• Title/Summary/Keyword: T-CAD

Search Result 268, Processing Time 0.238 seconds

Post-Traumatic Stress Disorder Symptoms and Quality of Life of Patients with Coronary Artery Disease (관상동맥질환자의 외상 후 스트레스장애 증상과 삶의 질)

  • Lee, Seung Ah;Kang, Jiyeon
    • Journal of Korean Critical Care Nursing
    • /
    • v.12 no.1
    • /
    • pp.82-93
    • /
    • 2019
  • Purpose : The purpose of this study was to investigate the degree of post-traumatic stress disorder (PTSD) symptoms and the effect of PTSD on quality of life (QoL) among coronary artery disease (CAD) patients. Methods: The participants were 135 CAD patients who visited outpatient clinics in a university hospital in B city of Korea. Their PTSD symptoms and QoL were measured by structured questionnaires and analyzed with multiple hierarchical regression analysis. Results: Among the 135 participants, 20.7% were classified as moderate risk, and 3.7% as high risk for PTSD. PTSD symptoms were significantly higher in participants who were diagnosed with CAD within 6 months (t=26.02, p<.001). The physical component of health-related QoL was influenced by gender (${\beta}=-.25$, p =.003), recurrence of CAD (${\beta}=.21$, p =.008), and PTSD symptoms (${\beta}=-.33$, p <.001). The mental component of health-related QoL was influenced by religion (${\beta}=-.17$, p =.044), body mass index (${\beta}=.17$, p =.033), and PTSD symptoms (${\beta}=-.37$, p <.001). Conclusion: Patients who had had a CAD diagnosis for less than 6 months were found to be vulnerable to PTSD, and PTSD was found to have a negative impact on the physical and mental components of their QoL. It is necessary to develop an intervention program for the effective prevention and management of PTSD symptoms in patients with CAD.

Comparison of fracture strength, surface hardness, and color stain of conventionally fabricated, 3D printed, and CAD-CAM milled interim prosthodontic materials after thermocycling

  • Mesut Yildirim;Filiz Aykent;Mahmut Sertac Ozdogan
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.2
    • /
    • pp.115-125
    • /
    • 2024
  • PURPOSE. The purpose of this in vitro study was to investigate the fracture resistance, surface hardness, and color stain of 3D printed, CAD-CAM milled, and conventional interim materials. MATERIALS AND METHODS. A total of 80 specimens were fabricated from auto polymerizing polymethyl methacrylate (PMMA), bis-acryl composite resin, CAD-CAM polymethyl methacrylate resin (milled), and 3D printed composite resin (printed) (n = 20). Forty of them were crown-shaped, on which fracture strength test was performed (n = 10). The others were disc-shaped specimens (10 mm × 2 mm) and divided into two groups for surface hardness and color stainability tests before and after thermal cycling in coffee solution (n = 10). Color parameters were measured with a spectrophotometer before and after each storage period, and color differences (CIEDE2000 [DE00]) were calculated. The distribution of variables was measured with the Kolmogorov Smirnov test, and one-way analysis of variance (ANOVA), Tukey HSD, Kruskal-Wallis, Mann-Whitney U tests were used in the analysis of quantitative independent data. Paired sample t-test was used in the analysis of dependent quantitative data (P < .05). RESULTS. The highest crown fracture resistance values were determined for the 3D printed composite resin (P < .05), and the lowest were observed in the bis-acryl composite resin (P < .05). Before and after thermal cycling, increase in mean hardness values were observed only in 3D printed composite resin (P < .05) and the highest ΔE00 value were observed in PMMA resin for all materials (P < .05). CONCLUSION. 3D printing and CAD-CAM milled interim materials showed better fracture strength. After the coffee thermal cycle, the highest surface hardness value was again found in 3D printing and CAD-CAM milled interim samples and the color change of the bis-acryl resin-based samples and the additive production technique was higher than the PMMA resin and CAD-CAM milled resin samples.

