• Title/Summary/Keyword: System performance test

Search Result 7,410, Processing Time 0.038 seconds

Durability Evaluation of Platform Safety Step System (승강장 안전발판 시스템의 내구성 평가)

  • Park, Min Heung;Kwak, Hee Man;Kim, Min Ho
    • Journal of Applied Reliability
    • /
    • v.16 no.2
    • /
    • pp.125-133
    • /
    • 2016
  • Purpose: The purpose of this study is to evaluate durability of platform safety step system in railway. Method: We performed finite element analysis & durability analysis of platform safety step system with VPD (Virtual Product Development) techniques and examined the durability standard & qualification life through the rig test during no failure test time in reliability qualification test. We continued to test 1 million cycles in KRS (Korea Railway Standard) for system's robust design performance. Result: FEM analysis results are 14.9MPa & 14.7MPa of pin-joint, pivot and durability analysis result is above 1 million cycles. we calculated theoretically no failure test time 855,000 cycles and through the 1 million cycles durability rig test in KRS standard we confirmed product quality. Conclusion: This platform safety step system was designed very safe in terms of a mechanical strength & durability.

Unmanned WIG (U-WIG) Craft Design and Performance Test (무인 위그선 설계 및 성능시험)

  • Ahn, Byoung-Kwon;Jang, Jung;Song, Kwan-Hyung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.4
    • /
    • pp.396-402
    • /
    • 2008
  • As demands for high speed sea transportations have recently been increased, various high speed ships appear. Among them the WIG is believed to be one of the next generation of the sea transportation system. Test flight of the 20 seaters WIG craft, Haenarae-X1, developed by MOERI was a success in August, 2007. Development of the large WIG is now ongoing, and it is expected to be commercialized in the near future. In this study we designed a remote controled WIG Craft and carried out its performance test in order to establish engineering design procedures of an Unmanned WIG (U-WIG) craft.

A study on railway performance test management program building based on X-internet (X- 인터넷 기반의 철도성능시험관리 프로그램 구축에 관한 연구)

  • Ohn, Jung-Ghun;Kim, Myung-Ryoung;Yang, Doh-Chul
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.2096-2100
    • /
    • 2008
  • This research project management, building systems to test the performance requirements of a user to accept the plan and schedule management, personnel management, and test results, and the status of testing and reporting procedures to handle the process of implementation of Java-based X - Under the Internet environment, the default network, remote process research and development program as a test automation, structure and each module of the software analysis, design, analysis and clean-up and structure of the modules, each module and the GUI structure, performance, testing integration DB The present system is to study the system.

  • PDF

Performance Evaluation of Frame Synchronization Using Pilot Patterns in W-CDMA System (W-CDMA 시스템의 파일럿 패턴을 이용한 프레임 동기 성능 분석)

  • Song Young-Joon;Kim Han-Mook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.3 s.106
    • /
    • pp.272-279
    • /
    • 2006
  • In this paper, we evaluate the performance of frame synchronization words of pilot bit patterns which are used for the channel estimation and frame synchronization confirmation in W-CDMA(Wide band Code Division Multiple Access) system. W-CDMA system also uses compressed mode to make measurements from another frequency without a full dual receiver terminal. It is confirmed by using computer simulation that the proposed frame synchronization words also maintain the frame synchronization property in the compressed mode by using the complementary mapping relationship of preferred pair ROC(Receiver Operating Characteristic) curves with probability of detection and false alarm are used to analized the performance of the proposed frame synchronization words by using the various detection metrics such as LLRT(Log Likelyhood Ratio Test), GLRT(Generalied Likelyhood Ratio Test), soft and hard correlation tests in AWGN and Rayleigh fading channels. It is expected that the research results fer the performance of pilot bit patterns of this paper can be useful reference for the design and implementation of frame synchronization in 3rd generation W-CDMA system.

Fan Performance Test with Automatic Control and Measurement (자동제어계측을 이용한 송풍기 성능시험)

  • Choi, Young-Seok;Kim, Jin-Kwon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.373-378
    • /
    • 2003
  • In this paper, build up of fan performance tester in KITECH was introduced. The fan tester was set up based on AMCA standards 210-99, ANSI/ASHRAE 51-1999 with maximum flowrate within $1000\;m^{3}/min$. Both of inlet and outlet chamber setup with multiple nozzles described in AMCA 210 were established. The development of fully automatic control and measurement system are described. With this system, the accuracy of fan performance test can be maintained through the various flowrate and the uncertainty can be reduced.

