• Title/Summary/Keyword: System Operation

Search Result 20,270, Processing Time 0.046 seconds

Improving Flexibility of External Data Exchange in Count-fire Operation System by Adapting Dynamic Parser Software (동적 구문처리기 소프트웨어 적용을 통한 대화력전 수행체계 연동의 유연성 향상 방안)

  • Hong, Won-Eui
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.51-56
    • /
    • 2008
  • The counter-fire operation system performs its mission exchanging information with other related systems such as command & control systems and military information systems. In the process of exchanging information, the counter-fire operation system uses a type of data message which contains exchange data information in the format of KMTF. The requirement of data exchange of count-fire operation will continue to evolve. But the EDX(External Data eXchange) configuration item of the current counter-fire operation system can not effectively cope with the variation of data exchange requirements due to its fixed software structure. In the paper, a solution for improving flexibility of external data exchange in counter-fire operation system is proposed.

A Multiagent System for Microgrid Operation in the Grid-interconnected Mode

  • Kim, Hak-Man;Kinoshita, Tetsuo
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.246-254
    • /
    • 2010
  • This paper presents a multiagent system for microgrid operation in the grid-interconnected mode. An energy market environment with generation competition is adopted for microgrid operation in order to guarantee autonomous participation and meet the requirements of participants in the microgrid. The modified Contract Net Protocol (CNP) is used as a protocol for interactions among agents. The multiagent system for microgrid operation based on the modified CNP and the energy market environment is designed and implemented. To verify the feasibility of the suggested multiagent system, experiments on three operation conditions are carried out.

A Study on the Efficiency of Energy Storage System Applied to the Power Traction System of DC Electric Railway (직류전기철도에서 운행시격에 따른 에너지저장장치의 효율에 관한 연구)

  • Kim, Sung-Dae;Choi, Kyu-Hyoung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.754-760
    • /
    • 2011
  • In the DC traction system, a large load current of electric railcar leads to a voltage drop when a vehicle starts, and the regenerative power generated by brake system increases the catenary voltage. To minimize the voltage fluctuation during the train operation and make use of the regenerative power, several types of energy storage systems are being studied. The energy storage system that is being recently introduced consists of the supercapacitors for energy storage and the bi-direction DC/DC converter for charge/discharge control. The efficiency of the energy storage system depends on the train operation pattern. In this paper, the operation efficiency of the energy storage system was quantitatively analyzed via simulation study taking consideration of the train operation patterns. The simulation was conducted changing the headway of trains with the energy storage system that uses the bi-direction DC/DC converter and supercapacitor. The simulation results showed that the operation efficiency of the energy storage system increases as the headway increase.

  • PDF

Development of the Quality of Service management program using the fourth generation language (제4세대 언어를 사용한 서비스품질 관리 프로그램의 개발)

  • 박순달;정호연;서정대;김태호
    • Korean Management Science Review
    • /
    • v.9 no.1
    • /
    • pp.41-52
    • /
    • 1992
  • The QOS(Quality of Service) recognized by the customer will become the most important thing under the competitive telecommunications market. Korea Telecom is going to develop many system to manage the telecommunication network, to improve the level of QOS, and to increase the revenue. Operation and Maintenance Adiministration System is one of the systems developed to meet those purposes efficiently. This system gathers qualities data from telephone offices or operation centers and analyze the results of QOS improvement activities and evaluate overall QOS. And also system makes it possible to improve the cost/effectiveness of operation and maintenance of telecommunication network. Operation and Maintenance Administration System has four functional modules, i.e., the user interface module, the database management module, the QOS management module, and the database conversion module. The purpose of this study is to develop the QOS management program, one of the four functional modules of the system,using FOCUS 4GL/DBMS. Since Operation and Maintenance Administration System is developed using FOCUS 4GL, every user can handle and maintain the system very easily and reduce system backlogs.

  • PDF

Operation Scheduling System for Hull Block Fabrication in Shipbuilding using Genetic Algorithm (유전 알고리즘을 이용한 선각 가공 작업일정계획 시스템의 개발에 관한 연구)

  • Cho, Kyu-Kab;Kim, Young-Goo;Ryu, Kwang-Ryel;Hwang, Jun-Ha;Choi, Hyung-Rim
    • IE interfaces
    • /
    • v.11 no.3
    • /
    • pp.115-128
    • /
    • 1998
  • This paper presents a development of operation scheduling and reactive operation scheduling system for hull fabrication. The methodology for implementing operation scheduling system is HHGA(Hierarchical Hybrid Genetic Algorithm) which exploits both the global perspective of the genetic algorithm and the rapid convergence of the heuristic search for operation scheduling. The methodology for the reactive operation scheduling is the revised HHGA which consists of manual schedule editor for occurrence of exceptional events and the revised scheduling method used in operation scheduling. As the results of experiment, it has been confirmed that HHGA is able to search good operation scheduling within reasonable time, and the revised HHGA is able to search load-balanced reactive operation scheduling with minimum changes of initial operation schedule within short period of time.

