• Title/Summary/Keyword: T-pipe

Search Result 397, Processing Time 0.029 seconds

The Structural Lineage of Palsangjeon in Pubjoo Temple Analyzed through Gilt-bronze Pagoda in the Koryo Period (고려(高麗) 금동탑(金銅塔)을 통해 본 법주사(法主寺) 팔상전(捌相殿)의 구조형식계통(構造形式系統))

  • Kim, Kyeong-Pyo
    • Journal of architectural history
    • /
    • v.14 no.1 s.41
    • /
    • pp.89-105
    • /
    • 2005
  • The central aim of this thesis is to see if the structure of Palsangjeon(捌相殿) in Pubjoo Temple(法住寺), a five sto wooden pagoda in Chosen(朝鮮) Dynasty, was handed down from the ancient and middle ages. This study was performed through an analysis of Gilt-Bronze Pagoda built in Koryo(高麗) period. In other words, it is aimed at analyzing which lineage the structure of Palsangjeonbelongs to as a wooden pagoda. In analyzing the structure of Palsangjeon, I attempted to find out its source from the remains of Koryo period prior to the Chosen Dynasty. Examples are the Gilt-Bronze Pagoda, built during the Koryo period. I have also examined its relationship with other existing wooden pagodas and remains. The analysis of Palsangjeon, a five story wooden pagoda in Chosen Dynasty, focuses on the following: First, I explored the possibilities of whether the structure of Palsangjeon was newly invented in Chosen Dynasty, or if it had been derived from the wooden pagodas in the Koryo period. Secondly, I tried to find out if the stable vertical planes, with a great successive diminution ratio, were derived from the middle age, i.e. Koryo period. The results of the study of Palsangjeon through Gilt-Bronze Pagoda analysis are as follows: 1. The structure of Gilt-Bronze Pagoda, a wooden pagoda from the Koryo period, is roughly classified into the accumulation type, using pipe pillars, and the one story type using whole pillars. In the accumulation type, stories are connected in either a flat format or an intervening format. The Gilt-Bronze Pagoda is mainly composed of pipe pillars, with some whole pillars. However, the central pillar was omitted in the building structure. Generally, the upper and lower stories are connected by pipe pillars in a crutch format. All the pillars, whether they are pipe pillars or whole pillars, used Naiten(內轉) technology. The Eave supporter has the Haang type(下昻) and the Muhaang type(無下昻). In most cases, high balustrades are furnished, but few tables of high balustrades have been found. The slanting roof formats have been handed down from Paekche(百濟), Silla(新羅), or Koryo(高麗). However, the structure of the octagon is assumed to be derived from Koguryo(高句麗). The structure of the Gilt-Bronze Pagoda from the Koryo period is mainly composed of accumulated flat squares, with some spire types. intervening format, the structure of Palsangjeon used whole pillars in a half story format in which upper level side pillars are installed on the lower level tie beam. From the Bronze Pagoda from the Koryo period, we can assume that the half story format of wooden pagodas that has stable vertical planes with a great successive diminution ratio was created during the mid-Koryo period at the latest and had been idly developed by the time of the Chosen Dynasty. 3. The whole pillars in Palsangjeon are also found in Gilt-Bronze Pagodas from the Koryo period. Hence, all of the pillars in Palsangjeon seem to have been handed down from the ancient construction technology. They were also used in the construction of wooden pagodas from the Koryo period. Therefore, it is assumed that Palsangjeon was constructed using the construction technology of the Chosen Dynasty that had been developed from the wooden pagoda construction technology of the Koryo period. The stable vertical planes with a great successive diminution ratio in Palsangjeon are derived from ancient Korean wooden pagodas, which have developed into indigenous Korean wooden pagodas with fairly stable vertical planes and a great design, in the half story format of Koryo and Chosen Dynasty. Therefore, it is assumed that the structure of Palsangjeon has a systematic relationship with traditional Korean wooden pagodas and is one of the indigenous Korean wooden pagoda structures. 4. In China, the intervening format has been mainly used between stories in multi-story architecture since the ancient days. At the same time, the flat format as also used in ancient and middle ages. However, the flat format was replaced by whole pillars during the Ming(明) and Manchu(淸) Dynasties, in favor of simple and compact construction. The half-story format, in which upper level side pillars are installed on tie beams, has been found in some cases, but it doesn't seem to have been the primary construction technology. Few traces of the half-story format have been found in multi-story architecture in Japan, and it has not been used as a general construction format. By contrast, the half-story format, which seems to have been derived from the Koryo period, was used as a general construction format in multi-story architecture of the Chosen Dynasty. The construction technology of multi-story architecture is related to that of multi-story wooden pagodas, but they have different production technologies. It seems that the structure of Palsangjeon did not just adopt the construction technology of multi-story architecture in the Chosen Dynasty, but it was developed from wooden pagodas in the Koryo period, including the Gilt-Bronze Pagoda. 5. Since the ancient days, most Chinese and Japanese wooden pagodas have adopted an accumulation type of structure using pipe pillars, with accumulated pointed towers. On the other hand, though most Korean wooden pagodas have also adopted an accumulation type of structure from the ancientdays, one story type using whole pillars was created in the Koryo and Chosen Dynasties. The wooden pagoda structure of Palsangjeon, with stable vertical planes in a half story format, is a unique Korean construction technology, different from the construction technologies of Chinese and Japanese wooden pagodas. This thesis clearly determined the structural characteristics of Palsangjeon. However, various remains have yet to be analyzed in depth, to establish an accurate construction technology system. In the beginning of this thesis, I had difficulty in precisely interpreting the internal structure of the Gilt-Bronze Pagoda from its appearance. However, in the process of study, the more serious problem was that there are few remains or ruins of multi-story architecture in ancient and the middle ages of Korea. Therefore, it is urgent to discover various remains in the future. This thesis succeeded in determining the structural characteristics of Palsangjeon. However, it fell short of clarifying the structural lineage of the stable vertical planes, although they show indigenous Korean architectural taste, representing the unique national emotion, and the construction format of multi-story wooden pagodas in Korea. I hope this is clarified in the future research.

