• 제목/요약/키워드: T-joints

검색결과 489건 처리시간 0.024초

ATOS 80 고장력강의 보호가스량에 따른 용접부 방사선검사에 관한 연구 (A Study on Indications in Radiographic Tests in Welding Specimens According to Shielded Amounts of ATOS 80 High-strength Steel)

  • 백정환;최병기
    • 한국생산제조학회지
    • /
    • 제21권6호
    • /
    • pp.910-914
    • /
    • 2012
  • In constructing all kinds of equipment and steel structures, discontinuous areas such as weld defects formed in a welded structure tend to generate cracks that will result in damage. In this study, ATOS high-strength steel welding becomes important in butt welding where the tensile strength of the steel is over 80kg/$mm^2$. Structural discontinuities such as joints are more susceptible cracks in part due to their repeated loading and fatigue crack growth. The quality of parts produced depend or the shielded amounts of steel and on the skill of the welders in making strong welds. It is true that there are many factors that can be used to generate a lot of research in this area. However geometry and load conditions due to the combined effects with many issues could be solved through this study. Butt welding material at a plate thickness of 12t in ATOS 80 high-strength steel with a 4 pass, 20l/min, 24V/200A welder is good at making specimens with the quality shown in radiographic testing.

대퇴절단환자의 고관절 등속성근력비율에 관한 연구 (A Study on Isokinetic Strength Ratios of Hip joints in Above-knee Amputees)

  • 송창호;이완희
    • 대한물리치료과학회지
    • /
    • 제10권1호
    • /
    • pp.74-82
    • /
    • 2003
  • The purpose of this study is to provide guideline of muscle strengthening exercise for preparing ambulation by presenting suitable ratio of muscle power of agonist & antagonist, and that of concentric & eccentric contraction on behalf of amputee's normal ambulation training and it's strenthening as well. 7 Subjects who have femur amputee for experimental group were able to ambulate naturally without inconvenience and 20 adult subjects of comparison group for comparison were considered to be free from disturbance of ambulation. The method of study was to measure the muscle power of hip pint, was to figure out the ratio of agonist & antagonist, concentric contraction & eccentric contraction, and was to find out mean and standard deviation of each measurement. Every numerical value of comparison was tested by Mann-whitney and comparison group's comparison between left & right value was done with t-test. Results are as followings : 1) Extension force was stronger than flexor force and had no remarkable difference(p<0.05) 2) For normal adults, adduction farce was stronger than abduction force and for amputees, abduction force was stronger while adduction force was the same as the normal without showing remarkable difference(p<0.05) According the result above, I make an assumption that maintaining a proper ratio of muscle power on strengthening exercise for amputee's ambulation training & rehabilitation and finally bring out an improvement of transfer and ambulation.

  • PDF

The practice of blind bolting connections to structural hollow sections: A review

  • Barnett, T.C.;Tizani, W.;Nethercot, D.A.
    • Steel and Composite Structures
    • /
    • 제1권1호
    • /
    • pp.1-16
    • /
    • 2001
  • Due to aesthetic, economic, and structural performance, the use of structural hollow sections as columns in both continuous moment resisting and nominally pinned construction is attractive. Connecting the beams to these sections is somewhat problematic as there is no access to the interior of the section to allow for the tightening of a standard bolt. Therefore, bolts that may be tightened from one side, i.e., blind bolts, have been developed to facilitate the use of site bolting for this arrangement. This paper critically reviews available information concerning blind bolting technology, especially the performance of fasteners in shear, tension, and moment resisting connections. Also provided is an explanation of the way in which the results have been incorporated into design guidance covering the particular case of nominally pinned connections. For moment resisting connections, it is concluded that whilst the principle has been adequately demonstrated, sufficient data are currently not available to permit the provision of authoritative design guidance. In addition, inherent flexibilities in the connections mean that performance equivalent to full strength and rigid is unlikely to be achievable: a semicontinuous approach to frame design will therefore be necessary.

