Heat Transfer and Friction Factors in the Channel with an Inclined Square Diamond Type Perforated Baffle (정 다이아몬드 형 구멍이 있는 배플을 가진 채널에서의 열전달과 마찰계수)

  • Oh, S.K.;Putra, A.B.K.;Ahn, S.W.
    • Journal of Power System Engineering
    • /
    • v.12 no.3
    • /
    • pp.26-31
    • /
    • 2008
  • This experimental study investigates the local heat transfer enhancement characteristics and the associated frictional head loss in the rectangular channel with a single inclined baffle. Four different types of the baffle are used. The inclined baffles have the width of 19.8 cm, the square diamond of $2.55cm{\times}2.55cm$, and the inclination angle of 5o, and number of holes of up to 9. Reynolds number is varied between 23,000 and 57,000. Results show that the heat transfer and friction factor depend significantly on the number of baffle holes and Reynolds number. The friction factor decreases with increasing Reynolds number and the number of holes on the baffle. It is found that the heat transfer performance of baffle type II(3 hole baffle) has the best values.

  • PDF

Effect of Orthogonal Spreading on the Performance of Multipath Faded Multi-Code CDMA Systems

  • Kang, Chang Soon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11B
    • /
    • pp.1540-1545
    • /
    • 2001
  • This paper is concerned with the reverse link performance of multi-code CDMA systems in multipath fading environments. The degree of orthogonality loss among multiple spreading code channels is characterized as the orthogonality factor. It depends on various system parameters including multipath power profiles of propagation channels and the number of Paths resolved at a Rake receiver. The effect of the parameters on the system performance is then investigated in terms of bit error rate and required signal quality. The results show that multipath delay power profiles dominantly affect mutual interference among multi-code channels and multipath combining gain by bandwidth expansion is not so great due to the increase of the mutual interference. Moreover, the orthogonality factor is derived as the value of between (1/m) and 1.

  • PDF

Analysis of partial resonant AC-DC converter for high power and power factor

  • Mun, Sang-Pil;Kim, Si-Lyur;Lee, ki-Youn;Hyun-Woo;Katsunori taniguchi, Katsunori-Taniguchi
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.920-927
    • /
    • 1998
  • This paper proposed that an Analysis of a partial resonant AC-DC converter for high power and power factor operates with four choppers connecting to a number of parallel circuit. To improve these, a large number of soft switching topologies included a resonant circuit have been proposed. And, some simulative results on computer are included to confirm the validity of the analytical results. The partial resonant circuit makes use of an inductor using step-down and a condenser of lose-less snubber. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in a partial resonant circuit makes charging energy regenerated at input power source for resonant operation. The proposed conversion system is deemed the most suitable for high power applications where the power switching devices are used

  • PDF

Pressure Loss and Forced Convective Heat Transfer in an Annulus Filled with Aluminum Foam (발포 알루미늄이 삽입된 환형관에서의 압력손실 및 강제대류 열전달)

  • Noh Joo-Suk;Lee Kye-Bock;Lee Chung-Gu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.9
    • /
    • pp.855-862
    • /
    • 2005
  • An experimental investigation has been carried out for aluminum foam heat sink inserted into the annulus to examine the feasibility as a heat sink for high performance forced water cooling in the annulus. The local wall temperature distribution, inlet and outlet pressures and temperatures, and heat transfer coefficients were measured for heat flux of 13.6, 18.9, 25.1, 31.4 $kw/m^2$ and Reynolds number ranged from 120 to 2000. Experimental results show that the friction factor is higher than clear annulus without aluminum foam, while the significant augmentation in Nu is obtained. This technique can be used for the compactness of the heat exchanger.

A Study on the Dielectric and Strain Properties of PNST Ceramics (PNST세라믹스의 유전 및 변형특성에 관한 연구)

  • 김진수;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.331-334
    • /
    • 1998
  • The solid solutions of the Pb(Sc$\_$0.5/Nb$\_$0.5/)$\_$0.57/Ti$\_$0.43/O$_3$ system were prepared. In the PSNT system, it had been known that two-phase region between the rhombohedral and tetragonal phases was observed between 0.425 of PT at room temperature. In this paper, Fe$_2$O$_3$-doped 0.57PSN-0.43PT composition was prepared by conventional method. The dielectric and strain properties were examined using an computerized measuring apparatus, and the resonance characteristics were measured using an impedance gain phase analyzer. We got the data of dielectric constant, dielectric loss, piezoelectric coefficient, piezoelectric voltage coefficient, frequency constant strain constant mechanical quality factor and electromechanical coupling factor.

