• Title/Summary/Keyword: System Installation

Search Result 5,009, Processing Time 0.027 seconds

Dynamic Equivalents Program combined with Graphic Environments (그래픽환경을 갖춘 동태등가프로그램)

  • 임성정;윤용한;김재철
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.32-36
    • /
    • 1992
  • This paper develops the dynamic equivalents program combined with graphic user interface(GUI), to solve the stability of large power system. The p개posed method is coherency-based dynamic equivalents for transient stability studies. The program also provides with pull-down menu and Hangout help information for users. The developed dynamic equivalents program is suitable for the transient stability studies of a large power system with lots of data. The dynamic equivalents demonstrated over the New England system with 39 buses and 10 generators.

  • PDF

Computation of Current Distribution at AT Fed Electrified Railway with Mixed Grounding Systems (상이한 보호방식의 전차선로에서 고장전류 해석)

  • 정선호
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.343-347
    • /
    • 2002
  • This paper analyzed the effect of breakdown electric current and it establishes a countermeasure that objective of the place where it put when with protection method which is applied from the existing electric railroad power supply system and where the protection method which is applied in the newly electrified system. Will reach and in order to attain simulation it did a actual power supply system and it analyzed that result.

  • PDF

New Vibration Suppression Control of 2-Mass System using $H_{\infty}$ Filter (2관성계의 $H_{\infty}$ 필터를 이용한 새로운 전동억제제어)

  • 김진수;유상봉
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.339-342
    • /
    • 2002
  • In the industrial motor drive system which is composed of a motor and load connected with a flexible shaft, a torsional vibration is often generated because of the elastic elements in torque transmission. To solve this problem H$_{\infty}$ controller was designed. In this paper, H$_{\infty}$ control of 2-mass system using H$_{\infty}$ filter for compensating shaft torque is proposed. Pole-zero maps show the validity of proposed controller.

  • PDF

A Study On Development Train Reach Spare Time Indicate Device At The Railway Level Crossing (철도건널목 열차도달 잔여시간 표시장치 개발 연구)

  • 박기범;장우진;최규형
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.117-124
    • /
    • 2002
  • Fixed distance control system at the railway level crossing have some problem. The problem is especially serious for high speed or low speed train. Therefore present developed device is fixed time control system. But fixed time control system haven't indicate device when train reach at the railway level crossing on alarm. This paper' result in study for train reach spare time indicate device.

  • PDF

Synchronous Generator Digital Exciter System PSS Control (동기발전기 디지털 여자 시스템 PSS 제어)

  • 홍현문
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.144-148
    • /
    • 2004
  • This thesis also proposes an applied digital exciter control system for a synchronized generator using a digitally PSS controller. Experiment results show that the digital control system manifests excellent control performance compared to analog control systems. It has also been confirmed that it is easy for the modern control theory to implement digital control.

A Study on the Overcurrent Relay Coordination in Power Systems (전력계통에서의 과전류계전기 보호협조에 관한 연구)

  • Choi, Hong-Kyoo;Kim, Kyung-Chul;Oh, Jung-Suk;Kim, Byung-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.351-358
    • /
    • 2004
  • When fault occur in power systems, the protective relay plays a roles of protecting power system according to its setting values. There, it is very important that the protective relay have high selectivity performance in power system by correct setting the relays. This paper analyzed protect device protect cooperation or Transient stability and apply to Overcurrent relay in the real power system operation environment by using EDSA Program.

  • PDF

A Re-Configuration Genetic Algorithm for Distribution Systems (배전계통에서 유전적 알고리즘을 이용한 접속변경순서 결정방법)

  • Choi, Dai-Seub
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.381-383
    • /
    • 2004
  • Recently, sectionalizing switches have been coming to be operated by remote control through the distribution SCADA system. However, the problem of determining the optimal switching sequence is a combinatorial optimization problem, and is quite difficult to solve. Hence, it is imperative to develop practically applicable solution algorithms create a new arbitral distribution system configuration from an initial configuration, and some of these algorithms do not show a load transfer sequence to reach the objective system.

  • PDF

The Phase Shift and Phase Error Analysis in the Shearographic System (Shearographic system에서의 위상천이 및 위상오차 분석)

  • Kim, Soo-Gil;Ko, Myung-Sook
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.143-145
    • /
    • 2005
  • We present the method to obtain four speckle patterns with relative phase shift of ${\pi}/2$ passive devices such as wave plate and polarizer, and calculate the phase at each point of the speckle pattern in shearographic system using Wollaston pin And, we analyzed the phase error caused by wave plates used in the proposed method by Jones matrix.

  • PDF

Load Forecasting Of Power System (전력계통의 전력수요예측)

  • Ahn, Dae-Hoon;Lee, Sang-Joong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.78-83
    • /
    • 2005
  • This article suggests an improved method for more accurate load forecast for the power system. The authors propose an improved load forecast expert system based on expert's know-how. A field manual for the load forecast can be made using proposed method. The authors expect this article could give a guidance to those who wish to be load forecast expert.

  • PDF

Accuracy improvement of FBG temperature sensor system for usage in electric power systems (전력 시스템 보호를 위한 광섬유 격자 온도센서의 정밀도 개선)

  • Lee, Hyun-Wook;Lee, Jun-Ho;Song, Min-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.421-425
    • /
    • 2005
  • A distributed FBG temperature sensor system was constructed for the use in protection of electric power system. A F-P wavelength tunable filter is used converting temperature-induced wavelength variations to temporal peak locations. We used Gaussian line-fitted algorithm to alleviate the error caused by quantization and electrical noises. The experimental results showed much better accuracy than the raw peak-detection scheme.

  • PDF