and used as the indices for the assessment of structural health state. The application of the two proposed parameters to truss-type structures is limited in the literature. The proposed multi-criteria based damage assessment procedure is therefore developed and applied to truss bridges. The application of the approach is demonstrated through numerical simulation studies of a single-span simply supported truss bridge with eight damage scenarios corresponding to different types of deck and truss damage. Results show that the proposed multi-criteria method is effective in damage assessment in this type of bridge superstructure.

Damage detection in truss bridges using transmissibility and machine learning algorithm: Application to Nam O bridge

  • Nguyen, Duong Huong;Tran-Ngoc, H.;Bui-Tien, T.;De Roeck, Guido;Wahab, Magd Abdel
    • Smart Structures and Systems
    • /
    • 제26권1호
    • /
    • pp.35-47
    • /
    • 2020
  • This paper proposes the use of transmissibility functions combined with a machine learning algorithm, Artificial Neural Networks (ANNs), to assess damage in a truss bridge. A new approach method, which makes use of the input parameters calculated from the transmissibility function, is proposed. The network not only can predict the existence of damage, but also can classify the damage types and identity the location of the damage. Sensors are installed in the truss joints in order to measure the bridge vibration responses under train and ambient excitations. A finite element (FE) model is constructed for the bridge and updated using FE software and experimental data. Both single damage and multiple damage cases are simulated in the bridge model with different scenarios. In each scenario, the vibration responses at the considered nodes are recorded and then used to calculate the transmissibility functions. The transmissibility damage indicators are calculated and stored as ANNs inputs. The outputs of the ANNs are the damage type, location and severity. Two machine learning algorithms are used; one for classifying the type and location of damage, whereas the other for finding the severity of damage. The measurements of the Nam O bridge, a truss railway bridge in Vietnam, is used to illustrate the method. The proposed method not only can distinguish the damage type, but also it can accurately identify damage level.

압전 변압기를 이용한 35W(T5)급 형광등 안정기 구동 시스템 특성에 관한 연구 (A Study on Drive System Characteristics of the Ballast for 35W(T5) Fluorescent Lamp using Piezoelectric Transformer)

  • 황락훈;장진혁;나승권;김영수;안익수;조문택;송호빈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1031-1033
    • /
    • 2006
  • In this study, in order to solve these problems, a new type of electronic ballast, which is composed of rectifier, active power factor corrector, series resonant half bridge inverter and piezoelectric transformer, was proposed for driving T5 fluorescent lamp. Driving of piezoelectric transformer was carried out with input region for the ring electrode and output region for the dot electrode. A 35W (T5) fluorescent lamp was successfully driven by the fabricated ballast with piezoelectric transformer.

  • PDF

회전자 슬롯에 U자형 Iron bridge와 Slit이 있는 3상 농형 유도전동기의 특성비교 (Comparision of the characteristics of 3-phase squirrel cage induction motor with slit and U-iron bridge type rotor slot)

  • 김병택;권병일;박승찬;김근웅;윤종학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.41-43
    • /
    • 1997
  • This paper represents the comparison of harmonic loss characteristics of the inverter-driven 3-phase squirrel cage induction motor with slit and U-iron bridge slots of rotor. Two-dimensional time-stepped finite element method is used for electromagenetic field analysis. And spectrums of bar current, phase current, and torque are compared in each case.

  • PDF

A Single-Phase Hybrid Multi-Level Converter with Less Number of Components

  • Kim, Ki-Mok;Moon, Gun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.105-107
    • /
    • 2018
  • This paper presents a new hybrid multilevel converter topology, which consists of a combination of the series connected switched capacitor units with boost ability, and an H-bridge with T-type bidirectional switches. The proposed converter boosts the input voltage without any bulky inductors, and has the small number of components, which can make the size and cost of a power converter greatly reduced. The output filter size and harmonics are also reduced by the high quality multilevel output. In addition, there is no need for complicated methods to balance the capacitor voltage. Simulation and experimental results with a nine-level converter system are presented to validate the proposed topology and modulation method.

