• Title/Summary/Keyword: T-test analysis

Search Result 10,833, Processing Time 0.055 seconds

The Relationship Between The Job Satisfaction and The Turnover Intention of 119 Emergency Medical Technicians (119 구급대원의 직무만족도와 이직의도와의 관계)

  • Bae, Ki-Sook
    • The Korean Journal of Emergency Medical Services
    • /
    • v.14 no.1
    • /
    • pp.65-80
    • /
    • 2010
  • Objective : The objective of this study was to survey the job satisfaction and turnover intention of 119 emergency medical technicians who are fire fighters and, at the same time, provide emergency patients with first aid, to examine the correlation between their job satisfaction and turnover intention, and to provide basic materials for the human resource management of 119 emergency medical technicians. Method : The survey was conducted with 152 119 emergency medical technicians working at fire stations in an area of Gyeonggi-do during the period from July 15 to September 14, 2009. Job satisfaction was measured with a tool developed by Kim Sun-sim and Kwon Hye-ran (2002) based on the Index of Work Satisfaction, and turnover intention with the tool developed by Becker (2002) and translated and used by Cho Yeong-sook (2002). The questionnaire was composed of 11 questions on general characteristics, 35 on job satisfaction, and 4 on turnover intention, so a total of 50 questions. The reliability of the questionnaire was Cronbach's ${\alpha}=0.922$ for job satisfaction and Cronbach's ${\alpha}=0.854$ for turnover intention. Using SPSS 14.0, we obtained frequencies, percentages, means, and standard deviations, and performed independent two-sample t-test, one-way ANOVA, and Pearson correlation analysis, and Cronbach's ${\alpha}$. Results : 1) The mean score of the 119 emergency medical technicians' job satisfaction was 2.71, and that of their turnover intention was 2.64. By area of job satisfaction, the mean score was 3.44 for the area of job itself, 2.92 for the interaction area, 2.67 for the organizational demand area, 2.64 for the autonomy area, 2.14 for the wage area, and 1.91 for the working condition area, showing that emergency medical technicians were generally satisfied with their job itself but not with their working condition. 2) As to difference according to the 119 emergency medical technicians' general characteristics, statistically significant difference was observed in job satisfaction according to license type (F = 4.729, p < .010), and in turnover intention according to position (F = 3.768, p < .025). 3) The 119 emergency medical technicians' job satisfaction and turnover intention was in a negative correlation with each other (r = -.44, p < .000) in general, and by the sub-areas of job satisfaction, the correlation with turnover intention was high in order of the autonomy area (r = -.42, p = .000), interaction area (r = -.42, p = .000), job itself (r = -.35, p < .000), organizational demand area (r = -.30, p = .000), wage area (r = -.23, p = .000), and working condition area (r = -.21, p = .008). Conclusion : The 119 emergency medical technicians' job satisfaction showed a negative correlation with their turnover intention. This suggests that turnover intention can be reduced by improving job satisfaction. Furthermore, 119 emergency medical technicians' job satisfaction was high with the job itself, showing their high pride in their job, but was low with working condition and wage. Thus, it is necessary to enhance their job satisfaction by improving the 24-hour work system through supplementing manpower, compensating for overtime works, adjusting work hours per week, etc. These results are expected to be useful in making human resource management plans to lower turnover intention by enhancing 119 emergency medical technicians' job satisfaction.

  • PDF

Bioequivalence of Etodin Capsule to Kuhnillodin Capsule (Etodolac 200 mg) (건일로딘 캡슐(에토돌락 200mg)에 대한 에토딘 캡슐의 생물학적동등성)