  • PDF

Publishing a Web Based Crop Monitoring System and Performance Test (웹 기반 농업생산환경 모니터링 시스템 시범구축 및 성능평가)

  • Lee, Jung-Bin;Kim, Jeong-Hyun;Park, Yong-Nam;Hong, Suk-Young;Heo, Joon
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.5
    • /
    • pp.491-499
    • /
    • 2015
  • In developed countries such as USA and Europe, agricultural monitoring system is developed and utilized in various fields in order to predict crop yield, observe weather conditions and anomaly, categorize crop fields, and calculate areas for each crop. These system is Web Map Service(WMS) which utilizes open source and commercial softwares, and various information collected from remote sensing data are provided. This study will utilize tools such as GeoServer, ArcGIS Server, which are widely used to monitor agricultural production, to publish Map Server and Web Application Server. This enables performance test study for future agricultural production monitoring system by making use of response time and data transfer test. When tested in identical condition GeoServer showed a better result in response time and data transfer for performance test.

Design and Implementation of test system for safety separation and performance verification of aircraft weapons/equipment (항공기 무장/장착물의 안전 분리 및 성능 검증을 위한 점검 시스템 설계 및 구현)

  • Kim, Hyo-joung;Kim, Yang-won;Kwon, Byung-Gi
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.2
    • /
    • pp.47-53
    • /
    • 2022
  • With the recent development of defense technology, various aircraft armaments/equipments are being developed. Among them, cruise guided weapons(missile) for launching aircraft can be installed on aircraft aftersecuring reliability and safety through varioustests. In order to avoid collision with aircraft, missile separated from aircraft must release restraint of wing at the specified time, control wing in the specified direction. In order to confirm this, a test system that can control MIL-STD-1760 according to safety separation procedure and verify release performance is required. test system needs a function to check circuit for release of restraints and a function to check driving performance by controlling MIL-STD-1760. In addition, test system should be simulate environment separated from aircraft. This paper presented a testsystemthat can verify circuit and driving performance mounted on missile according to the safety separation procedure, and it was confirmed that it was normally separated from aircraft through flight tests.

Implementation of Electrical Performance Test Evaluation System for Car Fuel Heater (차량 연료히터의 전기적 성능시험 평가 시스템 구현)

  • Yoon, Dal-Hwan
    • Journal of IKEEE
    • /
    • v.17 no.1
    • /
    • pp.63-70
    • /
    • 2013
  • In this paper, we have implemented the performance evaluation system of the unified fuel heater for CRDI diesel engine. If the diesel engine be cold by low temperature in winter, then that makes the waxing materials like a paraffin and is the source of poor engine starting. The unified fuel heater is the barrow meter that estimate the start performance of diesel engine, and be tested by test chamber. The chamber perform the normal temperature, an extremely low temperature, an operating performance in an extremely high temperature, the resistance operation delay time and current operation delay time in setting up test resistance, the bimetal delay time test in temperature variation, the current and resistor test of the composited heater, a heating operation test.

A Study on the Performance of a Sprinkler System with Direct-Coupled Waterworks by Full-Scale Fire Test (실화재실험을 통한 상수도 직결형 스프링클러시스템의 성능에 관한 연구)

  • Jung, Jong-Jin;Nam, Dong-Gun;Lim, Woo-Sub
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.39-43
    • /
    • 2011
  • In this research, full-scale fire test was performed on a real house for the evaluation of the performance of waterworks direct-coupled sprinkler system. The fire was set to occur as spontaneous combustion as the cooking oil overheats. The size of house is $56m^2$ and it consists of a living room, a kitchen, and a room. In order to verify the performance of waterworks direct-coupled sprinkler system, it was installed in the kitchen. The result of the test showed that the fire started from the kitchen enlarged up to its ceiling but it was soon exhausted as the sprinkler started to work. The pressure of the waterworks was 0.28 MPa when the sprinkler operated, by which it verified that fire could go out even by waterworks pressure of the general residence.

Cooling and Heating Performance Evaluation of a GSHP System (지열원 열펌프 시스템의 냉${\cdot}$난방 성능 평가)

  • Sohn Byong Hu;Cho Chung-Sik;Shin Hyun-Jun;An Hyung-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.71-81
    • /
    • 2005
  • The main objective of the present study is to investigate the performance characteristics of a ground-source heat pump(GSHP) system with a 130 m vertical and 62 mm nominal diameter U-tube ground heat exchanger. In order to evaluate the performance analysis, the ground-source heat pump connected to a test room with $90\;m^2$ floor area in the Korea Institute of Construction $Technology(37^{\circ}39'N,\;126^{\circ}48'E)$ was designed and constructed. This ground-source heat pump system mainly consisted of ground heat exchanger, indoor heat pumps and measuring devices. The cooling and heating loads of the test room were 5.5 and 7.2 kW at design conditions, respectively. The experimental results were obtained from July 2, 2003 to July 1, 2004. The cooling and heating performance coefficients of the system were determined from the measured data. The average cooling and heating COPs for the system were obtained to be 4.90 and 3.96, respectively. The temperature variations in ground and the ground heat exchanger pipe surface at different depths were also measured.