• 제목/요약/키워드: System Factor

검색결과 12,750건 처리시간 0.037초

요인분석을 통한 IoT 기반 고령자용 교통안전 보행자 시스템 (An IoT-based Traffic Safety Pedestrian System for the Elderly by Factor Analysis)

  • 이경민;인치호
    • 한국ITS학회 논문지
    • /
    • 제20권1호
    • /
    • pp.1-9
    • /
    • 2021
  • 본 논문은 안전한 보행 경로 정보를 제공하는 IoT 기반 고령자용 교통안전 보행자 시스템을 제안한다. 제안하는 시스템은 고령자 안전 변수의 요인분석을 수행하고 분석결과를 사용하여 고령자에게 최적의 경로를 제공한다. 이 시스템의 성능을 검증하기 위해 고령 보행자 경로에 대한 성능 측정을 실험하였습니다. 그 결과 모바일 내비게이션보다 안전 성능이 더 나은 성능 확인하였다.

태양광발전시스템의 장기운전에 의한 성능변화 분석 (Performance Analysis of long term operation for photovoltaic system)

  • 김의환;김정삼
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.110.1-110.1
    • /
    • 2011
  • This study analyzed the performance of long term operation photovoltaic system The 50 kWp grid connected photovoltaic system which was installed at KEPRI site in 1999 has been operated more than 12 years. In order to acquire long term operation characteristics of medium size photovoltaic system, the operation test data related on power generation electricity and capacity factor of 50 kWp system, which have been collected since 1999, were analysed. From the analysing results, 57.7 MWh in annual power generation electricity of 50 kWp photovoltaic system in 1999 has been decreased 49.1 MWh in 2005 and reached 38.0 MWh in 2010. In addition to, the capacity factor of 50 kWp photovoltaic system also showed 13.2 % in 1999, 11.2% in 2005 and finally reached 8.8% in 2011. The operation test data showed a trend of decreasing of generation electricity and capacity factor during the 12 years operation time and we guessed that was caused by solar cell performance degradation and decreasing of PCS system efficiency.

  • PDF

군 병원정보시스템 구현의 중요성공요인 분석 연구 (A Study on Critical Success Factors in Implementing Military Hospital Information Systems)

  • 김준우;김승기;전동진
    • Asia pacific journal of information systems
    • /
    • 제15권1호
    • /
    • pp.81-113
    • /
    • 2005
  • IT has affected the hospital management via information systems and multimedia systems such as hospital information systems(HIS) and Order Communication System(OCS). A large number of researches have been done on the topic of success factors of information systems implementation, but a few on the topics of hospital information systems. Thus in this study, the success factors of the military hospital information systems implementation was analysed. To this end, a number of previous researches were reviewed and about 71 items of success factors were deduced. For doing empirical analysis, a questionnaire with 71 items was prepared and sent to proper organizations. The statistical analysis such as factor analysis was applied to about 400 of them returned. The six success factors and 20 sub success factors were resulted from factor analysis. The six success factors include systems management factor, technology and organization factor, the efficiency of IT department factor, technology application factor, outsourcing factor and environment factors. This study finds the outsourcing and environment factors are very important factors as much as other success factors which previously were mentioned.

발전비용의 부하역률 감도와 종합비용을 활용한 효과적인 역률개선 방안 연구 (A Study on the Effective Enhancement of the Load Power Factor Using the Load Power Factor Sensitivity of Generation Cost and Integrated Costs)

  • 이병하;오민혁;김정훈;심건보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.284-286
    • /
    • 2003
  • The low load power factor causes various problems such as the Increase of the power loss and the voltage instability. The demand of reactive power increases continuously with the growth of active power and the restructuring of electric power companies makes the integrated management of ractive power troublesome, from which the systematic control of load power factor is required. In this paper, the load power factor sensitivity of the generation cost and integrated costs are used for determining the locations and capacities of reactive power compensation devices effectively and for enhancing the load power factor appropriately. It is shown through the application to a small-scale power system that the system power factor can be enhanced effectively and appropriately using the load power factor sensitivity and integrated costs.

