• 제목/요약/키워드: T wave amplitude

검색결과 93건 처리시간 0.028초

YBCO SQUID를 이용한 실험쥐의 심자도 측정 (Rat Magnetocardiograms Measured by YBCO SQUID Magnetometer)

  • 안산;김인선;송종현
    • Progress in Superconductivity
    • /
    • 제12권2호
    • /
    • pp.124-128
    • /
    • 2011
  • We have developed a high-$T_C$ SQUID magnetometer system to measure magnetocardiograms of laboratory rats. White noise of the measurement system was about 50 fT/$Hz^{1/2}$ when measured in a magnetically shielded box. We optimized the measurement position to obtain clear MCG wave from rat's small heart by using grid measurements. With the optimization, the MCG signal was successfully detected with the peak amplitude of about 50 pT. We could observe well defined P-, QRS-, and T-wave from the rat MCG. The results suggest that the developed system has a strong potential to monitor the progress of heart disease model using laboratory rat.

Propagation of plane waves in an orthotropic magneto-thermodiffusive rotating half-space

  • Sheokand, Suresh Kumar;Kumar, Rajeshm;Kalkal, Kapil Kumar;Deswal, Sunita
    • Structural Engineering and Mechanics
    • /
    • 제72권4호
    • /
    • pp.455-468
    • /
    • 2019
  • The present article is aimed at studying the reflection phenomena of plane waves in a homogeneous, orthotropic, initially stressed magneto-thermoelastic rotating medium with diffusion. The enuciation is applied to generalized thermoelasticity based on Lord-Shulman theory. There exist four coupled waves, namely, quasi-longitudinal P-wave (qP), quasi-longitudinal thermal wave (qT), quasi-longitudinal mass diffusive wave (qMD) and quasi-transverse wave (qSV) in the medium. The amplitude and energy ratios for these reflected waves are derived and the numerical computations have been carried out with the help of MATLAB programming. The effects of rotation, initial stress, magnetic and diffusion parameters on the amplitude ratios are depicted graphically. The expressions of energy ratios have also been obtained in explicit form and are shown graphically as functions of angle of incidence. It has been verified that during reflection phenomena, the sum of energy ratios is equal to unity at each angle of incidence. Effect of anisotropy is also depicted on velocities of various reflected waves.

점근 근사법에 의한 파랑변위 계산 (Computation of Free Surface Displacement for Water Waves by Asymptotic Approximations)

  • 서승남
    • 한국해안해양공학회지
    • /
    • 제6권1호
    • /
    • pp.12-22
    • /
    • 1994
  • 외력에 의해 생성된 일정 수심 위를 전파하는 파랑변위의 시간변화를 점근 근사법을 사용하여 분석하였다. Stationary Phase 방법, Steepest Descents 방법 그리고 선두파랑 근사법을 사용하였다. 1차원 파랑과 2차원 파랑의 해면변위에 대한 근사법을 검증하기 위해 근사식과 수치적분으로 계산한 변위를 도시하였다. 파고 감소율에 대한 기존의 결과인 1차원 선두파랑의 감소율은 t$^{-1}$3/, 후속파랑은 t$^{-1}$2 그리고 2차원 후속파낭은 t$^{-1}$로 이들 근사식의 타당함을 입증하였다. 그러나 2차원 선두파랑의 감소율은 기존 Kajiura의 결과인 t$^{-4}$ 3/과 다른 t$^{-5}$6/이 적합함을 나타내었다.

