• Title/Summary/Keyword: T-test analysis

Search Result 10,833, Processing Time 0.035 seconds

Evaluation of the Image Blurring in the Fast Spin Echo Technique ccording to Variation of the ETL (고속스핀에코기법을 이용한 MRI검사에서 ETL 변화에 따른 영상 blurring의 평가)

  • Kwon, Soon-Yong;Lim, Woo-Taek;Kang, Chung-Hawn;Kim, Kyeong-Soo;Kim, Soon-Bae;Kim, Hyun-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.2
    • /
    • pp.55-61
    • /
    • 2013
  • The purpose of this study is to evaluate image blurring according to variation of the ETL and propose the clinically appropriate ETL range. SIEMENS MAGNETOM Skyra 3.0T and 20 channel head coil were used for the study. MRI phantom was kept the lines horizontally to three direction(X,Y,Z) of the coil and T1, T2 weighted images that used the fast spin echo technique acquired. The ETL with increase of 10 was applied from 10 to 80. In addition, the ETL with increase of 1 was applied in the interval statistically significant differences occurred. And T1, T2 weighted images that used the conventional spin echo technique acquired to compare image blurring of the images that used the fast spin echo technique. The slope of lattice in the images was measured using Image J 1.47v program to evaluate image blurring. And image blurring was determined by the degree of the slope. The statistical significance of both techniques was evaluated by the Kruskal-Wallis test of the SPSS 17.0v. And the correlation of the ETL and image blurring was evaluated quantitatively by regression analysis. The slope of the T1, T2 weighted images that used fast spin echo technique decreased as contrasted with conventional spin echo technique. In the result of the Kruskal-Wallis test, the T1, T2 weighted images that used fast spin echo technique made a significant difference with conventional spin echo technique. Particularly, in the Tomhane' T2 test, the T1, T2 weighted images made a significant difference from ETL 22 and 31 respectively. In the result of the regression analysis, the R-squared of the T1, T2 weighted images are 0.762 and 0.793. It is difficult to apply the long ETL in the T1 weighted image caused by the short TR and multi-slices study. Therefore, clinical impact according to variation of the ETL is very slight in the T1 weighted images. But the application of the proper ETL is demanded in T2 weighted images using the fast spin echo technique in order to prevent image blurring.

  • PDF

Analysis of Stability and Dynamic Behaviour of Cracked Cantilever T-beams Subjected to Axial Force (축압축력을 받는 T형상 크랙 보의 안정성 및 동특성 해석)

  • Son, In-Soo;Jo, Jeng-Rae;Yoon, Han-Ik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.5
    • /
    • pp.453-459
    • /
    • 2010
  • In this paper, the purpose is to investigate the stability of cracked cantilever T-beams subjected to axial force. In addition, an analysis of the natural frequency of a cracked beams as crack position, crack depth and tip mass is investigated. Based on the Euler-Bernoulli beam theory, the equation of motion is derived by the energy expressions using extended Hamilton's Principle. The crack is assumed to be in the first mode of fracture and to be always opened during the vibrations. The results of this study will contribute to the safety test and stability estimation of structures of a cracked T-beams subjected to axial force.

Reliability Analysis of Door Control Unit of Korean Tilting Tran (곡선부 주행성능 향상을 가진 틸팅 열차의 DCU(Door Contol Unit)의 신뢰성 분석)

  • Song, Yong-Soo;Han, Sung-Ho;Kim, Nam-Po
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.941-946
    • /
    • 2007
  • In this paper, as the step to assess and enhance the reliability of Korean Tilting Train eXpress (T.T.X), Door system is selected and reliability analysis is carried out. The door system is classified into subsystems and functional block diagrams and reliability block diagrams are drawn.Expessions for evaluating the reliability are derived and Mean Kilometer between Service Failure is calculated using the trial track test results. The calculation result show reliability growth of proposed system. This paper developed RAMS to make a door system of T.T.X. (Tilting Train eXpress) with maximum operation speed of 180 km/h.

  • PDF

Ultimate Strength of branch-rotated T-joints in Cold-formed Square Hollow Sections - Chord flange failure mode - (지관이 회전된 냉간성형 각형강관 T형 접합부의 최대내력(I) - 주관 플랜지 파괴모드 -)

  • Bae, Kyu Woong;Park, Keum Sung;Kang, Chang Hoon;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.5 s.60
    • /
    • pp.657-664
    • /
    • 2002
  • This paper described the ultimate strength and deformation limit of the new uniplanar T-joints in cold-formed square hollow sections. In the configuration of the new T-joint, only a branch member is orientated to a chord member at 45 degrees in the plane of the truss. This study focused on the branch-rotated T-joints that were governed by chord flange failure in previous studies. Test results of the T-joint in cold-formed square hollow sections revealed a deformation limit of 3%B for $16.7{\leq}2{\gamma}(=B/T){\leq}33.3$ and $0.27{\leq}{\beta}(=b1/B){\leq}0.6$. The existing strength formulae for traditional T-joint were determined and a new yield-line model for the branch-rotated T-joint proposed. Finally, the strength formula on the yield-line analysis was compared with test results and the application range of the proposed formula recommended.

