• Title/Summary/Keyword: T-Scan system

Search Result 171, Processing Time 0.026 seconds

An approach for real-time 3-dimensional shape measurement of human head

  • Ishimatu, T.;Ohata, T.;Usiroda, H.;Taguchi, N.;Matui, R.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.993-998
    • /
    • 1989
  • This paper describes a system which enables a fast 3-dimensional measuring of a human head using a slit-ray projection method . One feature of our system is that almost all calculations are executed using a look-up table, so that, forty thousands of sample point scan be processed in a few seconds. The feasibility of our system for practical applications is demonstrated measuring a human head.

  • PDF

OCCLUSION AND VERTICAL DIMENSION CHANGES ACCORDING TO DENTURE PROCESSING TECHNIQUES (총의치 온성방법에 따른 교합 및 수직 고경의 변화)

  • Kim, Mun-Young;Chung, Kwan-Ho;Yu, Hyoung-Woo;Ahn, Seung-Geun;Song, Kwang-Yeob;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.277-289
    • /
    • 1996
  • The purpose of this study was to compare the amount of the vertical pin opening of dentures processed by the conventional compression method & the injection-processing method. The articulating ribbon and T-Scan system were used to determine the changes in tooth contacts and the correlation between the changes in tooth contacts and the amount of the vertical pin opening after processing was analyzed statistically. The obtained results were as follows. 1. The amounts of the vertical pin opening were 0.75mm, 0.31mm for conventional compression method and injection-pressing method, respectively. The difference between the two methods was highly significant on the basis of t test statistics(p<0.05). 2. The total number of contact points recorded by articulating ribbon after processing was decreased to 48%, 72%, of that before processing for conventional compression method and injection-pressing method, by T-Scan system, 39%, 53%, respectively. 3. The mean values for the number of contacts points per tooth recorded by articulating ribbon after processing were 1.6 for the second molar, 2.2 for the first moalr, 0.4 for the second premolar, 0.6 for the first premolar in conventional compression method, and 2, 3.2, 1.2, 0.8 in injection-pressing method. 4. The correlation between the reduction of contact points and the amount of the pin opening after processing was not significant. 5. The mean values for the number of contact points per tooth recorded by T-Scan system after processing were 1.25, 1.4, 0.7, and 0.55 at the second molar, the first molar, the second premolar, and the first premolar in conventional compression method, and 1.45, 2.1, 1.0, 0.75 in injection method, respectively. 6. The correlation between the number of contact points by using articulating ribbon and T-Scan system after processing was not significant in both methods.

  • PDF

A STUDY ON THE CHANCES OF TOOTH CONTACTS FOLLOWING ORTHODONTIC TREATMENT BY USE OF THE T-SCAN SYSTEM (T-SCAN을 이용한 교정치료후의 교합접촉 변화에 관한 연구)

  • Jeong, Ki-Hoon;Kim, Jae-Duck;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.323-331
    • /
    • 1995
  • This study was undertaken to investigate the changes of tooth contacts following orthodontic treatment , using T-Scan system. Occlusal contacts in maximum intercuspation were examined in 26 patients at the end of the active phase of orthodontic treatment and again 3 months into the retention phase to abbess the initial posttreatment occlusal changes. The obtained results of this study were as follows : 1. The mean total number of contacts increased from 11.27 at the end of orthodontic treatment to 13.15 at the fellow up visit, which was found to be statistically significant (P<0.05). 2. The change of number of contacts on anterior teeth was unchanged. 3. The change of number of contacts on posterior teeth was found to be statistically significnat (P<0.01). 4. The change of fetal number of teeth in contact was significant (P<0.05). 5. The number of ant. teeth in contact was slightly increased. but Which was not found to be statistically significant (P>0.05). 6. The number of post. teeth in contact significantly increased, which was statistically significant (P<0.05). 7. A statistically significant relationship was found between the total number of contacts at the end of treatment and the change in the contacts over time. The fewer the number of tooth contact was at the end of orthodontic treatment, the greater number of tooth contact increased over time(r=-0.38, P<0.05).

