• Title/Summary/Keyword: T-Ray Imaging

Search Result 87, Processing Time 0.026 seconds

Terahertz Time Domain Spectroscopy, T-Ray Imaging and Wireless Data Transfer Technologies

  • Paek, Mun-Cheol;Kwak, Min-Hwan;Kang, Seung-Beom;Kim, Sung-Il;Ryu, Han-Cheol;Choi, Sang-Kuk;Jeong, Se-Young;Kang, Dae-Won;Jun, Dong-Suk;Kang, Kwang-Yong
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.3
    • /
    • pp.158-165
    • /
    • 2010
  • This study reviewed terahertz technologies of time domain spectroscopy, T-ray imaging, and high rate wireless data transfer. The main topics of the terahertz research area were investigation of materials and package modules for terahertz wave generation and detection, and setup of the terahertz system for time domain spectroscopy(TDS), T-ray imaging and sub-THz wireless communication. In addition to Poly-GaAs film as a photoconductive switching antenna material, a table-top scale for the THz-TDS/imaging system and terahertz continuous wave(CW) generation systems for sub-THz data transfer and narrow band T-ray imaging were designed. Dielectric properties of ferroelectric BSTO($Ba_xSr_{1-x}TiO_3$) films and chalcogenide glass systems were characterized with the THz-TDS system at the THz frequency range. Package modules for terahertz wave transmitter/receiver(Tx/Rx) photoconductive antenna were developed.

Digital X-Ray Technology and Applications (디지털 엑스선 기술과 응용)

  • Jeong, J.W.;Kang, J.T.;Kim, J.W.;Park, S.;Lee, M.L.;Song, Y.H.
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.5
    • /
    • pp.1-13
    • /
    • 2019
  • In modern times, X-ray imaging has become a necessary tool for early diagnosis, quality control, nondestructive testing, and security screening. X-ray imaging equipment generally comprises an X-ray generator and an image sensor. Most commercially available X-ray generators employ filament-thermionic electron-based X-ray tubes, thus demonstrating typical analog behavior, such as slow response and large stray X-rays. Furthermore, digital X-ray sources, which have been studied extensively using field electron emitters manufactured from nanometer-scale materials, provide fast and accurately controlled ultra-shot X-rays. This could usher in a new era of X-ray imaging in medical diagnosis and nondestructive inspections. Specifically, digital X-ray sources, with reduced X-ray dose, can significantly improve the temporal and spatial resolution of fluoroscopy and computed tomography. Recently, digital X-ray tube technologies based on carbon nanotubes, developed by Electronics and Telecommunications Research Institute, have been transferred to several companies and commercialized for dental imaging for the first time.

Coherent X-ray Diffraction Imaging with Single-pulse Table-top Soft X-ray Laser

  • Kang, Hyon-Chol;Kim, H.T.;Lee, S.K.;Kim, C.M.;Choi, I.W.;Yu, T.J.;Sung, J.H.;Hafz, N.;Jeong, T.M.;Kang, S.W.;Jin, Y.Y.;Noh, Y.C.;Ko, D.K.;Kim, S.S.;Marathe, S.;Kim, S.N.;Kim, C.;Noh, D.Y.;Lee, J.
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2008.02a
    • /
    • pp.429-430
    • /
    • 2008
  • We demonstrate coherent x-ray diffraction imaging using table-top x-ray laser at a wavelength of 13.9nm driven by 10-Hz ti:Sapphire laser system at the Advanced Photonics Research Institute in Korea. Since the flux of x-ray photons reaches as high as $10^9$ photons/pulse in a $20{\times}20{\mu}m^2$ field of view, we measured a ingle-pulse diffraction pattern of a micrometer-scale object with high dynamic range of diffraction intensities and successfully reconstructed to the image using phase retrieval algorithm with an oversampling ratio of 1:6. the imaging resolution is $^{\sim}150$ nm, while that is much improved by stacking the many diffraction patterns. This demonstration can be extended to the biological sample with the diffraction limited resolution.