  • PDF

A Study on Development of Operation Evaluation Index for Safety Management System Using AHP (AHP를 이용한 안전관리체제 운영평가지표 개발에 관한 연구)

  • Noh, Chang-Kyun;Lee, Jong-In;Shin, Chul-Ho;Kim, Hyung-Geun;Yim, Jeong-Bin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.4 s.27
    • /
    • pp.247-252
    • /
    • 2006
  • In this study, the index for operation evaluation index for safety management system that can be facilitated as the assessment tool for system operation monitoring and operation outcome and the safety management system of shipping companies has been developed. By using this index, this study may provide the instruction or consultation for frequent facilitation by comprehensively recording the required knowledge for each operation stage for the companies that prepares the introduction of the safety management system and companies that already introduced the system to maintain and develop the system. In addition, when working on internal audit and assessing the system operation outcome, it may be facilitated as the assessment tool to contribute in continuous improvement and development. This index is consisted of 11 large categories, 35 items of medium categories and 447 small categories.

  • PDF

A Study on the Properties of the Dual-mode Plasma Torch System for Melting the Non-conductive Waste (비전도성 폐기물 용융처리를 위한 혼합형 플라즈마토치 시스템 특성 연구)

  • Moon, Young-Pyo;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.73-80
    • /
    • 2016
  • The preliminary test for the dual mode plasma torch system was carried out to explore the operation properties in advance. The dual mode plasma torch system that is able to operate in transferred, non-transferred, or dual mode is very adequate for melting the mixed wastes including nonconductive materials such as concrete, asbestos, etc. since it exploits both the high efficiency of heat transfer to the melt in transferred mode and stable operation in non-transferred mode. Also, system operation including restarting is reliable and very easy. A stationary melter with a refractory structure was designed and manufactured considering the melting behavior of slags to minimize the refractory erosion. The power supply for the dual mode plasma torch system built with high power insulated gate bipolar transistor (IGBT) modules has functions for both current control and voltage control and is sufficient to suppress the harmonics during the operation of the plasma torch. The power supply provides two different voltages for transferred operation and non-transferred. It is confirmed that the operation voltage in transferred is always higher than non-transferred. The dual mode plasma torch system was successfully developed and is under operation for a melting experiment to optimize operation data.

A Study for Efficiency of Storing Method and Vehicle Operation in Bonded Warehous at Airport (항공화물 보세창고의 화물 저장법과 이송 장비 운영의 효율성 개선)

  • Song, Kwon-Seop;Lee, Hu-Un;Chae, Jun-Jae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.1
    • /
    • pp.44-51
    • /
    • 2009
  • A bonded warehouse is the warehouse located in bonded area. It functions not only as a general warehouse but also as a place for managing the work related to import and export bonded goods. As a general warehouse, it uses the rack system to store the goods and the folk lift truck to move the unitized goods. The operation of the storing system closely related to the efficiency of space uses in a warehouse and vehicle working. Thus, vehicle performance measured in distance units in the ware-house could be used as one of the key performance measure in warehouse system. This paper focuses on the operation efficiency of the bonded warehouse which uses rack system for the storing and the folk lift truck for moving goods. The method of load allocation for balancing the rack uses and vehicle operation for maximizing efficiency are the specific concerns in this paper. The simulation study is conducted to find a policy for efficient vehicle operation based on balanced rack utilization, and the favorable result for the system operation would lead the usable proposal in vehicle operation.

Development of Optimal Operation Rule for Multipurpose Reservoirs System (다목적댐의 연계운영을 위한 최적 운영률 개발)

  • Yi, Jae-Eung
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.6
    • /
    • pp.487-497
    • /
    • 2004
  • Adding important new projects such as reservoirs which regulate a river discharge to a river system, existing operation methods should be changed considering these conditions. Since an original operation rule used for an existing system has been designed to be compatible to inputs and outputs of the existing system, the operation rule should be changed to consider the new projects. In this study, the technique of constructing new operation rules considering objectives of both old and new projects is suggested when new project is added to the river system. Reservoir operation rule using both stochastic inflow and optimization technique is developed. As a result of applying the technique to Geum river basin, the efficiency of the technique is verified.

The Operation Characteristics and Cost Analysis of an Ice Thermal Storage System (빙축열 냉방시스템의 운전특성 및 비용 분석)

  • Ahn Young Hwan;Kang Byung Ha;Kim Suk Hyun;Lee Dae Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.2
    • /
    • pp.156-164
    • /
    • 2005
  • A comparative analysis of an ice storage system has been performed on the operation cost for the four control strategies, i.e., chiller priority and chiller downstream, chiller priority and chiller upstream, storage priority and chiller upstream, storage priority and chiller downstream. Main components of the ice storage system are an ice-on-coil storage tank and a screw compressor chiller. With the simulation program, the operation cost has been evaluated from the economics of an ice storage system. It is found that the operation cost of the ice storage system is strongly dependent on the control strategy, i.e., chiller priority or storage priority, but less affected by the arrangement method, i.e., chiller upstream or chiller downstream. In case of the maximum load day, the control strategy with chiller priority and chiller upstream is supposed to obtain the reduction of operation cost. However, it is found that the control strategy with storage priority and chiller downstream is the best economical operation for most summer seasons except the maximum load day.