  • Lee, Myung-Jae;Kang, Jong-Min;Choi, Sang-Jun;Lee, Jin-Sung;Tak, Sung-Kwon;Seo, Ji-Hyung;Rew, Jae-Hwan;Yim, Sung-Vin;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.6
    • /
    • pp.421-427
    • /
    • 2008
  • The purpose of the present study was to evaluate the bioequivalence of two etodolac capsules, Kuhnillodin capsule (Kuhnil. Co., Ltd., Seoul, Korea) as reference drug and Etodin capsule (Myungmun Pharm. Co., Ltd., Seoul, Korea) as test drug, according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty-three healthy male Korean volunteers received one capsule at the dose of 200 mg etodolac in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of etodolac were monitored by a high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) for over a period of 24 hr after the administration. $AUC_{0-24\;hr}$ was calculated by the linear trapezoidal rule method. $C_{max}$ and $T_{max}$ were compiled from the plasma concentration-time data. Analysis of variance (ANOVA) was carried out using logarithmically transformed $AUC_{0-24\;hr}$ and $C_{max}$. The 90% confidence intervals of the $AUC_{0-24\;hr}$ ratio and the $C_{max}$ ratio for Etodin/Kuhnillodin were $\log\;0.97{\sim}\log\;1.08$ and $\log\;0.89{\sim}\log\;1.19$, respectively. These values were within the acceptable bioequivalence intervals of $\log\;0.80{\sim}\log\;1.25$. Thus, our study demonstrated that Etodin was bioeqiovalent to Kuhnillodin preparation when the rate and extent of absorption between two preparations were compared.

Comparison of peripheral vascular compliance between normal and diabetic groups using the second derivative of photoplethysmogram (PPG 2차 미분을 이용한 정상인과 당뇨병 환자의 말초혈관 탄성도 비교)

  • Kim, Sung-Woo;Lee, Ju-Hyung;Nam, Ki-Chang;Kim, Su-Chan;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.15-20
    • /
    • 2007
  • Recently the prevalence rate of diabetes in Korea has been increasing rapidly due to high growth of economy and changes in dietary lifestyle. Vascular complication is one of diabetic complications which have frequently occurred by obesity, hyperglycemia and impaired glucose metabolism. Photoplethysmogram(PPG) measured from finger and toe is very useful for evaluation of vascular aging and sclerosis level since the PPG signal represents characteristics of peripheral vascular Several researchers have reported that second derivative of the finger PPG waveform was useful to evaluate vascular compliance and developed various analysis methods for vascular compliance. However, peripheral vascular compliance study for diabetic patient was never evaluated by using second derivative of PPG. Therefore, we aimed to objectively compare and to assess normal(n=850) and diabetic(n=50) groups vascular compliance using the second derivative of PPG waveform in this study. The evaluated factors of the second derivative of PPG are 'a', 'b', 'c', 'd', 'e' and b/a rapresents vascular compliance. This study found out that when vascular compliance is decreased, the absolute value of b/a is decreased. The average vascular compliance of 50 diabetic patients with neuropathy, $-1.09{\pm}0.14$ is statistically lower than the normal group, $-0.81{\pm}0.09$ (p<0.05). In conclusion, we suggest an objective evaluation of peripheral vascular compliance for diabetic patients and prevention of vascular complication.

The Effect of Depression and Self-efficacy on the Quality of Life (요양병원 입원노인의 우울과 자아효능감이 삶의 질에 미치는 영향)

  • Kwag, Sung-Won;Sim, Kyoung-Bo;Roh, Heo-Lyun;Kim, Dong-Hyun
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.8 no.1
    • /
    • pp.23-31
    • /
    • 2018
  • Objective : Purpose of this study was to investigate the effect of depression and self - efficacy on the quality of life of the elderly hospitalized in a nursing hospital and to suggest a new direction for improving the quality of life of the elderly. Methods : The target was 212 senior citizens who were hospitalized at a nursing hospital located in K city in North Gyeongsang Province. The questionnaire was structured by adding the characteristics of the subjects, the Korean Senior Depression Index (GDS-K), the Self-effective Index (WHQOL-BRFA), and the World Health Organization's Life-Enhanced scale. coded using SPSS ver.18, the depression, self-efficiency, and quality of life differences according to the general characteristics (t-test, ANOVA), and Self-efficacy, depression, and the correlation coefficient between quality of life and A multI-sentence analysis to see the impact of depression and self-efficacy on the quality of life. Results : Self - efficacy and depression according to subject characteristics were different according to length of stay, and quality of life was different in religion. The correlation between depression, self - efficacy, and quality of life of admitted elderly showed statistically significant negative correlation (p <.01) with depression in both the quality of life and self - efficacy sub - variables. The depression and the self - efficacy of the elderly had the greatest effect on the quality of life. The variables were depression (${\beta}=-.328$), social efficacy (${\beta}=.248$), and physical efficacy (${\beta}=.193$). Conclusion : In order to improve the quality of life of the elderly, it will be necessary to provide and develop medical care services that reduce depression and improve self - efficacy (physical and social).

