• Title/Summary/Keyword: System analyzer

Search Result 1,148, Processing Time 0.029 seconds

Studies on the Development of the Automatic Blood Analyzer with Silicone Rubber-Based Solid-State $K^+$- and $Na^+$-Selective Electrodes (실리콘러버 지지체의 $K^+$$Na^+$ 선택성 고체형 전극을 이용한 자동혈액분석기의 개발에 대한 연구)

  • Kang, Myung-Sung;Jeon, Woo-Sung;Kim, Sun-Kwan;Kim, Dea-Hoon;Cha, Geun-Sig;Nam, Hak-Hyun;Cho, Han-Ik;Park, Sung-Sup
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.26-33
    • /
    • 1995
  • Silicone Rubber (SR)-based potassium- and sodium-selective solid-state electrodes have been developed for the portable blood electrolyte analyzer system. The electrochemical performance of these electrodes have been evaluated with a static experimental setup and with the newly developed blood electrolyte analyzer system (model; HS603). It has been shown that their potentiometric properties are essentially comparable to those of PVC-based ion-selective electrodes, but with greatly improved lifetime (200 and 40 days for potassium and sodium sensors, respectively) and potential stability (within $\pm0.1$ mV). Clinical tests have been performed with real serum samples and the results have been compared with those obtained from Ciba-Corning BGA 288 system; correlations were excellent, proving its practical utility as a new commercial system.

  • PDF

Implementation of Data Mining Engine for Analyzing Alert Data of Security Policy Server (보안정책 서버의 경보데이터 분석을 위한 데이터마이닝 엔진의 구현)

  • 정경자;신문선
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.4
    • /
    • pp.141-149
    • /
    • 2002
  • Recently, a number of network systems are developed rapidly and network architectures are more complex than before, and a policy-based network management should be used in network system. Especially, a new paradigm that policy-based network management can be applied for the network security is raised. A security policy server in the management layer can generate new policy, delete. update the existing policy and decide the policy when security policy is requested. The security server needs to analyze and manage the alert message received from server Policy enforcement system in the enforcement layer for the available information. In this paper, we implement an alert analyzer that analyze the stored alert data for making of security policy efficiently in framework of the policy-based network security management. We also propose a data mining system for the analysis of alert data The implemented mining system supports alert analyzer and the high level analyzer efficiently for the security.

  • PDF

Design and Implementation of A VXIbus Device for FFT Analysis (FFT분석을 위한 VWIbus 디바이스의 설계 및 구현)

  • 강민호;노승환;전동근;문대철;김덕진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.11
    • /
    • pp.1754-1766
    • /
    • 1993
  • The application of VXIbus system, an Industry standard, is rapidly spreading with its ability to offer the easiness of integration from GPIB and the fast data transmission from VMEbus system. Compared with VXIbus Register Based Device, VXIbus Message Based Device has a drawback In the aspect of speed. But it is possible to utilize high level ASCII commands to control a Message Based Device, therefore system integration is much easier with Message Based Device than with Register Based Device. And, the FFT analyzer is an instrument for signal analysis which can be inexpensively implemented to be fast and have high resolution. Its wide ability of analysis presents numerous application. So, it is necessary to apply VXIbus system to FFT analyzer. In this paper, the implementation of FFT analyzer is performed using a DSP module and by implementing all A/D conversion circuit and a control module which performs VXIbus interface. The device can be controlled by Slot0 Commender which supports VXIbus Shared Memory Protocol through VXIbus.

  • PDF

Development of Primary Color Reaction System of Urine Analyzer for U-health (유헬스용 요분석기의 정색반응 시스템 개발)

  • Lee, Sang-sik;Park, Won-yeop;Goo, Ji-hyun;Lee, Choong-ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.2
    • /
    • pp.9-14
    • /
    • 2009
  • This study was conducted to develop a electronic circuit of primary color reaction for urine analyzer for measuring color response of urine strip. A primary color reaction system is equipped with the computer, electronic circuit, tray, detecting assembly and software. The determination of coefficient($R^2$) between reagent and color sensor were 0.9801(R), 0.9868(G) and 0.9837(B). To evaluate the system verification, we measured the primary color reaction of erythrocytes, Bilirubin, Urobilinogen, Ketones and Protein. We concluded that it is possible to use the developed the primary color reaction system for urine analyzer using u-health.