  • PDF

쇄파 발생에 관한 실험적 연구 (An Experimental Study on Breaking Waves)

  • 이동연;주성문;최항순
    • 한국해안해양공학회지
    • /
    • 제8권1호
    • /
    • pp.37-43
    • /
    • 1996
  • 본 논문에서는 2차원 수조의 임의 지점에서 쇄파를 만드는 실험방법에 대하여 논하였다. 쇄파를 만들기 위해서 임의의 지점에 각 성분의 파정이 모이도록 위상차를 갖는 선형파를 합성하여 조파기를 작동시켰다. 또한 조파판의 운동진폭을 조절하여 다양한 파기울기에 대하여 실험을 수행하였다. 실험 결과 운동진폭이 너무 작은 경우에는 쇄파현상이 일어나지 않았고 불규칙한 파형만이 나타났으며, 최대파고가 H=0.0113g/T$^2$ 이상이어야 쇄파 현상이 나타남을 확인하였다. 쇄파의 모양은 대부분 경우에 spilling 형태였고, 특정한 운동진폭일 때 plunging 형태의 쇄파를 관찰할 수 있었다. 한편 비점성, 비압축성 유체로 가정하여 얻어진 경계적분방정식을 고차경계요소로 이산화하여 수치계산을 수행하였다. 자유표면의 처리를 위해서 Mixed Euler-Lagrangian 기법을 이용하였다 수치결과는 자유표면에서 주파수간의 상호간섭의 영향을 제대로 반영하고 있으며, 실험에서 계측한 파형을 제대로 모사하고 있음을 확인할 수 있었다.

  • PDF

Iterative Fourier Transform Algorithm Based on the Segmentation of Target Image for a High-Speed Binary Spatial Light Modulator

  • Im, Yeonsu;Kim, Hwi;Hahn, Joonku
    • Journal of the Optical Society of Korea
    • /
    • 제19권2호
    • /
    • pp.149-153
    • /
    • 2015
  • A digital micro-mirror device (DMD) has the potential to modulate an incident wave with high speed, and the application for holographic display has been studied by many researchers. However, the quality of reconstructed image isn't good in comparison with that from a gray-scale amplitude-only hologram since it is a binary amplitude-only spatial light modulator (SLM). In this paper, we suggest a method generating a set of binary holograms to improve the quality of the reconstructed image. Here, we are concerned with the case for which the object plane is positioned at the Fourier domain of the plane of the SLM. In this case, any point in the Fourier plane is related to all points in the hologram. So there is a chance to generate a set of binary holograms illuminated by incident wave with constant optical power. Moreover, we find an interesting fact that the quality of reconstructed image is improved when the spatial frequency bandwidth of the binary hologram is limited. Therefore, we propose an iterative segmentation algorithm generating a set of binary holograms that are designed to be illuminated by the wave with constant optical power. The feasibility of our method is experimentally confirmed with a DMD.

Helmholtz 공명기 내부를 전파하는 비정상 충격파의 수치해석 (Numerical Simulations of an Unsteady Shock Wave Propagating into a Helmholtz Resonator)

  • 이영기;권용훈;신현동;김희동;청목준지
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1643-1648
    • /
    • 2004
  • When a shock wave propagates into a Helmholtz resonator, very complicated wave phenomena are formed both inside and outside the resonator tube. Shock wave reflection, shock focusing phenomena and shock-vortex interactions cause strong pressure fluctuations inside the resonator, consequently leading to powerful sound emission. In the present study, the wave phenomena inside and outside the Helmholtz resonator are, in detail, investigated with a help of CFD. The Mach number of the incident shock wave is varied below 2.0 and several types of resonators are tested to investigate the influence of resonator geometry on the wave phenomena. A TVD scheme is employed to solve the axisymmetric, compressible, Euler equations. The results obtained show that the configuration of the Helmholtz resonator significantly affects the peak pressure of shock wave focusing, its location, the amplitude of the discharged wave and resonance frequency.

  • PDF

정상적(正常的)인 한우(韓牛)의 심전도(心電圖)에 관(關)한 연구(硏究) I. 표준지유도(標準肢誘導) (Studies on electrocardiogram of the normal Korean native cattle I. Standard limb leads)

