• Title/Summary/Keyword: System air conditioner

Search Result 407, Processing Time 0.024 seconds

Acoustical Characteristics of System Air Conditioners Installed in the Ceiling (천장형 시스템 에어컨의 음향 특성)

  • Kim, Su-Yeon;You, Jin;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.662-665
    • /
    • 2005
  • In this study acoustical characteristics of system air conditioner in different ceiling systems was investigated in anechoic and real conditions. Same Types of air conditioners were installed in two different rooms. The results showed that motor's tonal component was emphasized at near fart of air blast blower in the exposed type while fan's harmonic component is emphasized rather in the enclosed type. This confirms tile result of acoustical intensity mapping which showed that Intensity level of 125Hz octave band increased in the exposed type while there was no noticeable difference at the frequency band in the enclosed type.

  • PDF

Study on the Performance of an ATES Geothermal Heat Pump System and Economic Analysis (ATES 열펌프 시스템 성능 및 경제성 분석에 관한 연구)

  • Oh, Myung-Suk;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.289-296
    • /
    • 2012
  • The aim of this study is to investigate the performance of a heating and cooling system with aquifer thermal energy storage(ATES heat pump system) known as one of the underground thermal energy storage application systems. The ATES system was composed of heat pump unit and ATES, which was installed in a factory building located in Anseoung. The system represented very high heating and cooling performance, and showed nearly constant COP at each heating and cooling season due to the stability of EWT. The economic analysis about an ATES system and a conventional system was also executed. The conventional system adopted an air-conditioner in the summer season and a LNG boiler in the winter season. The payback period of the ATES system was estimated by 6.62 years.

LCC Analysis of Residential Dehumidifying Air Conditioning System using Thin Separation Membrane (분리막을 이용한 주거용 제습공조시스템의 LCC 분석)

  • Jung, Yong-Ho;Park, Seong-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.1
    • /
    • pp.10-16
    • /
    • 2018
  • The climate of summer in Korea is quite hot and humid. Many studies have been carried out to reduce the energy required for operating a dehumidifier. The dehumidifier is mainly connected to the cooling system since it operates in the summer. Conventional dehumidification methods often require additional cooling and energy for dehumidification. In this study, a system for increasing the efficiency by applying a membrane was analyzed. Its energy saving effect was analyzed when it was applied to residential buildings. Economic efficiency was also evaluated. As a result of this study, 9.0% energy savings were achieved for residential buildings. The investment recovery period was 28.9 years. Such long investment recovery period was because the initial investment cost was excessive and annual energy saving only appeared in the summer.

Fan Noise Prediction Method of Air Cooling System (공기 냉각 시스템의 홴 소음 예측 기법)

  • Lee, Chan;Kil, Hyun-Gwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.9
    • /
    • pp.952-960
    • /
    • 2008
  • Fan noise prediction method is presented for air conditioning, automobile and electronic cooling system applications where fan acts as an internal equipment having very complicated flow interaction with other various system components. The internal flow paths and distribution in the fan-applied systems such as computer or air conditioner are analyzed by using the FNM(flow network modeling). Fan noise prediction method comprises two models for the discrete frequency noise due to rotating steady aerodynamic lift and blade interaction and for the broadband noise due to turbulent boundary layer and wake vortex shedding. Based on the fan operation point predicted from the FNM analysis results and fan design parameters, the present far noise model predicts overall sound pressure level and spectrum. The predictions for the flow distribution, the fan operation and the noise level in air cooling system by the present method are well agreed with 3-D CFD and actual noise test results.

A Study on the Fail Safety Logic of Smart Air Conditioner using Model based Design (모델 기반 설계 기법을 이용한 지능형 공조 장치의 이중 안전성 로직 연구)

  • Kim, Ji-Ho;Kim, Byeong-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.12
    • /
    • pp.1372-1378
    • /
    • 2011
  • The smart air condition system is superior to conventional air condition system in the aspect of control accuracy, environmental preservation and it is foundation for intelligent vehicle such as electric vehicle, fuel cell vehicle. In this paper, failure analyses of smart air condition system will be performed and then sensor fusion technique will be proposed for fail safety of smart air condition system. A sensor fusion logic of air condition system by using CO sensor, $CO_2$ sensor and VOC, $NO_x$ sensor will be developed and simulated by fault injection simulation. The fusion technology of smart air condition system is generated in an experiment and a performance analysis is conducted with fusion algorithms. The proposed algorithm adds the error characteristic of each sensor as a conditional probability value, and ensures greater accuracy by performing the track fusion with the sensors with the most reliable performance.

A Study on Control and Monitoring System for Building Energy Management System

  • Oh, Jin-Seok;Bae, Soo-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.335-340
    • /
    • 2011
  • Building energy saving is one of the most important issues in these days. Control algorithm for energy saving should be designed properly to reduce power consumption in building. Recently, building energy system consists of hybrid energy system coupling with RE (Renewable Energy) source. In this paper, an optimum control algorithm for building energy saving is applied to BEMS (Building Energy Management System) by using an outdoor air temperature prediction strategy. BEMS coupling with renewable energy can control HVAC (Heating, Ventilating and Air-Conditioning) system effectively. In order to verify the effectiveness of building energy saving, BEMS was tested for several months at a laboratorial chamber with an air conditioner, fan and heater. To this end BEMS embedded control algorithm has been tested successfully.

The Development of the Certification System for Remote Controlled Air Conditioners (원격제어에어컨 인증시험 장치 개발)

  • Kim, Myong-Soo;Hyun, Duck-Hwa;Cho, Seon-Ku;Kim, Choong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2455-2457
    • /
    • 2001
  • The Remote controlled air conditioner is to effectively suppress the peak load generated from air conditioners in summer. It is important that remote controlled air conditioners are operated well in the real field. Almost 3,200 remote controlled air conditioners has been distributed as of the end of June, 2001. This paper describes a development of the certification system for the air conditioners.

  • PDF

A Study of Thermodynamic Cyclic Characteristics of HFC-134a Automotive Air-Conditioner System (HFC-134a 자동차용 공조시스템의 열역학적 사이클 특성에 관한 연구)

  • Lee, K.H.;Won, J.P.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.1
    • /
    • pp.51-64
    • /
    • 1994
  • Analytical study on the thermodynamical cyclic behabiour and characteristics of HFC-l34a refrigerant for automotive air conditionser system for the replacement of existing CFC-12 has been carried out in this paper through development of system performance simulation program, expecially in the view point of system design considerations. The results indicate that HFC-l34a system will give a greater refrigerating capacity than CFC-12 if appropriate engineering measures such as proper codensers, flow controllers, etc., taken for certain operating conditions. The results, however, also show that the operating power for compression process increases over entire temperature range as a result of decreasing volumetric efficiency due to larger specific volume and increased discharging pressure. The present study results indicate that proper selection of condensing and evaporating temperature plus refrigerant control is very important performance factor to have better COP in the HFC-134a system design.

  • PDF