Study on Mock-up Properties of Concrete using Blast Furnace Slag and Recycled Aggregate (고로슬래그와 재생골재를 사용한 콘크리트의 실물대 특성에 관한 연구)

  • Park, Hyun;Han, Da-Hee;Park, Moo-Young;Kim, Woo-Jae;Lee, Young-Do;Jung, Sang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.789-792
    • /
    • 2008
  • Blast furnace slag doesn't have self-hydraulicity and it needs stimulants such as alkali to hydrate. Therefore using recycled aggregates erupted calcium hydroxides and blast furnace slag acquiring alkali stimulate could make a complementarily use of a recycling architectural material possible. In this study, we have discussed about characters of blast furnace slag and recycled aggregate firstly, and make recycled aggregate mortar and concrete using blast furnace slag for the experiment. The experiment is about mortar and concrete using recycled aggregate as a substitutional material of blast furnace slag. In this experiment, I replace blast furnace slag and aggregate with recycled aggregate. Conclusions through the test results analysis are as follows. And then, we added field experiment using concrete with composited materials.

  • PDF

A STUDY ABOUT EARLY OSTEOCONDUCTIVITY OF POROUS ALLOPLASTIC CARBONAPATITE AND ANORGANIC BOVINE XENOGRAFT IN CANINE MAIXLLIARY AUGMENTATION MODEL (탄산아파타이트로 된 인공골과 소뼈에서 유래한 무기질 골의 초기 골전도에 대한 연구)

  • Kim, Do-Kyun;Cho, Tae-Hyung;Song, Yun-Mi;Pan, Hui;Lee, Su-Yeon;Jin, Im-Geon;Kim, In-Sook;Hong, Kug-Sun;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.6
    • /
    • pp.485-493
    • /
    • 2007
  • Introduction: Although several types of calcium-phosphate coumpound have been frequently applied to osseous defects at maxillofacial area for many years, there is a controversy about its efficiency on bone conductivity comprared to xenograft bone substitute. Alloplastic carbonapatite has been introduced to improve disadvantages of hydroxyapatite and to mimic natural bone containing carbon elements. However, a preclinical study about its efficiency of osteoconductivity has not been reported. This study was performed to evaluate the early osteoconductive potential of synthetic carbonapatite with multiple pores relative to anorganic bovine xenograft. Materials and methods: Total 5 beagle dogs were used for maxillary augmentation model. The control (anorganic bovine xenograft) and experimental groups (synthetic carbonapatite) were randomly distributed in the mouth split design. After bone graft, all animals were sacrificed 4 weeks after surgery. Histological specimens with Masson Trichrome staining were made and histomorphometrically analysed with image analyser. The statistical analysis was performed using paired t-test. Results: In both groups, all animals had no complications. The experimental group showed relatively much new bone formation around and along the bone substitutes, whereas it was clearly reduced in the control group. The ratios of new bone area to total area, to material area and to the residual area excluding materials were higher in the experimental group ($0.13{\pm}0.03,\;0.40{\pm}0.13,\;0.20{\pm}0.06$ respectively) than in the control group ($0.01{\pm}0.01,\;0.03{\pm}0.02,\;0.03{\pm}0.03$, respectively). And the differences between both groups were statistically significant (p<0.001, <0.01, <0.01, respectively), while the ratio of material area to total area in two groups was not significant. Conclusion: Carbonapatite showed a high osteoconductivity in the early stage of bone healing compared to bovine derived anorganic bone substitute. This study suggests that this bone materials can be applied as a reliable bone substitute in the clinical treatment.

