• Title/Summary/Keyword: T/T probe

Search Result 427, Processing Time 0.025 seconds

Development of Micro-size Search Coil Magnetometer for Magnetic Field Distribution Measurement

  • Ka, E.M.;Son, De-Rac
    • Journal of Magnetics
    • /
    • v.13 no.1
    • /
    • pp.34-36
    • /
    • 2008
  • For the measurement of the magnetic field distribution with high spatial resolution and high accuracy, the magnetic field sensing probe must be non-magnetic, but the MFM probe and sub-millimeter-meter size Hall probe use a ferromagnetic tip and block, respectively, to increase the sensitivity. To overcome this drawback, we developed a micro-size search coil magnetometer which consists of a single turn search coil, Terfenol-D actuator, scanning system, and control software. To reduce the noise generated by the stray ac magnetic field of the actuator driving coil, we employed an even function $\lambda$-H magnetostriction curve and lock-in technique. Using the developed magnetometer, we were able to measure the magnetic field distribution with a magnetic field resolution of 1 mT and spatial resolution of $0.1mm{\times}0.2mm$ at a coil vibration frequency of 1.8 kHz.

Experimental Analysis of Radiative Heat Interchange on Furnace Exit Plane of a Steam Boiler

  • Ahn, Kook-Young;Antonovsky, Vjacheslav-Ivanovich
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.239-247
    • /
    • 2001
  • Measured radiative heat fluxes on the furnace exit plane of a heavy duty power boiler of steam output 1650 T/h are discussed. A high-ash pulverized bituminous coal was used. Such measurements are necessary to improve heat fluxes inside a steam boiler furnace was manufactured. An extra small heat radiation sensor was placed in the water cooled head of the probe. The sensor had no direct contact with furnace gases and measured only the radiant energy. There was no exposure to convective heat transfer. With the radiometric probe, one can obtain a spherical indicatrix of radiation intensity as well as hemispherical radiative heat flux incident on any surface passing through a measuring point inside the furnace. Thus, the quantity of radiation energy, passing through the furnace exit plane, to the convective heating surfaces and the quantity of radiation energy going in the opposite direction were measured. A formula for relative radiative heat flux on the furnace exit plane has been proposed.

  • PDF

A Study on Eddy-current Probe with Ferrite Cores over a Layered Half-Space (레이어가 있는 하프스페이스에서 페라이트코아가 있는 와류탐침에 대한 연구)

  • Kim, T.W.;Byun, K.R.;Choi, J.H.;Kang, E.S.;Hwang, H.J.
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.613-616
    • /
    • 1998
  • In this paper, a model of a Eddy-current probe coil with a ferrite core in the presence of a half-space with a layer is developed. The half-space with a layer is accounted for by computing the appropriate Green's function by using Bessel transforms. Upon introducing equivalent Amperian currents within a core to explain effect to a impedance change in the coil due to a (ferrite) core, we derive a volume integral equation, The integral equation is transformed via the method of moments into a vector-matrix equation, which is then solved using a linear equation solver. Through the above processing, we computed impedance value in a Eddy-current probe coil due to a conductivity change of layer.

  • PDF

Direct radio-iodination of folic acid for targeting folate receptor-positive tumors

  • Huynh, Phuong Tu;Lee, Woonghee;Ha, Yeong Su;Yoo, Jeongsoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.4 no.1
    • /
    • pp.3-10
    • /
    • 2018
  • The folate receptor (FR) is a promising cell membrane-associated target for nuclear imaging of various cancers (via imaging $FR-{\alpha}$) and potentially also inflammatory diseases (via imaging $FR-{\beta}$), through the use of folic acid-based radioconjugates. However, there have been several drawbacks of previously reported radioconjugates, such as a short half-life of the radiolabel ($^{68}Ga\;t_{1/2}$ 68 min), a complex and time-consuming multistep radiosynthesis, and a high renal uptake of radiolabeled folate derivatives. The goal of this study was to develop an imaging probe by directly labeling folate with radioactive iodine without using an extra prosthetic group. The radiolabeling of folate was optimized using various labeling conditions and the labeled tracers were isolated by high-performance liquid chromatography. The in vitro stability of labeled folate was checked in phosphate-buffered saline and serum. The tumor-targeting efficacy of the probe was also evaluated by biodistribution studies using a murine 4T1 tumor model.