  • PDF

Tc-99m hydroxymethylene diphosphonate scintigraphy, computed tomography, and magnetic resonance imaging of osteonecrosis in the mandible: Osteoradionecrosis versus medication-related osteonecrosis of the jaw

  • Ogura, Ichiro;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki;Kameta, Ayako;Hayama, Kazuhide
    • Imaging Science in Dentistry
    • /
    • v.49 no.1
    • /
    • pp.53-58
    • /
    • 2019
  • Purpose: To present characteristic findings of Tc-99m hydroxymethylene diphosphonate (HMDP) scintigraphy, computed tomography (CT), and magnetic resonance (MR) imaging for osteonecrosis in the mandible, especially osteoradionecrosis(ORN) and medication-related osteonecrosis of the jaw(MRONJ). Materials and Methods: Thirteen patients with MRONJ and 7 patients with ORN in the mandible underwent Tc-99m HMDP scintigraphy, CT, and MR imaging (T1-weighted images[T1WI], T2-weighted images[T2WI], short inversion time inversion recovery images[STIR]), diffusion-weighted images[DWI], and apparent diffusion coefficient [ADC] mapping). The associations of scintigraphy, CT, and MR imaging findings with MRONJ and ORN were analyzed using the chi-square test with the Pearson exact test. Results: Thirteen patients with MRONJ and 7 patients with ORN in the mandible showed low signal intensity on T1WI and ADC mapping, high signal intensity on STIR and DWI, and increased uptake on scintigraphy. Periosteal bone proliferation on CT was observed in 69.2% of patients with MRONJ(9 of 13) versus 14.3% of patients with ORN(1 of 7)(P=0.019). Conclusion: This study presented characteristic imaging findings of MRONJ and ORN on scintigraphy, CT, and MR imaging. Our results suggest that CT can be effective for detecting MRONJ and ORN.

Monte Carlo Studies on an Amorphous Silicon (a-Si:H) Digital X-Ray Imaging Device (무정형 실리콘(a-Si : H) 디지털 X-선 영상기기의 개발을 위한 Monte Carlo 컴퓨터 모의실험연구)

  • 이형구;신경섭
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.225-232
    • /
    • 1998
  • Results of Monte Carlo simulations on amorphous silicon based x-ray imaging arrays are described. In order to investigate the characteristics of amorphous silicon x-ray imaging devices and to provide the optimum design parameter, Monte Carlo simulations were performed. Monte Carlo simulation codes for our purpose were developed and various combinations of x-ray peak voltages, aluminum filter thicknesses, CsI(TI) thicknesses, and amorphous silicon photodiode pixel sizes were tested in connection with detection efficiency and spatial resolution of the amorphous silicon based x-ray imager. With usual Csl(TI) thickness of 300${\mu}{\textrm}{m}$-500${\mu}{\textrm}{m}$, detection efficiency was in the range of 70%-95% and energy absorption efficiency was in the range of 40%-70% for 60kVp-120kVp x-ray. From the simulations it was found that amorphous silicon pixel size and Csl(TI) thickness were the most important parameters which determine the resolution of the imager. By use of our simulation results we could provide proper combinations of Csl(TI) thicknesses and pixels sizes for optimum sensitivity and resolution.

  • PDF

An Experimental Study of Radiographic Density of Alveolar Bone and Cortical Thickness of Mandible by Osteoporosis (골다공증에 따른 치조골 방사선사진농도와 하악하연두께의 변화에 대한 연구)

  • Lee Byeong-Do
    • Imaging Science in Dentistry
    • /
    • v.30 no.4
    • /
    • pp.235-242
    • /
    • 2000
  • Purpose: To evaluate the effect of the systemic osteoporosis on radiographic density of alveolar bone and cortical thickness of mandible. Materials and Methods: The bone mineral density values of lumbar and femur were measured by dual-energy X-ray absorptiometry and T scores of lumbar, femur were obtained respectively. Radiographic densities of alveolar bones and panorama mandibular index (PMI, represents as cortical thickness) were analysed statistically according to age and T score variables. Results: The radiographic density of alveolar bone of maxillary molar showed significant difference by age and femur T group. That of mandibular molar showed significant difference between femur T group. Panorama mandibular index showed significant difference between age groups. Conclusion: The radiographic density of alvealar bones was more dependent on age and femur T than lumbar T. Cortical thickness of mandible was correlated with increasing age.