Bioequivalence Test of Biphenyl Dimethyl Dicarboxylate Products (비페닐디메칠디카르복실레이트 제제의 생물학적 동등성 시험)

  • Han, Sang-Soo;Ham, Seong-Ho;Sohn, Dong-Hwan;Kim, Jae-Baek
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.2
    • /
    • pp.67-72
    • /
    • 1994
  • Bioequivalence (BE) test of biphenyl dimethyl dicarboxylate (DDB) tablets was performed. Normal healthy male volunteers (n = 20) were randomly divided into 2 groups, and reference $(Nissel{\circledR})$ and test $(Livital{\circledR})$ tablets of DDB $(25mg{\times}8\;Tab.\;= \;200\;mg)$ were given orally by balanced two-period cross-over design. The serum concentration was determined by high performance liquid chromatography. The pharmacokinetic parameters, AUC, $C_{max}$, and $T_{max}$ obtained after drug administration were statistically analyzed. Statistical evaluation of the data involved an analysis of variance (ANOVA) for cross-over design. The results were within 20% differences of mean value in AUC, $C_{max}$, and $T_{max}$ between reference and test tablets. The results of ANOVA showed no significant differences for "between group or subject" and "period". The test tablet was bioequivalent with the reference tablet in the AUC, $C_{max}$, and $T_{max}$.

  • PDF

A method of AAL(SSCOP) protocol conformance testing and its result analysis in ATM network (ATM망에서 프로토콜(SSCOP) 적합성 시험 방법 및 결과 분석 방법)

  • 장동원
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.10
    • /
    • pp.2348-2356
    • /
    • 1997
  • This paper describes a method of AAL(SSCOP) protocol conformance testing and its result analysis in ATM network. Terminal equipment(TE) that implements protocols for connecting ATM network shall be verified if appropriately implement by conformance testing. The protocol specifications and the testing methodology are recommended or standardized by international standardization organization(ITU-T, ISO, etc.). The ATM AAL (SSCOP) protocol which selected for describing conformance test procedure is standardized in ITU-T Q.2110 and ATM Forum UNI 3.1 which are same in contents. Also Testing standard like ATS for SSCOP is specified in ATM Forum 95-1459R2. Construction of conformance testing environment is necessary to coordinate in relations with standards, then testing must beexecuted at that environment and the results from the test system analyzed. For this, it is necessary to select any test case from standard for testing and to make ETS. The ETS is proted on the test system and conformance testing will execute on that system. Finally the result from the test system is to analyze. This conformance testing procedure is applicable to the same other test cases in SSCOP and protocols in any communcation networks.

  • PDF

Evaluating Distress Prediction Models for Food Service Franchise Industry (외식프랜차이즈기업 부실예측모형 예측력 평가)

  • KIM, Si-Joong
    • Journal of Distribution Science
    • /
    • v.17 no.11
    • /
    • pp.73-79
    • /
    • 2019
  • Purpose: The purpose of this study was evaluated to compare the predictive power of distress prediction models by using discriminant analysis method and logit analysis method for food service franchise industry in Korea. Research design, data and methodology: Forty-six food service franchise industry with high sales volume in the 2017 were selected as the sample food service franchise industry for analysis. The fourteen financial ratios for analysis were calculated from the data in the 2017 statement of financial position and income statement of forty-six food service franchise industry in Korea. The fourteen financial ratios were used as sample data and analyzed by t-test. As a result seven statistically significant independent variables were chosen. The analysis method of the distress prediction model was performed by logit analysis and multiple discriminant analysis. Results: The difference between the average value of fourteen financial ratios of forty-six food service franchise industry was tested through t-test in order to extract variables that are classified as top-leveled and failure food service franchise industry among the financial ratios. As a result of the univariate test appears that the variables which differentiate the top-leveled food service franchise industry to failure food service industry are income to stockholders' equity, operating income to sales, current ratio, net income to assets, cash flows from operating activities, growth rate of operating income, and total assets turnover. The statistical significances of the seven financial ratio independent variables were also confirmed by logit analysis and discriminant analysis. Conclusions: The analysis results of the prediction accuracy of each distress prediction model in this study showed that the forecast accuracy of the prediction model by the discriminant analysis method was 84.8% and 89.1% by the logit analysis method, indicating that the logit analysis method has higher distress predictability than the discriminant analysis method. Comparing the previous distress prediction capability, which ranges from 75% to 85% by discriminant analysis and logit analysis, this study's prediction capacity, which is 84.8% in the discriminant analysis, and 89.1% in logit analysis, is found to belong to the range of previous study's prediction capacity range and is considered high number.