  • PDF

DEVELOPMENT ON ENHANCED LEAKED FUEL RECIRCULATION DEVICE OF LPLi ENGINE TO SATISFY SULEV STANDARD

  • Myung, C.L.;Kwak, H.;Park, S.
    • International Journal of Automotive Technology
    • /
    • v.7 no.4
    • /
    • pp.407-413
    • /
    • 2006
  • The liquefied petroleum gas(LPG), mixture of propane and butane, has the potential to reduce toxic hydrocarbon emissions and inhibit ozone formation due to its chemical composition. Conventional mixer systems, however, have problems in meeting the future lower emission standards because of the difficulty in controlling air-fuel ratio precisely according to mileage tar accumulation. Liquid Phase LPG injection(LPLi) system has several advantages in more precise fuel metering and higher engine performance than those of the conventional mixer type. On the other hands, leakage problem of LPLi system at the injector tip is a main obstacle for meeting more stringent future emission regulations because these phenomena might cause excessive amount of THC emission during cold and hot restart phase. The main focus of this paper is the development of a leaked fuel recirculation system, which can eliminate the leaked fuel at the intake system with the activated carbon canister. Leaked fuel level was evaluated by using a fast response THC analyzer and gas chromatography. The result shows that THC concentration during cold and hot restart stage decreases by over 60%, and recirculation system is an effective method to meet the SULEV standard of the LPLi engine.

Development of a Residual Gas Analyzer Calibration System (잔류기체 분석기 교정장치 개발)

  • Hong, S.S.;Lim, I.T.;Kim, J.T.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.91-98
    • /
    • 2007
  • The Korea Research Institute of Standards and Science (KRISS) has developed a residual gas analyzer (RGA) calibration system and measured gas sensitivities for two different types QMSs using nitrogen, argon, and helium. Different gas sensitivities were identified according to mass and pressure, so it was revealed that the gas sensitivity correction is necessary for proper use of mass spectrometers.

Implementation of ISDN User/Network Protocol Analyzer on PC-based System (PC 환경에서 ISDN 사용자/망 프로토콜 분석기의 개발)

  • 정중수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.6B
    • /
    • pp.1068-1073
    • /
    • 1999
  • On the emergence of ISDN which has been introduced in the year 1980, various services are supported. This paper presents implementation of ISDN user/network protocol analyzer based on PC-extension card. Firmware and software are loaded on the PC-extension card using PC 05. The performance analysis on D-channel signalling on this system is surveyed. The monitoring results satisfiy with ISDN BRI or PRI interfaces.

  • PDF

The Study of Gas Sensor Using Rheological Properties of Polymeric Sensitive LB Films (고분자감응성 LB막의 유변학적인 특성을 이용한 가스센서 연구)

  • 강현욱;김정명;권영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.198-201
    • /
    • 1997
  • The new system for identification of organic vapours and analysis method of mechanism between organic vapours and sensitive materials were attempted using the resonant resistance and resonant frequency of Quartz Crystal Analyzer (Q. C. A.). The resonant resistance shift means rheological changes in sensitive LB films occurred by the adsorption of organic vapours, while the resonant frequency shift represent the mass of organic vapour loaded in or on the sensitive LB films. It is thought that we can obtain more accurate response mechanism of organic vapour using the resonant frequency and resonant resistance diagram. The polymeric sensitive material were quantitively depositied using the LB method. In the experimental results, the adsorption behavior of organic vapour response can be decided by two type ; surface adsorption and penetration into sensitive material. Organic vapours had different positions in the Frequency-Resistance (F-R) diagram as to the kinds and concentrations of organic vapours. Thus F-R diagram can be applied to the development of one channel gas sensing system using the Quartz Crystal Analyzer.

  • PDF

Development of MARS Transient Analyzer

  • Hwang, M.K.;Kim, K.D.;Jeong, J.-J.;Lee, Y.J.;Chung, B.D.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2002.10a
    • /
    • pp.155.2-155
    • /
    • 2002
  • A visual environment for system analysis codes (hereinafter called "ViSA") has been developed to support code users in their input preparations, code executions, and output interpretations. ViSA provides a more convenient way for base input data generation and modification on a user-friendly basis. It also provides on-line graphical displays to give an in-depth understanding of transient thermal-hydraulic behaviors in nuclear power plants. This paper presents the main features of ViSA.

  • PDF

The Code Generating System using Noncircular Attribute Grammar (비 환형 속성 문법을 이용한 코드 생성 시스템)

  • Kim, Sang-Hoon
    • The Journal of Information Technology
    • /
    • v.6 no.4
    • /
    • pp.113-123
    • /
    • 2003
  • This paper is the study for code generation using attribute grammar without cycle. For the purpose of this study, we designed metalanguage SDL which describes an attribute grammar and, represented attribute grammar to SDL. This attribute grammar is based on L-attributed grammar without cycle. This system consists of attributed-grammar analyzer and attribute evaluator. Attributed grammar analyzer takes a semantic description language and then generates useful informations that are needed by attribute evaluator. The evaluator calculates an attribute values using these information.

  • PDF