• Title/Summary/Keyword: System Recovery

Search Result 3,169, Processing Time 0.032 seconds

Performance Analysis of Clock Recovery for OFDM/QPSK-DMR System Using Band Limited-Pulse Shaping Filter (대역 제한 필터를 이용하는 OFDM/QPSK-DMR 시스템을 위한 클럭 복조기의 성능 분석)

  • 안준배;양희진;강희곡;오창헌;조성준
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.245-249
    • /
    • 2004
  • In this paper, we have proposed a clock recovery algorithm of Orthogonal Frequency Division Multiplexing/Quadrature Phase Shift Keying Modulation-Digital Microwave Radio(OFDM/QPSK-DMR) system using Band Limited-Pulse Shaping Filter(BL-PSF) and compared the clock phase error variance of OFDM/QPSK-DMR system with that of single carrier DMR system. The OFDM/QPSK-DMR system using windowing method requires training sequence or Cyclic Prefix (CP) to synchronize the clock phase of received signal. But transmit efficient is increased in our proposed DMR system because of no using redundant data such as training sequence or CP. The proposed clock recovery algorithm is simply realized in the OFDM/QPSK-DMR system using BL-PSF. The simulation results confirm that the proposed clock recovery algorithm has the same clock phase error variance performance in a single carrier DR system under Additive White Gaussian Noise(AWGN) environment.

Enhancement of the energy efficiency of hydrogen SOFC system by integrated cold energy utilization and waste heat recovery method

  • Nguyen Quoc Huy;Duong Phan Anh;Ryu Bo Rim;Lee Jin Uk;Kang Ho Keun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2022.11a
    • /
    • pp.160-161
    • /
    • 2022
  • Hydrogen is bridge fuel with high energy content and environmentally friendly to satisfy the stringent IMO regulation relating to greenhouse gas (GHG) emissions. There is growing interest in hydrogen in numerous nations and regions illustrated by an extensive range of research and development in technology. Regarding maritime applications, researchers have recognized the utilization of hydrogen as a fuel for fuel cells, a device that converts the chemical energy of the fuel to electrical energy. Solid oxide fuel cell (SOFC), with high working temperature, is easy to combine with the waste heat recovery cycles/devices to increase output power and thermodynamic performances as well. Furthermore, the cold energy from liquid hydrogen supplied to SOFC can also be used to generate more power. In this study, we proposed a SOFC integrated system with the idea of combining the waste heat recovery from the SOFC exhaust stream and cold energy utilization from LH2. The designation is aimed to target small-scale vessel which uses electric propulsion for short distances voyage.

  • PDF

An Efficient Recovery System for Spatial Main Memory DBMS (공간 메인 메모리 DBMS를 위한 효율적인 회복 시스템)

  • Kim, Joung-Joon;Ju, Sung-Wan;Kang, Hong-Koo;Hong, Dong-Sook;Han, Ki-Joon
    • Journal of Korea Spatial Information System Society
    • /
    • v.8 no.3
    • /
    • pp.1-14
    • /
    • 2006
  • Recently, to efficiently support the real-time requirements of LBS and Telematics services, interest in the spatial main memory DBMS is rising. In the spatial main memory DBMS, because all spatial data can be lost when the system failure happens, the recovery system is very important for the stability of the database. Especially, disk I/O in executing the log and the checkpoint becomes the bottleneck of letting down the total system performance. Therefore, it is urgently necessary to research about the recovery system to reduce disk I/O in the spatial main memory DBMS. In this paper, we study an efficient recovery system for the spatial main memory DBMS. First, the pre-commit log method is used for the decrement of disk I/O and the improvement of transaction concurrency. In addition, we propose the fuzzy-shadow checkpoint method for the recovery system of the spatial main memory DBMS. This method can solve the problem of duplicated disk I/O on the same page of the existing fuzzy-pingpong checkpoint method for the improvement of the whole system performance. Finally, we also report the experimental results confirming the benefit of the proposed recovery system.

  • PDF

Heat Exchanging Performance as Affected by Arrangement of Heat Exchanging Pipe (열회수장치의 열교환 파이프배치 형식별 열교환 성능)

  • 윤용철;강종국;서원명
    • Journal of Bio-Environment Control
    • /
    • v.11 no.3
    • /
    • pp.101-107
    • /
    • 2002
  • This study was carried out to improve the performance of heat recovery device attached to exhaust gas flue connected to combustion chamber of greenhouse heating system. Three different units were prepared far the comparison of heat recovery performance; A-type is exactly the same with the typical one fabricated for previous study of analyzing heat recovery performance in greenhouse heating system, other two types (B-type and C-type) modified from the control unit are different in the aspects of airflow direction (U-turn airflow) and pipe arrangement. The results are summarized as follows ; 1. In the case of Type-A, when considering the initial cost and current electricity fee required for system operation, it was expected that one or two years at most would be enough to return the whole cost invested. 2. Type-B and Type-C, basically different with Type-A in the aspect of airflow pattern, are not sensitive to the change of blower capacity with higher than 25m$^3$.min$^{-1}$ . Therefore, heat recovery performance was not improved so significantly with the increment of blower capacity. This was assumed to be that air flow resistance in high air capacity reduced the heat exchange rate as well. Never the less, compared with control unit, resultant heat recovery rate of Type-B and Type-C was improved by about 5% and 13%, respectively 3. Desirable blower capacity of these heat recovery units experimented were expected to be about 25m$^3$.min$^{-1}$ , and at the proper blower capacity, U-turn airflow units showed better heat recovery performance than control unit. But, without regard to the type of heat recovery unit, it was recommended that comprehensive consideration of system's physical factors such as pipe arrangement density, unit pipe length and pipe thickness, etc., was required for the optimization of heat recovery system in the aspects of not only energy conservation but economic system design.