Damage state evaluation of experimental and simulated bolted joints using chaotic ultrasonic waves

  • Fasel, T.R.;Kennel, M.B.;Todd, M.D.;Clayton, E.H.;Park, G.
    • Smart Structures and Systems
    • /
    • 제5권4호
    • /
    • pp.329-344
    • /
    • 2009
  • Ultrasonic chaotic excitations combined with sensor prediction algorithms have shown the ability to identify incipient damage (loss of preload) in a bolted joint. In this study we examine a physical experiment on a single-bolt aluminum lap joint as well as a three-dimensional physics-based simulation designed to model the behavior of guided ultrasonic waves through a similarly configured joint. A multiple bolt frame structure is also experimentally examined. In the physical experiment each signal is imparted to the structure through a macro-fiber composite (MFC) patch on one side of the lap joint and sensed using an equivalent MFC patch on the opposite side of the joint. The model applies the waveform via direct nodal displacement and 'senses' the resulting displacement using an average of the nodal strain over an area equivalent to the MFC patch. A novel statistical classification feature is developed from information theory concepts of cross-prediction and interdependence. This damage detection algorithm is used to evaluate multiple damage levels and locations.

플라스틱 BGA 솔더접합부의 고신뢰성에 관한 연구 (A Study of the High Reliability in Plastic BGA Solder Joints)

  • 김경섭;신영의;이혁
    • Journal of Welding and Joining
    • /
    • 제17권3호
    • /
    • pp.90-95
    • /
    • 1999
  • The increase in high speed, multi-function and high I/O pin semiconductor devices highly demands high pin count, very thin, and high density packages. BGA is one of the solutions, but the package has demerits in package reliability, surface mounting problems due to the PCB warpage and solder joint crack related with TCE mismatch between the materials. On this study to verify the thermal fatigue lifetime of the solder joint FEM and experiments were performed after surface mounting BGA with different solder composition and reliability conditions. FEM showed optimum composition of Ag3.2-Sn96.5 and under the composition minimum creep deformation of the solder joint was calculated, and the thermal fatigue lifetime was improved. In view of temperature cycle condition, the conditions of $-65^{\circ}C$to $150^{\circ}C$ showed minimum lifetime and t was 1/3 of $0^{\circ}C$ to $125^{\circ}C$ condition. Test board was prepared and solder joint crack was verified. Until 1000cycle on soder joint crack was observed.

  • PDF

골프 드라이브스윙 시 힙의 수평면상 움직임에 관한 운동학적 분석 (Kinematic analysis of professional golfers hip joint motion on the horizontal plane during driver swinging)

  • 박영훈;염창홍;서국웅
    • 한국운동역학회지
    • /
    • 제15권4호
    • /
    • pp.97-104
    • /
    • 2005
  • Previous studies of kinematic analysis of golf swing usually dealt with variations vertically. The purpose of the study was to examine the horizontal hip joints motion of the fifteen male professional golfers during driver swinging. Kinematic variables were calculated by the Kwon3D motion analysis program. Paired t-tests and one-way ANOVA were used to compare the hip height, distance, displacement, and position differences. Results showed that there were no hip height changes and no hip height differences between left and right hip from address to impact. The axis of the backswing was braced right hip, the axis of the downswing was moving left hip. Hips position at the top of the backswing showed that hips move to target prior to hands, which means the sequential motion of the chain linked body segments. From address to impact, left hip moving distance was longer than right hip(p<.001), but during the whole swing, right hip moving distance was longer than left hip(p<.001). Hip rotation angle to target line was $-48.14{\pm}9.32^{\circ}$ at top of the backswing, $40.88{\pm}8.44^{\circ}$ at impact, and $104.70{\pm}8.14^{\circ}$ at finish.

만성관절염환자의 가족지지, 치료지시이행 및 삶의 만족간의 관계연구 (A Study on the Relationships between Family Support, Compliance and Life Satisfaction in Chronic Arthritis)