A Study on the Self-Aligned Cobalt Silicidation and the Formation of a Shallow Junction by Concurrent Junction Process (동시 접합 공정에 의한 자기정렬 코발트 실리사이트 및 얇은 접합 형성에 관한 연구)

  • 이석운;민경익;주승기
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.2
    • /
    • pp.68-76
    • /
    • 1992
  • Concurrent Junction process (simultaneous formation of a silicide and a junction on the implanted substrate) by Rapid Thermal Annealig has been investigated. Electrical and material properties of CoSi$_2$ films were analyzed with Alpha Step, 4-point probe, X-ray diffraction(XRD) and Scanning Electron Microscope(SEM). And CoSi$_2$ junctions were examined with Spreading Resistance probe in order to see the redistribution of electrically activated dopants and determined the junction depth. Two step annealing process, which was 80$0^{\circ}C$ for 30sec and 100$0^{\circ}C$ for 30sec in NS12T ambient was employed to form CoSi$_2$ and shallow junctions. Resistivity of CoSi$_2$ was turned out to be 11-15${\mu}$cm and shallow junctions less than 0.1$\mu$m were successfully formed by the process. It was found that the dopant concentration at CoSi$_2$/Si interface increased as decreasing the thickness of Co films in case of $p^{+}/n$ and $n^{+}/p$ junctions while the junction depth decreased as increasing CoSiS12T thickness in case of $p^{+}/n$ junction.

  • PDF

A Study on the New Vulnerability of Inducing Service Charge Doctoring SSID of Smartphone Based on Android (안드로이드폰 SSID 변조를 통한 새로운 과금 유발 취약점에 관한 연구)

  • Heo, Geon-Il;Yoo, Hong-Ryul;Park, Chan-Uk;Park, Won-Hyung
    • Convergence Security Journal
    • /
    • v.10 no.4
    • /
    • pp.21-30
    • /
    • 2010
  • Wireless network is one of the 2010's most important security issues. As smartphone is popularize, the number of Wireless Internet users is really growing and wireless AP spring up everywhere. But most wireless AP haven't being managed properly in terms of security, Wireless Internet users also don't recognize important of security. This situation causes grave security threats. This paper design and analyze a new cyber attack whose it circulates malware via QR code and activates Mobile AP to induce service charge. The new vulnerability we suggest forces to activate Mobile AP of smartphone based on Android and responds to all Probe Request are generated around, and brings induction of service charge and communication problems in its train.

INDUCTION PLASMA DEPOSITION TECHNOLOGY FOR NUCLEAR FUEL FABRICATION

  • I. H. Jung;K. K. Bae;Lee, J. W.;Kim, T. K.;M. S. Yang
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.216-221
    • /
    • 1998
  • A study on induction plasma deposition with ceramic materials, yttria-stabilized-zirconia ZrO$_2$-Y$_2$O$_3$ (m.p 264O $^{\circ}C$), was conducted with a view developing a new method for nuclear fuel fabrication Before making dense pellets more than 96%TD., the spraying condition was optimized through the process parameters, such as chamber pressure, plasma plate power powder spraying distance, sheath gas composition, probe position, particle size and powders different morphology. The results with a 5mm thick deposit on rectangular planar graphite substrates showed a 97.11% theoretical density when the sheath gas flow rate was Ar/H$_2$120/20 l/min, probe position 8cm, particle size -75 ${\mu}{\textrm}{m}$ and spraying distance 22cm by AMDRY146 powder. The degree of influence of the main effects on density were powder morphology. particle size, sheath gas composition, plate power and spraying distance, in that order. Among the two parameter interactions, the sheath gas composition and chamber pressure affects density greatly. By using the multi-pellets mold wheel type, the pellet density did not exceed 94%T.D., owing to the spraying angle.