  • PDF

Evaluation of Structural Stability of Plastic Greenhouses with Steel Spiral Piles on Reclaimed Lands (간척지에서 강재 나선말뚝기초를 적용한 플라스틱 온실의 안전성 평가)

  • Yum, Sung Hyun;Lee, Won Bok
    • Journal of Bio-Environment Control
    • /
    • v.26 no.1
    • /
    • pp.27-34
    • /
    • 2017
  • This study was carried out to estimate structural stabilities in respect of ground footings of plastic greenhouses on reclaimed lands. A 6m-wide multi-span plastic greenhouse with steel spiral piles as well as two 8.2m-wide single-span greenhouses with steel spiral piles and continuous pipe foundation respectively were built up on a reclaimed land with a SPT N-Value of 2 and measured how much the greenhouses were lifted up and subsided. In addition, the uplift capacity of three kinds of spiral piles(${\phi}50$, ${\phi}75$ and ${\phi}100$) was determined on a nearby reclaimed land. The results showed that the greenhouses with spiral piles had a slight vertical displacement like moving up and down but the scales of the rising up and sinking were negligible when compared to that of the greenhouses. The vertical displacement of the multi-span greenhouse ranged from +9.0mm(uplift) to -11.5mm(subsidence). As for the single-span greenhouses with spiral piles and continuous pipe foundation, the measurements showed that it varied from +1.3mm to -7.7mm and from +0.9mm to -11.2mm, respectively. The allowable uplift capacity of spiral piles could all be determined under criteria of ultimate load and accordingly had a value of 0.40kN, 1.0kN and 2.5kN, respectively. It was not entirely certain enough to make a final judgement on structural stabilities in respect of ground footings, it appeared likely however that the greenhouses with steel spiral piles was tentatively observed without any problems on reclaimed lands within the period.