A Comparison of shear Bonding Strength with Polyacrylic acid and Phosphoric acid Enamel Surface Conditioning (폴리아크릴산과 인산으로 법랑질표면 처리후 전단결합강도의 비교)

  • Roh, Joung-Sub;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.32 no.1 s.90
    • /
    • pp.51-57
    • /
    • 2002
  • The purpose of this study was to compare in vitro shear bonding strength with three different enamel surface preparations (1) 30% sulfated polyacrylic acid with 0.3M lithium sulfate (2) 40% sulfated polyacrylic acid with 0.3M lithium sulfate (3) 37% phosphoric acid. 105 extracted human premolar teeth were divided into each three groups of 35. Metal brackets were bonded to teeth in the three groups. The same self curing resin was used for all groups. A shearing force was applied to the teeth. After debonding, bases of bracket and enamel surfaces were examined under steroscopic microscope to determine the failure modes. Statistical analysis of the data was carried out with one way ANOVA and Student t- test. The results were as follows. 1. Shear bond strength values for the 30% polyacrylic acid and 40% polyacrylic acid group were approximately two thirds of the phosphoric acid group. It maintains clinically acceptable but not enough bond strength. 2. There was no statistically significant difference in shear bond strengths between 30% and 40% polyacrylic acid group. 3. The failure modes of brackets had some differences. In polyacrylic acid groups, the percentage of adhesive/enamel failure was higher than that of adhesive/ bracket interface failure. On the contrary in phosphoric acid groups, the results were reversed. Further study of bond strength could be required. If polyacrylic acid enamel conditioning is used clinically.

Comparison of measurements from digital cephalometric radiographs and 3D MDCT-synthetized cephalometric radiographs and the effect of head position (디지털 측방두부규격방사선사진과 MDCT의 3차원 재구성 영상을 이용한 합성측방두부규격방사선사진의 계측치 비교 및 머리 위치가 미치는 효과)

  • Kim, Mi-Ja;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-SUk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.133-147
    • /
    • 2009
  • Purpose : To investigate the reproducibilities and compare the measurements in digital and MDCT-synthesized cephalometric radiograph, and to investigate the effect of head position on the measurement during imaging with MDCT. Materials and Methods : Twenty-two dry skulls (combined with mandible) were used in this study. Conventional digital cephalometric radiograph was taken in standard position, and MDCT was taken in standard position and two rotated position ($10^{\circ}$ left rotation and $10^{\circ}$ right tilting). MDCT data were imported in $OnDemand^{(R)}$ and lateral cephalometric radiograph were synthesized from 3D virtual models. Two types of rotated MDCT data were synthesized with default mode and with corrected mode using both ear rods. For all six images, sixteen angular and eleven linear measurements were made in V-$Ceph^{(R)}$ three times. Reproducibility of measurements was assessed using repeated measures ANOV A and ICC. Linear and angular measurements were compared between digital and five MDCT-synthesized images by Student t-test. Results : All measurements in six types of cephalometric radiograph were not statistically different under ICC examination. Measurements were not different between digital and MDCT-synthesized images (P>.05). Measurements in MDCT-synthesized image in $10^{\circ}$ left rotation or $10^{\circ}$ right tilting position showed possibility of difference from digital image in some measurements, and possibility of improvement via realignment of head position using both ear rods. Conclusion : MDCT-synthesized cephalometric radiograph can substitute conventional cephalometric radiograph. The error on head position during imaging with MDCT have possibility that can produce measurement errors with MDCT-synthesized image, and these position error can be corrected by realignment of the head position using both ear rods.

  • PDF

A Study on the Loss of Tooth Substance and Surface Changes following Root Planing (치근면 활택술후 치질삭제와 표면형태변화에 관한 연구)

