• Title/Summary/Keyword: System of Circulation

Search Result 1,701, Processing Time 0.033 seconds

Circulation System of Geographical Knowledge for the Sustainable Development of Geography (지속가능한 지리학 발전을 위한 지리지식의 순환체계)

  • Moon, Nam-Cheol
    • Journal of the Korean association of regional geographers
    • /
    • v.20 no.4
    • /
    • pp.473-483
    • /
    • 2014
  • The geographical knowledge is composed of academic geographical knowledge, school geographical knowledge, applied geographical knowledge and popular geographical knowledge according to the diverse social need and demand. And the geographical knowledge has developed through the knowledge circulation system, which is connected to knowledge production, delivery, application and to reproduction among these knowledge fields. The discontinuity of knowledge circulation can lead to crisis of geographical whole. Therefore, for sustainable development of geography, it is necessary to firmly build a virtuous circulation system of geographical knowledge which is linked to a knowledge production and accumulation by an academic geography, knowledge delivery by a school geography, knowledge social application by an applied geography, knowledge application in everyday life by a popular geography and knowledge reproduction by an academic geography.

  • PDF

A Study on Substrate Stage Temperature (기판스테이지 온도에 관한 연구)

  • Kim, Sun-Ki;Lee, Woo-Young;Kang, Heung-Suk
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.4 s.17
    • /
    • pp.35-40
    • /
    • 2006
  • This paper shows that the effect of exposing on the top area and a solution which using a water circulation system. Semiconductor substrate stage is made from Aluminum and is repeated the sequence of exposing (150), turning OFF shutter, taking 30 sec. interval at the top area of stage. So the temperature of substrate temperature rises continuously. On this, we made a waterway at the inner part of the substrate stage and operated a water circulation system. We measured the temperature of a substrate stage surface with a thermocouple attached to the substrate stage. To analyze the top area's temperature, we used Analysis Program ANSYS for analysis and 3D CAD program Solid-Works for modeling.

  • PDF

Performance Analysis and Test of a Small-Scale Natural Circulation Vertical Evaporator (소형 자연순환 수직형 증발기 해석 및 성능실험)

  • Cha, Sang-Jin;Kim, Nae-Hyun;Ryu, Jin-Sang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.9
    • /
    • pp.595-603
    • /
    • 2011
  • In this study, an effort has been made to analyze the subcooled boiling heat transfer in a natural circulation vertical evaporator. To verify the analysis, a small-scale model was made and tested. The friction correlation by Ueda, void fraction and quality correlation by Saha and Zuber along with the superposition heat transfer model by Rohsenow yielded a satisfactory agreement with the model test data. The analysis was extended to simulate a 1 ton/day concentration system. Comparison with the test results of 1 ton/day prototype revealed that the data were overpredicted by 13%. The capacity of the prototype was 1.2 ton/day with COP of 5.77.

The Magnetic Finishing Characteristics of Pipe Inside Polished by Slurry Circulation System (슬러리 순환방식을 이용한 파이프 내면의 자기연마특성)

  • Park, Won-Kyou;Choi, Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.1
    • /
    • pp.38-44
    • /
    • 2004
  • An internal finishing process by the application of magnetic abrasive machining has been developed as a new technology to obtain a fine inner surface of non-ferromagnetic pipe. In this paper, an abrasive slurry circulation system was designed and manufactured. As a result, it was found that a fine inner surface of pipe was available by the use of these machining methods. The basic machining characteristics of pin-type magnetic tools were analyzed experimentally. In addition, the experimental results show that pin-type magnetic tools have more machining efficiency than Iron particles as magnetic tools.

  • PDF

Humidity Effect on the Hydrogen Re-circulation Ejector Performance (고습의 흡입 유체일 때 이젝터의 성능 변화)

  • JeGal, Seung;Song, Seung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2589-2593
    • /
    • 2008
  • In a fuel cell vehicle using polymer electrolyte membrane fuel cell(PEMFC), hydrogen is over-supplied to gain higher stack efficiency. So it is needed considering fuel efficiency to re-circulate hydrogen which is not reacted in stack. And to re-circulate hydrogen, a blower or an ejector is used. Ejector re-circulation system has several merits compared with blower system, for example no parasite energy, simple structure and no lubrication system. But the secondary flow of an ejector in fuel cell vehicle, has high humidity because of crossover problem in stack. Therefore in this paper, ejector is designed by 1-D modeling and CFD with the primary and secondary flow of hydrogen. And the ejector which has the primary and secondary flow of air, is designed to have the same Reynolds number and Mach number at the nozzle exit as the hydrogen ejector's. And this air ejector is tested while the humidity of the secondary flow is varied.