A Study on Application Design Scenarios for the Gas Safety Field Workers -focused on the pipe work- (가스 작업 안전 앱 시나리오 설계에 대한 연구 -배관 작업을 중심으로-)

  • Lee, Jooah;Kim, Mi-Hye;Kang, Bong Hee
    • Journal of Digital Convergence
    • /
    • v.14 no.5
    • /
    • pp.273-281
    • /
    • 2016
  • The issue about the safety management of gas related work has been studied toward a direction to utilize IoT system recently. For this purpose, the matters of user's demand has been deduced through the literature survey, field survey, and professional consultation, by studying the characteristics of worker, work, and work site. In summary, these are the demands for mobile App, 1)a clear arrangement of contents, 2)a design with high readability, 3)a design with low death, 4) securing of user's accessibility, 5)an effective information transmission plan in the work section where it is impossible to operate the mobile device, 6)an activation of alarm function at the section of high working error, 7)a fast two-way transmission and receipt of safety inspection matter needed at work, 8)a selection of images and contents that can guide the situation to the worker in case of accident, 9)an alarm function for the degree of danger in an area of worker's location. Based on these, a basic design of safety application for gas related work has been proposed, that can secure the user accessibility.

Biological Monitoring of Paint Handling Workers exposed to PAHs using Urinary 1-Hydroxypyrene (다핵방향족탄화수소류에 노출된 페인트 취급 근로자에서 요 중 1- Hydroxypyrene을 이용한 생물학적 모니터링)

  • Lee, Jong-Seong;Kim, Eun-A;Lee, Yong-Hag;Moon, Deog-Hwan;Kim, Kwang-Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.2
    • /
    • pp.124-134
    • /
    • 2005
  • To investigate the exposure effect of polynuclear aromatic hydrocarbons (PAHs), we measured airborne total PAHs as an external dose, urinary 1-hydroxypyrene (1-OHP) as an internal dose of PAHs exposure, and analyzed the relationship between urinary 1-OHP concentration and PAHs exposure. The study population contained 44 workers in steel-pipe coating and paint manufacture industries. The airborne PAHs was obtained during survey day, and urine were sampled at the end of shift. Personal information on age, body weight, height, eniployment duration, smoking habit, and alcohol consumption was obtained by a structured questionnaire. Airborne PAHs were analyzed by the gas chromatograph with mass selective detector. Urinary 1-OHP levels were analyzed by the high performance liquid chromatograph with ultraviolet wavelength detector. For statistical estimation, t-test, ${\chi}^2$-test, analysis of variance, correlation analysis, arid regression analysis were executed by SPSS/PC (Windows version 10). The mean of environmental total PAHs was $87.8{\pm}7.81{\mu}g/m^3$. The mean concentration ($526.5{\pm}2.85{\mu}g/m^3$) of workers in steel-pipe coating industries using coal tar enamel was the higher than that ($17.5{\pm}3.36{\mu}g/m^3$) of workers in paint manufacture industries using coal tar paint. The mean of urinary 1-OHP concentration ($51.63{\pm}3.144{\mu}\;mol/mol$ creatinine) of workers in steel-pipe coating industries was the higher than that ($2.33{\pm}4.709{\mu}\;mol/mol$ creatinine) of workers in paint manufacture industries. The mean of urinary 1-OHP concentration of smokers was the higher than that of non-smokers. There was significant correlation between the urinary concentration of 1-OHP and the environmental concentration of PAHs (r=O.S48, p<0.001), pyrene(r=0.859, p<0.001), and urinary cotinine (r=0.324, p<0.05). The regression equation between the urinary concentration of 1-OHP in ${\mu}g/g$ creatinine($C_{1-OHP}$) and airborne concentration of PAHs (or pyrene) in ${\mu}g/m^3$ ($C_{PAHs}$ or Cpyrene) is: Log ($C_{1-OHP}$)=-0.650+0.889×Log($C_{PAHs}$), where $R^2=0.694$ and n=38 for p<0.001.Log ($C_{1-OHP}$)=1.087+0.707${\times}$Log(Cpyrene), where $R^2=0.713$ and n=38 for p<0.001. From the results of stepwise multiple regression analysis about 1-OHP, significant independents were total PAHs and urinary cotinine (adjusted $R^2=0.743$, p<0.001). In this study, there were significant correlation between the urinary concentration of 1-OHP and the airborne concentration of PAHs. The urinary 1-OHP was effective index as a biomarker of airborne PAHs in workplace. But it was influenced by non-occupational PAHs source, smoking.

