• Title/Summary/Keyword: System solution

Search Result 10,635, Processing Time 0.038 seconds

Growth and Flowering Responses of Carnation (Dianthus caryophyllus) as influenced by Hydroponic Systems and Nutrient Solutions (재배방식과 양액의 종류에 따른 카네이션(Dianthus caryophyllus)의 생장과 개화반응)

  • 정순주;이범선;강종구;서범석
    • Journal of Bio-Environment Control
    • /
    • v.6 no.3
    • /
    • pp.190-197
    • /
    • 1997
  • This study was conducted to determine the optimum hydroponic system and nutrient solution for promoting the growth and flowering of hydroponically grown carnation. DFT (deep flow technique) and NFT (nutrient film technique) systems were employed and four kinds of nutrient solution, which are Cooper solution, Yamasaki solution, balanced nutrient solution by Japanese Horticultural Experiment Station and PTG solution in the Netherlands were used and compared. pH was lowest in the PTG solution compared to the other nutrient solutions used. Plant height was highest in the DFT system in the plot of PTG solution as of 53.0 cm at 88 days after transplanting, while lowest in NFT system with Cooper solution. Stem diameter was more thickened in NFT system with PTG solution as of 7.2 mm at 88 days after transplanting. Days to flowering was shortened to 122.3 days in NFT system when PTG solution was used. This results suggested a combination of NFT system with PTG solution as optimum hydroponic system and nutrient solution for cut carnation production. Further trials as to the management of nutrient solution by glowing stages should be followed.

  • PDF

Design and Implementation of Information Service System using the EPC on RFID Tag (전자 태그 기반 전자 상품 코드를 이용한 정보 서비스 시스템의 설계 및 구현)

  • Lee, Seung-ju;Lee, Myeong-Hwan;Yun, Yeo-Chang;Kim, Tae-Won;Park, Jong-ho;Shin, Young-hark
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.1136-1139
    • /
    • 2012
  • 본 연구에서는 EPCIS(전자상품코드 정보 서비스) 시스템의 요구사항인 추상화, 고성능, 확장성, 상호 운용성을 기반으로 EPCIS 시스템의 구조를 설계하고 구현한다. EPCIS 시스템의 추상화를 위해 기존에 존재하는 다양한 데이터 베이스 시스템과 상호 운용을 위한 공통 인터페이스를 구현하고 내부적으로 확장 질의 인터페이스, 공통 질의 언어를 가진다. 연속 질의 처리 시간을 감소 시키고 중복된 결과를 효과적으로 처리하기 위한 연속 질의 처리 모듈을 구현한다. 또한 RFID(전자 태그)의 이력 추적 질의의 고성능을 지원하기 위해 RFID 환경에 최적화된 색인 기술과 질의 처리를 위한 구성 요소(Component)를 추가하여 EPCIS 시스템의 고성능 질의 처리를 가능하게 한다. 또한 확장성을 위해 저장소(EPCIS Repository) 관리자를 구현하여 비즈니스 이벤트의 메타 데이터의 스키마를 정의하여 새로운 종류의 비즈니스 이벤트를 쉽게 등록하고 사용할 수 있도록 하였다. 또한 기업의 응용 시스템과 협력 기업간에 정보 교환을 위해서 EPC 글로벌에서 제시하는 웹 서비스를 지원하며 표준 데이터 형식인 확장성 생성 언어(XML)를 사용한다.

AN EXPERIMENTAL STUDY OF THE EFFECT OF CARIDEXTM CARIES REMOVAL SYSTEM ON THE REMOVAL OF CARIOUS DENTIN (CaridexTM Caries Removal System이 우식상아질 제거에 미치는 영향)

  • Kim, Hyeon-Seon;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.129-139
    • /
    • 1990
  • In order to determine if GK-101E(N-monochloro-DL-2-aminobutyrate) solution was effective in the removal of carious dentin, this study was conducted on 75 extracted human carious teeth. GK-101E solution was compared in effectiveness to saline solution.75 extracted human carious teeth were randomly assigned to two groups accordingly : (1) 50 teeth were treated with GK-101E solution : and (2) 25 teeth were treated with saline solution. Teeth in each group were divided into the medium or medium-hard consistency. Treatment consisted of directing the pulsating stream of each coded test solution utilizing the Caridex$^{TM}$ Caries Removal System against the carious surface for 4 mimutes. One operator treated all teeth with corded solution, and four investigators scored on the treated teeth based on visual examination and tactile evaluation with a dental explorer in conjunction with staining method with Caries Detector$^{TM}$ The results were as follows : 1. All groups showed various effect of carious dentin removal. 2. GK-101E solution was statistically superior to physiologic saline solution in the removal of carious dentin, regardless of carious consistency. 3. GK-101E solution in the medium-hard consistency was statistically superior to that in the medium consistency in the caries removal(p=0.001). 4. Saline solution in the medium consistency was equivalent to that in the medium-hard consistency in caries removal(p>0.1).