  • PDF

산업용 드론을 이용한 잣수확용 해머링 시스템의 구조해석 (Structural Analysis of Hammering System for Pine Cone Harvest using Industrial Drone)

  • 김기홍;배대원;최원식
    • 한국산업융합학회 논문집
    • /
    • 제26권2_2호
    • /
    • pp.285-291
    • /
    • 2023
  • In this paper, in order to secure the safety and productivity of pine cone harvest, modeling and structural analysis of the hammering system for pine cone harvest drone that can easily access pine cone of Pinus koraiensis and collide with them to harvest them was performed. It calculate the equivalent stress for the structure of the hammering system and the yield strength of the applied material by applying the shear force of the stalk at which the pine cone is separated from the branch, and it is to verify the safety of the structure and propose an optimal design through appropriate factor of safety and design change. The shear force of the stalk at which the pine cone was separated from the branch was 468 N, and was applied to both ends of the hammering system. The yield strength of SS400 steel used in the hammering system is 245 ㎫, and the design change and structural analysis were performed so that the Von Mises stress could be less than 122.5 ㎫ by applying the factor of safety of 2.0 or more. As a result of the structural analysis of the frist modeling, the Von Mises stress was 220.3 ㎫, the factor of safety was 1.12, and the stress was concentrated in the screw fastening holes. As a result of the design change of the screw fastening holes, the Von Mises stress was 169.4 ㎫, the factor of safety was 1.45, and the stress was concentrated on the side part. As a result of the design change by changing screw fastening holes and adding ribs, the Von Mises stress was 121.6 ㎫, and the factor of safety was 2.02. The safety of the hammering system was secured with an optimal design with little change in mass. There was no deformation or damage as a result of experimenting on pine cone harvest by manufacturing the hammering system with an optimal design.

7구역진단기의 Factor AA의 유형분석과 임상지표와의 상관성 연구 (A Study on the Correlation between the Patterns of Factor AA in a 7-zone-diagnostic System and the Clinical Parameters)

  • 유정석;이휘용;이장원;장소영;차정호;이진석;송범용
    • Journal of Acupuncture Research
    • /
    • 제24권6호
    • /
    • pp.159-170
    • /
    • 2007
  • Objectives : The 7-zone-diagnostic system is a diagnostic device to predetermine bodily locations by measuring the energy of a living body. This study was to investigate the relation between the different patterns of Factor AA in a 7-zone-diagnostic system and clinical parameters. The purpose of this study is to relate Korean traditional medicine and western medicine using the data from the 7-zone-diagnostic system and the clinical parameters. Methods : This study was carried out with the data from some clinical parameters. We made two groups according to the Factor AA patterns of VEGA-DFM 722, the 7-zone-diagnostic system The Factor AA patterns of Group A named hyperenergy is all the red bar graphs that arehigher than the normal range. The Factor AA patterns of Group B named hypoenergy is all the red bar graphs that are lower than the normal range. After the data from clinical parameters corresponding with conditions of each group were selected, the data from clinical parameters among each group was analyzed statistically. Results : The values of Weight, GOT, r-GTP, Uric acid and BMI of Group A are higher than those of Group B. The values of Sodium and Phosphorus of Group A are lower than those of Group B. Conclusions : To conclude, it is thought that Group A has a heat-excess type but Group B has colddeficient type.

  • PDF

주성분분석에 의한 $A_{2}O$공법의 처리성 평가 (Treatability Evaluation of $A_{2}O$ System by Principal Component Analysis)

  • 김복현;이재형;이수환;윤조희
    • 한국환경보건학회지
    • /
    • 제18권2호
    • /
    • pp.67-74
    • /
    • 1992
  • The lab-scale biological A$_{2}$O system was applied from treating piggery wastewater highly polluted organic material which nitrogen and phosphorous are much contained relatively in conversion with other wastewater. The objective of this study was to investigate the effect of variance parameters on the treatability of this system according to operation conditions. An obtained experimental data were analysed by using principal component analysis (PCA) method. The results are summarized as follows: 1. From Varimax rotated factor loading in raw wastewater, variance of factor 1 was 36.8% and cumulative percentage of variance from factor 1 to factor 4 was 81.5% and of these was related to BOD, TKN and BOD loading. 2. In anaerobic process, variance of factor 1 was 33.5% and cumulative percentage of variance from factor I to factor 4 was 81.8% and of these was related to PO$_{4}$-P, BOD, DO and Temperature. 3. In anoxic process, variance of factor 1 was 30.1% and cumulative percentage of variance from factor i to factor 4 was 84.3% and of these was related to pH, DO, TKN and temperature. 4. In aerobic process, variance of factor 1 was 43.8% and cumulative percentage of variance from factor 1 to factor 4 was 81.5% and of these was highly related to DO, PO$_{4}$-P and BOD. 5. It was better to be operated below 0.30 kg/kg$\cdot$day F/M ratio to keep over 90% of BOD and SS, 80% of TKN, and 60% of PO$_{4}$-P in treatment efficiencies. 6. Treatment efficiencies was over 93% of BOD and SS, 81% of TKN and 60% of PO$_{4}$-P at over 20$^{\circ}$C, respectively.