  • 최인혁;정인성;김남수;서두석
    • 대한수의학회지
    • /
    • 제33권4호
    • /
    • pp.719-734
    • /
    • 1993
  • The electrocardiographic(ECG) parameters on the standard limb leads in the normal Korean native cattle have been measured with a 3 channel Electrocardiograph built in a computed analysis. The study was conducted on the animals 98 heads of mean age of 17.7 months. Conduction parameters, waves, intervals and segments have been recorded. The recordings were analyzed as to shape and amplitude of the P and T waves and the components of the QRS complex. Heart rate was recorded by the Electrocardiogram which were a mean of $80.4{\pm}11.6beats/min$. And the younger had a higher heart rate than the older one. Average conduction times in the RP, the QRS complex and the QTc interval recorded $166.7{\pm}23.1msec.$, $79.7{\pm}8.8msec.$ and $395.5{\pm}30.4msec.$, in the P and T wave duration recorded $70.1{\pm}13.5msec.$ and $97.6{\pm}16.9msec.$, and in the PR and ST segment duration recorded $97.9{\pm}23.5msec.$ and $173.9{\pm}40.3msec.$, respectively. The wave forms in each lead observed various types. The amplitudes of wave type showed the highest frequency in each lead that were analyzed as follow : 1. In P wave, amplitudes of the positive type showed the frequency of 65.3%, 82.7% and 52.0% in leads I, II and III that were $103.1{\pm}47.8{\mu}V$, $115.2{\pm}37.3{\mu}V$ and $67.4{\pm}26.9{\mu}V$, and it showed the frequency of 54.1% and 85.7% in the leads aVL and aVF that were $63.7{\pm}23.0{\mu}V$, $88.0{\pm}83.6{\mu}V$, respectively. Average amplitude of the negative type showed the frequency of 78.6% in lead aVR which was $99.3{\pm}38.0{\mu}V$. 2. Average amplitude of the QRS complex were from $362.8{\pm}177.7{\mu}V$ to $532.8{\pm}253.9{\mu}V$(mean of $449.1{\pm}57.2{\mu}V$) that in all leads except lead I were manifested the Low-Voltage QRS complex(below 0.5mV). Average amplitudes of each wave type in the QRS complex aere $-50.2.4{\pm}258.2{\mu}V$ and $-428.6{\pm}195.1{\mu}V$ in the QS groups type that showed a frequency of 66.3%, 70.4% in the leads I and aVL, were $451.1{\pm}20.4.0{\mu}V$, $387.6{\pm}175.8{\mu}V$ and $299.3{\pm}146.5{\mu}V$ in the R groups type that showed a frequency of 48.0%, 53.1% and 34.7% in the leads III, aVR and aVF, and were $-307.5{\pm}180.3{\mu}V$, $201.4{\pm}77.2{\mu}V$ in the QR wave type which showed a frequency of 39.8% in lead II, respectively. 3. In T wave, amplitude of the positive type showed the frequency of 50.0%, 82.7%, 51.0% and 57.1% in leads II, III aVR and aVF which were $214.9{\pm}115.6{\mu}V$, $188.5{\pm}119.3{\mu}V$, $191.0{\pm}93.7{\mu}V$ and $165.7{\pm}91.9{\mu}V$, and the negative type showed a frequecny of 66.3% and 72.5% in leads I and aVL. that were $221.3{\pm}112.5{\mu}V$, $-173.6{\pm}86.7{\mu}V$, respectively. 4. Amplitude of ST segment in leads I, II and III were a mean of $-12.2{\pm}37.2{\mu}V$, $17.5{\pm}42.6{\mu}V$ and $28.3{\pm}40.4{\mu}V$, in leads aVR, aVL and aVF were $-3.9{\pm}32.5{\mu}V$, $-15.9{\pm}35.6{\mu}V$ and $26.2{\pm}37.5{\mu}V$, respectively.

  • PDF

Submerged Horizontal and Vertical Membrane Wave Barrier

  • Kee S.T.
    • 한국해양공학회지
    • /
    • 제19권2호
    • /
    • pp.1-11
    • /
    • 2005
  • In the present paper, the hydrodynamic properties of a Rahmen type flexible porous breakwater with dual fixed pontoon system interacting with obliquely or normally incident small amplitude waves are numerically investigated. This system is composed of dual vertical porous membranes hinged at the side edges of dual fixed pontoons, and a submerged horizontal membrane that both ends are hinged at the steel frames mounted pontoons. The dual vertical membranes are extended downward and hinged at bottom steal frame fixed into seabed. The wave blocking and dissipation mechanism and its effects of permeability, Rahmen type membrane and pontoon geometry, pretensions on membranes, relative dimensionless wave number, and incident wave headings are thoroughly examined.

