• 제목/요약/키워드: System Condensation Technique

검색결과 65건 처리시간 0.028초

Dynamic Condensation Method를 이용한 차량-교량계의 동적해석 (Dynamic Analysis of Vehicle-Bridge System by the Dynamic Condensation Method)

  • 한재익;이경동
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제2권2호
    • /
    • pp.177-184
    • /
    • 1998
  • The equation of motion on the vehicle-bridge system is established as the simultaneous equations which are combined the equation of vehicle and bridge by the interaction elements. A vehicle element is modeled as lumped masses supported by springs and dashpots, and a bridge element with pavement roughness is modeled as beam elements. An interaction element is defined to consist of a bridge element and the suspension units of the vehicle resting on the element. By the dynamic condensation method, the degrees of the freedom are eliminated, and compared with all the degrees of freedom on the bridge, the efforts of calculation is decreased. Thus, although a very small computational error is occured, the present technique appears to be computationally more efficient. It is particularly suitable for the simulation of bridges with a series of vehicles moving on the deck.

  • PDF

The transient and frequency response analysis using the multi-level system condensation in the large-scaled structural dynamic problem

  • Baek, Sungmin;Cho, Maenghyo
    • Structural Engineering and Mechanics
    • /
    • 제38권4호
    • /
    • pp.429-441
    • /
    • 2011
  • In large-scale problem, a huge size of computational resources is needed for a reliable solution which represents the detailed description of dynamic behavior. Recently, eigenvalue reduction schemes have been considered as important technique to resolve computational resource problems. In addition, the efforts to advance an efficiency of reduction scheme leads to the development of the multi-level system condensation (MLSC) which is initially based on the two-level condensation scheme (TLCS). This scheme was proposed for approximating the lower eigenmodes which represent the global behavior of the structures through the element-level energy estimation. The MLSC combines the multi-level sub-structuring scheme with the previous TLCS for enhancement of efficiency which is related to computer memory and computing time. The present study focuses on the implementation of the MLSC on the direct time response analysis and the frequency response analysis of structural dynamic problems. For the transient time response analysis, the MLSC is combined with the Newmark's time integration scheme. Numerical examples demonstrate the efficiency of the proposed method.

초음속 노즐에서 발생하는 응축충격파 진동의 피동제어 (Passive Control of the Condensation Shock Wave Oscillation in a Supersonic Nozzle)

  • 백승철;권순범;김희동
    • 대한기계학회논문집B
    • /
    • 제26권7호
    • /
    • pp.951-958
    • /
    • 2002
  • Rapid expansion of a moist air or a stream through a supersonic nozzle often leads to non-equilibrium condensation shock wave, causing a considerable energy loss in flow field. Depending on amount of latent heat released due to non-equilibrium condensation, the flow is highly unstable or a periodical oscillation accompanying the condensation shock wave in the nozzle. The unsteadiness of the condensation shock wave is always associated with several kinds of instabilities as well as noise and vibration of flow devices. In the current study, a passive control technique using a porous wall with a plenum cavity underneath is applied for the purpose of alleviation of the condensation shock oscillations in a transonic nozzle. A droplet growth equation is coupled with two-dimensional Navier-Stokes equation system. Computations are carried out using a third-order MUSCL type TVD finite-difference scheme with a second-order fractional time step. An experiment using an indraft wind tunnel is made to validate the present computational results. The results show that the oscillations of the condensation shock wave are completely suppressed by the current passive control method.