  • PDF

The Image Resolution Compare to Having Lead Plate or Not Lumbar Lateral Projection

  • Kim, Hyun-Soo;Min, Jung-Whan;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.145-151
    • /
    • 2011
  • The purpose of this study is to know some changes of resolution and image if we remove scattered ray using lead plate when doing lumbar lateral projection. Using 3 DR system(2 FD types, 1 CCD type) equipments and 2 film system equipments, we gain the image whether the phantom of abdomen equivalent sticking resolution chart has lead plate or not, whether we do collimation or not. Also, we use ion chamber, measure radiation exposure rate and change to entrance surface dose from it. we gain that images in the greatest condition of taking in clinic. 5 people in this group decoded resolution with our eyes, measured thickness of images and compared them from each equiments. Resolution has difference to size of collimation in DR FD type. Also there is no difference the original image with the new image which we abbreviated mAs. In DR CCD type, resolution didn't have difference whether lead plate is or not and whether we do collimation or not. In film type, existing or nonexisting of lead plate didn't influence on resolution. Lead plate makes the quality of image higher due to reducing scattered ray, it doesn't influence on resolution.

  • PDF

Ancient schwannoma in the parotid gland: A case report and review of the literature

  • Young-Eun Kwon
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.239-245
    • /
    • 2023
  • Schwannomas are uncommon neoplasms of neurologic origin that are rare in the salivary glands. A schwannoma that persists for a long time is referred to as an ancient schwannoma if it is accompanied by degenerative changes on histology. The case described herein involved a 37-year-old man with an ancient schwannoma that had persisted for 20 years in his right parotid gland. Clinically, the lesion presented with swelling and pain. Computed tomography revealed a well-defined, multilocular enhanced lesion. T2-weighted magnetic resonance images displayed multilocular hyperintensity, while T1-weighted images showed a high signal at the lobulated margin and a homogeneous low signal internally. The preoperative diagnosis, based on the lesion's location and imaging diagnosis, was Warthin's tumor. However, a biopsy conducted after surgical excision identified the lesion as a schwannoma with cystic degeneration. This report also presents a summary of the characteristics of rare cases of schwannoma in the major salivary gland based on this case and a literature review.

High Resolution Time Resolved Contrast Enhanced MR Angiography Using k-t FOCUSS (k-t FOCUSS 알고리듬을 이용한 고분해능 4-D MR 혈관 조영 영상 기법)

  • Jung, Hong;Kim, Eung-Yeop;Ye, Jong-Chul
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.10-20
    • /
    • 2010
  • Purpose : Recently, the Recon Challenge at the 2009 ISMRM workshop on Data Sampling and Image Reconstruction at Sedona, Arizona was held to evaluate feasibility of highly accelerated acquisition of time resolved contrast enhanced MR angiography. This paper provides the step-by-step description of the winning results of k-t FOCUSS in this competition. Materials and Methods : In previous works, we proved that k-t FOCUSS algorithm successfully solves the compressed sensing problem even for less sparse cardiac cine applications. Therefore, using k-t FOCUSS, very accurate time resolved contrast enhanced MR angiography can be reconstructed. Accelerated radial trajectory data were synthetized from X-ray cerebral angiography images and provided by the organizing committee, and radiologists double blindly evaluated each reconstruction result with respect to the ground-truth data. Results : The reconstructed results at various acceleration factors demonstrate that each components of compressed sensing, such as sparsifying transform and incoherent sampling patterns, etc can have profound effects on the final reconstruction results. Conclusion : From reconstructed results, we see that the compressed sensing dynamic MR imaging algorithm, k-t FOCUSS enables high resolution time resolved contrast enhanced MR angiography.