A split spectrum processing of noise-contaminated wave signals for damage identification

  • Miao, X.T.;Ye, Lin;Li, F.C.;Sun, X.W.;Peng, H.K.;Lu, Ye;Meng, Guang
    • Smart Structures and Systems
    • /
    • 제10권3호
    • /
    • pp.253-269
    • /
    • 2012
  • A split spectrum processing (SSP) method is proposed to accurately determine the time-of-flight (ToF) of damage-scattered waves by comparing the instantaneous amplitude variation degree (IAVD) of a wave signal captured from a damage case with that from the benchmark. The fundamental symmetrical ($S_0$) mode in aluminum plates without and with a notch is assessed. The efficiency of the proposed SSP method and Hilbert transform in determining the ToF of damage-scattered $S_0$ mode is evaluated for damage identification when the wave signals are severely contaminated by noise. Broadband noise can overwhelm damage-scattered wave signals in the time domain, and the Hilbert transform is only competent for determining the ToF of damage-scattered $S_0$ mode in a noise-free condition. However, the calibrated IAVD of the captured wave signal is minimally affected by noise, and the proposed SSP method is capable of determining the ToF of damage-scattered $S_0$ mode accurately even though the captured wave signal is severely contaminated by broadband noise, leading to the successful identification of damage (within an error on the order of the damage size) using a triangulation algorithm.

정중운동신경과 척골운동신경의 전기생리학적 연구 (An Electrophysiologic Study on the Median Motor Nerve and Ulnar Motor Nerve)

  • 김종순;이현옥;안소윤;구봉오;남건우;김영직;김호봉;류재관;류재문
    • 대한정형도수물리치료학회지
    • /
    • 제11권2호
    • /
    • pp.62-70
    • /
    • 2005
  • The determination of peripheral nerve conduction velocity is an important part to electrodiagnosis. Its value as neurophysiologic investigative procedure has been known for many years but normal value of median and ulnar motor nerve was poorly reported in Korea. To evaluate of median and ulnar motor nerve terminal latency, amplitude of CMAP(compound muscle action potential), conduction velocity and F-wave latency for obtain clinically useful reference value. 71 normal volunteers(age, 19-65 years; 142 hands) examined who has no history of peripheral neuropathy, diabetic mellitus, chronic renal failure, endocrine disorders, anti-cancer medicine, anti-tubercle medicine, alcoholism, trauma, radiculopathy. Nicolet Viking II was use for detected terminal latency, amplitude of CMAP, conduction velocity and F-wave latency of median and ulnar motor nerve. Data analysis was performed using SPSS. Descriptive analysis was used for obtain mean and standard deviation, independent t-test was used to compare between Rt and Lt side also compare between different in genders. The results are summarized as follows: 1. Median motor nerve terminal latency was right 3.00ms, left 2.99ms and there was no significantly differences between right and left side and genders. 2. Median motor nerve amplitude of CMAP was right 17.26mV, left 1750mV and there was no significantly differences between right and left side and genders. 3. Median motor nerve conduction velocity was right 57.89m/sec, left 58.03m/sec and there was no significantly differences between right and left side and genders. 4. Median motor nerve F-wave latency was right 25.74ms, left 25.59ms and there was significantly differences between genders. 5. Ulnar motor nerve terminal latency was right 2.38ms, left 2.45ms and there was significantly differences between right and left side. 6. Ulnar motor nerve amplitude of CMAP was right 15.99mV, left 16.02mV and there was no significantly differences between right and left side and genders. 7. Ulnar motor nerve conduction velocity was right 60.35m/sec, left 59.73m/sec and there was no significantly differences between right and left side and genders. 8. Ulnar motor nerve F-wave latency was right 25.53ms, left 25.57ms and there was significantly differences between genders.

  • PDF