The Development of Theoretical Model for Relaxation Mechanism of Sup erparamagnetic Nano Particles (초상자성 나노 입자의 자기이완 특성에 관한 이론적 연구)

  • 장용민;황문정
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.39-46
    • /
    • 2003
  • Purpose : To develop a theoretical model for magnetic relaxation behavior of the superparamagnetic nano-particle agent, which demonstrates multi-functionality such as liver- and lymp node-specificity. Based on the developed model, the computer simulation was performed to clarify the relationship between relaxation time and the applied magnetic field strength. Materials and Methods : The ultrasmall superparamagnetic iron oxide (USPIO) was encapsulated with biocompatiable polymer, to develop a relaxation model based on outsphere mechanism, which was resulting from diffusion and/or electron spin fluctuation. In addition, Brillouin function was introduced to describe the full magnetization by considering the fact that the low-field approximation, which was adapted in paramagnetic case, is no longer valid. The developed model describes therefore the T1 and T2 relaxation behavior of superparamagnetic iron oxide both in low-field and in high-field. Based on our model, the computer simulation was performed to test the relaxation behavior of superparamagnetic contrast agent over various magnetic fields using MathCad (MathCad, U.S.A.), a symbolic computation software. Results : For T1 and T2 magnetic relaxation characteristics of ultrasmall superparamagnetic iron oxide, the theoretical model showed that at low field (<1.0 Mhz), $\tau_{S1}(\tau_{S2}$, in case of T2), which is a correlation time in spectral density function, plays a major role. This suggests that realignment of nano-magnetic particles is most important at low magnetic field. On the other hand, at high field, $\tau$, which is another correlation time in spectral density function, plays a major role. Since $\tau$ is closely related to particle size, this suggests that the difference in R1 and R2 over particle sizes, at high field, is resulting not from the realignment of particles but from the particle size itself. Within normal body temperature region, the temperature dependence of T1 and T2 relaxation time showed that there is no change in T1 and T2 relaxation times at high field. Especially, T1 showed less temperature dependence compared to T2. Conclusion : We developed a theoretical model of r magnetic relaxation behavior of ultrasmall superparamagnetic iron oxide (USPIO), which was reported to show clinical multi-functionality by utilizing physical properties of nano-magnetic particle. In addition, based on the developed model, the computer simulation was performed to investigate the relationship between relaxation time of USPIO and the applied magnetic field strength.

  • PDF

Comparison of the Marginal and Internal Fit on the Cast and CAD-CAM Cores (주조에 의한 Core와 CAD-CAM에 의한 Core의 적합도 비교평가)

  • Han, Man-So;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.12 no.4
    • /
    • pp.368-374
    • /
    • 2012
  • Dental CAD (computer-aided design)/CAM (computer-aided manufacturing) systems facilitate the use of zirconia core for all-ceramic crown. The purpose of this study was to evaluate the marginal and internal fit of zirconia core fabricated using a dental CAD/CAM system and to compare the fit of metal cores by a conventional method. Ten identical cases of single coping study models (abutment of teeth 11) were manufactured and scanned. Ten zirconia cores were fabricated using dental CAD/CAM system. An experienced dental technician fabricated 10 samples of metal cores for the control group using the lost wax technique. Marginal and internal fit was measured by the silicone replica technique. Fit was measured with magnification of 160 using a digital Microscope. Margin, rounded chamfer, axial wall and incisal fits were measured for comparison. T-test of independent sample for statistical analysis was executed with SPSS 12.0 for Windows (SPSS Inc., Chicago, IL, USA) (${\alpha}$=0.05). The mean (SD) for marginal, rounded chamfer, axial wall and incisal were: $97.0\;(25.3){\mu}m$, $104.0\;(22.0){\mu}m$, $59.6\;(21.4){\mu}m$ and $124.8\;(33.3){\mu}m$ for the zirconia core group, and $785.2\;(18.4){\mu}m$, $83.8\;(15.1){\mu}m$, $42.7\;(9.6){\mu}m$ and $83.4\;(14.4){\mu}m$ for the metal core group. T-test showed significant differences between groups for margin (p<.001), rounded chamfer (p<.001), axial wall (p<.001) and incisal (p<.001). But zirconia core group observed that the marginal and internal fit values in the present study were within clinically acceptable range.

FREDHOLM-VOLTERRA INTEGRAL EQUATION WITH SINGULAR KERNEL

  • Darwish, M.A.
    • Journal of applied mathematics & informatics
    • /
    • v.6 no.1
    • /
    • pp.163-174
    • /
    • 1999
  • The purpose of this paper is to obtain the solution of Fredholm-Volterra integral equation with singular kernel in the space $L_2(-1, 1)\times C(0,T), 0 \leq t \leq T< \infty$, under certain conditions,. The numerical method is used to solve the Fredholm integral equation of the second kind with weak singular kernel using the Toeplitz matrices. Also the error estimate is computed and some numerical examples are computed using the MathCad package.