  • PDF

Investigation of Characteristics of Passive Heat Removal System Based on the Assembled Heat Transfer Tube

  • Wu, Xiangcheng;Yan, Changqi;Meng, Zhaoming;Chen, Kailun;Song, Shaochuang;Yang, Zonghao;Yu, Jie
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1321-1329
    • /
    • 2016
  • To get an insight into the operating characteristics of the passive residual heat removal system of molten salt reactors, a two-phase natural circulation test facility was constructed. The system consists of a boiling loop absorbing the heat from the drain tank, a condensing loop consuming the heat, and a steam drum. A steady-state experiment was carried out, in which the thimble temperature ranged from $450^{\circ}C$ to $700^{\circ}C$ and the system pressure was controlled at levels below 150 kPa. When reaching a steady state, the system was operated under saturated conditions. Some important parameters, including heat power, system resistance, and water level in the steam drum and water tank were investigated. The experimental results showed that the natural circulation system is feasible in removing the decay heat, even though some fluctuations may occur in the operation. The uneven temperature distribution in the water tank may be inevitable because convection occurs on the outside of the condensing tube besides boiling with decreasing the decay power. The instabilities in the natural circulation loop are sensitive to heat flux and system resistance rather than the water level in the steam drum and water tank. RELAP5 code shows reasonable results compared with experimental data.

Investigation into circulation of ground water by air sparging (Air sparging에 의한 지하수 순환에 관한 연구)

  • 이준희;강구영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.232-235
    • /
    • 1998
  • Air sparging system is a kind of in-situ bioremediation method in the contaminated ground water. When Air sparging, the both of water circulation and oxygen transfer happend in the same time. The hydraulic differential head is zero at the middle height of well, is negative below the height and is possitive above the height. Hydroraulic head gradient is proportioned to air superficial velocity in the well. But over 24m/min of the superficial velocity, the hydraulic head gradient increase little.

  • PDF

Freeze Protection for Passive Solar Water Heating System in Bitter Cold Areas (혹한기 지역에서의 자연순환형 태양열 시스템 동파방지)

  • Kwon, Jae-Wook;Kim, Jong-Hyun;Hong, Hi-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.41-46
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and excessive electric power consumption. In the experimental device, hot water in a storage tank was circulated by a small pump and used to heat the outdoor pipes if the cold water pipe surface temperature falls lower than a set point. As a result, It was observed that there was no hot water waste while the solar water heating system operated without freeze and burst.

A Simulation on the Two-Phase Flow Characteristics in Gas Bubble Driven Circulation Systems (Gas Bubble Driven Circulation Systems에서의 이상유동 특성의 시뮬레이션)

  • 최청렬
    • Journal of the Korea Society for Simulation
    • /
    • v.7 no.2
    • /
    • pp.17-32
    • /
    • 1998
  • The flow fields in Gas Bubble Driven Circulation Systems were numerically analyzed. In various gas flow rate and bubble size, the flow characteristics were predicted. Eulerian-Eulerian approach was used for the formulation of both the continuous and dispersed phases. The modification of the general purpose computer program PHOENICS code was employed to predict the mean flow fields, turbulent characteristics, gas dispersion, volume fraction. The predicted shows very satisfactory agreement with experimental results for all regions of ladle. The results are of interest in the design and operation of wide variety of material processing.

  • PDF

A Study on Stormwater Retention and Infiltration Ponds System for Improvement of Water Circulation and Increase of Bio-diversity (물 순환 개선 및 생물다양성 증진을 위한 우수저류 및 침투연못 시스템에 관한 연구)

  • Kim, Kwi-Gon;Kim, Hyea-Ju;Lee, Jae-Chul;Kim, Jong-Sub;Jang, Hey-Young;Son, Sam-Gi
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.3 no.2
    • /
    • pp.53-65
    • /
    • 2000
  • The objectives of this study are to develop a stormwater management system that would contribute to improving water circulation, recycling storm water and promoting biodiversity in urban areas, to apply the system in an actual site, and to verify its effectiveness in order to generate a stormwater management system applicable in Korea. This study reviewed former researches and case studies, categorized stormwater management system into pre-treatment, retention and infiltration phases, and analyzed the strength and weakness of the techniques by synthesizing unit techniques of each stage. As a result, the process of the stormwater management system includes the following phases: 1) a rubble filtration layer; 2) a retention pond; 3) a infiltration pond; and 4) a stormwater retention pool (recirculation and recycling). Then, an empirical study to design and create the generated system according to the features of a site and to verify its effectiveness was conducted. The future study direction is to verify the effectiveness of the developed stormwater retention and infiltration ponds. To this end, it is planned to perform hydrological monitoring using automatic measuring equipment and monitoring on habitat bases and the biota living on the base. Based on its outcome, the applied model would be refined and improved to develop an alternative stormwater management system that would allow to achieve the improvement of urban water circulation, increase of biodiversity and efficient use of water resources.

  • PDF