• Title/Summary/Keyword: System T/H Analysis

Search Result 670, Processing Time 0.037 seconds

Analysis of Pulse Wave Parameters According to Aging for Arteriosclerosis Evaluation (동맥경화 평가를 위한 연령별 맥파 주요인자 분석)

  • Lee, Na-Ra;Lee, Seung-Wook;Kim, Soo-Byeong;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.79-89
    • /
    • 2011
  • Objectives : The aim of this study is to propose the W area of pulse (AW) as a new index which can confirm the arteriosclerosis by analyzing parameters of 5-level pressure pulse waveform measurement system for normotensive group according to aging. Methods : We measured radial pulse waveforms of normotensive group (20 to 60 years old) using 3-dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea). And then we analyzed various parameters for sclerosis of the arteries such as Height (h1, h2, h3, h4, h5), Time (t1, t2, t3, t4, t5), AW, AW rate, Total area of pulse (At) and Augmentation Index (AIx). Results : As a result of analyzing parameters according to the aging, h2, h3, AS (systolic area rate to AT), AIx and AW were increased but t2/t, t3/t, t5/t and AD (diastolic area rate to AT) were decreased. Conclusions : We checked blood vessel conditions for normotensive group according to aging and confirmed various parameters. Also, we found that AW was analogous to AIx which has been used for diagnosing arteriosclerosis. Furthermore, we confirmed the usefulness of AW as a new parameter for checking vessel condition and characteristic compared with the AIx.

A Study on Probabilistic Reliability Evaluation by Using PRA (PRA를 이용한 확률론적 신뢰도 평가에 관한 연구)

  • Kwon, J.J.;Taan, T.T.;Jeong, S.H.;Bo, Shi;Choi, J.S.;Cha, J.M.;Yoon, Y.T.;Choi, H.S.;Jeon, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.27-29
    • /
    • 2006
  • This paper deals with the application of the concept of POM to analysis of power system behavior and describes a practical method of PRA for KEPCO system. This paper presents not only marginal power flow evaluation of KEPCO system in view point of physical and operation mode by using Physical and Operational Margins (POM Ver. 2.2), which is developed by V&R Energy System Research, but also by using Probabilistic Reliability Assessment (PRA Ver.3.1), which is developed by EPRI. The ability of the method to provide insights on root causes, weak points and regional causes and effects was shown. The approach offers fast and accurate determination of bottlenecks in the transmission network and optimal mitigation measures to alleviate the identified violations.

  • PDF

Performance Analysis of a Combined Power Cycle Utilizing Low-Temperature Heat Source and LNG Cold Energy (저온 열원 및 LNG 냉열을 이용하는 복합 발전 사이클의 성능 해석)

  • Kim, Kyoung-Hoon;Oh, Jae-Hyeong;Ko, Hyung-Jong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.4
    • /
    • pp.382-389
    • /
    • 2012
  • Power generation cycle using ammonia-water mixture as working fluid has attracted much attention because of its ability to efficiently convert low-temperature heat source into useful work. If an ammonia-water power cycle is combined with a power cycle using liquefied natural gas (LNG), the conversion efficiency could be further improved owing to the cold energy of LNG at $-162^{\circ}C$. In this work parametric study is carried out on the thermodynamic performance of a power cycle consisted of an ammonia-water Rankine cycle as an upper cycle and a LNG cycle as a bottom cycle. As a driving energy the combined cycle utilizes a low-temperature heat source in the form of sensible heat. The effects on the system performance of the system parameters such as ammonia concentration ($x_b$), turbine 1 inlet pressure ($P_{H_1}$) and temperature ($T_{H_1}$), and condenser outlet temperature ($T_{L_1}$) are extensively investigated. Calculation results show that thermal efficiency increases with the increase of $P_{H_1}$, $T_{H_1}$ and the decrease of $T_{L_1}$, while its dependence on $x_b$ has a downward convex shape. The changes of net work generation with respect to $P_{H_1}$, $T_{H_1}$, $T_{L_1}$, and $x_b$ are roughly linear.