  • PDF

A STUDY OF THE OCCLUSAL CONTACT PATTERN DURING MANDIBULAR MOVEMENTS OF ADULT WITH NORMAL OCCLUSION (T-scan을 이용한 성인정상교합자의 하악운동시 치아접촉양상에 관한 연구)

  • Chai Young-Ah;Park Nam-Soo;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.565-579
    • /
    • 1993
  • This study was accomplished to analyse and compare the occlusal contact patterns during eccentric mandibular movements in adult with normal occlusion. 50 subjects(male 27, female 23), who had natural occlusion and no symptom of temporomandibular disorder, were selected. Teeth contact patterns during mandibular eccentric movements were recorded and the distribution of tooth contacts in maximum intercuspation analysed by T-scan system. And then, tooth contact numbers recored by T-scan and silicone bite registration at centric occlusion were analysed and compared. The results obtained were as follows : 1. Antero-posteriorly, the qualitative center of occlusal contacts in centric occlusion were in the first molar areas, but there was a slight deviation in left-right directions. Thus, distribution of occlusal contacts were not bilaterally symmetric. 2. During the mandibular movements from centric occlusal position to right lateral and left lateral directions, the frequency that maxillary canine joined in lateral guidance was relatively high, but pure canine protected occlusion or pure group function occlusion had small frequency. 3. During mandibular protrusive movement, one or more maxillary central incisors frequently joined in protrusive guidance. 4. During mandibular eccentric movements, working and balancing side premature contact was observered in relatively high frequency. 5. In centric occlusal position, the numbers of occlusal contacts recorded on T-scan were relatively smaller than on silicone bite registration.

  • PDF

${T_2}weighted$- Half courier Echo Planar Imaging

  • 김치영;김휴정;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.57-65
    • /
    • 2001
  • Purpose : $T_2$-weighted half courier Echo Planar Imaging (T2HEPI) method is proposed to reduce measurement time of existing EPI by a factor of 2. In addition, high $T_2$ contrast is obtained for clinical applications. High resolution single-shot EPI images with $T_2$ contrast are obtained with $128{\times}128$ matrix size by the proposed method. Materials and methods : In order to reduce measurement time in EPI, half courier space is measured, and rest of half courier data is obtained by conjugate symmetric filling. Thus high resolution single shot EPI image with $128{\times}128$ matrix size is obtained with 64 echoes. By the arrangement of phase encoding gradients, high $T_2$ weighted images are obtained. The acquired data in k-space are shifted if there exists residual gradient field due to eddy current along phase encoding gradient, which results in a serious problem in the reconstructed image. The residual field is estimated by the correlation coefficient between the echo signal for dc and the corresponding reference data acquired during the pre-scan. Once the residual gradient field is properly estimated, it can be removed by the adjustment of initial phase encoding gradient field between $70^{\circ}$ and $180^{\circ}$ rf pulses. Results : The suggested T2EPl is implemented in a 1.0 Tela whole body MRI system. Experiments are done with the effective echo times of 72ms and 96ms with single shot acquisitions. High resolution($128{\times}128$) volunteer head images with high $T_2$ contrast are obtained in a single scan by the proposed method. Conclusion : Using the half courier technique, higher resolution EPI images are obtained with matrix size of $128{\times}128$ in a single scan. Furthermore $T_2$ contrast is controlled by the effective echo time. Since the suggested method can be implemented by software alone (pulse sequence and corresponding tuning and reconstruction algorithms) without addition of special hardware, it can be widely used in existing MRI systems.

  • PDF

OCCLUSAL ANALYSIS OF PATIENTS WITH TEMPOROMANDIBULAR DYSFUNCTION BY USE OF T-SCAN SYSTEM (T-Scan system을 이용한 측두하악 장애 환자의 교합 분석에 관한 연구)

  • Park Seon-Joo;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.3
    • /
    • pp.121-140
    • /
    • 1991
  • Fifteen dental college students of Chosun University without the abnormal occlusion, the history and symptom of temporomandibular dysfunction(TMD), and who had all permanent teeth except third molar and the fifteen moderate group and the fifteen severe group classified according to Helkimo's dysfunction index among patients on the basis of the symptom of TMD were selected. The occlusal contact, occlusal force and occlusal interference in eccentric movement was studied and analyzed using T-Scan system. The result were as follows : 1. The TLR centering around midsagittal axis was located at $1.42{\pm}0.82mm$ in control group, $3.36{\pm}1.45mm$ in severe group, and as TMD was heavier, occlusal contact was located at the farther point from midsagittal axis. 2. The PLR from the first contact to the fifth contact centering around midsagittal axis was located at $1.73{\pm}1.78mm$ in control group, $3.36{\pm}1.41mm$ in moderate group, and $5.39{\pm}4.32mm$ in severe group, and as TMD was heavier, occlusal contact was located at the farther point from midsgittal axis. 3. The TFB, PFB, RFB and LFB of occlusal contact centering around incisal axis had no significant difference statistically among control group, moderate group, and severe group, and it was located at first molar. 4.The LF and RF was smaller in TMD group than in control group. 5. The LR moment of occlusal force centering around midsagittal axis was located at $178.51{\pm}139.81N.mm$ in control group, $466.25{\pm}296.47N.mm$ in moderate group, and $749.18{\pm}588.18N.mm$ in severe group. And as TMD was heavier, it was located at the farther point from midsagittal axis. 6. The RL and LL of occlusal force centering around incisal axis had not-significance statistically among control group, moderate group, and severe group, and it was at the first molar. 7. The number of occlusal interference of the eccentric movement was increased in the patients of TMD.