  • PDF

The Inductor Characteristics of the PFC Converter for Wireless Power Transfer Inverter (무선전력전송 인버터 전원용 PFC 컨버터의 인덕터 특성)

  • LIM, Seongjin;KIM, Changsun
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.534-535
    • /
    • 2012
  • The characteristics of wireless power transfer is achieved at high frequencies in short range magnetic resonant wireless power transfer system. Use PFC pre-regulator for power supply of high frequency inverter. Supplied power to high power factor and high efficiency. Accordingly, the input voltage is 110V-220V. The designed of 175W Class with the output voltage of 385V. As a experiment result, maximum power factor and maximum efficiency measured 99% and 97% respectively. Therefore, in this paper, the design of a inductor which is the most important element in PFC converter for short range magnetic resonance wireless power transfer system was studied. Used an CS330125 core through the designed of 175W class. Examination results power loss was 0.2%.

  • PDF

Curcumin Inhibits Osteoclastogenesis by Decreasing Receptor Activator of Nuclear Factor-κB Ligand (RANKL) in Bone Marrow Stromal Cells

  • Oh, Sora;Kyung, Tae-Wook;Choi, Hye-Seon
    • Molecules and Cells
    • /
    • v.26 no.5
    • /
    • pp.486-489
    • /
    • 2008
  • Curcumin (diferuloylmethane), a pigment derived from turmeric, has anti-oxidant and anti-inflammatory activities. Accumulating evidence points to a biochemical link between increased oxidative stress and reduced bone density. Osteoclast formation was evaluated in co-cultures of bone marrow stromal cells (BMSC) and whole bone marrow cells (BMC). Expression of receptor activator of nuclear factor-${\kappa}B$ ligand (RANKL) was analyzed at the mRNA and protein levels. Exposure to curcumin led to dose-dependent suppression of osteoclastogenesis in the co-culture system, and to reduced expression of RANKL in $IL-1{\alpha}$-stimulated BMSCs. Addition of RANKL abolished the inhibition of osteoclastogenesis by curcumin, whereas the addition of prostaglandin $E_2$ ($PGE_2$) did not. The decreased osteoclastogenesis induced by curcumin may reduce bone loss and be of potential benefit in preventing and/or attenuating osteoporosis.

An experimental study on the heat transfer characteristics in packed bed (충전층내에서의 열전달특성에 관한 실험적 연구)

  • 신현준;양한주;오수철
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.4 no.3
    • /
    • pp.40-47
    • /
    • 1982
  • Heat transfer on packed bed is considered to be important for the effective designs of chemical reaction equipment, air conditioning system, and storage type heat exchanger, etc. Currently studies are being carried out quite actively in this field in order to increase the heat transfer efficiency. The effect of heat transfer is closely relater to materials, shapes, porosities and packing states of packed bed as well as mutual dimensional relations between particles and the container. Investigation shows that heat transfer results appear to be influenced by such parameters as fluid velocity through packed bed, mass flow, and thermal properties. It is noted that viscosity is also considered to be an important factor in this problem. In this study, effective thermal conductivities on packed bed, effects of thermal conductivity (Ke) and friction factor (Fk) according to change of porosity(.epsilon.) and Reynolds number(Reh(, and pressure loss of the fluid, are experimentally investigated. Results show that the effective thermal conductivity increases and the friction factor decreased, as against the increase of Reynolds number. But as the increase of porosity increase them both.

  • PDF

Generator Penalty Factor Calculation including Slack Bus by Reference Angle Re-Specification (위상각 기준모선의 이동에 의한 Slack 모선을 포함한 모든 발전기의 Penalty 계수 계산방법)

  • Lee, Sang-Joong;Kim, Kern-Joong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.49-51
    • /
    • 2000
  • ln this paper, a method by which penalty factors of all generators including slack bus can be directly derived is presented. With a simple re-assignment of angle reference bus to a bus where no generation exists, penalty factors for slack bus is obtained without any physical assumption. While previous Jacobian-based techniques for generator penalty factor calculation have been derived with basis upon reference bus, proposed method are not dependent on reference bus and calculated penalty factors can be substituted directly into the general ELD equation to compute the economic dispatch. Equations for system loss sensitivity, penalty factors and optimal generation allocation are solved simultaneously in normal power flow computation.

  • PDF

High power factor Buck-Boost converter with partial resonant circuit (부분공진형 고역률 승강압 컨버터)

  • Seo, Gi-Yeong;Gwon, Sun-Geol;Lee, Hyeon-U;Gwak, Dong-Geol;Bae, Seong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.126-128
    • /
    • 1993
  • Rectifiers of power conversion system are widely used condenser at input to be cheap and to be simple construction. But this method is produced harmonics of pulse at peak value of input AC voltage. The main circuit which make input current of a sinusoidal wave and improve power-factor is almost taken step-up converter. This paper is able to obtain high power-factor and efficiency because the input current is made sinusoidal wave in single phase alternating current(AC) source. Also the proposed converter is able to minimize switching loss by ZVCS(zero voltage switching and zero current switching).

  • PDF