• Title/Summary/Keyword: System Loss Factor

Search Result 589, Processing Time 0.28 seconds

Power system analysis and power consumption breakdown for an ac PDP system (AC PDP 시스템의 전원회로 해석과 소비전력 분석)

  • Ahn, Jae-Woo;Ha, Jung-Jun;Choi, Byung-Cho
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.446-449
    • /
    • 2001
  • This paper presents the results of the power system analysis and power loss breakdown peformed on a 40-inch ac plasma display panel (PDP) TV set. The architecture and function of power system is reviewed. The power flow inside the PDP TV set is presented, and the distribution of the power loss is analyzed. It was found that the sustain driver circuit and power factor correction (PFC) circuit are the two major sources of the power loss. The results of this paper can be used as a preliminary guideline to improve the architecture and efficiency of power systems for ac PDP application systems.

  • PDF

Analysis of hydraulic system for seawater desalination plant through piping analysis program (배관 해석 프로그램을 통한 해수담수화 플랜트 수압 시스템 분석)

  • Choi, Jihyeok;Choi, Yongjun;Yang, Heungsik;Lee, Sangho;Choi, June-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.3
    • /
    • pp.221-230
    • /
    • 2020
  • In actual seawater desalination plant, the pressure loss due to frictional force of pipe is about 3~5 bar. Also, the pressure loss at pipe connection about 1~3 bar. Therefore, the total pressure loss in the pipe is expected to be about 4~8 bar, which translates into 0.111 to 0.222 kWh/㎥ of energy when converted into the Specific Energy Consumption(SEC). Reducing energy consumption is the most important factor in ensuring the economics of seawater desalination processes, but pressure loss in piping is often not considered in plant design. It is difficult to prevent pressure loss due to friction inside the pipe, but pressure loss at the pipe connection can be reduced by proper pipe design. In this study, seawater desalination plant piping analysis was performed using a commercial network program. The pressure loss and SEC for each case were calculated and compared by seawater desalination plant size.

A Study on the Concept Design of Vertical Wind Tunnel for Skydiver (고공 강하용 수직풍동의 개념설계에 관한 연구)

  • Cho, Hwan Kee
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.26 no.2
    • /
    • pp.83-90
    • /
    • 2018
  • This paper describes a case study on the design factor analysis of vertical wind tunnel for skydiver's training or experiencing of paradropping exercise in the air. The case study of vertical wind tunnel design is to provide the knowledges on effects of parameter's variation when it is applied to overall or partial duct of tunnel circuit. The analysis of design parameters based on pressure loss are produced one by one through the tunnel components from the flight chamber because the wind tunnel must satisfy the requirement of flight chamber such as flow speed, quality and quantity. Results shows the various effects of parameter variation with pressure loss in the wind tunnel circuit. Pressure loss should be based on the determination of fan and power system which can be selected from market or new design.

A Study on Electricity Market Equilibrium with Transmission Loss and Application of The Loss Factor (손실을 고려한 전력시장 균형점과 손실계수 적용에 대한 연구)

  • Kim, Sang-Hoon;Lee, Kwang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.838-839
    • /
    • 2007
  • 전력산업의 시장구조는 과점형태의 불완전 경쟁의 구조로 해석하는 것이 일반적이다. 또한 전기의 물리적 특성상 송전선로에서는 전력손실이 발생하게 되는데, 본 논문은 과점시장 모델로서 쿠르노(Cournot)모델을 사용하여 손실을 포함한 내쉬 균형점을 해석한다. 지역별 한계가격(Locational Marginal Price ; LMP)와는 달리 계통한계가격(System Marginal Price ; SMP)는 손실에 대한 가격신호를 시장에 반영하기 어렵기 때문에 손실과 함께 한계송전손실계수(Marginal Loss Factor ; MLF)를 적용하여 균형상태의 시장거래가치를 비교분석한다.

  • PDF

Heat Transfer Analysis and Cooling Design for Crude Oil Pump System (원유펌프시스템의 열전달해석 및 냉각설계)

  • Kim, Wan-Gi;Lee, Joon-Yeob;Kwon, Jung-Lock;Kim, Hea-Choen
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2017-2022
    • /
    • 2008
  • The crude oil pump system is the equipment for transporting crude oil and it consists of 3 major components, a motor and an impeller which discharge underground crude oil, a pipestack that transmits the cooling oil and power, and a cooling oil unit & junction box that provides cooling oil and electric power. When considering the system characteristics that it has to be installed at a depth of deeper than 100 m, a design technology for the efficient control of the heat occurring at a conductor and motor is necessary and it is the essential factor for ensuring system durability. In this paper, therefore, cooling oil flow has been calculated to satisfy the limit value of the system temperature by analyzing heat flow considering the related losses such as loss of conductor, contact resistor loss at the conductor connection, and operation loss of motor. And the operation temperature has been set up based on the temperature of crude oil and the heat of motor and conductor. Also, a design for cooling of crude oil pump system has been proposed by calculating the operation pressure loss and selecting the capacity of a cooling oil pump and a heat exchanger.

