• 제목/요약/키워드: System Safety Assessment

Search Result 1,772, Processing Time 0.029 seconds

PM2.5 Simulations for the Seoul Metropolitan Area: (II) Estimation of Self-Contributions and Emission-to-PM2.5 Conversion Rates for Each Source Category (수도권 초미세먼지 농도모사 : (II) 오염원별, 배출물질별 자체 기여도 및 전환율 산정)

  • Kim, Soontae;Bae, Changhan;Yoo, Chul;Kim, Byeong-Uk;Kim, Hyun Cheol;Moon, Nankyoung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.4
    • /
    • pp.377-392
    • /
    • 2017
  • A set of BFM (Brute Force Method) simulations with the CMAQ (Community Multiscale Air Quality) model were conducted in order to estimate self-contributions and conversion rates of PPM (Primary $PM_{2.5}$), $NO_x$, $SO_2$, $NH_3$, and VOC emissions to $PM_{2.5}$ concentrations over the SMA (Seoul Metropolitan Area). CAPSS (Clean Air Policy Support System) 2013 EI (emissions inventory) from the NIER (National Institute of Environmental Research) was used for the base and sensitivity simulations. SCCs (Source Classification Codes) in the EI were utilized to group the emissions into area, mobile, and point source categories. PPM and $PM_{2.5}$ precursor emissions from each source category were reduced by 50%. In turn, air quality was simulated with CMAQ during January, April, July, and October in 2014 for the BFM runs. In this study, seasonal variations of SMA $PM_{2.5}$ self-sensitivities to PPM, $SO_2$, and $NH_3$ emissions can be observed even when the seasonal emission rates are almost identical. For example, when the mobile PPM emissions from the SMA were 634 TPM (Tons Per Month) and 603 TPM in January and July, self-contributions of the emissions to monthly mean $PM_{2.5}$ were $2.7{\mu}g/m^3$ and $1.3{\mu}g/m^3$ for the months, respectively. Similarly, while $NH_3$ emissions from area sources were 4,169 TPM and 3,951 TPM in January and July, the self-contributions to monthly mean $PM_{2.5}$ for the months were $2.0{\mu}g/m^3$ and $4.4{\mu}g/m^3$, respectively. Meanwhile, emission-to-$PM_{2.5}$ conversion rates of precursors vary among source categories. For instance, the annual mean conversion rates of the SMA mobile, area, and point sources were 19.3, 10.8, and $6.6{\mu}g/m^3/10^6TPY$ for $SO_2$ emissions while those rates for PPM emissions were 268.6, 207.7, and 181.5 (${\mu}g/m^3/10^6TPY$), respectively, over the region. The results demonstrate that SMA $PM_{2.5}$ responses to the same amount of reduction in precursor emissions differ for source categories and in time (e.g. seasons), which is important when the cost-benefit analysis is conducted during air quality improvement planning. On the other hand, annual mean $PM_{2.5}$ sensitivities to the SMA $NO_x$ emissions remains still negative even after a 50% reduction in emission category which implies that more aggressive $NO_x$ reductions are required for the SMA to overcome '$NO_x$ disbenefit' under the base condition.

Role of the Inferior Thyroid Vein after Left Brachiocephalic Vein Division During Aortic Surgery

  • Park, Hyung-Ho;Kim, Bo-Young;Oh, Bong-Suk;Yang, Ki-Wan;Seo, Hong-Joo;Lim, Young-Hyuk;Kim, Jeong-Jung
    • Journal of Chest Surgery
    • /
    • v.35 no.7
    • /
    • pp.530-534
    • /
    • 2002
  • Background: In aortic surgery, division and ligation of the left brachiocephalic vein(LBV) may improve exposure of the aortic arch but controversy continues about the safety of this division and whether a divided vein should be reanastomosed after arch replacement was completed. The safety of LBV division and the fate of the left subclavian venous drainage after LBV division were studied. Material and Method: From November 1998 to January 2001, planned division and ligation of the LBV on the mid-line after median sternotomy was peformed in 10 patients during the aortic surgery with the consideration of local anatomy and distal aortic anastomosis. Assessment for upper extremity edema and neurologic symptoms, measurement of venous pressure in the right atrium and left internal jugular vein, and digital subtraction venography(DSV) of the left arm were made postoperatively. Result: In 10 patients there was improvement in access to the aortic arch for procedures on the ascending aorta or aortic arch. The mean age of patients was 62 years(range 24 to 70). Follow-up ranged from 3 weeks to 13 months. One patient died because of mediastinitis from methicilline-resistant staphylococcus aureus strain. All patients had edema on the left upper extremity, but resolved by the postoperative day 4. No patient had any residual edema or difficulty in using the left upper extremity during the entire follow-up period. No patient had postoperative stroke. Pressure difference between the right atrium and left internal jugular vein was peaked on the immediate postoperative period(mean peak pressure difference = 25mmHg), but gradually decreased, then plated by the postoperative day 4. In all DSV studies left subclavian vein flowed across the midline through the inferior thyroid venous plexus. Conclusion: We conclude that division of LBV is safe and reanastomosis is not necessary if inferior thyroid vein, which is developed as a main bridge connecting the left subclavian vein with right venous system, is preserved.

Glass Dissolution Rates From MCC-1 and Flow-Through Tests

  • Jeong, Seung-Young
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.257-258
    • /
    • 2004
  • The dose from radionuclides released from high-level radioactive waste (HLW) glasses as they corrode must be taken into account when assessing the performance of a disposal system. In the performance assessment (PA) calculations conducted for the proposed Yucca Mountain, Nevada, disposal system, the release of radionuclides is conservatively assumed to occur at the same rate the glass matrix dissolves. A simple model was developed to calculate the glass dissolution rate of HLW glasses in these PA calculations [1]. For the PA calculations that were conducted for Site Recommendation, it was necessary to identify ranges of parameter values that bounded the dissolution rates of the wide range of HLW glass compositions that will be disposed. The values and ranges of the model parameters for the pH and temperature dependencies were extracted from the results of SPFT, static leach tests, and Soxhlet tests available in the literature. Static leach tests were conducted with a range of glass compositions to measure values for the glass composition parameter. The glass dissolution rate depends on temperature, pH, and the compositions of the glass and solution, The dissolution rate is calculated using Eq. 1: $rate{\;}={\;}k_{o}10^{(ph){\eta})}{\cdot}e^{(-Ea/RT)}{\cdot}(1-Q/K){\;}+{\;}k_{long}$ where $k_{0},\;{\eta}$ and Eaare the parameters for glass composition, pH, $\eta$ and temperature dependence, respectively, and R is the gas constant. The term (1-Q/K) is the affinity term, where Q is the ion activity product of the solution and K is the pseudo-equilibrium constant for the glass. Values of the parameters $k_{0},\;{\eta}\;and\;E_{a}$ are the parameters for glass composition, pH, and temperature dependence, respectively, and R is the gas constant. The term (1-Q/C) is the affinity term, where Q is the ion activity product of the solution and K is the pseudo-equilibrium constant for the glass. Values of the parameters $k_0$, and Ea are determined under test conditions where the value of Q is maintained near zero, so that the value of the affinity term remains near 1. The dissolution rate under conditions in which the value of the affinity term is near 1 is referred to as the forward rate. This is the highest dissolution rate that can occur at a particular pH and temperature. The value of the parameter K is determined from experiments in which the value of the ion activity product approaches the value of K. This results in a decrease in the value of the affinity term and the dissolution rate. The highly dilute solutions required to measure the forward rate and extract values for $k_0$, $\eta$, and Ea can be maintained by conducting dynamic tests in which the test solution is removed from the reaction cell and replaced with fresh solution. In the single-pass flow-through (PFT) test method, this is done by continuously pumping the test solution through the reaction cell. Alternatively, static tests can be conducted with sufficient solution volume that the solution concentrations of dissolved glass components do not increase significantly during the test. Both the SPFT and static tests can ve conducted for a wide range of pH values and temperatures. Both static and SPFt tests have short-comings. the SPFT test requires analysis of several solutions (typically 6-10) at each of several flow rates to determine the glass dissolution rate at each pH and temperature. As will be shown, the rate measured in an SPFt test depends on the solution flow rate. The solutions in static tests will eventually become concentrated enough to affect the dissolution rate. In both the SPFt and static test methods. a compromise is required between the need to minimize the effects of dissolved components on the dissolution rate and the need to attain solution concentrations that are high enough to analyze. In the paper, we compare the results of static leach tests and SPFT tests conducted with simple 5-component glass to confirm the equivalence of SPFT tests and static tests conducted with pH buffer solutions. Tests were conducted over the range pH values that are most relevant for waste glass disssolution in a disposal system. The glass and temperature used in the tests were selected to allow direct comparison with SPFT tests conducted previously. The ability to measure parameter values with more than one test method and an understanding of how the rate measured in each test is affected by various test parameters provides added confidence to the measured values. The dissolution rate of a simple 5-component glass was measured at pH values of 6.2, 8.3, and 9.6 and $70^{\circ}C$ using static tests and single-pass flow-through (SPFT) tests. Similar rates were measured with the two methods. However, the measured rates are about 10X higher than the rates measured previously for a glass having the same composition using an SPFT test method. Differences are attributed to effects of the solution flow rate on the glass dissolution reate and how the specific surface area of crushed glass is estimated. This comparison indicates the need to standardize the SPFT test procedure.

  • PDF

The Implementation of a HACCP System through u-HACCP Application and the Verification of Microbial Quality Improvement in a Small Size Restaurant (소규모 외식업체용 IP-USN을 활용한 HACCP 시스템 적용 및 유효성 검증)

  • Lim, Tae-Hyeon;Choi, Jung-Hwa;Kang, Young-Jae;Kwak, Tong-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.3
    • /
    • pp.464-477
    • /
    • 2013
  • There is a great need to develop a training program proven to change behavior and improve knowledge. The purpose of this study was to evaluate employee hygiene knowledge, hygiene practice, and cleanliness, before and after HACCP system implementation at one small-size restaurant. The efficiency of the system was analyzed using time-temperature control after implementation of u-HACCP$^{(R)}$. The employee hygiene knowledge and practices showed a significant improvement (p<0.05) after HACCP system implementation. In non-heating processes, such as seasoned lettuce, controlling the sanitation of the cooking facility and the chlorination of raw ingredients were identified as the significant CCP. Sanitizing was an important CCP because total bacteria were reduced 2~4 log CFU/g after implementation of HACCP. In bean sprouts, microbial levels decreased from 4.20 logCFU/g to 3.26 logCFU/g. There were significant correlations between hygiene knowledge, practice, and microbiological contamination. First, personnel hygiene had a significant correlation with 'total food hygiene knowledge' scores (p<0.05). Second, total food hygiene practice scores had a significant correlation (p<0.05) with improved microbiological qualities of lettuce salad. Third, concerning the assessment of microbiological quality after 1 month, there were significant (p<0.05) improvements in times of heating, and the washing and division process. On the other hand, after 2 months, microbiological was maintained, although only two categories (division process and kitchen floor) were improved. This study also investigated time-temperature control by using ubiquitous sensor networks (USN) consisting of an ubi reader (CCP thermometer), an ubi manager (tablet PC), and application software (HACCP monitoring system). The result of the temperature control before and after USN showed better thermal management (accuracy, efficiency, consistency of time control). Based on the results, strict time-temperature control could be an effective method to prevent foodborne illness.

The assessment of Seoul City school sheriff system and developmental expansion plan - Around the righteousness proof of the security industry law application - (서울시 학교보안관 제도의 평가와 발전적 확대방안 - 경비업법 적용의 당위성 논증을 중심으로 -)

  • Lee, Sang-Hun
    • Korean Security Journal
    • /
    • no.29
    • /
    • pp.163-191
    • /
    • 2011
  • Recently, the problems in school violence did not stop on the crime between the members at the school and which developed into the invasion crime of the school caused by outsiders. The school is no more the safety zone from the crime. Particularly, in the case of the elementary school, because there are nearly no people who oppose to the outside attacker and can control this, it is the place where it is vulnerable to the invasion crime. The Metropolis of Seoul implements the School Sheriff system within the jurisdiction bureau, in the public elementary school. However, actually the School Sheriff business is being managed, never applying a rule in the Security Industry Law with the main content, that is the Security Industry Law application is excluded. Because the jurisdiction on the contract of Seoul City and operating company are run, the various issues is caused. First, since it is not being considered as a security business, the commercial liability insurance for security company has no chance to applicate when the operation company and the School Sheriff have related damage generation. So the security for the indemnification of loss of the victim is weak. Second, The task of the School Sheriff is ruled just by in the individual contracts. But it is insufficient with this thing. The related duties are required some supplement like a general rule application including the obligation of the guard in the security industry law. Third, the education of the School Sheriff needs to connect with the educational programme in the security industry law. The related professional education specially needed for the prevention of school violence ought to be reserved compensation. Forth, the citizens still demand the strengthening of police patrol for the surroundings of a school in spite of the result of Seoul City's public survey. Therefore, the active relation of cooperation with the police needs to be supported legally and institutionally with the Security Industry Law application. Fifthly, the success of the School Sheriff business can be more guaranteed with the supervision of the legal and institutional device like a the Security Industry Law application or police and all sorts of administrative execution's and etc.

  • PDF

A Study on Piracy Matters and Introduction of the Privately Contracted Armed Security Personnel on Board Ships (해적사건 대응을 위한 무장경비원제도 도입방안에 관한 연구)

  • Roh, Ho-Rae
    • Korean Security Journal
    • /
    • no.41
    • /
    • pp.293-326
    • /
    • 2014
  • Piracy is a worldwide issue, but the deteriorating security situation in the seas off Somalia, the Gulf of Aden and the wider Western Indian Ocean between 2005 and 2012 and in the increasing number of attacks in the Gulf of Guinea are a major problem. The depth of concern for the problem internationally is amply demonstrated by the levels of co-operation and coordination among naval and other forces from several countries that have assembled in the west Indian Ocean region and the Gulf of Aden to escort ships carrying humanitarian aid to Somalia and to protect vulnerable shipping. Notwithstanding this unprecedented effort, the vast sea area in which the pirates now operate makes it difficult to patrol and monitor effectively, particularly with the limited resources available. More resources, in the form of naval vessels and aircraft, are needed and at every opportunity the IMO encourages Member Governments to make greater efforts to provide the additional naval, aerial surveillance and other resources needed through every means possible. IMO provide interim guidance and recommendations to be taken into account when considering the use of PCASP(privately contracted armed security personnel) if and when a flag State determines that such a measure would be lawful and, following a full risk assessment, appropriate. The interim guidance and recommendations of IMO are not intended to endorse or institutionalize the use of armed guards. Therefore, they do not represent any fundamental change of policy by the Organization in this regard. It is for each flag State, individually, to decide whether or not PCASP should be authorized for use on board ships flying their flag. If a flag State decides to permit this practice, it is up to that State to determine the conditions under which authorization will be granted. Therefore, Korea should be introduced rationally PCASP for safe shipping. PCASP on board ships is much the same to special guard personnel of security services industry act. Act plan of Oceans and fisheries ministry on PCASP collides with special guard personnel system of National Police Agency. Rather than new law making, PCASP regukations have to be included in security services industry act. Management Agency of PCASP is to not Oceans and fisheries ministry, but Central Headquarters Korea Coast Guard of Public Safety and Security Ministry because of specialty and closely connection.

  • PDF

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Assessment of Microbiological Quality for Raw Materials and Cooked Foods in Elementary School Food Establishment (초등학교에 공급되는 급식용 식재료 및 조리식품의 미생물학적 품질평가)

  • Shin, Weon-Sun;Hong, Wan-Soo;Lee, Kyung-Eun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.3
    • /
    • pp.379-389
    • /
    • 2008
  • This study was conducted to assess the microbiological quality of raw and cooked foods served in the elementary school food service. Raw and cooked food samples were collected from 11 selected elementary schools in both June to July and September to October of 2005. Petrifilm plates were used to determine (in duplicate) total aerobic colony counts (PAC), Enterobacteriaceae (PE), coliform counts (PCC), and E. coli counts (PEC). Heavy contamination of Enterobacteriaceae (from 0.08 to 7.40 log CFU/g) and total coliform (0.50 to 6.52 log CFU/g) were observed in raw materials and cooked foods. Escherichia coli (E. coli) were detected in the sample of currant tomato (3.70 log CFU/g), sesame leaf (3.59 log CFU/g), dropwort (0.20 log CFU/g), crown daisy (3.15 log CFU/g), parsley (3.00 log CFU/g), peeled green onion (1.74 log CFU/g), frozen pork (0.65 log CFU/g), frozen beef (0.20 or 1.50 log CFU/g), chicken (1.78 log CFU/g), and young radish leaf seasoned with soybean paste (1.24 log CFU/g). Multiplex PCR system was used to determine the food-borne pathogens: Salmonella spp., Bacillus cereus (B. cereus), E. coli O157:H7, Staphylococcus aureus, Listeria monocytogenes (L. monocytogenes), Vibrio parahaemolyticus, Campylobacter jejuni (C. jejuni), Shigella spp., B. cereus was detected in 19 samples of raw materials and 8 samples of cooked foods. With regard to quantitative analysis, B. cereus counts exceeded 5.46, 3.48 and 1.79 log CFU/g in sesame leaf, peeled green onion and seasoned mungbean jelly, respectively. E. coli O157:H7 was detected on 2 samples of frozen beefs, and its biochemical characteristics of one beef sample was confirmed with API 20E kit (93.7%). L. monocytogenes was detected in fried rice paper dumpling, but the presumptive colonies were not detected onto the conventional plate. C. jejuni was detected in peeled & washed onion.

Development of tracer concentration analysis method using drone-based spatio-temporal hyperspectral image and RGB image (드론기반 시공간 초분광영상 및 RGB영상을 활용한 추적자 농도분석 기법 개발)

  • Gwon, Yeonghwa;Kim, Dongsu;You, Hojun;Han, Eunjin;Kwon, Siyoon;Kim, Youngdo
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.8
    • /
    • pp.623-634
    • /
    • 2022
  • Due to river maintenance projects such as the creation of hydrophilic areas around rivers and the Four Rivers Project, the flow characteristics of rivers are continuously changing, and the risk of water quality accidents due to the inflow of various pollutants is increasing. In the event of a water quality accident, it is necessary to minimize the effect on the downstream side by predicting the concentration and arrival time of pollutants in consideration of the flow characteristics of the river. In order to track the behavior of these pollutants, it is necessary to calculate the diffusion coefficient and dispersion coefficient for each section of the river. Among them, the dispersion coefficient is used to analyze the diffusion range of soluble pollutants. Existing experimental research cases for tracking the behavior of pollutants require a lot of manpower and cost, and it is difficult to obtain spatially high-resolution data due to limited equipment operation. Recently, research on tracking contaminants using RGB drones has been conducted, but RGB images also have a limitation in that spectral information is limitedly collected. In this study, to supplement the limitations of existing studies, a hyperspectral sensor was mounted on a remote sensing platform using a drone to collect temporally and spatially higher-resolution data than conventional contact measurement. Using the collected spatio-temporal hyperspectral images, the tracer concentration was calculated and the transverse dispersion coefficient was derived. It is expected that by overcoming the limitations of the drone platform through future research and upgrading the dispersion coefficient calculation technology, it will be possible to detect various pollutants leaking into the water system, and to detect changes in various water quality items and river factors.

Preliminary Results of Concurrent Chemotherapy and Radiation Therapy using High-dose-rate Brachytherapy for Cervical Cancer (자궁경부암에 항암화학요법과 동시 병용요법으로 외부 방사선조사와 고선량률 강내조사의 예비적 치료 결과)

  • Lee, Kyung-Ja;Lee, Ji-Hye;Lee, Re-Na;Suh, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.171-178
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: To determine the efficacy and safety of concurrent chemotherapy and radiation therapy with high-dose-rate brachytherapy for cervical cancer. $\underline{Materials\;and\;Methods}$: From January 2001 to December 2002, 30 patients with cervical cancer were treated with concurrent chemotherapy (cisplatin and 5-FU) and definitive radiation therapy. The median age was 58 (range $34{\sim}74$) year old. The pathology of the biopsy sections was squamous cell carcinoma in 29 patients and one was adenocarcinoma. The distribution to FIGO staging system was as follows: stage IB, 7 (23%); IIA, 3 (10%); IIB, 12 (40%); IIIA, 3 (10%); IIIB, 5 (17%). All patients received pelvic external beam irradiation (EBRT) to a total dose of $45{\sim}50.4\;Gy$ (median: 50.4 Gy) over $5{\sim}5.5$ weeks. Ir-192 HDR intracavitary brachytherapy (ICBT) was given after a total dose of 41.4 Gy. HDR-ICBT was performed twice a week, with a fraction point A dose of 4 Gy and median dose to point A was 28 Gy (range: $16{\sim}32\;Gy$) in 7 fractions. The median cumulative biologic effective dose (BED) at point A (EBRT+ICBT) was $88\;Gy_{10}$ (range: $77{\sim}94\;Gy_{10}$). The median cumulative BED at ICRU 38 reference point (EBRT+ICBT) was $131\;Gy_3$ (range: $122{\sim}140\;Gy_3$) at point A, $109\;Gy_3$ (range: $88{\sim}125\;Gy_3$) at the rectum and $111\;Gy_3$ (range: $91{\sim}123\;Gy_3$) at the urinary bladder. Cisplatin ($60\;mg/m^2$) and 5-FU ($1,000\;mg/m^2$) was administered intravenously at 3 weeks interval from the first day of radiation for median 5 (range: $2{\sim}6$) cycles. The assessment was performed at 1 month after completion of radiation therapy by clinical examination and CT scan. The median follow-up time was 36 months (range: $8{\sim}50$ months). $\underline{: The complete response rate after concurrent chemoradiation therapy was 93.3%. The 3-yr actuarial pelvic control rate was 87% and 3-yr actuarial overall survival and disease-free survival rate was 93% and 87%, respectively. The local failure rate was 13% and distant metastatic rate was 3.3%. The crude rate of minor hematologic complications (RTOG grade 1-2) occurred in 3 patients (10%) and one patient had suffered from severe leukopenia (RTOG grade 4) during concurrent treatment. Acute minor enterocolitis (RTOG grade 1-2) occurred in 11 patients (37%) and one patient (3%) was suffered from colon perforation during radiation therapy. Late colitis of RTOG grade 1 occurred in 5 patients (15%). Acute cystitis of RTOG grade 1 occurred in 12 patients (40%) and late cystitis of RTOG grade 2 occurred in one patient (3%). No treatment related death was seen. $\underline{Conclusion}$: The results of this study suggest that the concurrent chemoradiation therapy with HDR brachytherapy could be accepted as an effective and safe treatment for cervical cancer.