• Title/Summary/Keyword: T detector

검색결과 431건 처리시간 0.028초

Crop-row Detection by Color Line Sensor

  • Ha, S.ta;T.Kobaysahi;K.Sakai
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.353-362
    • /
    • 1993
  • The purpose of this study is to develop a crop-row detector which can be applied to an automatic row following control for cultivators or thinning machines. In this report, a possibility of new crop-row detecting method was discussed. This detecting method consists of two principal means. One is the hardware means to convert the two dimensional crop-row vision to the compacted one dimensional information. The conversion is achieved by a color line sensor and a rotating mirror. In order to extract crop-row , R and G signals of RGB color system are used. The locations of two different points on the target row are detected by this means. Another is the software means to estimate the offset value and the heading angle between the detector and the target row which can be assumed as a straight line. As a result of discussion, it was concluded that this detecting method would be accurate enough for practical use.

  • PDF

Determination of Mequitazine in Human Plasma by Gas-Chro-matography/Mass Spectrometry with Ion-Trap Detector and Its Pharmacokinetics after Oral Administration to Volunteers

  • Kwon Oh-Seung;Kim Hye-Jung;Pyo Heesoo;Chung Suk-Jae;Chung Youn Bok
    • Archives of Pharmacal Research
    • /
    • 제28권10호
    • /
    • pp.1190-1195
    • /
    • 2005
  • The objective of this study was to develop an assay for mequitazine (MQZ) for the study of the bioavailability of the drug in human subjects. Using one mL of human plasma, the pH of the sample was adjusted and MQZ in the aqueous phase extracted with hexane; the organic layer was then evaporated to dryness, reconstituted and an aliquot introduced to a gas chromatograph/mass spectrometer (GC/MS) system with ion-trap detector. Inter- and intra-day precision of the assay were less than 15.1 and $17.7{\%}$, respectively; Inter- and intra-day accuracy were less than 8.91 and $18.6{\%}$, respectively. The limit of quantification for the current assay was set at 1 ng/mL. To determine whether the current assay is applicable in a pharmacokinetic study for MQZ in human, oral formulation containing 10 mg MQZ was administered to healthy male subjects and blood samples collected. The current assay was able to quantify MQZ levels in most of the samples. The maximum concentration ($C_{max}$ was 8.5 ng/mL, which was obtained at 10.1 h, with mean half-life of approximately 45.5 h. Under the current sampling protocol, the ratio of $AUC_{t{\rightarrow}last}$ to $AUC_{t{\rightarrow}{\infty}}$ was $934{\%}$, indicating that the blood collection time of 216 h is reasonable for MQZ. Therefore, these observations indicate that an assay for MQZ in human plasma is developed by using GC/MS with ion-trap detector and validated for the study of pharmacokinetics of single oral dose of 10 mg MQZ, and that the current study design for the bioavailability study is adequate for the drug.

인공 면역계를 기반으로 하는 적응형 침입탐지 알고리즘 (Adaptive Intrusion Detection Algorithm based on Artificial Immune System)

  • 심귀보;양재원
    • 한국지능시스템학회논문지
    • /
    • 제13권2호
    • /
    • pp.169-174
    • /
    • 2003
  • 인터넷 보급의 확산과 전자상거래의 활성화 그리고 유ㆍ무선 인터넷의 보급에 따른 악의적인 사이버 공격의 시도가 점점 증가하고 있다. 이로 인해 점차 더 많은 문제가 야기될 것으로 예상된다. 현재 일반적인 인터넷상의 시스템은 악의적인 공격에 적절하게 대응해오지 못하고 있으며, 다른 범용의 시스템들도 기존의 백신 프로그램에 의존하며 그 공격에 대응해오고 있다. 따라서 새로운 침입에 대하여는 대처하기 힘든 단점을 가지고 있다. 본 논문에서는 생체 자율분산시스템의 일부분인 T세포의 positive selection과 negative selection을 이용한 자기/비자기 인식 알고리즘을 제안한다 제안한 알고리즘은 네트워크 환경에서 침입탐지 시스템에 적용하여 기존에 알려진 침입뿐만 아니라 새로운 침입에 대해서도 대처할 수 있다.

Neutronic design of pulsed neutron facility (PNF) for PGNAA studies of biological samples

  • Oh, Kyuhak
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.262-268
    • /
    • 2022
  • This paper introduces a novel concept of the pulsed neutron facility (PNF) for maximizing the production of the thermal neutrons and its application to medical use based on prompt gamma neutron activation analysis (PGNAA) using Monte Carlo simulations. The PNF consists of a compact D-T neutron generator, a graphite pile, and a detection system using Cadmium telluride (CdTe) detector arrays. The configuration of fuel pins in the graphite monolith and the design and materials for the moderating layer were studied to optimize the thermal neutron yields. Biological samples - normal and cancerous breast tissues - including chlorine, a trace element, were used to investigate the sensitivity of the characteristic γ-rays by neutron-trace material interactions and the detector responses of multiple particles. Around 90 % of neutrons emitted from a deuterium-tritium (D-T) neutron generator thermalized as they passed through the graphite stockpile. The thermal neutrons captured the chlorines in the samples, then the characteristic γ-rays with specific energy levels of 6.12, 7.80 and 8.58 MeV were emitted. Since the concentration of chlorine in the cancerous tissue is twice that in the normal tissue, the count ratio of the characteristic g-rays of the cancerous tissue over the normal tissue is approximately 2.

