• Title/Summary/Keyword: T-plate

Search Result 1,307, Processing Time 0.029 seconds

A Study on the Vibration Analysis of a Deckhouse of Fishing Vessel (어선의 갑판실의 진동 해석법에 관한 연구)

  • 배동명
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.27 no.3
    • /
    • pp.193-210
    • /
    • 1991
  • For the deckhouse or superstructure, attention is directed to the reduction of vibration from a human susceptibility point of view. The two basic requirements for obtaining a low vibration level in the accommodation are to ensure that excitation forces from propeller and/or main engine are small and to avoid resonance excitation of the hull and superstructure. In recent years increased attention has been directed towards the problems of vibration and noise in deckhouse, which have caused major problems with regard to the environmental quality in the living quarters for crews. Accordingly, in this paper, the characteristic of the vibration of deckhouse of fishing boat, of which the length/height ratio is also relatively high, are studied systematically with regard to the shape and modelling of deckhouse based on finite element method of 1-dimensional, 2-dimensional and 3-dimensional model. This study is divided into 4-part. 1st part is the global deckhouse vibration, 2nd part is the local deckhouse vibration, 3rd part consists of the estimation for stiffness of foundational support and 4th part is the application to TUNA LONG LINER of 416 ton class. For the global vibration analysis, the severity of the vibration depends on the longitudinal shear and bending stiffness of the deckhouse, on the vertical deckhouse support(fore, aft and sides). However, even if the design is technically sound, vibration problems may arise due to vertical or longitudinal hull girder or afterbody resonances. Author applied the method of this study to the analysis of, deep-sea fishing vessel of G.T. 416 ton class with relatively low height and long deckhouse, and investigated the vibrational characteristic of the fishing vessel with earlier structural feature. According to this investigation, the vibration, response of above vessel was confirmed of which main hull and deckhouse behave as one body. It is at the bottom of vibrational trouble which a accommodation part of the fishing vessel is raised, that is the local vibration for side wall, fore-aft wall and deck plate of deckhouse rather than thief fect of fore-aft vibration of deckhouse for above fishing vessel. and the resonance of main hull, deckhouse and driving system such as the main engine, propeller in exciting source is mainly brought up as the trouble.

  • PDF

A STUDY ON PHYSICAL PROPERTIES OF INTEROCCLUSAL RECORDING MATERIALS (악간 기록재료의 물리적 특성에 관한 연구)

  • Kang, Jeong-Kil;Yu, Hyoung-Woo;Ahn, Seung-Geun;Song, Kwang-Yeob;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.4
    • /
    • pp.657-664
    • /
    • 1996
  • The purpose of this study was to compare the dimensional stability, compression resistance, elastic recovery and surface hardness of elastomeric interocclusal recording materials. Five commonly used elastomeric interocclusal recording materials(Ramitec, Regisil, Blue-Mousse, Stat-Br, Coltoflax) were selected for this study. According to ADA specification No. 19, two types of specimen were fabricated. Cylinder type specimens were used to test compression resistance and elastic recovery and plate type specimens were used to evaluate dimensional stability and surface hardness. Paired t-test was applied to detect significance among the occlusal registration materials. The obtained results were as follows: 1. There were statistical difference in dimensional stability between the elastic interocclusal recording materials. The dimensional stability of silicone was higher than that of polyether tested(p<0.05). 2. Coltoflax was significantly less resistance to compression than the other elastic interocclusal recording materials(p<0.001). 3. The elastic recovery capacity of Blu-Mousse and Stat-Br is better than that of Coltoflax (p<0.01). 4. The surface hardness of Coltoflax was lower than that of Blu-Mousse and Stat-Br(p<0.05). 5. The percentage dimensional change of alll materials was acceptable according to the limid of 0.5% suggeted by ADA specificatin No. 19.