  • PDF

Protective Ability Index of Rust Layer Formed on Weathering Steel Bridge

  • Hara, S.;Kamimura, T.;Miyuki, H.;Yamashita, M.;Uchida, H.
    • Corrosion Science and Technology
    • /
    • 제6권3호
    • /
    • pp.128-132
    • /
    • 2007
  • For a quantitative inspection on the performance of weathering steel bridges, we have investigated the relationship between the corrosion rate and the composition of the rust layers formed on weathering steel bridges located in various environments in Japan and applied a protective ability index (PAI) to the bridges. The corrosion rates were clearly classified by the PAI, ${\alpha}/{\gamma}*$ and sub index of $({\beta}+s)/{\gamma}*$, where $\alpha$, \gamma*, $\beta$ and s are the mass ratio of crystalline $\alpha-FeOOH$, the total of $\gamma$-FeOOH+ $\beta$-FeOOH + the spinel-type iron oxide (mainly $Fe_3O_4$), $\beta-FeOOH$ and spinel-type iron oxide, analyzed by powder X-ray diffraction, respectively. In the case of ${\alpha}/{\gamma}$*>1, the rust layer works protective enough to reduce the corrosion rate less than 0.01 mm/y. The sub index $({\beta}+s)/{\gamma}*$<0.5 or >0.5 classifies the corrosion rate of the non-protective rust layers, therefore the former state of the rust layer terms inactive and the latter terms active. The quantitative inspection of a weathering steel bridge requires a performance-inspection (PI) and periodical deteriorationinspections (DI). The PI can be completed by checking of the PAI, ${\alpha}/{\gamma}*$. The DI on the weathering steel bridges where deicing salt is sprinkled can be performed by checking the PAI, $({\beta}+s)/{\gamma}*$.

저온 주사 레이저 현미경(LTSLM)을 이용한 YBCO 초전도 선재의 불균질성 연구 (A study on inhomogeneity of YBCO Coated Conductors using Low-temperature Scanning Laser Microscopy (LTSLM))

  • 박상국;김종만;이상봉;김상훈;김가영;이형철
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.72-77
    • /
    • 2009
  • Low temperature scanning laser microscopy (LTSLM) can be used for a two-dimensional display of bolometric response arising from the localized excitation of a sample by the focused laser beam. In this study, the distribution of critical temperature ($T_c$) and critical current density ($J_c$) in YBCO coated conductor were analyzed using LTSLM. For improving the temperature stability, we have modified the system into a double-shielding type. Through the modification, the temperature stability was successfully improved from ${\pm}10mK\;to\;{\pm}2mK$. The superconducting properties of YBCO coated conductors were measured for the sample of a narrow bridge type using wet etching process. The spatial non-uniformity of the ac voltage response, ${\delta}V(x)$, which is proportional to ${\partial}\rho(x,J_B)/{\partial}T$ in the transition temperature region could be observed and displayed in a two-dimensional image.

  • PDF

Series Capacitor Compensated Resonant High Frequency Inverter with ZCS-Pulse Density Modulation fey Induction Heating Fixing Roller in Copy Machine

  • Ahmed T.;Shirai H.;Gamage L.;Soshin K.;Nakaoka M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.499-502
    • /
    • 2003
  • This paper presents the voltage source type half bridge lossless auxiliary inductor snubber assisted series capacitor compensated resonant high frequency inverter for induction heated fixing roller in copy machines. This high-frequency inverter treated here can completely achieve zero current soft switching (ZCS) commutation for wide power regulation range under its constant frequency pulse density modulation (PDM) scheme. Its transient and steady-state operating principle is originally presented fur a constant frequency PDM control strategy under a ZCS operation commutation, together with its output effective power regulation characteristics-based on the PDM strategy. The experimental operating performances of this ZCS-PDM high frequency inverter using IGBTs are illustrated as compared with computer simulation ones. Its power losses and actual efficiency are evaluated and discussed on the basis of simulation and experimental results.

  • PDF

Onechip Microcontroller에 의한 압전 변압기를 이용한 T5 28W급 형광등 전자식안정기에 관한 연구 (A study on 7528W Class Fluorescent Lamp Ballast using a Piezoelectric Transformer by means of Onechip Microcontroller)

  • 황락훈;신양호;조상로;장은성;조문택;안익수;김주래
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.228-232
    • /
    • 2002
  • In this paper, In order to solve the problem is proposed using a new type of electronic ballast that the traditional magnetic ballasts operated at 50-60Hz have been suffered from noticeable flicker, high loss, large crest factor and heavy weight which is composed of rectifier, active power corrector, series resonant half bridge inverter, micro-controller and piezoelectric transformer for driving for driving T5 fluorescent lamp were manufactured. The proposed electronic ballast operated at high frequency (about 75kHz) shows a input power factor of more than 0.995, total harmonic distortion of less than $12\%$ and lamp current crest factor of less than 1.5, respectively. Output power and efficiency showed 28w and $85\%$, respectively. Accordingly, it is considered that the ballast using piezoelectric transformer can replace the typical electronic ballast.

  • PDF