Coronary Artery Stenosis Quantification for Computed Tomography Angiography Based on Modified Student's t-Mixture Model

  • Sun, Qiaoyu;Yang, Guanyu;Shu, Huazhong;Shi, Daming
    • ETRI Journal
    • /
    • v.39 no.5
    • /
    • pp.662-671
    • /
    • 2017
  • Coronary artery disease (CAD) is a major cause of death in the world. As a non-invasive imaging modality, computed tomography angiography (CTA) is now usually used in clinical practice for CAD diagnosis. Precise quantification of coronary stenosis is of great interest for diagnosis and treatment planning. In this paper, a novel cluster method based on a Modified Student's t-Mixture Model is applied to separate the region of vessel lumen from other tissues. Then, the area of the vessel lumen in each slice is computed and the estimated value of it is fitted with a curve. Finally, the location and the level of the most stenoses are captured by comparing the calculated and fitted areas of the vessel. The proposed method has been applied to 17 clinical CTA datasets and the results have been compared with reference standard degrees of stenosis defined by an expert. The results of the experiment indicate that the proposed method can accurately quantify the stenosis of the coronary artery in CTA.

Mandibular reconstruction with a ready-made type and a custom-made type titanium mesh after mandibular resection in patients with oral cancer

  • Lee, Won-bum;Choi, Won-hyuk;Lee, Hyeong-geun;Choi, Na-rae;Hwang, Dae-seok;Kim, Uk-kyu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.35.1-35.7
    • /
    • 2018
  • Background: After the resection at the mandibular site involving oral cancer, free vascularized fibular graft, a type of vascularized autograft, is often used for the mandibular reconstruction. Titanium mesh (T-mesh) and particulate cancellous bone and marrow (PCBM), however, a type of non-vascularized autograft, can also be used for the reconstruction. With the T-mesh applied even in the chin and angle areas, an aesthetic contour with adequate strength and stable fixation can be achieved, and the pores of the mesh will allow the rapid revascularization of the bone graft site. Especially, this technique does not require microvascular training; as such, the surgery time can be shortened. This advantage allows older patients to undergo the reconstructive surgery. Case presentation: Reported in this article are two cases of mandibular reconstruction using the ready-made type and custom-made type T-mesh, respectively, after mandibular resection. We had operated double blind peer-review process. A 79-year-old female patient visited the authors' clinic with gingival swelling and pain on the left mandibular region. After wide excision and segmental mandibulectomy, a pectoralis major myocutaneous flap was used to cover the intraoral defect. Fourteen months postoperatively, reconstruction using a ready-made type T-mesh (Striker-Leibinger, Freibrug, Germany) and iliac PCBM was done to repair the mandible left body defect. Another 62-year-old female patient visited the authors' clinic with pain on the right mandibular region. After wide excision and segmental mandibulectomy on the mandibular squamous cell carcinoma (SCC), reconstruction was done with a reconstruction plate and a right fibula free flap. Sixteen months postoperatively, reconstruction using a custom-made type T-mesh and iliac PCBM was done to repair the mandibular defect after the failure of the fibula free flap. The CAD-CAM T-mesh was made prior to the operation. Conclusions: In both cases, sufficient new-bone formation was observed in terms of volume and strength. In the CAD-CAM custom-made type T-mesh case, especially, it was much easier to fix screws onto the adjacent mandible, and after the removal of the mesh, the appearance of both patients improved, and the neo-mandibular body showed adequate bony volume for implant or prosthetic restoration.