  • 최혜경
    • 대한간호학회지
    • /
    • 제17권3호
    • /
    • pp.218-226
    • /
    • 1987
  • This descriptive-correlational study was undertaken in order to examine if there were relationships between family support, compliance and life satisfaction in chronic arthritis patients. The sampling method was a non-probability, purposive sampling technique. The participants of this study were 92 volunteer adults. 1) who have been diagnosed as having chronic arthritis and 2) who were at the medical out patient clinic of one university hospital in Seoul between April 27th to May 12th 1987. The instruments used for this study were the Family Support Scale developed by Kang Hyun Sook, a Compilance Scale developed by the researcher and the Life-Satisfaction Index-Z developed by Wood et.al. Analysis of data was done using t-test, ANOVA, Pearson Correlation Coefficient and Stepwise Multiple Regression Analysis. The results of study were as follows; Hypothesis I; “The higher the family support, the higher the compliance” was accepted. (r=.2604, p<.01) Hypothesis II; “The higher the compliance, the higher the life satisfaction,” was rejected. (r=.1663, p>0.5) Hypothesis III; “The higher the family support, the higher the life satisfaction” was accepted. (r=.3914, p<.01) In addition, by using Stepwise Multiple Regression Analysis it was determined that the main influencing factors on the life satisfaction were family support, the number of inflammatory joints, compliance and pain level. These 4 main variables made it possible to explain 30.8% of the variance in life satisfaction. In conclusion, this study revealed that family support is an important factor that can improve compliance and life satisfaction in chronic arthritis patients.

  • PDF

Temporomandibular joint synovial chondromatosis accompanying temporal bone proliferation: A case report

  • Kim, Hak-Sun;Lee, Wonae;Choi, Jin-Woo;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • 제48권2호
    • /
    • pp.147-152
    • /
    • 2018
  • Synovial chondromatosis is a rare metaplastic disease affecting the joints, including the temporomandibular joint (TMJ). Since its symptoms are similar to those of temporomandibular disorders, a careful differential diagnosis is essential. A 50-year-old male patient was referred with the chief complaint of pain and radiopaque masses around the left TMJ on panoramic radiography. Clinically, pre-auricular swelling and resting pain was found, without limitation of mouth opening. On cone-beam computed tomographic images, multiple calcified nodules adjacent to the TMJ and bone proliferation with sclerosis at the articular fossa and eminence were found. T2-weighted magnetic resonance images showed multiple signal-void nodules with high signal effusion in the superior joint space and thickened cortical bone at the articular fossa and eminence. The calcified nodules were removed by surgical excision, but the hypertrophic articular fossa and eminence remained. A histopathological examination confirmed the diagnosis. The patient was followed up few months later without recurrence.

A STUDY OF THE EFFECT OF AN ANTI-ROTATIONAL INNER POST SCREW SYSTEMS ON ABUTMENT SCREW LOOSENING FOR SINGLE IMPLANT : PART 1

  • Choi, Sun-Young;Lee, Jai-Bong
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.345-353
    • /
    • 2007
  • Statement of problem. Implant abutment screw joints tend to loosen under clinical conditions. Abutment screw loosening results in loss of preload in function. Purpose. Anti-rotational inner post screw (ARIPS) systems were compared with conventional abutment screws to reduce screw loosening. Reverse torque values were evaluated. Material and methods. 32 implant assemblies (Warentec, Co, Ltd, Seoul, Korea) were organized as the 30-Ncm-torque conventional groups and 30-Ncm-torque ARIPS groups in external and internal system. The specimens were tested to 106 cycles at a load of 200N. Preload reverse torque, postload reverse torque, and the ratio of postload reverse torque to preload reverse torque were evaluated. The data were analyzed with unpaired t-test in external and internal systems. Results. In the ratio of postload reverse torque to preload reverse torque, the ARIPS groups showed significant differences than the conventional screw group in both external and internal system. Conclusion. Within the limitations of this study, abutment screw loosening was effectively reduced using ARIPS system.

Static behavior of steel tubular structures considering local joint flexibility

  • Wang, Yamin;Shao, Yongbo;Cao, Yifang
    • Steel and Composite Structures
    • /
    • 제24권4호
    • /
    • pp.425-439
    • /
    • 2017
  • As a thin-walled structure, local joint flexibility (LJF) in a tubular structure is prominent, and it may produce significant effect on the static performance for the overall structure. This study presents a simplified analytical model to analyze the static behavior for a steel tubular structure with LJF. The presented model simplifies a tubular structure into a frame model consisted of beam elements with considering the LJFs at the connections between any two elements. Theoretical equations of the simplified analytical model are deduced. Through comparison with 3-D finite element results of two typical planar tubular structures consisted of T- and Y-joints respectively, the presented method is proved to be accurate. Furthermore, the effect of LJF on the overall performance of the two tubular structures (including the deflection and the internal forces) is also investigated, and it is found from analyses of internal forces and deformation that a rigid connection assumption in a frame model by using beam elements in finite element analysis can provide unsafe and inaccurate estimation.