  • PDF

A novel retentive type of dental implant prosthesis: marginal fitness of the cementless double crown type implant prosthesis evaluated by bacterial penetration and viability

  • Hong, Seoung-Jin;Kwon, Kung-Rock;Jang, Eun-Young;Moon, Ji-Hoi
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.233-238
    • /
    • 2020
  • PURPOSE. This study aims to compare the marginal fitness of two types of implant-supported fixed dental prosthesis, i.e., cementless fixation (CL.F) system and cement-retained type. MATERIALS AND METHODS. In each group, ten specimens were assessed. Each specimen comprised implant lab analog, titanium abutment fabricated with a 2-degree tapered axial wall, and zirconia crown. The crown of the CL.F system was retained by frictional force between abutment and relined composite resin. In the cement-retained type, zinc oxide eugenol cement was used to set crown and abutment. All specimens were sterilized with ethylene oxide, immersed in Prevotella intermedia culture in a 50 mL tube, and incubated with rotation. After 48 h, the specimens were washed thoroughly before separating the crown and abutment. The bacteria that penetrated into the crown-abutment interface were collected by washing with 500 µL of sterile saline. The bacterial cell number was quantified using the agar plate count technique. The BacTiter-Glo Microbial Cell Viability Assay Kit was used to measure bacterial adenosine triphosphate (ATP)-bioluminescence, which reflects the bacterial viability. The t-test was performed, and the significance level was set at 5%. RESULTS. The number of penetrating bacterial cells assessed by colony-forming units was approximately 33% lower in the CL.F system than in the cement-retained type (P<.05). ATP-bioluminescence was approximately 41% lower in the CL.F system than in the cement-retained type (P<.05). CONCLUSION. The CL.F system is more resistant to bacterial penetration into the abutment-crown interface than the cement-retained type, thereby indicating a precise marginal fit.

Vibration Analysis of Mindlin Plates Using Polynomials Having the Property of Timoshenko Beam Functions (Timoshenko보함수 성질을 갖는 다항식을 이용한 Mindlin판유추 구조계의 진동해석)

  • J.H. Chung;T.Y. Chung;K.C. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.1
    • /
    • pp.158-172
    • /
    • 1992
  • In ships and offshore structures, there are many local structures formed of thick plates and/or having the form of double wall panels. For the vibration analysis of such a kind of structures, Mindlin plate theory which includes the effects of shear deformation and rotary inertia is usually adopted. In this paper, the vibration and dynamic sensitivity analysis of Mindlin plates having the boundary conditions elastically restrained against rotation have been accomplished using the Rayleigh-Ritz method. Polynomials having the property of the Timoshenko beam functions are introduced and used as trial functions in the spatial representation of the deflection and rotations of cross sections in two directions of the plates. The results obtained by the introduced polynomials gave nearly the same numerical results as those by the Timoshenko beam functions with the remarkable reduction of computational efforts especially in the dynamic sensitivity analysis.

  • PDF

Surgical Correction of an Antebrachial Deformity with Severe External Rotation in Two Dogs (심각한 외측 회전을 동반한 전완 기형의 외과적 교정 치료 2 증례)

  • Yoon, Hun-Young;Roh, Mi-Young;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.28 no.3
    • /
    • pp.328-331
    • /
    • 2011
  • Two dogs presented to the Dueckso Animal Hospital with a history of intermittent lameness of the left forelimb. On physical examination, a visible antebrachial deformity that resulted in gross external rotation of approximately $90^{\circ}$ was observed in two dogs. Medial-lateral radiographic views revealed distal ulnar subluxation, cranial bowing of the radius, radial and ulnar shortening, and external rotation of the paw. A distal ulnar ostectomy and distal radial closing wedge osteotomy were performed in two dogs. A proximal ulnar osteotomy was performed, adjacent to the elbow joint in case 1. Then, the osteotomized site was supported with an intramedullary pin. A T-plate and cortical screws were applied to the proximal and distal radial segments after derotating the distal segment internally. Postoperative radiographic view verified the correction of the angular deformity in two dogs. The follow-up was completed by physical examination 6 and 10 months after surgery respectively. There was no evidence of lameness of the left forelimb in two dogs. Gross observation of the limb revealed an apparent appropriate correction of the rotational and angular deformity in two dogs.