Lung/Heart Uptake Ratio and Transient Dilation Ratio of the Left Ventricle During Thallium-201 Imaging with Dipyridamole (Dipyridamole 부하를 T1-201 심근스캔에서 폐/심장 섭취율과 일과성 좌심실 확장율에 관한 연구)

  • Lee, Jae-Tae;Chung, Byung-Chun;Kim, Sang-Hyun;Lee, Kyu-Bo;Chae, Sung-Chull
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.177-185
    • /
    • 1991
  • Dipyridamole thallium imaging is one of the most widely accepted means of evaluating patients with suspected or known coronay artery disease. The results of thallium imaging help diagnose coronary artery disesse (CAD), determine the hemodynamic significance of coronary stenosis, evaluate viability of myocardium, assess the outcome of therapeutic interventions and stratify patients according to their risk for luther cardiac events. An increased lung thallium uptake and transient LV dilation has been reported as poor prognostic indicator and associated with extensive and severe coronary artery disease. We quantitated lung/heart uptake ratio (l/HUR) and transient left ventricular dilation ratio in 44 patients and 17 controls undertaking dipyridamole thallium-201 scintigraphy. The results are as follows: 1) The lung/heart uptake ratio was high in patients with CAD and which became higher according to increasing number of diseased vessel. The L/HUR of patients with low LVEF (<35%) was lower than those with normal LVEF. 2) Transient left ventricular dilation ratio of CAD patients had no close relation between numbers of diseased vessels and was not higher than normals. But transient left ventricular dilation ratio of patients with myocardial infartion was higher than normals. We concluded that lung/heart uptake ratio seems to be sensitive marker for severity of CAD and myocardial function, but transient left ventricular dilation ratio alone is not sufficient to be a marker for severe and extensive CAD.

  • PDF

Mechanical properties and 3D CAD Images of the Appearance of Cotton/Polyester Composite Yarn Knitted Fabric by Different Yarn Twisting Methods (연사방법에 따른 면/폴리에스테르 복합사 편성물의 역학적 특성 및 3D CAD System에 의한 외관특성)

  • Kim So-Jin;Jeon Dong-Won;Park Young-Hwan
    • Textile Coloration and Finishing
    • /
    • v.18 no.3 s.88
    • /
    • pp.49-58
    • /
    • 2006
  • The purpose of this study was to examine the effect of covering yarn's twist on mechanical properties of knitted fabrics of composite yarns with single covering process. Four yarns that were used in this study: two different composite yarns made from the four kinds of cotton and functional polyester-(Poly-A) with the ratio of 52:48, and the rest two yarns are the original cotton 100% yarn and the poly-A 100% yarn. The two kinds of composite yarns, CP1 and CP2, were processed on the single covering process. CP1 was applied on the single covering process with S-800 tpm, where Poly-A was used as covering yarn and cotton was used as core yarn. CP2 was applied on the same process as CP1 except that Poly-A had been applied on the two-for-one twisting process with S-400 tpm on the previous step. Sixteen mechanical properties of all the four knifed fabrics knitted under the same knitting conditions were measured by KES-FB system with the outer knit condition. And 3D CAD dressmaking simulations, which were driven by some of the mechanical properties, were presented. The results were as follows: CP2 had high RT values with twisting of covering yarn. CP2 also had high B, 2HB values because of higher linear density. SMD was affected rather by twisting of covering yarn than by fine hair of the cotton surface. Twisting of covering yarn made it decreasing T value and increasing W value. Dressmaking 3D CAD simulations showed that there are buckling effects on CP2 because of high bending rigidity and shear rigidity.

Evaluation of marginal and internal gap of wax coping fabricated by CAD/CAM system using intraoral scanner (구강 내 스캐너를 사용하여 CAD/CAM으로 제작된 왁스 코핑의 적합도 평가)

  • Kim, Dong-Yeon;Jung, Il-Do;Lee, Jae-Jun;Kim, Ji-Hwan;Kim, Myung-Bae;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.37 no.1
    • /
    • pp.1-7
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the marginal and internal gap of wax copings fabricated from extraoral scanning with intraoral scanning. Methods: Fifteen study models(abutment of teeth 16) were made by PMMA. STL files of thirty abutment were prepared by intraoral scanning with extraoral scanning. Wax copings of thirty fabricated using CAD/CAM system. Marginal and internal gap of wax copings of thirty were measured by silicone replica technique and digital microscope(${\times}140$). Date were analyzed by using independent samples t-test. Results: Mean (SD) of two group were measured $55.61(27.42){\mu}m$ for totally gap of ES group and $60.67(33.14){\mu}m$ for totally gap of IS group. But marginal and internal gap of two group were not differences statistically significant(p>0.05). Conclusion: Evaluation of marginal and internal gap of two group showed that no differences statistically significant and clinically acceptable results.