Browse > Article
http://dx.doi.org/10.6110/KJACR.2012.24.12.875

Research on Performance of Large Rotor-type Heat Recovery Exchanger using CFD Analysis on Surface Corrugation  

Kim, Dong-Gyu (Department of Refrigeration and Air conditioning Engineering, Pukyung National University)
Ha, Byeong-Yong (Korea District Heating Corp.)
Kim, Kun-Oh (Seobun Engineering Co., Ltd.)
Kum, Jong-Soo (Department of Refrigeration and Air conditioning Engineering, Pukyung National University)
Jeong, Seok-Kwon (Department of Refrigeration and Air conditioning Engineering, Pukyung National University)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.24, no.12, 2012 , pp. 875-880 More about this Journal
Abstract
The field of the large volume heat exchanger for wasted heat recovery ventilation system is being expanded enormously seeing as the fact that the quantity of reducing energies are huge due to the large volume heat exchanger for wasted heat recovery system at large buildings and factories, which consume large amount of energies while it has been arising huge amount of losses in Korea because of the lack of technology. To develop large volume waste heat recovery heat exchanger, rotor type heat exchanger was simulated for the surface corrugation. Based on the simulation results produced $30,000m^3/h$ grade waste heat recovery, heat exchanger was performed for the actual experiment. In addition, performance tests exceed the capacity of a large waste heat recovery heat exchanger performance test methods proposed.
Keywords
Waste heat recovery; Temperature efficiency; Heat exchange efficiency; Computational fluid dynamics;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Yoo, S. Y., Kim, J. H., Chung, M. H., and Jie, M. S., 2008, A Study on the Performance Prediction of Paper Heat Exchanger for Exhaust Heat Recovery, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 17, No. 6, pp. 372-380.   과학기술학회마을
2 Ha, B. Y., Im, H. S., Kim, D. G., Kum, J. S., Jeong, S. K., Chung, Y. H., Kim, G. H., and Myeong, J. P., 2009, Experiment Results of 30,000 CMH class Heat Exchangers for Wasted Heat Recovery in Winter, Proceedings of the SAREK Summer Annual Conference, pp. 83-86.   과학기술학회마을
3 Ha, B. Y., Im, H. S., Kim, D. G., Kum, J. S., Jeong, S. K., Chung, Y. H., Kim, G. H., and Myeong, J. P., Experiment Results of 30,000 CMH class Heat Exchangers for Wasted Heat Recovery in Summer, Proceedings of the SAREK Winter Annual Conference, pp. 381- 384.
4 Seo Bun Engineering, 2009, Development of high value-added heat recovery ventilation system, The Ministry of Knowledge Economy.
5 Jeong, M. H., 2009, Development of energy-saving ventilation system using a plastic heat exchanger, Technical Intelligence in DAERIM Vol. 89, pp. 39-50.
6 Choi, J. Y., International standardization of heat recovery ventilators, Korea Testing Laboratory.
7 ANSI/ASHRAE Standard 84-2008.
8 ARI, 2005, Standard.
9 JIS B 8620(2003 edition).
10 KS B 6879, Heat recovery ventilators, Korea Industrial Standards Commission.