• Title/Summary/Keyword: T-2 weighted MRI

Search Result 366, Processing Time 0.025 seconds

Correlation between magnetic resonance imaging and cone-beam computed tomography for maxillary sinus graft assessment

  • Laurino, Fernando Antonio Reis;Choi, Isabela Goulart Gil;Kim, Jun Ho;Gialain, Ivan Onone;Ferraco, Renato;Haetinger, Rainer Guilherme;Pinhata-Baptista, Otavio Henrique;Abdala-Junior, Reinaldo;Costa, Claudio;Cortes, Arthur Rodriguez Gonzalez
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.93-98
    • /
    • 2020
  • Purpose: Little is known regarding the accuracy of clinical magnetic resonance imaging (MRI) protocols with acceptable scan times in sinus graft assessment. The aim of this study was to evaluate the correlations between MRI and cone-beam computed tomographic (CBCT) measurements of maxillary sinus grafts using 2 different clinical MRI imaging protocols. Materials and Methods: A total of 15 patients who underwent unilateral sinus lift surgery with biphasic calcium phosphate were included in this study. CBCT, T1-weighted MRI, and T2-weighted MRI scans were taken 6 months after sinus lift surgery. Linear measurements of the maximum height and buccolingual width in coronal images, as well as the maximum anteroposterior depth in sagittal images, were performed by 2 trained observers using CBCT and MRI Digital Imaging and Communication in Medicine files. Micro-computed tomography (micro-CT) was also performed to confirm the presence of bone tissue in the grafted area. Correlations between MRI and CBCT measurements were assessed with the Pearson test. Results: Significant correlations between CBCT and MRI were found for sinus graft height (T1-weighted, r=0.711 and P<0.05; T2-weighted, r=0.713 and P<0.05), buccolingual width (T1-weighted, r=0.892 and P<0.05; T2-weighted, r=0.956 and P<0.05), and anteroposterior depth (T1-weighted, r=0.731 and P<0.05; T2-weighted, r=0.873 and P<0.05). The presence of bone tissue in the grafted areas was confirmed via micro-CT. Conclusion: Both MRI pulse sequences tested can be used for sinus graft measurements, as strong correlations with CBCT were found. However, correlations between T2-weighted MRI and CBCT were slightly higher than those between T1-weighted MRI and CBCT.

THE RELATIVE SIGNAL INTENSITY OF RETRODISCAL TISSUE IN TMJ USING A T2-WEIGHTED MRI (MRI T2강조영상에서 측두하악관절 원판 후 조직의 상대적 신호 강도에 대한 연구)

  • Ye, Young-Geun;Lee, Sang-Hwa;Yoon, Hyun-Joong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.5
    • /
    • pp.457-462
    • /
    • 2005
  • The aim of this study is to evaluate the relative signal intensity of TMJ retrodiscal tissue in T2-weighted MRI as diagnostic marker of temporomandibular disorder(TMD). 58 temporomandibular joints from 29 TMD patients (14 men & 15 women) were evaluated. The relative signal intensity of retrodiscal tissue in T2-weighted MRI was referenced to brain gray matter same size of the region of interest(ROI). The collected data was compared to disc positions (normal, anterior disc displacement with reduction, anterior disc displacement without reduction), the presence of joint effusion. The relative signal intensity of retrodiscal tissue was significantly increased when the disc was displaced without reduction. And the relative signal intensity of retrodiscal tissue was significantly increased when joint effusion was present. The results suggest that evaluating the relative signal intensity of TMJ retrodiscal tissue using a T2-weighted MRI is valuable as a non-invasive tool for diagnosing the procession of TMD.

Imaging Studies in Mouse Brain Using Clinical 3T MRI Scanner (임상용 3T MRI를 이용한 마우스 뇌의 영상)

  • Lim, Soo-Mee;Park, Eun-Mi
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.348-353
    • /
    • 2010
  • The purpose of this study was to explore the potentials of a clinical 3T MRI in mouse brains and technical adaptation and optimization. T1-weighted images (T1WI), T2-weighted images (T2WI), FLAIR (Fluid Attenuated Inversion Recovery) images, Gadolinium enhanced T1-weighted images (Gd-T1WI), Diffusion weighted images (DWI) were acquired in brain of 2 mice (weight 20~25 g) with cerebral infarction by occlusion of right middle cerebral artery, 1 hour, 24 hours, 72 hours after infarction and 1 normal mouse brain using clinical 3T MRI scanner. We analyzed differentiation of striatum, ventricle, cerebral cortex, and possibility of detection of acute cerebral infarction. We could differentiate the striatum, ventricle, cerebral cortex on T2WI and on DWI, FLAIR, T1WI, the differentiation of each anatomy of brain was not definite, but acute cerebral infarction was detected on DWI of 1 hour, 24 hours, 72 hours after infarction and on T2WI, FLAIR of 24 hours, 72 hours after infarction. Clinical 3T MRI can be used in differentiation of anatomy of mouse brains and DWI can be helpul in detection of acute cerebral infarction in acute phase. With technical adaptation and optimization clinical 3T MRI can be useful tool for provide preclinical and clinical small animal studies.