Measurement and Analysis of Electric and Magnetic Fields near a Transmission Tower (송전철탑 주변에서 전장과 자장의 측정과 분석)

  • Lee, B.H.;Gil, H.J.;Ahn, C.H.;Lee, K.O.;Park, T.W.;Kwak, H.R.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1827-1829
    • /
    • 1997
  • In this paper, measurement and analysis of ELF electric and magnetic fields due to a transmission line have been carried out and the power frequency field strength measuring system is designed. In order to evaluate electric and magnetic fields associated with 60 Hz electric power transmission and distribution lines, the actual survey near a transmission tower has been made and analyzed. It may be inferred from these results that the maximum electric and magnetic fields strength in the vicinity of a line tower do not exceed 3.5[kV/m] and 20[${\mu}T$]. The results of the field measurements agree with limits and guidelines recommended by various authorized international institutes.

  • PDF

Numerical Analysis on Effect of the Environmental Velocity for Circular Heating Source with Heat Generation (열생성을 가진 원형발열체의 외부 유속의 영향에 대한 수치해석)

  • Bae, K.Y.;Ji, M.K.;Chung, H.S.;Chung, H.T.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.8 no.1
    • /
    • pp.30-35
    • /
    • 2004
  • This paper represents the numerical analysis on effect of the environmental velocity for circular heating source with heat generation. In general heating system, the oil and sheath heater is widely used, but these systems have many problems. So, the heating source with carbon ingredient has been researched in many country about manufacture, thermal and electrical properties. In this research, a circular heating source was studied through numerical analysis on several conditions of unsteady state, beat generation and environmental velocity. The temperature distributions at steady state is appeared as a non-linear pattern with variations of environmental velocity. So, the correlation equation between temperature at steady state and environmental velocity was obtained.

  • PDF

Operating Characteristics of Actuator System for Automatic Door Operated by Temperature Detecting Sensor (온도 감지 센서가 구비된 도어 자동 개폐기 구동용 액추에이터 시스템의 동작 특성 해석)

  • Kim Y. H.;Son W. T.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.815-817
    • /
    • 2004
  • This paper deals with the characteristics analysis and experiments of operating actuator for automatic door operated by fire detecting sensor. The dynamic characteristics of operating actuator system are analyzed on the structure of the operating actuator model. Simulation and experimental result have been performed for the verification of the proposed system and dynamic characteristics applied to a actuator by electromechanical energy conversion theory. The experimental result have been compared with proposed theoretical predictions. In this experimental result represented the temperature T1 and T2 which remarks T1 is a circumstance of operating actuator system, and T2 is a fire detecting sensor part.

  • PDF

An Analysis of the Water Supply System with Pressurizing Tank (가압탱크를 이용한 급수시스템의 해석 및 최적화 연구)

  • Lee, T.W.;Kim, T.H.;Choi, D.H.;Kim, S.D.;Kim, J.P.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.93-102
    • /
    • 1994
  • It is the goal of this study to provide the essential data for design and operation of optimum water supply system. Experimental and theoretical analyses have been conducted for various parameters, for example, volume and air percent of pressurizing tank, pump speed and pressure range inside tank, etc. Pressure inside tank with time, flow rate, energy consumption rate and pump operation time have been obtained for design and operating parameters to optimize the components and to establish the operating method of system, and therefore to contribute to the development of technology from a point of view of the improvement of quality, the enhancement of system efficiency and the reduction of construction cost.

  • PDF

Numerical Analysis on the $2^{nd}$ Discharae-passase In Reciprocating Compressor (왕복동식 수소압축기의 2단 토출통로 유동해석)

  • Lee, G.H.;Rahman, M. Sq.;Kim, C.P.;Joung, T.W.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.13 no.3
    • /
    • pp.27-32
    • /
    • 2009
  • Numerical analysis information of a complex discharge-passage will be very useful to improve hydrogen compression system. General information about an internal gas flow is presented by numerical analysis approach. Relating with hydrogen compressing system, which have an important role in hydrogen energy utilization, this should be a useful tool to observe the flow quickly and clearly. Flow characteristic analysis, including pressure and turbulence kinetic energy distribution of hydrogen gas from cylinder going to the chamber of a reciprocating compressor are presented in this paper. Discharge-passage model is designed based on real model of hydrogen compressor. Pressure boundary conditions are applied considering the real condition of operating system. The result shows pressure and turbulence kinetic energy are not distributed uniformly along the passage of the hydrogen compressing system. Path line or particles tracks help to demonstrate flow characteristics inside the passage. The existence of vortices and flow direction can be precisely predicted. Based on this result, the design improvement should be done. Consequently, development of the better hydrogen compressing system will be achieved.

  • PDF