Change in Risk of Dropout Due to Bleeding during Bloodletting-Cupping Therapy (습식 부항 시술시 사혈량에 따른 부항 탈락 위험도 탐색)

  • Kim, Daehyeok;Bae, Eunkyung;Park, Jeonghwan;Kim, Soyoung;Lee, Sanghun
    • Korean Journal of Acupuncture
    • /
    • v.35 no.1
    • /
    • pp.41-45
    • /
    • 2018
  • Objectives : To investigate minimum pressure by verifying changes in pressure due to bleeding amount during bloodletting-cupping therapy. Methods : (1) We compared adhesion performance of four different cupping cups of same size: two disposable cupping cups(A, B) and two reusable cupping cups(A, B) each were vacuumed three times and kept in place for 10 minutes. (2) We vacuumed two different sized disposable cupping cups(A), size.1(InnerDiameter 48.8 mm) and size.3(InnerDiameter 39.1 mm), twice each(-200 mmHg) on silicon plate. We injected water and air at regular intervals in cupping cups by using a syringe, and then measured change of pressure in cupping cups and pressure at the time of dropout. Results : (1) Pressure reduction was $4.75{\pm}2.78%$ on average in the order of 'Disposable[A]>reusable[B]>Disposable[B]>reusable[A]', so that pressure retention performance of disposable cups can't be regarded as inferior to that of reusable cups. (2) Pressure of disposable cupping B(size.1) decreased by an average of -40.08 mmHg per 5 ml of water. At -24.8 mmHg, when 22 ml of water has been injected, cup has come off. Pressure of disposable cupping B(size. 3) decreased by an average of -99.4 mmHg per 5 ml of water. At -48.6 mmHg, when 13 ml of water was injected, cupping came off. Conclusions : Considering reduction rate of pressure due to water injection, in case of bleeding more than 15 ml, size.3 cup always comes off, therefore it needs to be re-operated at least once. Meanwhile, size.1 cup does not always come off in the same condition, depending on the initial pressure and therefore, re-operation may be considered.

An Experimental Study on the Shear Bond Strength of Fluoride-Containing Sealant and Non-Fluoride Containing Sealant (불소함유여부에 따른 치면열구전색제의 전단결합강도에 관한 실험적 연구)

  • Her, Sun;Kweon, Seon-Ja;Kim, Jae-Gon;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.2
    • /
    • pp.489-501
    • /
    • 1996
  • This study was to evaluate shear bond strength of fluoride-releasing sealant and nonfluoride releasing sealant to enamel surface of bovine tooth. 80 extracted bovine teeth were randomly assigned to four groups, and four kinds of sealants including Teethmate-A(Kuraray Co.), Teethmate-F(Kuraray Co.), Helioseal(Vivadent Co.), Helioseal-F(Vivadent Co.) were bonded to exposed enamel surfaces using silicon plate. Shear bond strength was determined in an instron universal testing machine at a crosshead speed of 1mm/min. Then, the fracture surfaces of test specimens were investigated with scanning electron microscope. The obtained results were as follows; 1. The shear bond strength decreased in the following order : Teethmate-A(18.31MPa), Teethmate-F(11.90MPa), Helioseal (11.74 MPa), Helioseal-F(10.64MPa). 2. The shear bond strength of Teethmate-A showed significantly higher than that of Teethmate-F(P<0.05), but Helioseal and Helioseal-F didn't showed statistically different(P<0.05). 3. According to the SEM, Teethmate-A group showed cohesive failure, and Teethmate-A group & Helioseal group showed mixed pattern of cohesive and adhesive failure and Helioseal-F group showed adhesive failure.