The Effect of High-Fidelity Simulation Practice Related with Classical Education of Medical Surgical Nursing (성인간호학 이론수업과 연계한 High-Fidelity 시뮬레이션 교육의 효과)

  • Chyn, Yeol-eo;Kim, Kyoung-Mi;Hwang, Hye-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8176-8186
    • /
    • 2015
  • This research was conducted for the purpose of developing a high-fidelity simulation education program, applying it to clinical field and analyzing this program's effect on nursing college students in order to solve problems being caused from the gap between the adult nursing theoretical class and practical education. As the analysis method, this study developed a scenario including an algorithm for caring hyperkalemia patients, the evaluation check list, and debriefing according to the adult nursing theoretical class's learning goal and measured the high-fidelity simulation program's effect in using the non-equivalent control group pre-test and post-test design. As the results from the analysis, there secured the simulation education program's general properties and dependent variable's homogeneity in the experimental group and the control group. The nursing simulation practice program for hyperkalemia patients showed slight effect on the experimental group compared to the control group in fields such as nursing practice ability, problem solving ability, critical thinking skills, self-confidence of nursing, and knowledge. (t=-83.313, p<.001, t=-3.169, p=.003, t=-2.473, p=.017, t=-4.036, p<.001, t=-5.044, p<.001). High-Fidelity simulation programs in conjunction with an adult nursing theory classes of nursing students nursing practice ability, problem solving ability, critical thinking skills, self-confidence of nursing, and knowledge. This simulation program may be an effective educational method for nursing practice and also support improved quality of nursing education.

MRI Findings Suggestive of Metastatic Axillary Lymph Nodes in Patients with Invasive Breast Cancer (유방암 환자에서 액와부 림프절 전이를 시사하는 자기공명영상 소견)

  • Ka Eun Kim;Shin Young Kim;Eun Young Ko
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.620-631
    • /
    • 2022
  • Purpose This study aimed to investigate the diagnostic performance of features suggestive of nodal metastasis on preoperative MRI in patients with invasive breast cancer. Materials and Methods We retrospectively reviewed the preoperative breast MRI of 192 consecutive patients with surgically proven invasive breast cancer. We analyzed MRI findings of axillary lymph nodes with regard to the size, long/short ratio, cortical thickness, shape and margin of the cortex, loss of hilum, asymmetry, signal intensity (SI) on T2-weighted images (T2WI), degree of enhancement in the early phase, and enhancement kinetics. Receiver operating characteristic (ROC) analysis, chi-square test, t test, and McNemar's test were used for statistical analysis. Results Increased shorter diameter, uneven cortical shape, increased cortical thickness, loss of hilum, asymmetry, irregular cortical margin, and low SI on T2WI were significantly suggestive of metastasis. ROC analysis revealed the cutoff value for the shorter diameter and cortical thickness as 8.05 mm and 2.75 mm, respectively. Increased cortical thickness (> 2.75 mm) and uneven cortical shape showed significantly higher sensitivity than other findings in McNemar's test. Irregular cortical margins showed the highest specificity (100%). Conclusion Cortical thickness > 2.75 mm and uneven cortical shape are more sensitive parameters than other findings, and an irregular cortical margin is the most specific parameter for predicting axillary metastasis in patients with invasive breast cancer.

Factors Affecting Family Caregivers' Burden and Depression in Home-based Long-Term Care Service under the Long-Term Care Insurance System

  • Lee, Hung Sa;Kim, Chunmi
    • Research in Community and Public Health Nursing
    • /
    • v.29 no.4
    • /
    • pp.530-538
    • /
    • 2018
  • Purpose: This study tried to identify changes in family burden after the introduction of the long-term care insurance and to examine the factors influencing subjective and objective caring burden and depression of family caregivers of elders receiving home-based long-term care. Methods: Data were collected from 203 family caregivers of elders from August 1 to 31, 2015 using questionnaires. They were analyzed in descriptive statistics, t test, ANOVA test, and multiple regression analysis. Results: The mean score of depression was 7.24, which suggested mild depression level. The subjective family burden was 2.71 and the objective burden 3.04. The factors affecting depression included subjective burden (t=5.08, p<.001), objective burden (t=2.80, p=.006), time of elderly care per day (t=-3.61, p< .001), caregiving duration (t=3.33, p=.001), age (t=3.13, p=.002), family relationship (t=2.48, p=.014), and economic status (t=1.99, p=.047). Conclusion: The family burden was most important influencing factor on caregiver's depression. Therefore, services and supports to alleviate caregivers' burden in the home-based care should be added to long-term care.