• Title/Summary/Keyword: T/C ratio

Search Result 1,781, Processing Time 0.031 seconds

An Experimental Study on the Performance Characteristics of the Vortex Tube for Substitution of the Intercooler in a Common-rail Diesel Engine (커먼레일 디젤기관의 인터쿨러 대체용 볼텍스 튜브 장치의 성능특성에 관한 실험 연구)

  • Im, Seok-Yeon;Choi, Doo-Seuk;Ryu, Jeong-In
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.3
    • /
    • pp.172-178
    • /
    • 2008
  • An object of this study is to confirm performance characteristics of the vortex tube apparatus for substitution of the intercooler in a common-rail diesel engine. The turbo pressure, the intake air flow rate and the ${\Delta}T_c$ decrease ratio of the intercooler were measured in a experimental engine. The vortex tube apparatus was made after confirmation of the geometric phenomena in fundamental experiments. To investigate energy separation characteristics of the vortex tube, the measured turbo pressure was applied to the vortex tube inlet and the ${\Delta}T_c$ decrease ratio was compared with one of the intercooler in the cold air mass flow ratio similar to the intake air flow rate of the experimental engine. From the results, we found that the energy separation ratio is increased according to of the inlet pressure and the ${\Delta}T_c$ decrease ratio of the vortex tube apparatus is higher than one of the intercooler at low engine speed and engine load of medium and low.

Nitrogen Removal Characteristics in Two-Sludge System of SBR Type Using Sewage Wastewater of Low C/N Ratio (낮은 C/N 비에서 운영되는 SBR 유형의 Two-Sludge 공정의 질소 제거 특성)

  • Ryu, Hong-Duck;Kim, Hak-In;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.7-14
    • /
    • 2006
  • In this study, nitrogen removal characteristics of SBR3 process, which is two-sludge system of sequencing batch reactor(SBR) type, were investigated, with comparison of those of SBR1 process, which is conventional SBR process, and SBR2 process, which was designed to enhance denitrification efficiency through step-feeding of wastewater, using domestic wastewater. SBR3 process of two-sludge type can perform external nitrification, on which nitrification occurs in separated reactor, and enhanced denitrification using biosorbed organics. In the results with domestic wastewater, T-N removal efficiency of SBR3 process was better than those of SBR1 and SBR2 processes. It was observed that bigger difference of T-N removal efficiency between SBR3 process and SBR1 & SBR2 processes was showed at low C/N ratio than that at high C/N ratio resulting from more efficient use of organics by biosorption mechanism in denitrification of SBR3 process than those of SBR1 and SBR2 processes. In addition, T-N removal efficiency of SBR3 process according to influent T-N loading rate was better than those of SBR1 and SBR2, even though influent T-N loading rate of SBR3 process was higher than that of SBR1 and SBR2 process resulting from operation of SBR3 process in short hydraulic retention time(HRT) by external nitrification.

Effects of C/N Ratio on Removal of Organic Matter and Nitrogen in Alternately Intermittently Aerated Nonwoven Fabric Filter Bioreactor (교대로 간헐 포기되는 부직포 여과막 생물반응조에서 C/N비가 유기물 및 질소 제거효율에 미치는 영향)