Cerebral Infarction Model in Rat on Magnetic Resonance Imaging (흰 쥐의 뇌경색 병변에 대한 자기공명영상)

  • Jung, Ji-Sung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.55-58
    • /
    • 2011
  • It is important to study using experimental animals for research about stroke. Magnetic Resonance Imaging(MRI) is avaluable diagnosticmethods for stroke diagnosis. The purpose of this research is to know the Magnetic Resonance Imaging(MRI) and histopathological characteristics findings after induction of photothrombotic cerebral infarction in rat brain. Male Sprague-Dawley rats were anesthetized, Rose Bengal dye(20 mg/kg) was intravenously injected. The right sensonrimotor cortex of rat brain was exposed to cold light of 7 mm diameter at a position of 1 mm anterior and 3.5 mm lateral to bregma for 20 min. The post-infarction effects were monitored by T1 weighted and T2 weighted images of brain MRI. Histopathological changes were observed after Hematoxylin & Eosin staining. The lesion appeared clearly high signal intensity area on T2 weighted images(the major axis $7.04{\pm}0.11$ mm, the minor axis $3.08{\pm}0.04$ mm) and also H&E staining was same result. In conclusion, MRI was avaluable diagnostic methods for diagnosis and serial changes of stroke.

  • PDF

Optimal Flip Angle for T2-Weighted Effect in Micro 4.7T MRI SE Sequence (마이크로 4.7T MRI SE Sequence에서 T2강조효과를 위한 최적의 Flip Angle)

  • Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.2
    • /
    • pp.113-117
    • /
    • 2019
  • The purpose of this study was to investigate the FA value which can produce the best T2-weighted images by measuring the signal intensity and noise according to the FA value change in the brain image and the abdominal image of the mouse using micro-MRI. Brain imaging and abdominal imaging of BALB / C mice weighing 20g were performed using 4.7T (Bruker BioSpin MRI GmbH) micro-MRI equipment, Turbo RARE-T2 (spin echo-T2) images were scanned at TR 3500 msec and TE 36 msec. The changes of the FA values were $60^{\circ}$, $80^{\circ}$, $100^{\circ}$, $120^{\circ}$, $140^{\circ}$, $160^{\circ}$ and $180^{\circ}$. We measured signal intensity according to FA values of ventricle and thalamus in brain imaging, The signal intensity of kidney and muscle around the kidney was measured in abdominal images. To obtain SNR and CNR, we measured the background signals of two different parts, not the tissue. In the brain (thalamus) image, the signal intensity of FA $100^{\circ}$ was 7,433 and SNR (6.49) was the highest. In the abdominal (kidney) image, the signal intensity was highest at 16,523 when FA was $120^{\circ}$, and the highest SNR was 8.54 when FA was $140^{\circ}$. The CNR value of the brain image was 1.38 at FA $60^{\circ}$ and gradually increased to 8.29 at FA $180^{\circ}$. The CNR value of the muscle adjacent to the kidney gradually increased from 2.36 when the FA value was $60^{\circ}$ and the highest value was 4,57 at the FA value $180^{\circ}$.

The Value of Additional Cervicothoracic Spine Sagittal T2-weighted Images Included in Routine Lumbar Spine MR Imaging (요추 MR영상에 포함된 경흉추 시상T2강조영상의 효용성 평가)

  • Seo, Jiwoon;Park, So Young;Lee, Joon Woo;Lee, Guen Young;Kang, Heung Sik
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.91-100
    • /
    • 2013
  • Purpose : To evaluate the usefulness of cervicothoracic spine sagittal T2-weighted images (CT SAG T2WIs) included in routine lumbar spine MRI. Materials and Methods: Institutional review board approval was obtained and informed consents were waived for this retrospective study. The study group comprised 2,113 patients who underwent lumbar spine MRI from January 2005 to December 2005. CT SAG T2WIs were added in the routine lumbar spine MRIs. Radiologic reports were reviewed retrospectively for pathologic lesions on CT SAG T2WIs by one radiologist. Information of additional cervical or thoracic spine MRI and/or CT for further evaluation of positive findings on CT SAG T2WIs and their treatment were collected by retrospectively reviewing medical records. Results: The CT SAG T2WIs revealed 142 pathologic lesions in 139 (6.58%) of the 2,113 patients. They were easily obtained without positional change in a scan time of less than 2 minutes. Additional cervical or thoracic spine MRI and/or CT for positive findings on CT SAG T2WIs were performed in 13 patients. Seven patients underwent surgical treatment. Conclusion: CT SAG T2WIs included in routine lumbar spine MRI were useful in finding the pathologic lesions in cervicothoracic spine for the patients who assumed to have lesions in lumbar spine.