  • PDF

Harmonics Reduction in Load control and Management system

  • Thueksathit, W.;Tipsuwanporn, V.;Hemawanit, P.;Gulpanich, S.;Srisuwan, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2283-2286
    • /
    • 2003
  • This paper presents conservation of electrical energy in building with harmonics analysis and compensation which occur in electrical system. We use load controlling and management system in order to adjust load factor of system.The maximum demand limiting and controlling are used ,then the system can acquire the prediction and compare it to the maximum demand set point.The electrical signal analysis based on FFT technique. The harmonics are compensated by using harmonic filters.This system consists computer which works as controller, processor , analysis and database unit together with digital power meter in form of multidrop network through serial communication via RS-485.The load control system uses PLC to control load via serial communication RS-485. The A/D converter is used for sampling the electrical signals via parallel port of computer.The harmonic filters are controlled by a computer.The data of measurement such as voltage, current, power, power factor, total harmonic distortion, energy, etc., can be saved as database and analysis. The load factor is adjusted by limiting and controlling maximum demand. The load factor adjustment can reduce the cost of electric consumption and energy generation together with harmonics compensation in order to increase high efficiency of electrical system.

  • PDF

중규모 태양광발전시스템 장기 실증운전 평가 (The long-term operating evaluation of the grid connected photovoltaic system)

  • 김의환;안교상;임희천
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.14-19
    • /
    • 2009
  • The 50 kWp grid connected photovoltaic system which was installed at KEPRI site in 1999 has been operated more than 10 years. In order to acquire long term operation characteristics of medium size photovoltaic system, the operation test data related on power generation electricity and capacity factor of 50 kWp system, which have been collected since 1999, were analysed. From the analysing results, 57.7 MWh in annual power generation electricity of 50 kWp photovoltaic system in 1999 has been decreased 49.1 MWh in 2005 and reached 41.9 MWh in 2008. In addition to, the capacity factor of 50 kWp photovoltaic system also showed 13.2 % in 1999, 11.2% in 2005 and finally reached 9.6% in 2008. The operation test data showed a trend of decreasing of generation electricity and capacity factor during the 10 years operation time and we guessed that was caused by solar cell performance degradation and decreasing of PCS system efficiency.

Neural Stem Cell Differentiation Using Microfluidic Device-Generated Growth Factor Gradient

  • Kim, Ji Hyeon;Sim, Jiyeon;Kim, Hyun-Jung
    • Biomolecules & Therapeutics
    • /
    • 제26권4호
    • /
    • pp.380-388
    • /
    • 2018
  • Neural stem cells (NSCs) have the ability to self-renew and differentiate into multiple nervous system cell types. During embryonic development, the concentrations of soluble biological molecules have a critical role in controlling cell proliferation, migration, differentiation and apoptosis. In an effort to find optimal culture conditions for the generation of desired cell types in vitro, we used a microfluidic chip-generated growth factor gradient system. In the current study, NSCs in the microfluidic device remained healthy during the entire period of cell culture, and proliferated and differentiated in response to the concentration gradient of growth factors (epithermal growth factor and basic fibroblast growth factor). We also showed that overexpression of ASCL1 in NSCs increased neuronal differentiation depending on the concentration gradient of growth factors generated in the microfluidic gradient chip. The microfluidic system allowed us to study concentration-dependent effects of growth factors within a single device, while a traditional system requires multiple independent cultures using fixed growth factor concentrations. Our study suggests that the microfluidic gradient-generating chip is a powerful tool for determining the optimal culture conditions.