IoT Enabled Smart Emergency LED Exit Sign controller Design using Arduino

  • Jung, Joonseok;Kwon, Jongman;Mfitumukiza, Joseph;Jung, Soonho;Lee, Minwoo;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • 제6권1호
    • /
    • pp.76-81
    • /
    • 2017
  • This paper presents a low cost and flexible IoT enabled smart LED controller using Arduino that is used for emergency exit signs. The Internet of Things (IoT) is become a global network that put together physical objects using network communications for the purpose of inter-communication of devices, access information on internet, interaction with users as well as permanent connected environment. A crucial point in this paper, is underlined on the potential key points of applying the Arduino platform as low cost, easy to use microcontroller with combination of various sensors applied in IoT technology to facilitate and establishment of intelligent products. To demonstrate the feasibility and effectiveness of the system, devices such as LED strip, combination of various sensors, Arduino, power plug and ZigBee module have been integrated to setup smart emergency exit sign system. The general concept of the proposed system design discussed in this paper is all about the combination of various sensor such as smoke detector sensor, humidity, temperature sensor, glass break sensors as well as camera sensor that are connected to the main controller (Arduino) for the purpose of communicating with LED exit signs displayer and dedicated PC monitors from integrated system monitoring (controller room) through gateway devices using Zig bee module. A critical appraisal of the approach in the area concludes the paper.

Low Rate VLC Receiver Design Using NCP302 Voltage Detector for IoT/IoL Connected Smart Homes

  • Lee, Beomhee;Mariappan, Vinayagam;Khudaybergenov, Timur;Han, Jungdo;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • 제7권4호
    • /
    • pp.50-56
    • /
    • 2018
  • The Internet of Things (IoT) and Visible Light Communication (VLC) is opening up new services in lighting industry by integrating sensory network features in addition to standard illumination functionality. In this progressive developments, the next generation lighting devices for smart homes are capable to sense the environmental conditions and transfer the captured data through lights to gateway controller to access remotely. The smart home environmental sensor information's are few kbps only so VLC systems need to built-in with low rate light connectivity to transfer data to the gateway. To provide error free communication, the quality of a received light signal is important to be considered when designing an VLC receiver. Therefore, this paper proposes the design of robust low rate IoL receiver design using NCP302 voltage detector for micro controller to adapt the IoT/IoL front end module for system integration. To evaluate the proposed system performance, the Arduino UNO based IoT/IoL controller designed with lighting, sensors and lights connectivity interfaces. The experimental result shows that the robust interference rejection is feasible on proposed VOL receiver and possible to have an error-free communication up to 10 kbps at a low SNR using OOK modulation.

디지털흉부X선촬영에서 검출기 방식에 따른 최적의 노출조건 (Optimal Exposure Conditions according to Detector Type in Chest Digital Radiography)

  • 이원정
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.213-221
    • /
    • 2015
  • The aim of this study was to set up the optimal exposure condition according to detector type considering image quality (IQ) with radiation dose in chest digital radiography. We used three detector type such as flat-panel detector (FP) and computed radiography (CR), and charge-coupled device (CCD). Entrance surface dose (ESD) was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image informations. Standard exposure condition using each institution was 117 kVp-AEC at FP and 117 kVp-8 mAs at CR, and 117 kVp-8 mAs at CCD. Statistical analysis was performed by One way ANOVA (Dunnett T3 test) using SPSS ver. 19.0. In FP, IQ scores were not significant difference between 102 kVp-4 mAs and 117 kVp-AEC (28.4 vs. 31.1, p=1.000), even though ESD was decreased up to 50% ($62.3{\mu}Gy$ vs. $125.1{\mu}Gy$). In CR, ESD was greatly decreased from 117 kVp-8 mAs to 90 kVp-8 mAs without significant difference of IQ score (p=1.000, 24.6 vs. 19.5). In CCD, IQ score of 117 kVp-8 mAs was similar with 109 kVp-8 mAs (29.6 vs. 29.0), with decreasing from $320.8{\mu}Gy$ to $284.7{\mu}Gy$ (about 11%). We conclude that optimal x-ray exposure condition for chest digital radiography is 102 kVp-4 mAs in FP and 90 kVp-8 mAs in CR, and 109 kVp-8 mAs in CCD.

Mechanical design of mounts for IGRINS focal plane array

  • Oh, Jae Sok;Park, Chan;Cha, Sang-Mok;Yuk, In-Soo;Park, Kwijong;Kim, Kang-Min;Chun, Moo-Young;Ko, Kyeongyeon;Oh, Heeyoung;Jeong, Ueejeong;Nah, Jakyuong;Lee, Hanshin;Pavel, Michael;Jaffe, Daniel T.
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.53.2-53.2
    • /
    • 2014
  • IGRINS, the Immersion GRating INfrared Spectrometer, is a near-infrared wide-band high-resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. IGRINS employs three HAWAII-2RG focal plane array (FPA) detectors. The mechanical mounts for these detectors serves a critical function in the overall instrument design: Optically, they permit the only positional compensation in the otherwise "build to print" design. Thermally, they permit setting and control of the detector operating temperature independently of the cryostat bench. We present the design and fabrication of the mechanical mount as a single module. The detector mount includes the array housing, a housing for the SIDECAR ASIC, a field flattener lens holder, and a support base. The detector and ASIC housing will be kept at 65 K and the support base at 130 K. G10 supports thermally isolate the detector and ASIC housing from the support base. The field flattening lens holder attaches directly to the FPA array housing and holds the lens with a six-point kinematic mount. Fine adjustment features permit changes in axial position and in yaw and pitch angles. We optimized the structural stability and thermal characteristics of the mount design using computer-aided 3D modeling and finite element analysis. Based on the computer simulation, the designed detector mount meets the optical and thermal requirements very well.

  • PDF