Pallidal Signal Intensities on T1-weighted MRI are Highly Observed in Advanced Liver Cirrhosis

  • Weon, Young-Cheol;Park, Neung-Hwa;Kim, Yang-Ho;Lee, Heun
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.5
    • /
    • pp.380-385
    • /
    • 2012
  • Background: Manganese (Mn) has been found to increase the signal intensity of the globus pallidus (GP) on T1-weighted magnetic resonance images (MRI). We performed this study in order to determine the features of liver disease that correlate with pallidal signal intensities. Methods: We assessed blood Mn levels and pallidal signals in T1-weighted MRI in 49 patients with liver cirrhosis and 23 healthy controls. Results: Increased signal intensity in the GP was observed in 30 of 49 (61.2%) patients with liver cirrhosis, with the pallidal index (PI) in patients with Child-Pugh classes B and C differing significantly from the PI in controls. Multiple linear regression analysis showed that blood Mn concentrations and Child-Pugh scores in cirrhotics were significantly associated with increased PI after controlling for other confounders (p<0.05 each). Conclusions: Pallidal signals on T1-weighted MRI are mainly observed in advanced liver cirrhosis. The present study suggests that advanced liver cirrhosis may be a human model for manganism.

Should We Recommend Ultrasonography for an Incidental Thyroid Nodule on Additional Cervicothoracic Sagittal T2-Weighted Image of Lumbar Spine MRI?

  • Cho, Hee Woo;Park, Jin-Oh;Lee, Young Han;Chung, Soo Yoon;Suh, Jin-Suck
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.4
    • /
    • pp.224-230
    • /
    • 2015
  • Purpose: To determine whether we should recommend ultrasonography (US) for an incidental thyroid nodule identified by additional cervicothoracic sagittal T2-weighted image (C-T sag T2WI) of lumbar spine magnetic resonance imaging (MRI). Materials and Methods: A retrospective study of 61 patients who underwent both lumbar spine MRI and thyroid US between December 2011 and April 2015 was conducted. For all US-found thyroid nodules > 1 cm, investigators evaluated whether there was any correlation between thyroid nodule detectability by C-T sag T2WI and US features such as echogenicity, composition, or suspicion of malignancy. Results: Solid hypoechoic (2/4; 50%) or mixed echoic nodules (4/8; 50%) appeared to be found relatively more easily by C-T sag T2WI than more benign-looking solid isoechoic (1/4; 25%) or spongiform nodules (0/6; 0%). Among six nodules with ultrasonographic suspicion for malignancy, only one nodule was detected by C-T sag T2WI. Conclusion: If an incidental thyroid nodule is seen by C-T sag T2WI, it would be better to recommend thyroid US for identifying malignancy.

Fluid Accumulation in Canine Tympanic Bulla: Radiography, CT and MRI Examinations

  • Lee, Young-Won;Kang, Sang-Kyu;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.25 no.3
    • /
    • pp.176-181
    • /
    • 2008
  • Fluid accumulation within the tympanic bulla is an important diagnostic indicator of canine otitis media although its identification can be a challenge using currently available imaging techniques. The purpose of this study was to compare radiography, computed tomography (CT) and magnetic resonance imaging (MRI) in the identification of fluid accumulation within canine tympanic bulla. Unilateral tympanic bulla in 10 beagles were experimentally filled with blood or saline. Quantitative analysis of CT images were obtained by using Hounsfield unit (HU). MR signal intensity was obtained by using region of interesting (ROI) and compared with those of gray matter. On the CT image, the presence of blood or saline produced a fluid opacity occupying the tympanic bulla. On the MR image, the appearance of blood in the tympanic bulla was isointense in T1-weighted images and hyperintense in T2-weighted images. However, the appearance of saline in the tympanic bulla was hypointense in T1-weighted images and hyperintense in T2-weighted images. This study suggest that CT and MR imaging are useful methods for detection and differentiation of fluid in canine tympanic bulla.

A RESEARCH FOR THE RELATIVE SIGNAL INTENSITY OF THE RETRODISCAL TISSUE IN THE TEMPOROMANDIBULAR JOINT DISORDER PATIENTS ON MRI (턱관절 질환환자의 MRI상 원판후 조직의 상대적 신호강도에 대한 연구)

  • Ha, Won-Suk;Yoon, Hyun-Joong;Lee, Sang-Hwa
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.3
    • /
    • pp.211-216
    • /
    • 2007
  • Temporomandibular joint disorders (TMD) often show muscular disorder, internal derangement and degenerative change of articular surface of the condyle. It is important to choose adequate diagnostic method for obtaining data for the diagnosis and treatment. Magnetic Resonance Imaging (MRI) has some advantages, because it shows good resolution image for the soft tissue and it is not invasive to the human body. We have performed serial research about the retrodiscal tissue of the TMJ according to the progress of the disease, using T2 weighted image, since 2002. In this study, we applicated resized observation area to compare signal intensity between the retrodiscal tissue of the TMJ and cerebral gray matter, using T2 weighted image.