  • PDF

Analysis of Chromosome aberrations by fluorescence in situ hybridization using triple chromosome-specific probes in human lymphocyte exposed to radiation (3중 DNA probe를 이용한 FISH(fluorescence in situ hybridization) 기법으로 방사선에 의한 염색체 이상 분석)

  • Chung, Hai-Won;Kim, Su-Young;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.1
    • /
    • pp.45-53
    • /
    • 1999
  • Fluorescence in situ hybridization with chromosome-specific probe has been shown to be a valid and rapid method for detection of chromosome rearrangements induced by radiation. This method is useful for quantifying structural aberrations, expecially for stable ones, such as translocation and insertion, which are difficult to detect with conventional method in human lymphocyte. In order to apply FISH method for high dose biological dosimetry, chromosomal abberations by radiation at doses of 1, 3, 5, and 7Gy were analysed with whole chromosome-specific probes by human chromosome 1, 2 and 4 according to PAINT system. The frequencies of stable translocation per cell equivalent were 0.04, 0.33, 1.22, 2.62, and 5.58 for the lymphocyte exposed to 0, 1, 3, 5, and 7Gy, respectively, and those of dicentric were 0.00, 0.06, 0.52, 1.19 and 2.44, respectively. Significantly more translocation of t(Ab), a translocated chromosome with a piece of painted acentric matrial 'b' attached to unpainted piece containing centromere 'A', than reciprocal chromosome t(Ba) was observed. The frequencies of all type of chromosome rearrangements increased with dose. From above result, FISH seemed to be useful for radiation biodosimetry by which the frequencies of various types of stable aberrations in human lymphocyte can be observed more easily than by conventional method and so will improve our ability to perform meaningful biodosimetry.

  • PDF

Construction and analysis of painting probe for homogeneously staining regions in human neuroblastoma cell line IMR-32

  • Park, Sun-Hwa;Kim, Ho-Chung;Chun, Yong-Hyuck
    • Journal of Genetic Medicine
    • /
    • v.1 no.1
    • /
    • pp.45-50
    • /
    • 1997
  • Neuroblastoma, a pediatric malignant neoplasm of neural crest origin, has a wide range of clinical virulence. The mechanisms contributing to the development of neuroblastomas are largely unclear, but non-random chromosomal changes identified over the past years suggest the involvement of genetic alterations. Amplification of the human N-myc proto-oncogene is frequently seen either in extrachromosomal double minutes or in homogeneously staining regions (HSRs) of aggressively growing neuroblastomas. N-myc maps to chromosome 2 band 24, but HSR have never been observed at this band, suggesting transposition of N-myc during amplification. We have constructed and analyzed the region-specific painting probe for HSR in neuroblastoma IMR-32 to determine the derivative chromosomes. Microdissection was performed on HSR using an inverted microscope with the help of microglass needles and an micromanipulator. We pretreated the microdissected fragments with Topoisomerase I which catalyzes the relaxation of supercolled DNA, and performed two initial rounds of DNA synthesis with T7 DNA polymerase followed by conventional PCR to enable the reliable preparation of Fluorescent in situ hybridization probe from a single microdissected chromosome. With this method, it was possible to construct the region-specific painting probe for HSR. The probe hybridized specifically to the HSRs of IMR-32, and to 2p24, 2p13 of normal chromosome. Our results suggest there was coamplification of N-myc together with DNA of the chromosome 2p24 and 2p13. Moreover, the fluorescent signals for the amplified chromosomal regions in IMR-32 cells were also easily recognized at a Thus this painting probe can be applied to detect the similar amplification of N-myc in neuroblastoma tissue, and the probe pool for HSR may be used to identify the cancer-relevant genes.

  • PDF

Effective Thermal Conductivity of Rice Starch (쌀전분의 열전도도)

  • Yoon, Jung-Ro
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.1-5
    • /
    • 1994
  • Effective thermal conductivity of rice starch was measured by the probe method. The thermal conductivity increased from $0.065{\sim}0.09\;W/mK$ to $0.13{\sim}0.23\;W/mK$ as the moisture content increased from 0 to 28.2%. At constant bulk density, the temperature effect on the thermal conductivity was positive and getting larger as the moisture content increased. In the moisture range $7.2{\sim}33.6%$, a very weak peak was found at $65^{\circ}C$ in DSC thermogram. Positive effect of interaction between temperature and moisture content on the thermal conductivity was thought to be due to the increase of thermal conductivity of water with temperature, not to starch gelatinization phenomenon. A regression equation $(r^{2}=0.963)$, Ke=-0.111+0.000203 T+0.00173 M.C.+0.000247 $P_{b}+0.000035$ M.C. T, was obtained in the range of moisture content (M.C.) of $0{\sim}28.2%$ (w.b.), temperature (T) of $25{\sim}70^{\circ}C$ and the bulk density $(P_{b})$ of $650{\sim}800\;kg/m^{3}$

  • PDF