  • Ahn, Yun-Chan;Bae, Min-Su;Lee, Jong-Ho;Cho, Yun-Kyung;Cho, Kwang-Myeung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.5
    • /
    • pp.499-506
    • /
    • 2005
  • This study was performed to investigate the effects of influent C/N ratio on the removal of organic and nitrogenous compounds by two nonwoven fabric filter bioreactors. The reactors were alternately aerated at an aeration/nonaeration period ratio of 60 min/60 min, and fed with wastewater only during nonaeration period. The influent C/N ratio (COD/TKN) was gradually reduced from 10 to 2. The influent was prepared by diluting the leachate from a foodwaste treatment facility in I city so that the COD concentration could be about 2,500 mg/L. The C/N ratio of the wastewater was adjusted by adding ammonium chloride. The results of the experiment showed that the COD and BOD concentration of the effluent was $40{\sim}54\;mg/L$ and $1{\sim}4\;mg/L$, respectively at the C/N ratios of $10{\sim}3$, and the effluent SS concentration was always below 2.0 mg/L. The T-N removal efficiencies were 96% or higher at C/N ratios of $10{\sim}5$, but decreased to 83% and 81%, respectively at the C/N ratios of 3 and 2.8. At the C/N ratios of 2.6 and 2, the effluent quality deteriorated due to ammonia toxicity. The fraction of nitrifying microorganism in the reactors increased from 10% to 20% as the C/N ratio decreased from 5 to 2.6. Alkalinity consumed were $3.12{\sim}3.49\;g$ alkalinity/g T-N removed at the C/N ratios of $10{\sim}5$, which are lower than the theoretical value of 3.57. However, the ratio increased to 4.63 and 4.87 g alkalinity/g T-N removed, respectively at the C/N ratios of 3 and 2.8.

Effect of Operational Parameters on the Ammonia Stripping (암모니아 스트리핑에 미치는 운전인자의 영향)

  • Seo, Jeong-Beom;An, Kwang-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.9
    • /
    • pp.935-939
    • /
    • 2006
  • The biological nutrient removal from domestic wastewater with low C/N ratio is difficult. Therefore, this study was performed to examine effect of operational parameters such as air supply, hydraulic retention time, pH on the nitrogen removal by ammonia stripping and to increase influent C/N ratio without required carbon source. The ammonia stripping system used for the bench-scale experiment in laboratory had a dimension of 15 cm diameter and 150 cm height. The ammonia stripping reactors were classified into two types, type AS I and type AS II, according to there using or not media. Results of the research showed that the T-N removal efficiency of AS I using plastic media is slightly higher than AS II without media. In experimental condition of air supply 30 L/min and pH 12.5, T-N removal efficiencies increased as HRT of ammonia stripping reactor became longer from 8 hr to 36 hr. In experimental condition of HRT 36 hr, it was also found that the T-N removal efficiencies improved through increase of air supply. On the other hand, C/N ratio of wastewater was increased from average 3.9 to 5.4 by ammonia stripping.

ON THE CATCH OF GILL NET IN THE JEJU ISLAND -Comparison of mackerel catch in monofilament and multifilament gill nets- (제주도 자망이망율에 관하여 -고등어 자망의 이망율 비교-)

  • SHON Tae Jun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.8 no.1
    • /
    • pp.7-10
    • /
    • 1975
  • The catches of mackerel by monofilament and multifilament net were compared by means of $x^2$ and t-test method. In order to improve the netting twine of drift nets, 6 shoots 5 different mesh and nylon-monofilament netting twines $(B\times2,\;C\;D,\;F,)$ and 2 shoe nylon-multifilament $(A\times2)$ which are using near the Jeju Island in contemporary days were used for the experiment. These gill no were connected in order of A, ,B, C, A, B, E, F and operated fly fishing boat Taeann Ho (7T) near sea of Jeju Ialand from May 1974 to August 1974. The results obtained are as follows: 1. B type nylon-monofilament gill nets were superior to nylon-multifilament gill nets in catch according to the result of $X^2$ test and t-test, and the catch ratio was $M_A:\;M_B=1:1.8$. 2. 75mm mesh size C, D nylon-monofilament gill nets were superior to 85mm mesh size nylonmonofilament gill nets, and their catch ratio were E, F: C, D=1:2.8. 3. The catch ratio C, D and E, F type nets were compared by means of t-teat, however could not recognized their relationship.