Effect of Induction Heat Bending Process on the Properties of ASME SA106 Gr. C Carbon Steel Pipes

  • Kim, Ki Tae;Kim, Young Sik;Chang, Hyun Young;Oh, Young Jin;Sung, Gi Ho
    • Corrosion Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.47-53
    • /
    • 2015
  • Recently, the bending process is greatly applied to fabricate the pipe line. Bending process can reduce welding joints and then decrease the number of inspection. Thus, the maintenance cost will be reduced. Induction heat bending process is composed of bending deformation by repeated local heat and cooling. By this thermal process, corrosion properties and microstructure can be affected. This work focused on the effect of induction heating bending process on the properties of ASME SA106 Gr. C low carbon steel pipes. Microstructure analysis, hardness measurements, and immersion corrosion test were performed for base metal and bended area including extrados, intrados, crown up, and down parts. Microstructure was analyzed using an optical microscope and SEM. Hardness was measured using a Rockwell B scale. Induction heat bending process has influenced upon the size and distribution of ferrite and pearlite phases which were transformed into finer structure than those of base metal. Even though the fine microstructure, every bent area showed a little lower hardness than that of base metal. It is considered that softening by the bending process may be arisen. Except of I2, intrados area, the others showed a similar corrosion rate to that of base metal. But even relatively high rate of intrados area was very low and acceptable. Therefore, it is judged that induction heat bending process didn't affect boric acid corrosion behaviour of carbon steel.

THERMAL-FLUID ANALYSIS FOR COOLING PERFORMANCE IMPROVEMENT OF 3.3KV(105A) COMPACT RACK TYPE MEDIUM VOLTAGE INVERTER SYSTEM (3.3kV(105A) COMPACT RACK TYPE 고압 인버터 시스템의 방열 성능 향상을 위한 열유동 해석)

  • Kim, S.Y.;Kim, S.D.;Ryoo, S.R.;You, N.K.;Kim, T.B.;Hong, C.O.;Ko, H.S.
    • Journal of computational fluids engineering
    • /
    • v.19 no.3
    • /
    • pp.24-28
    • /
    • 2014
  • With ever rising concerns about saving of fossil fuel resource, there have been an increasing demand for use of energy more efficiently. The electric motor driven inverters can be a great help to improve energy efficiency. They are also used to control the motor speed to the actual need. Therefore the use of them can lead to reduce energy consumption. In particular, the medium voltage(MV) drive systems used for pumps, fans, steel rolling mills and tractions have widespread applications in the industry. They cover power ratings from 0.4MW to 40MW at the MV level of 2.3kV to 13.8kV. The majority of the installed MV drive systems however, are in the 1MW to 4MW range with voltage rating from 3.3kV to 6.6kV. But they are required to reduce size and weight like other power electronic equipments. In this paper, we studied on the 3.3kV(105A) compact rack type inverter system for improving the cooling efficiency. At first, we confirmed the tendency of temperature with computational simulation using ANSYS ICEPAK and actual experimental tests. And then we researched thermal performance improvement designs in order to reduce temperature of the transformer for the safe operation. It can reduce temperature of transformer that using pipe type flow guide in the system. As a result, we found out more efficient solution by thermal-fluid analysis.

Effects of Induction Heat Bending Process on Microstructure and Corrosion Properties of ASME SA312 Gr.TP304 Stainless Steel Pipes

  • Kim, Nam In;Kim, Young Sik;Kim, Kyung Soo;Chang, Hyun Young;Park, Heung Bae;Sung, Gi Ho
    • Corrosion Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.120-126
    • /
    • 2015
  • The usage of bending products recently have increased since many industries such as automobile, aerospace, shipbuilding, and chemical plants need the application of pipings. Bending process is one of the inevitable steps to fabricate the facilities. Induction heat bending is composed of compressive bending process by local heating and cooling. This work focused on the effect of induction heat bending process on the properties of ASME SA312 Gr. TP304 stainless steel pipes. Tests were performed for base metal and bended area including extrados, intrados, crown up, and down parts. Microstructure was analyzed using an optical microscope and SEM. In order to determine intergranular corrosion resistance, Double Loop Electrochemical Potentiokinetic Reactivation (DL-EPR) test and ASTM A262 practice A and C tests were done. Every specimen revealed non-metallic inclusion free under the criteria of 1.5i of the standard and the induction heat bending process did not affect the non-metallic inclusion in the alloys. Also, all the bended specimens had finer grain size than ASTM grain size number 5 corresponding to the grain sizes of the base metal and thus the grain size of the pipe bended by induction heat bending process is acceptable. Hardness of transition start, bend, and transition end areas of ASME SA312 TP304 stainless steel was a little higher than that of base metal. Intergranular corrosion behavior was determined by ASTM A262 practice A and C and DL-EPR test, and respectively step structure, corrosion rate under 0.3 mm/y, and Degree of Sensitization (DOS) of 0.001~0.075% were obtained. That is, the induction heat bending process didn't affect the intergranular corrosion behavior of ASME SA312 TP304 stainless steel.