  • PDF

Solubility of Tin in Canned Marine Foods on the Market (市內에 있는 韓國産 水産통조림中의 주석 (Sn) 湧出量)

  • Chong Hun Won
    • Journal of the Korean Chemical Society
    • /
    • v.6 no.1
    • /
    • pp.25-28
    • /
    • 1962
  • The colorimetric estimation, by dithiol method, of the solubility of tin dissolved from the container the tin plate in some canned marine foods has been made on 200 cans of sample on the market. Some of them contained more than 150 ppm of Sn concentration were as follows; (1) ca. 50% of squid can, (2)ca. 30% of mackerel can, (3) ca. of saury can, (4) naught of crab, whale, clam(Japanese hard clams), fish meat ball, and Turbo cornutus one. (1) It had the tendency of increasing Sn concentration according to lowering or arising the value of pH. (2) No significant difference in Sn concentration was caused by the variation of the sort of tinning as H-D or E-T. (3) The longer the period of the storage the higher Sn concentration was found, and the concentration more than 150 ppm of Sn was generally found among the cans stored more than twelve months. (4) The concentration of Sn in the liquid was higher than in solid portion, and most of dissolved Sn was distributed in the liquid portion.

  • PDF

Rate-Dependence of Off-Axis Tensile Behavior of Cross-Ply CFRP Laminates at Elevated Temperature and Its Simulation

  • Takeuchi, Fumi;Kawai, Masamichi;Zhang, Jian-Qi;Matsuda, Tetsuya
    • Advanced Composite Materials
    • /
    • v.17 no.1
    • /
    • pp.57-73
    • /
    • 2008
  • The present paper focuses on experimental verification of the ply-by-ply basis inelastic analysis of multidirectional laminates. First of all, rate dependence of the tensile behavior of balanced symmetric cross-ply T800H/epoxy laminates with a $[0/90]_{3S}$ lay-up under off-axis loading conditions at $100^{\circ}C$ is examined. Uniaxial tension tests are performed on plain coupon specimens with various fiber orientations $[{\theta}/(90-{\theta})]_{3S}$ ($\theta$ = 0, 5, 15, 45 and $90^{\circ}C$) at two different strain rates (1.0 and 0.01%/min). The off-axis stress.strain curves exhibit marked nonlinearity for all the off-axis fiber orientations except for the on-axis fiber orientations $\theta$ = 0 and $90^{\circ}$, regardless of the strain rates. Strain rate has significant influences not only on the off-axis flow stress in the regime of nonlinear response but also on the apparent off-axis elastic modulus in the regime of initial linear response. A macromechanical constitutive model based on a ply viscoplasticity model and the classical laminated plate theory is applied to predictions of the rate-dependent off-axis nonlinear behavior of the cross-ply CFRP laminate. The material constants involved by the ply viscoplasticity model are identified on the basis of the experimental results on the unidirectional laminate of the same carbon/epoxy system. It is demonstrated that good agreements between the predicted and observed results are obtained by taking account of the fiber rotation induced by deformation as well as the rate dependence of the initial Young's moduli.

Forming Tool Design of Outer Shell Structure of Nozzle Extension for Thrust Chamber (연소기 노즐확장부 외피구조물 성형치구 설계)

  • Ryu, Chul-Sung;Lee, Keum-Oh;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.271-275
    • /
    • 2010
  • Forming tool design is carried out for a manufacturing a outer shell structure of the nozzle extension of regenerative cooling thrust chamber. The method which manufactures outer shell structure of nozzle extension is a metal forming process using thin plate. Because the configuration of outer shell structure is changed after forming process by springback effect, the outer shell structure can't be exactly formed with the same forming tool as configuration of the nozzle extension. Therefore forming tool design considering springback effect is necessary for manufacturing the outer shell structure of the nozzle extension. In this study, new designed forming tool configuration was generated to decrease the errors between nozzle contour and formed structure. The analysis results show that the errors between nozzle contour and formed structure is significantly decreased using the new designed forming tool.

  • PDF