  • PDF

Development of a Remote Monitoring System of the Residual Amount of Ringer's Solution at Hospitals Using a Microprocessor (마이크로프로세서를 이용한 병원용 환자 링거액 잔류유량 원격 실시간 검사 시스템 개발)

  • Ha, Kwan-Yong;Gwon, Jong-Won;Odgelral, Odgelral;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.279-282
    • /
    • 2005
  • A real-time measurement and control system was developed, This system is used for nurses at hospitals to check the residual quantity and changing time of Ringer's solution in nurses' room. Load Cell is utilized as a sensor to check the residual quantity of Ringer's solution, This Load Cell detects the physical changes of Ringer's solution and transfers electronic signal to the amplifier. Amplified analog signal is converted into digital signal by NO converter. Developed Embedded system, which computes these data with microprocess(8052) then makes it possible to monitor the residual quantity of Ringer's solution real-time on a server computer. A Checking system on Residual Quantity of Ringer's Solution Using Load cell cut costs using a simple design for a circuit

  • PDF

Effect of Pressurization and Cooling Rate on Dissolution of a Stationary Supercooled Aqueous Solution (정지상태 수용액에서 가압과 냉각속도가 과냉각해소에 미치는 영향)

  • Kim, Byung-Seon;Peck, Jong-Hyun;Hong, Hi-Ki;Kang, Chae-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.12
    • /
    • pp.850-856
    • /
    • 2007
  • In a supercooled or capsule type ice storage system, aqueous solution (or water) may have trouble with non-uniform dissolution though the system contributes to the simplicity of system and ecological improvement. The non-uniform dissolution increases the instability of the system because it may cause an ice blockage in pipe or cooling part. In order to observe the supercooled state, a cooling experiment was performed with pressurization to an ethylene glycol(EG) 3 mass% solution in stationary state. Also, the effect of the pressurization from 101 to 505 kPa to the dissolution of supercooled aqueous solution was measured with the dissolution time of the supercooled aqueous solution at a fixed cooling rate of brine. At results, the dissolution of supercooled point decreased as the pressure of the aqueous solution in the vessel increased. Moreover, the dissolution point increased as the heat flux for cooling increased.

A Study on the COP Improvement of Absorption Chillers by Recovering Heat from the Condenser (응축기 배열회수에 의한 흡수식 냉동기의 고효율화에 관한 연구)

  • Park, Chan-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.738-744
    • /
    • 2006
  • In order to utilize the condensation heat of refrigerants in condenser on the absorption chiller system, the solution cooled condenser (SCC) was proposed using the weak solution of absorber as a cooling medium. The increase of COP with the increase of UA of the solution cooled condenser was approximately 0.009 in maximum with single effect one, and is about maximum 0.008 in occasion of double effect one with series flow compared to that without. In the case of heat exchanger, effectiveness is about 0.85, it's increments are 0.008 and 0.0072, respectively. And solution cooled condenser is more effective device in the single effect absorption system than double effect system for the principle of operation. On the other hand, as the solution split ratio increases when the value of UA is fixed, COP is increased and as the solution split ratio increases when the value of UA is fixed, COP is increased. If the flow rate of cooling water or the value of UA is reduced in order to increases the heat recovery of solution cooled condenser, heat recovery of solution cooled condenser is increased a little but COP is decreased as the system pressure is increased.

Demonstration Research of Photovoltaic System with Solar Reflectors (반사판을 이용한 태양광발전시스템 실증연구)

  • Kim, Yong-Sik;Kang, Gi-Hwan;Sim, Sang-Yong;Lee, Hoo-Rock;Lee, Jin-Seob;Hong, Jin-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.64-69
    • /
    • 2009
  • This paper aims at enhancing the electric production efficiency of photovoltaic(PV) system. The electrical power of PV system is proportional to light intensity on a PV module surface. In this paper, we apply two types of systems to enhance power generation efficiency. First, of all, concentring sunlight using specular surface and one-axis tracking system which traces the sun with vertical direction are applied in this project. From this, we analyze the fixed type method and power generation efficiency.

Experimental Performance Study of the Bubble Pump for the Diffusion Absorption Refrigerating System (확산형 흡수식 냉동시스템의 기포펌프 성능실험)

  • 이재효;정의갑;윤재호;정의갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.287-292
    • /
    • 2004
  • An experimental investigation was carried out to study the performance of a bubble pump for the diffusion absorption refrigerating system. Ammonia was used as the refrigerant and the helium was charged in order to balance the pressure between the low and high pressure side. As experimental variables, the concentration of ammonia charged into system, heat input, and the pressure of helium were selected. Experimental results show that the generation rate of ammonia vapor and the circulation rate of diluted ammonia solution were increased as the heat input increases, but the ratio of the solution to vapor flow rate was decreased. The generation rate of refrigerant vapor and the circulation rate of diluted ammonia solution increased as the system pressure decreased. Finally under the condition of 25 bars, the concentration of rich ammonia solution was not affected by the generation rate of ammonia vapor and the circulation of diluted ammonia solution.

Accuracy Analysis of 3D Positioning by GNSS(Global Positioning System) Positioning modes (GNSS 측위모드별 3차원 위치 정확도 해석)

  • Lee, Yong-Chang
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.169-171
    • /
    • 2010
  • The goal of this study is to evaluate the performance of different solution types(a GPS-only, a GLONASS-only, and a GNSS solution) on GNSS positioning modes which are point positioning and relative positioning(DGNSS-, Static-, and Kinematic-solutions). I started with GNSS sites of seoul metropolitan government's RTK network which providing combined GPS/GLONASS observations : Gangseo(GANS), Dobong(DBON). The positioning accuracy of different solution types on positining modes are compared. Considering the compared results of all cases, can find not only the difference of the performance between the GNSS solution and the GPS-only solution is very small, but also the GLONASS-only solution is not far from the other solution types taking into consideration that GLONASS system is not (yet) a complete system.

  • PDF

Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device (액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • v.22 no.4
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF