• 제목/요약/키워드: System Safety Analysis

검색결과 6,217건 처리시간 0.035초

치과장애인 환자의 외래마취 하 치과치료 귀가 후 전화추후 관리 분석 (Analysis of Telephone Follow-up Data of Out-patient Anesthesia for Dental Treatment of Disability Patients)

  • 김미선;서광석;이정만;김혜정;한진희;한희정;이은희;신순영;신터전;김현정;장주혜
    • 대한치과마취과학회지
    • /
    • 제12권2호
    • /
    • pp.93-97
    • /
    • 2012
  • Background: Some disabled patients show insufficient cooperation during dental treatment, and general anesthesia in an outpatient setting can be successfully administered. To minimize post-anesthetic complications is an essential issue, and strict discharge protocols are required for the safety of the patients. Post-anesthetic follow-ups using telephone calls can be applied to improve the quality of the outpatient care system. The authors evaluated the post-operative condition of patients after dental treatment under general anesthesia. Methods: Total 143 patients and their caregivers included in this study. The patients received general anesthesia for dental treatment in Seoul National University Dental Hospital, Clinic for Persons with Disabilities from July, 2011 to April, 2012. Telephone calls were given to the patients or their caregivers to collect information about the patients' systemic condition and anesthesia-related complications. Results: Among 131 patients with responses of telephone calls, 87 patients (66.4%) reported no discomfort, while 44 patients (33.6%) presented post-anesthetic complications. A total of 20 patients reported mild fever, 10 patients had vomiting, and 7 patients had sore throat. Other complications included nausea, fatigue, nasal bleeding, skin sore, and body rash. Among the patients with the history of epilepsy, 63.6% showed post-anesthetic discomfort or complication (P = 0.027, ${\chi}^2$ test). Conclusions: One third of dental patients who received general anesthesia due to insufficientcooperation complained discomfort after discharged from outpatient anesthetic care.

원전 증기발생기 와전류검사 장치의 전기적 특성 측정 (Electrical Characteristics Measurement of Eddy Current Testing Instrument for Steam Generator in NPP)

  • 이희종;조찬희;유현주;문균영;이태훈
    • 비파괴검사학회지
    • /
    • 제33권5호
    • /
    • pp.465-471
    • /
    • 2013
  • 원전 증기발생기는 원자로 냉각재 계통에서 발생한 열에너지를 터빈 계통의 주급수에 전달하여 터빈을 회전시키기 위한 증기를 생산하는 일종의 열교환기이다. 증기발생기 전열관의 손상은 증기발생기의 구조적 및 누설 건전성 유지 능력을 저해시키기 때문에 주기적으로 와전류검사를 수행하여 전열관의 건전성을 평가한다. 증기발생기 전열관의 건전성 평가는 보통 원자로 연료 재장전 기간 중에 수행된다. 현재 국내 증기발생기 전열관에 적용되는 와전류검사는 KEPIC 및 ASME 코드 요건에 따라 수행되며, 와전류검사 수행에 필요한 검사 시스템은 와전류검사 장치와 수집된 신호를 평가하기 위한 평가 프로그램으로 구성된다. 검사에 적용되는 와전류검사 시스템을 구성하는 핵심기기인 와전류검사 장치는 ASME 및 KEPIC 코드에서 총 고조파 왜곡율, 입출력 임피던스, 증폭기 직선성 및 안정성, 위상 직선성, 대역폭 및 복조필터 응답, 디지털 변환, 채널 간섭 등과 같은 전기적 특성을 측정하도록 규정하고 있다. 이에 따라 본 논문에서는 국내 최초로 개발한 원전 증기발생기 와전류검사 장치의 전기적 특성 측정을 위한 ASME 및 KEPIC 코드 요건을 설명하고, 이 요건에 따른 증기발생기 와전류검사 장치의 전기적 특성의 측정 결과를 제시하였다.

N2 Method를 이용한 RC 중간모멘트 연성골조의 반응수정계수 및 내진성능 평가 (Estimation of R-factor and Seismic Performance for RC IMRFs using N2 Method)

  • 윤정배;이철호;최정욱;송진규
    • 한국지진공학회논문집
    • /
    • 제6권6호
    • /
    • pp.33-39
    • /
    • 2002
  • 반응수정계수는 구조물의 비탄성 거동을 설계에 반영하고 설계지진력 산정시 설계강도를 탄성범위 이내로 저감시키기 위한 목적으로 사용하고 있다. 그러나 설계코드에서 채택하고 있는 반응수정계수는 과거의 지진피해로부터 관찰된 보편적 구조성능에 기인한 경험치이므로, 주기에 따른 동적성능과 구조 시스템의 구성에 따른 내진성능을 정확히 대변하지 못하고 있다. 본 연구에서는 중간모멘트 연성골조를 대상으로 N2 Method를 이용하여 반응수정계수와 내진성능을 평가하였으며, 그 결과를 미국의 IBC 2000 코드와 비교하여 이론적 타당성을 검증하였다. 해석결과 코드에 제시된 반응수정계수와 잘 부합되는 것으로 나타났으나, 동일한 구조시스템의 경우에도 주기에 따라 비교적 큰 차이를 보였다. 성능목표에 따른 사용성 기준을 설정하여 IDI를 평가한 결과, 설계지진에 대한 성능목표가 건물에 대한 내진성능을 대변하기는 어려우며 PBD(Performance Based Design)에 의거한 합리적인 접근이 필요한 것으로 판단된다.

HA-Dex 융복합 하이드로겔 패치의 아토피 치유 능력에 대한 물리적 특성 및 생체 적합성 평가 (Evaluation of Physical Properties and Biocompatibility of HA-Dex Fusion Hydrogel Patch for Atopic Healing Ability)

  • 홍경식;최정연;최진현
    • 대한화장품학회지
    • /
    • 제46권3호
    • /
    • pp.219-229
    • /
    • 2020
  • 최근, 아토피 피부염은 피부 자극에 민감하므로 피부 자극을 최소화하면서도, 특정한 국소 부위에 대한 점착력과 흡수력을 효과적으로 발휘할 수 있으며 적절한 약물 방출을 거동할 수 있는 패치 개발이 우선시 되어야 한다고 제안되기도 하였다. 따라서 본 연구는 피부 자극을 최소화하고 특정 부위에 효과적으로 접착 및 흡수 할 수 있는 하이드로겔 패치를 개발코자 하였다. 아토피 패치는 동결 건조법을 이용하여 고흡수성 하이드로겔 시트를 제형화 하였다. 인간각질세포(HaCaT cells) 및 섬유아세포(L929 cells) 사용하여 세포 안정성을 수행하였다. 물리적 성질을 조사하고자 FT-IR, FE-SEM, 다공성 분석, 팽윤성 거동을 조사 하였다. 그 결과, 새롭게 제조된 HA-Dex 하이드로겔 패치는 생체 적합성 및 물리적 평가에 의해 입증하였다. 또한 제조된 하이드로겔 패치는 충분한 수분 흡수력과 아토피성 피부의 가려움증을 완화시킬 수 있으며, 향후 아토피 성 피부염 치료에 다양한 약물 전달 제품에 적용될 수 있을 것으로 기대된다.

Äspö 원형 처분장에 대한 열-수리-역학적 모델링 연구: 열적 거동 해석 (Thermal-hydro-mechanical Modelling for an Äspö prototype repository: analysis of thermal behavior)

  • 이재완;;최희주
    • 터널과지하공간
    • /
    • 제23권5호
    • /
    • pp.372-382
    • /
    • 2013
  • 고준위폐기물처분장에 대한 열-수리-역학적 거동 모델링은 처분장의 성능 및 안전성 평가를 위해서 선행되어야 할 중요한 연구과제이다. 본 연구에서는 $\ddot{A}$sp$\ddot{o}$ 원형처분장의 열적 거동을 해석하고, 현장 실험데이터와의 비교를 통해 모델 계산결과의 타당성을 검증하였다. 모델 시뮬레이션에서는 처분공과 처분터널 및 그 주변 암반에 대한 온도분포를 분석하였다. 현장 실험데이터와의 비교는 처분공 DH-6를 대상으로 수행하였다. 그 결과 모델 계산치는 측정위치에 따라 실험치 보다 약 2-$5^{\circ}C$ 정도 높은 온도값을 보였으나, 온도변이 곡선은 비슷한 패턴을 보여 주었다. 실험치와 모델 계산치의 이러한 차이는 모델에 의한 열적거동 해석에서 암반을 제외한 완충재, 벤토나이트 펠렛, 뒷채움재 내의 수리학적 및 역학적 거동을 고려하지 않았기 때문으로 판단되었다.

Safety of Laparoscopic Sentinel Basin Dissection in Patients with Gastric Cancer: an Analysis from the SENORITA Prospective Multicenter Quality Control Trial

  • An, Ji Yeong;Min, Jae Seok;Lee, Young Joon;Jeong, Sang Ho;Hur, Hoon;Han, Sang Uk;Hyung, Woo Jin;Cho, Gyu Seok;Jeong, Gui Ae;Jeong, Oh;Park, Young Kyu;Jung, Mi Ran;Park, Ji Yeon;Kim, Young Woo;Yoon, Hong Man;Eom, Bang Wool;Ryu, Keun Won;Sentinel Node Oriented Tailored Approach (SENORITA) Study Group
    • Journal of Gastric Cancer
    • /
    • 제18권1호
    • /
    • pp.30-36
    • /
    • 2018
  • Purpose: We investigated complications after laparoscopic sentinel basin dissection (SBD) for patients with gastric cancer who were enrolled in a quality control study, prior to the phase III trial of sentinel lymph node navigation surgery (SNNS). Materials and Methods: We analyzed prospective data from a Korean multicenter prerequisite quality control trial of laparoscopic SBD for gastric cancer and assessed procedure-related and surgical complications. All complications were classified according to the Clavien-Dindo Classification (CDC) system and were compared with the results of the previously published SNNS trial. Results: Among the 108 eligible patients who were enrolled in the quality control trial, 8 (7.4%) experienced complications during the early postoperative period. One patient with gastric resection-related duodenal stump leakage recovered after percutaneous drainage (grade IIIa in CDC). The other postoperative complications were mild and patients recovered with supportive care. No complications were directly related to the laparoscopic SBD procedure or tracer usage, and there were no mortalities. The laparoscopic SBD complication rates and patterns that were observed in this study were comparable to those of a previously reported trial. Conclusions: The results of our prospective, multicenter quality control trial demonstrate that laparoscopic SBD is a safe procedure during SNNS for gastric cancer.

수중 콘크리트 구조물의 수심별 강도 추정에 관한 연구 (A Study on Compressive Strength Estimation of Underwater Concrete Structures According to Water Depths)

  • 이지성;한상훈;박승희
    • 대한토목학회논문집
    • /
    • 제36권3호
    • /
    • pp.341-348
    • /
    • 2016
  • 기존의 항만구조물은 사용연수가 증가함에 따라 노후화가 진행되고 있으며 바닷물의 침식 등에 의한 콘크리트 염해 등으로 인해 내구성이 저하되고 있다. 더불어 수출입 증가에 따른 항만시설의 확충과 해상구조물의 수요가 있을 것으로 판단된다. 따라서 본 연구에서는 항만구조물을 비롯한 수중 콘크리트 구조물의 효율적인 유지관리를 위해 수중화된 슈미트해머와 초음파센서의 현장 실험결과를 통해 수중 비파괴검사 장비의 현장 적용성을 검증하고, 수심별 강도 추정식을 도출하였다. 다중회귀분석을 통해 도출된 복합 강도 추정식은 수심에 대한 보정이 이루어져 있어 추후 수중에서의 활용성이 매우 높을 것으로 기대된다. 또한, 향후 활발히 개발되고 있는 수중 ROV에 본 연구에서 수중화한 슈미트해머와 초음파센서를 탑재시켜 수중 콘크리트 구조물의 진단에 활용한다면 신뢰도 높은 수중 콘크리트 구조물의 상태진단과 자동화를 통한 상시감시를 이루어 온라인상으로도 모니터링이 가능한 유비쿼터스 개념의 통합된 비파괴검사 시스템 구축이 가능할 것으로 판단된다.

이중화된 진동 정보 판별 기법과 고장 파형 분류를 이용한 선박 엔진의 고장 감지 (Defect Detection of Ship Engine using duplicated checking of vibration-data-distinction Method and Classification of fault-wave)

  • 이양민;이광용;배승현;신일식;장휘;이재기
    • 한국항해항만학회지
    • /
    • 제33권10호
    • /
    • pp.671-678
    • /
    • 2009
  • 현재 진동 정보를 통해 기계 설비의 상태나 고장 유무를 판단하는 연구들이 다수 진행 중에 있는데, 대부분의 연구에서는 설비에 대한 진동을 모니터링하거나 고장 유무를 판별하여 사용자에게 알리는 수준이다. 본 논문에서는 진동 정보 적용 대상을 선박으로 정하고, 진동에 의한 고장 진단과 판별을 보다 정교하게 수행하는 선박 엔진 감지 기법과 시스템을 제안하였다. 일차적으로 이중화된 진동 정보 판별 기법을 적용하여 진동 정보를 확인한 다음에 고장 유무를 검사한다. 만일 고장이 발생한 경우에는 적분을 이용하여 고장 진동 파형에 대한 넓이를 기준으로 어떤 유형의 고장인지를 판별할 수 있는 기법을 적용하였다. 또한 선박의 진동 경향 분석과 엔진 안전 보존을 목적으로 진동 정보를 데이터베이스에 저장하고 추적할 수 있도록 시스템을 구현하였다. 제안 시스템을 선박 엔진의 고장 판별 유무와 고장 진동 파형 감별 인자에 대해 실험을 수행한 결과 고장 판별은 약 98% 정확성을 가졌고 고장 진동 파형 감별에서는 약 72% 정확성을 가졌다.

재난대응 구호주거 성능지표 개발을 위한 기초연구 (A Basic Study of Development of Post-disaster Refugees Housing Performance Index)

  • 남혜령;이원학;강수민;김성태;조영준;이병연
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.744-754
    • /
    • 2017
  • 본 연구는 구호주거 성능 기준 및 개발의 기반을 다지기 위해 구호주거 성능지표 체계를 개발하고 지표의 도입 방안을 제시하는 것을 목표로 전문가 설문을 통한 계층적 분석 기법(Analytic Hierarchy Process)을 진행하였다. 구호주거 성능지표 체계를 구축하기 위하여 구호주거를 항구적 주택이 마련되기 전까지 일정 기간 사용되는 중장기 임시 거주 시설로 정의하고 안전성, 신속성, 재사용성, 거주성, 경제성을 주요 성능 요소로 도출하였고, 주요 성능 요소와 건축물의 전 생애주기를 연계하여 계층화된 성능지표 체계를 구축하였다. 개발된 구호주거 성능지표 체계의 항목별 중요도를 계층적 분석 기법에 따라 정량적으로 도출하였다. 마지막으로, 중요도 분석 결과를 바탕으로 종합 가중치 1-10 순위의 성능 기준과 각 범주별 1 순위의 성능 기준인 총 14 개의 성능 기준을 필수 성능 기준(반드시 충족), 그 외는 권장 성능 기준(선택적 충족)으로 분류하여 구호주거 개발의 모든 단계를 고려한 성능지표를 구축하였다. 추후 구호주거 성능지표의 완성으로 재난에 의해 발생하는 이재민의 안정적인 거주 보장과 빠른 일상복귀를 도모할 수 있을 것으로 기대된다.

가정 내 낙상으로 인한 아동 손상의 유발 환경 인자에 관한 예비연구 (A Pilot Study on Environmental Factors Contributing to Childhood Home Slip-Down Injuries)

  • 유정민;서민후;김원영;김원;임경수
    • Journal of Trauma and Injury
    • /
    • 제22권1호
    • /
    • pp.51-56
    • /
    • 2009
  • Purpose: The purpose of this study was to investigate environmental factors contributing to childhood home slip-down injuries. Methods: Among a total of 2,812 injured children in our Customer Injury Surveillance System (CISS), we performed a prospective study on 262 children with home slip-down injuries who visited the pediatric emergency department of Asan Medical Center between March 2008 and February 2009. We made a frequency analysis on parameters such as activities just before the accident, the presence of any obstacles or lubricant materials, specific home place in the home where the injuries occurred, flooring materials on which the slip-down happened, additional objects hit after slip down, the site and kind of injury, the duration of therapy, and the disposition. Results: Walking was the most common activity just before the injury. Because rooms and bathrooms were most common places in the home for slip down injuries, laminated papers/ vinyl floor coverings and tiles were the most common flooring materials used in the places where the injuries occured. Most commonly, no obstacles caused the children to slip down, but the furniture, stairs, doorsills, wetness, or soapy fluid followed after that. Over half of the children who slipped (58%) also collided with other than the floor itself after the slip-down, most common objects hit were the edges of the furniture, and doorsills, followed by stairways. The head and neck were the most commonly injured sites, and a laceration was the most common kind of injury. Most children needed less than 1 week of therapy, only 4 children (1.53%) admitted. There were no mortalities. Conclusion: The environmental factors contributing to slip-down injuries were the bathroom, laminated papers/vinyl floors, the furniture, stairs, doorsills, and wetness or soapy fluid. Especially, the furniture, stairs, and doorsills can be both primary obstacles and secondary collision objects. For the safety of our children, we must consider these factors on housing, when decorating or remodeling our house.