  • PDF

Mechanism of Soil Remediation in Contaminated Area Using Vertical Drains (연직배수재(VDs)에 의한 오염지반정화 메커니즘 연구)

  • Lee Haeng Woo;Chang Pyoung Wuck;Kang Byung Yoon;Kim Hyun Tae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.5
    • /
    • pp.63-71
    • /
    • 2005
  • In-situ soil remediation mechanism through the vertical drains (VDs) is analyzed with numerical model as the error and complementary error function. Results from in-situ test and analysis indicate that the contaminant concentration ratio as initial one ( C/$C_0$) increases as the radius ratio ( r/R) increases from the injection well, and also increases as the depth ratio ( z/ H) increases from the top of contaminated area. The elapse time needed to attain $50\%$ and $90\%$ clean up level ($ t_{50},\;t_{90}$) increases as the radius ratio ( r/R) and the depth ratio ( z/ H) increase. As above results, the procedure of soil flushing in contaminated area using vertical drains makes progress from the top of injection well to the bottom of extraction well.

High efficient Transflective TFT-LCD by tRGB-rW Sub-Pixel Rendering

  • Lin, L.;Liang, B.J.;Huang, C.M.;Lin, H.C.;Chen, Y.N.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1613-1617
    • /
    • 2006
  • The total light efficiencies of the novel 1.9" transflective tRGB-t/rW and tRGB-rW TFT LCDs are calculated and they are implemented by the traditional 7-mask ${\alpha}$-Si processing. Then, the two vehicles are turned on with the appropriate Sub-Pixel Rendering White (SPRW) algorithms, so they can exhibit the extra luminance without the original visual resolution loss. Their outstanding optical properties are approved by measuring the contrast ratio (C.R.) and the NTSC ratio. Because they utilize the light resource very effectively and efficiently, they are very suitable for the dark indoor and the bright outdoor environments.

  • PDF

Effect of Shape and Flow Rate on T10 in Clearwell (정수지의 형상과 유입 유량이 T10에 미치는 영향 연구)

  • Shin, Eun-Her;Kim, Sung-Hoon;Park, Hee-Kyung;Ahn, Jae-Chan;Choi, Jae-Ho;Choi, Young-June
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.819-826
    • /
    • 2005
  • To guarantee the disinfection ability in clearwell, a value of CT is considered where C[mg/l] is disinfectant residual at the exit of clearwell and T[min] means $T_{10}$, the contact time when 10% of tracer is out of clearwell after introducing the tracer at the inlet. To meet a CT value required, increasing the C value is not recommended because high C value can increase potential of producing disinfection by product like THMs. Increasing the hydraulic efficiency surrogated by $T_{10}$ is thus an option widely recommended. Right now, it is widely adopted estimating $T_{10}$ considering LW ratio only due to the suggestions of previous researches. The authors think however there are other factors to consider including shape, flow rate, configuration of inlet and outlet, and the existence of intra basin. This study is initiated to closely look at the effects of two factor on hydraulic efficiency. The factors are shape and inlet flow velocity, i.e., inflow. For that, computational fluid dynamics (CFD) model is developed and pilot test is also carried out. The results show that at a L/W ratio, disinfection ability is overestimated with larger length in shape and higher inlet flow velocity. This suggests that in determining $T_{10}$, the shapes of clearwell and inlet flow velocity should also be considered as well as L/W ratio.

An Experimental Study of The J-T Cryocooler with Mixed Refrigerant (혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구)

  • 이경수;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

Estimation of C(t) -Integral Under Transient Creep Conditions for a Cracked Pipe Subjected to Combined Mechanical and Thermal Loads Depending on Loading Conditions (열응력 및 기계응력이 작용하는 균열배관의 하중조건에 따른 천이 크리프 조건 C(t)-적분 평가)

  • Oh, Chang-Young;Song, Tae-Kwang;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.6
    • /
    • pp.609-617
    • /
    • 2011
  • There is a trend towards the progressive use of higher operating temperatures and stresses to achieve improved efficiencies in power-generation equipment. It is important to perform the crack assessment under hightemperature and high-pressure conditions. The C(t)-integral is a key parameter in crack assessment for transient creep states. The estimation of the C(t)-integral is complex when considering the mechanical and thermal loads simultaneously. In this paper, we study estimation of C(t)-integral under combined mechanical and thermal load depending on loading conditions.