  • PDF

Development of Voltage Controlled Power Factor Compensation System using Slidac (슬라이닥을 이용하는 전압 제어 방식의 역률보상시스템 개발)

  • Joung, Sanghyun;Lee, Hyun-woo;Park, Young-kyun;Park, Chul-woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.8
    • /
    • pp.115-122
    • /
    • 2017
  • In this paper, we propose a novel power factor compensation system using slidac. The proposed power factor compensation system compensates the power factor by adjusting the output voltage of the slidac. In the conventional power factor compensation system using capacitor bank method, the power factor compensation error occurs depending on the load condition due to the limitation of the compensation capacitor capacity. However, the proposed system can finely change slidac output voltage applied to the capacitor, therefore power factor can be compensated up to 100% without error. We compare the proposed system with the conventional system, and confirm that the proposed system has excellent power factor compensation performance through simulations and experiments. If the proposed power factor compensation system is applied to an industrial field, a power factor compensation performance can be maximized. As a result, it is possible to reduce of electricity prices, reduce of line loss, increase of load capacity, ensure the transmission margin capacity, and reduce the amount of power generation.

AC-DC buck converter topology of high power factor with soft switching mode (소프트 스위칭 모드에 의한 고역률의 AC-DC 강압형 컨버터 토폴로지)

  • 문상필;서기영;전중함;김영철;김준홍;이현우
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.417-422
    • /
    • 1997
  • This paper proposed that a AC-DC Converter topology of high power factor with soft switching mode operates with four chopper connecting a number of parallel circuit. To improve these, a large number of soft switching topologies included a resonant circuit have been proposed. And, some simulative results on computer is included to confirm the validity of the analytical results. The partial resonant circuit makes use of a inductor using step up and a condenser of loss-less snubber. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging engergy regenerated at input power source for resonant operation. The proposed conversion system is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF

Transmission Path Analysis of Noise and Vibration in a Rotary Compressor by Statistical Energy Analysis

  • Hwang, Seon-Woong;Jeong, Weui-Bong;Yoo, Wan-Suk;Kim, Kyu-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.11
    • /
    • pp.1909-1915
    • /
    • 2004
  • The hermetic rotary compressor is one of the most important components of an air conditioning system since it has a great effect on both the performance and the noise and vibration of the system. Noise and vibration occurs due to gas pulsation during the compression process and to unbalanced dynamic force. In order to reduce noise and vibration, it is necessary to identify their sources and transmission path and effectively control them. Many approaches have been tried in order to identify the noise transmission path of a compressor. However, identification has proven to be difficult since the characteristics of compressor noise are complicated due to the interaction of the compressor parts and gas pulsation. In this study, the statistical energy analysis has been used to trace the energy flow in the compressor and to identify the transmission paths from the noise source to the exterior sound field.

A Study on the Noise and Vibration Transmission Path of Rolling Pistion Type Rotary Compressor Using SEA (통계적 에너지 해석 기법에 의한 공조용 로타리 압축기의 소음 진동 전달 경로 해석)

  • Hwang, Seon-Woong;Jeong, Hyeon-Chul;Ahn, Byung-Ha;Jeong, Weui-bong;Kim, Kyu-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.385.2-385
    • /
    • 2002
  • Hermetic rotary compressor is one of the most important components for air conditioning system since it has a great effect on both the performance and the noise and vibration of the system. Noise and vibration of rotary compressor is occurred due to gas pulsation during compression process and unbalanced dynamic force. In order to reduce noise and vibration, it is necessary to identify sources of noise and vibration and effectively control them. (omitted)

  • PDF

Noise and Vibration Analysis of Rotary Compressor by SEA (SEA에 의한 회전 압축기의 소음 진동 해석)

  • 황선웅;안병하;정의봉;김규환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.964-968
    • /
    • 2003
  • Hermetic rotary compressor is one of the most Important components for air conditioning system since it has a great effect on both the performance and the noise and vibration of He system. Noise and vibration of rotary compressor is occurred due to gas pulsation during compression process and unbalanced dynamic force. In order to reduce noise and vibration. it is necessary to identify sources of noise and vibration and effectively control then. Many approaches have been tried to identify noise sources of compressor. However, compressor noise source identification has proven to be difficult since the characteristics of compressor noise are complicated due to the interaction of the compressor parts and gas pulsation. In this work, Statistical Energy Analysis has been used to trace the energy flow in the compressor and identify transmission paths from the noise source to the sound field.

  • PDF