  • PDF

Effects of NEX on SNR and Artifacts in Parallel MR Images Acquired using Reference Scan

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.422-427
    • /
    • 2013
  • The aim of this study was to investigate effects of the number of acquisitions (NEX) on signal-to-noise (SNR) and artifacts in SENSE parallel imaging of magnetic resonance imaging (MRI). 3.0T MR System, 8 Channel sensitivity encoding (SENSE) head coils were used along with an in-vivo phantom. Reference sequence of 3D fast field echo (FFE) was consisted of NEX values of 2, 4, 6, 8, 10 and 12. The T2 turbo spin echo (TSE) sequence used for exams achieved SENSE factors of 1.2, 1.5, 1.8, 2.0, 2.2, 2.5, 2.8, 3.0, 3.2, 3.5, 3.8 and 4.0. Exams were conducted five times for each SENSE factor to measure signal intensity of the object, the posterior phase-encode direction and frequency direction. And SNR was calculated using mean values. SENSE artifacts were identified as background signal intensity in the phase-encoded direction using MRIcro. It was found that SNR increased but SENSE artifacts reduced with NEX of 4, 8 and 12 when the NEX increased in reference scan. It is therefore concluded that image quality can be improved with NEX of 4, 8 and 12 for reference scanning.

A STUDY ON THE BITING FORCE OF ANTERIOR OPENBITE AND NORMAL OCCLUSION ADULTS (정상교합자와 전치부 개방교합자의 교합력에 관한 연구)

  • Kim, Dong-Ho;Lee, Dong-Joo
    • The korean journal of orthodontics
    • /
    • v.25 no.4
    • /
    • pp.487-495
    • /
    • 1995
  • This study was undertaken to compare each maximum biting force and to investigate its relationship with the facial skeketal form, number and position of tooth contact between anterior openbite and normal occlusion adults, using the T-scan system and the lateral cephalogram. The subjects of this study consisted of a group of 25 individuals with normal occlusion and another group of 14 with anterior openbite. The obtained results of this study were as follows : 1. The maximum biting force of anterior openbite adults was less than that of normal occlusion adults. 2. In anterior openbite adults, there were negative correlations between the maximum, biting force and SN/MP, FMA, PP/MP mesurement of lateral cephalogram. 3. In anterior openbite adults, as the mesial angulation of lower first molar against the occlusal plane increased, the more the biting force decreased. 4. In both groups, the greater the number of tooth contact, the more the biting force increased. 5. In both groups, the center of effort for anteroposterior occlusal contact was located on the first molar region.

  • PDF

A Functional Design of Programmable Logic Controller Based on Parallel Architecture (병렬 구조에 의한 가변 논리제어장치의 기능적 설계)

  • 이정훈;신현식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.8
    • /
    • pp.836-844
    • /
    • 1991
  • PLC(programmable logic controller) system is widely used for the control of factory. PLC system receives ladder diagram which is drawn by the user to implement hardware logic, converts the ladder diagram into sequence program which is executable in the PLC system, and executes the sequence program indefinitely unless user breaks. The sequence program processes the data of on/off signal, and endures 1 scan delay and missing of pulse-type signal shorter than a scan time. So, data dependency doesn't exist. By applying theis characteristics to multiprocessor architecture, we design parellel PLC functionally and evaluate performance upgrade. Parallel PLC consists of central processing module, N general processing unit, and a shared memory by master-slave type. Each module executes allocated sequence program by the control of central processing module. We can expect performance upgrade by parallel processing, and reliability by relocation of sequence program when error occurs in processing module.

  • PDF

Debugging of TTP(Train Tilting Processor) In Use The Embedded System (임베디드 시스템을 이용한 틸팅 제어 시스템(T.T.P)에 관한 연구)

  • Song, Yong-Soo;Shin, Seung-Kwon;Lee, Su-Gil;Han, Seong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2625-2627
    • /
    • 2004
  • Recently many technology of the T.T.P.(Train Tilting Processor) has been introduced for an efficient real-time operating system. but the problems of testing increasing complex digital integrated system continue to challenge the design and test community. Design main processor part that can be used on railroad synthesis control part by ARM CORE chip.

  • PDF