EXHAUST GAS HEAT RECOVERY SYSTEM FOR PLANT BED HEATING IN GREENHOUSE PRODUCTION

  • Kim, Y.J.;Ryou, Y.S.;Rhee, K.J.;Kang, G.C.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.639-646
    • /
    • 2000
  • Hot air heater with light oil combustion is the most common heater for greenhouse heating in the winter season in Korea. However, since the heat efficiency of the heater is about 80%, considerable unused heat in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust gas heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The system consists of a heat exchanger made of copper pipes, ${\phi}\;12.7{\times}0.7t$ located inside the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tame The total heat exchanger area is $1.5m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to performance test it can recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690{\ell}$/hr from the waste heat discharged. The exhaust gas temperature left from the heat exchanger dropped to $100^{circ}C$ from $270^{circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{circ}C$ from $21^{circ}C$ at the water flow rate of $690{\ell}$/hr. And, the condensed water amount varies from 16 to $43m{\ell}$ at the same water circulation rates. This condensing heat recovery system can reduce boiler fuel consumption amount in a day by 34% according to the feasibility study of the actual mimitomato greenhouse. No combustion load was observed in the hot air heater.

  • PDF

An Investigation of Tensile Specimen Appearance for Slender Tubular Products by Copper (구리재질 세관(細管)의 인장시편 형상에 대한 고찰)

  • Kim S.Y.;Kim H.I.;Cho S.K.;Bae B.K.;Seok C.S.;Lee J.K.;Mo J.Y.;Park D.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.2001-2005
    • /
    • 2005
  • The tensile test is generally used to measure mechanical properties with conventional fracture test. This test is extremely certain method to measure Young's modulus, yield strength, tensile strength and so on. ASTM, by international standard, prescribes two classes of tensile tests in tubular products. One is method that specimens aren't done by any process with Tube-shape. The other is that specimens are made on process for C-shape. In this paper, we would like to present the new-shape specimens for the tensile test. The presented specimen's shape is that put two pieces of C-shape specimens together. Besides a load point and a support point are fixed like Tube-shape specimens. This shape of specimen has a difference that existing specimen is made on one-step process out this specimen is made on two-step process. This shape is considered that stress concentration phenomenon occurs at the reduced section if a specimen is made on one step process.

  • PDF

DNS STUDY ON THE FLOW CHARACTERISTICS THROUGH SIMPLE POROUS HYDRAULIC FRACTURES (평판형 수압파쇄 균열을 통과하는 다공질유동 특성에 관한 DNS 해석 연구)

  • Shin, C.H.;Park, W.G.
    • Journal of computational fluids engineering
    • /
    • v.21 no.4
    • /
    • pp.19-27
    • /
    • 2016
  • The flow analyses through a porous hydraulic fractures is among the most important tasks in recently developed shale reservoirs but is rendered difficult by non-Darcy effects and geometric changes in the hydraulic fractures during production. In this study, several Computational Fluid Dynamics(CFD) models of hydraulic fractures, with a simple shape such as that of parallel plates, filled with proppants were built. Direct Numerical Simulation(DNS) analyses were then carried out to examine the flow loss characteristics of the fractures. The hydraulic diameters for the simulation models were calculated using the DNS results, and then they were compared with the results from Kozeny's definition of hydraulic diameter which is most widely used in the flow analysis field. Also, the characteristic parameters based on both hydraulic diameters were estimated for the investigation of the flow loss variation features. Consequently, it was checked in this study that the hydraulic diameter based on Kozeny's definition is not accordant to the results from the DNS analyses, and the case using the CFD results exhibits f Re robustness like general pipe flows, whereas the other case using Kozeny's definition doesn't. Ultimately, it is expected that discoveries reported in this study would help further porous flow analyses such as hydraulic fracture flows.