  • Heo, Soo-Rye;Kim, Soo-Ah;Seo, Seok-Ran;Kim, Hyoug-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.2
    • /
    • pp.351-372
    • /
    • 1998
  • The purpose of this study was to evaluate in vitro effects of the loss of tooth substance and root surface changes following root planing with various periodontal instruments. The 39 extracted human teeth due to severe periodontal disease were included. The total 50 root surfaces of 30 teeth were root planed with following instruments : Group 1, with Gracey curette, Group 2, with ultrasonic scaler, Group 3, with rotating root planing bur, Group 4, with Gracey curette plus rubber cup polishing, and Group 5, with ultrasonic scaler plus rubber cup polishing. Following root planing, the amount of tooth substance loss was evaluated by measuring the weight of the removed tooth substance and then 5 specimens ($5{\times}5{\times}2mm$) were randomly selected from the each group for roughness measurement. Root planed areas of each specimen were subjected to five measurements using the Profilometer and an average surface roughness values(Ra) for each group was obtained. Statistical difference for roughness values of each group was analyzed using oneway ANOVA and student t-test. For scanning electron microscopic(SEM) examination of root surface changes following root planing, 15 root surfaces of remaining 9 teeth were root planed and 3 specimens were randomly selected. The mean loss of tooth substance removed was Group 1, $7.0{\pm}1.09mg$, Group 2, $1.3{\pm}1.00mg$, Group 3, $5.8{\pm}1.72mg$, Group 4, $8.7{\pm}1.34mg$, and Group 5, $4.5{\pm}1.68mg$ following root palning, respectively. These results indicate that curette is effective instrument in the respect of diseased root substance removal. The average surface roughness values are following results : Group 1 and Group 4 were the smoothest surface ($Ra=0.34{\pm}0.06{\mu}m$, $Ra=0.34{\pm}0.04{\mu}m$, respectively) and Group 2 was the roughest surface ($Ra=2.09{\pm}0.06{\mu}m$). Statistical analysis of roughness values demonstrated a highly significant difference (P<0.05) between each experimental groups. However, no statistically significant difference in roughness values were observed between the Group 1 and Group 4. The results in this study suggest that curette and/or polishing procedure should be done after root planing with ultrasonic scaler and caution should be used with dia-mond-coated bur during routine root planing procedure.

  • PDF

STATISTICAL STUDY ON OPTIMAL PLACEMENT OF IMMEDIATE DENIAL IMPLANTATION USING DENTA $SCAN^R$ (Denta $Scan^R$을 이용한 즉시 임플랜트 시술시 최적의 식립 위치 대한 통계적 연구)

  • Shin, Kwang-Ho;Lee, Jai-Bong;Hwang, Byung-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.4
    • /
    • pp.552-560
    • /
    • 2000
  • Purpose : The purpose of this study was to determine proper position and angulation of an implant for immediate implantation. Materials and Method : From the years 1997 to 2000. 52 Denta $scan^R$ views, 22 upper and 32 lower jaw with an average age of 43 and 40 respectively, were investigated, which comprise intact upper and lower 6 anterior teeth and premolars. On the Denta $scan^R$, the optimal placement for the immediated implantation was simulated. The measuring methods included 1) Angulation difference between tooth long axis and alveolar bone process. 2) Angulation difference of long axis between tooth and installing fixture 3) Distance between center of tooth at cervical area and center of fixture. 4) Distance from root apex to the bone limit of vital structure. One sample t-test was used for statistical analysis. Result : The results were as follows. 1) At the maxillary central incisor and lateral incisor, angulation difference of long axis between tooth and installing fixture was respectively 0.5 and 3.2 degrees with the fixture center's palatally positioned 2mm apart from tooth center. 2) At the lower anterior 6 teeth, that was about $-2.8^{\circ}\;to\;-4.6^{\circ}$ with the fixture center's lingually positioned 1mm apart from tooth center. 3) At the maxillary canine and premolar, that was respectively $11.8^{\circ}\;and \;7.2^{\circ}$ with the fixture center palatally positioned $2\sim2.4mm$ apart from tooth center. 4) At the lower premolar area, that was about $0^{\circ}\;to\;2^{\circ}$ with the fixture center's lingually positioned $0.5{\sim}1mm$ apart from tooth center. 5) Distance from root apex to the bone limit of vital structure, at the maxillary anterior and premolars. was the range of 10 to 12mm, and at the mandibular anterior teeth and the 1st premolar, that was the range of 18 to 20mm. Conclusion : The proper implant position of maxillary anterior and premolar teeth is as paralleled as or more buccally angulated than long axis of tooth with the fixture center's palatally positioned. In mandiblular anterior region, long axis of implants is lingully angulated compared with long axis of tooth and in premolar, almost parelleled with long axis of tooth and alveolar process.

  • PDF