Research on Performance of Large Rotor-type Heat Recovery Exchanger using CFD Analysis on Surface Corrugation (요철형상의 CFD 해석을 통한 대용량 로타형 폐열회수열교환기 성능에 관한 연구)

  • Kim, Dong-Gyu;Ha, Byeong-Yong;Kim, Kun-Oh;Kum, Jong-Soo;Jeong, Seok-Kwon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.12
    • /
    • pp.875-880
    • /
    • 2012
  • The field of the large volume heat exchanger for wasted heat recovery ventilation system is being expanded enormously seeing as the fact that the quantity of reducing energies are huge due to the large volume heat exchanger for wasted heat recovery system at large buildings and factories, which consume large amount of energies while it has been arising huge amount of losses in Korea because of the lack of technology. To develop large volume waste heat recovery heat exchanger, rotor type heat exchanger was simulated for the surface corrugation. Based on the simulation results produced $30,000m^3/h$ grade waste heat recovery, heat exchanger was performed for the actual experiment. In addition, performance tests exceed the capacity of a large waste heat recovery heat exchanger performance test methods proposed.

Fuzzy Technique based Chopper Control for Slip Energy Recovery System with Twelve-Pulse Converter

  • Tunyasrirut, S.;Ngamwiwit, J.;Furuya, T.;Yamamoto, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.509-514
    • /
    • 2004
  • This paper introduces the modified slip energy recovery system in order to improve its power factor and to reduce harmonics of line current waveforms. Twelve pulse line commutated converter with the chopper type IGBT is applied where the chopper is applied across the DC terminal and the chopped DC is fed to the converter operating as an inverter and then passed through the wye-wye and delta-wye transformer circuit. This scheme leads to be able to adjust the speed of the motor by the duty cycle of the chopper operating in PWM mode. The fuzzy logic controller is also introduced to the modified slip energy recovery system for keeping the motor speed to be constant when the load varies. The experimental results in testing the 0.22 kW wound rotor induction motor from no-load condition to rated condition show the effectiveness of the proposed control scheme.

  • PDF

A Study on Public Key Cryptographic Authentication System Providing Key Distribution and Recovery in the Initial Authentication (초기인증에서 키 분배 및 복구를 지원하는 공개키 암호 인증시스템에 관한 연구)

  • Shin Kwang-Cheul;Cho Sung-Je
    • Journal of Internet Computing and Services
    • /
    • v.7 no.3
    • /
    • pp.83-91
    • /
    • 2006
  • In this paper, we improved a cryptography system model based on the secure initial authentication public key with PKINIT of authentication and key recovery protocol. It is applied to all fields of cryptography system using certificate. This study presents two mechanisms to authenticate between member users. The first mechanism is initial authentication and distribution of session key by public key cryptography based on certificate between entity and server, and the second mechanism is a key recovery support protocol considering loss of session key in the secure communication between application servers.

  • PDF

A Study on the Planning Elements for Ecological Restoration of Urban Stream through Present Condition Analysis - focused on the Yeocheon and the Mugeo stream - (현황분석을 통한 도시 소하천의 생태하천 계획요소에 관한 연구 -울산광역시 무거.여천천을 중심으로-)

  • Kim, Seong Cheol;Lee, Cheol Yeong
    • Journal of Environmental Science International
    • /
    • v.13 no.9
    • /
    • pp.747-757
    • /
    • 2004
  • The objectives of this study were to investigate the physical, chemical, and structural characteristics of the stream, especially Mugeo and Yeochon which are being changed to ecological stream by Ulsan city, and to acquire the considerations such as the planning element and plan criteria of the streams for making ecological stream system. Water quality, water quantity, vegetation, in stream structures and facilities, and land usage of the streams were investigated and the build up capabilities of ecological stream for the two streams were also analyzed. Planning elements for restoration to ecological stream included physical and biological purification methods in water quality, short term water acquire alternatives in water quantity, and vegetation recovery plan and improvement of habitation environment in ecological system, respectively. Planing elements in physical structures and facilities also included recovery of concrete levee and removal and recovery of covered channel.

Design of an Aquifer Thermal Energy Storage System(II) : Thermal Analysis (지하대수층을 이용한 축열시스템의 설계(II) : 열해석)

  • Lee, K.S.;Lee, T.H.;Song, Y.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.315-324
    • /
    • 1994
  • The energy recovery efficiency(ERE) of an aquifer thermal energy storage system was calculated using curvilinear coordinate. The results of the calculation were compared with the experimental results, and agreed within 11% of the discrepancy. The variation of ERE was investigated as a function of the underground water natural velocity, the amount of the stored energy, and period of the energy recovery. The slower the natural velocity and shorter the recovery period, the higher ERE was yielded. Also it was found that increase in the amount of energy storage yields higher ERE, and carries out less influential ERE to the natural velocity. Reiterative usage of the aquifer as a thermal storage tends to gradually increase ERE. The result of this study implements that the aquifer thermal energy storage system is suitable for large cooling/heating loads, such as district cooling/heating.

  • PDF

DES Approach Failure Recovery of Pump-valve System (펌프-밸브 시스템의 DES 접근론적 Failure Recovery)

  • Son, H.I.;Kim, K.W.;Lee, S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.647-650
    • /
    • 2000
  • For the failure diagnosis of industrial system like various manufacturing systems, power plants and etc, many failure diagnosis approaches are considered. Here we are focus on the DES approach for failure diagnosis. We treats of failure recovery problem that is euly not mentioned in DES approach. The procedure to design a recoverable diagnoser is presented. And the recoverability, necessary and sufficient condition fur recoverability are defined. Then we make the high-level diagnoser to reduce the state size of recoverable diagnsoer. Finally, a pump-valve system example is presented.

  • PDF