이슬 결로점 기반 수배전반 결로 방지 장치 제작 (System Implementation for Dew Condensation Prevention of Distributing Boards based on the Dew Point)

  • 김태명;지석근;김영완
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.645-650
    • /
    • 2018
  • 본 논문에서는 옥내 외에 설치 운영되는 수배전반의 결로 현상을 방지하는 IT 기반 자동 온습도 제어기를 설계하고 제작하였다. 이슬 결로점 온도가 실내공간의 습도와 온도로부터 산출되고, 이슬 결로점 온도와 결로 부위의 온도를 비교하여 수배전반의 결로 현상을 방지할 수 있는 시설이 순차적으로 제어 동작되도록 구현하였다. 아울러 원격지의 수배전반의 결로 기반 제어기 동작 상태를 모니터링 할 수 있는 원격 모니터링 장치를 LoRa 무선통신 방식을 사용하여 구현하였다. 제어기와 원격 모니터링 장치를 설치 운영하여 전송되는 데이터의 정확성과 결로 기반 제어기 동작상태의 안정성을 확인하였다. 본 제어 장치는 수배전반 이외에 결로가 발생되는 장비에 설치되어 결로를 방지할 수 있는 장치로 용이하게 활용될 수 있다.

Microseal®을 이용한 근관충전법의 근관폐쇄능력 평가 (EVALUATION OF THE SEALING ABILITY OF Microseal® OBTURATION TECHNIQUE)

  • 오태석;유현미;황혜경
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.682-689
    • /
    • 1998
  • The purpose of this study was to evaluate the sealing ability of the Microseal$^{(R)}$, which was new obturation system made by Tycom company, U.S.A. Forty-five extracted single-rooted human teeth were resected at cemento-enamel junction and divided three groups. All canals were prepared using Profile system, and then each group was obturated by lateral condensation technique (group 1), vertical condensation technique (group 2) and Microseal$^{(R)}$ condensation technique (group 3) with root canal sealer. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$ and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were resected horizontally at 1 mm (level I), 2 mm (level II), 3 mm (level III) from the anatomical root apex using low speed microtome and examined with Image analyzer (IBASR, Zeiss co., Germany.) at ${\times}25$ magnification. The gab between the canal wall and the filling material, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was expressed percentage by calculating the ratio of the area of the resin to the total area of the canal and was analyzed statistically (one-way ANOVA). The results were as follows; 1. The mean ratio of leakage (%) was 6.46% at group 1, 3.06% at group 2, 11.27% at group 3. 2. When evaluating the ratio of leakage at the three levels, there was level I> level II> level III in all groups. Especially, the difference between level I and level III was statistically significant (p<0.05). 3. When evaluating the ratio of leakage at the three groups, there was group 3> group 1> group 2 at all levels. Especially the difference between group 2 and group 3 was statistically significant (p<0.05).

  • PDF

준능동 TMD를 이용한 메가골조구조물의 진동제어 (Vibration Control of Mega Frame Structures using a Semi-active Tuned Mass Damper)

  • 김현수;이동근
    • 한국지진공학회논문집
    • /
    • 제11권2호
    • /
    • pp.57-68
    • /
    • 2007
  • 메가골조시스템은 사용되는 구조재료를 절약하면서도 구조물의 강성을 효과적으로 높일 수 있는 장점 때문에 고층건물의 설계에 많이 사용되고 있다. 이러한 메가골조시스템이 주로 적용되고 있는 초고층건물의 구조설계에서는 횡하중에 대한 거주자의 불안감을 최소화시키는 것이 주요한 관심사중의 하나이다. 따라서 본 연구에서는 메가골조구조물의 사용성을 향상시키기 위한 방법으로 일반적인 수동 TMD의 제어성능을 개선한 준능동 TMD(STMD)를 사용하였다. 이를 위하여 TMD에서 일반적으로 사용되고 있는 수동감쇠기 대신 준능동 MR 감쇠기를 사용하여 STMD를 구성하였다. 메가골조구조물의 일반적인 유한요소해석모델은 매우 많은 수의 자유도로 구성되어 있기 때문에 원형모델을 사용하여 STMD의 제어성능을 검토하는 것은 현실적으로 불가능하다. 따라서 메가골조구조물의 동적 거동을 정확하게 표현할 수 있는 최소한의 자유도를 가진 응축모델을 행렬응축기법을 이용하여 제안하였다. 또한 일반적인 행렬응축기법의 효율성을 향상시키기 위하여 메가골조구조물의 특성을 활용한 다단계 행렬응축기법을 제안하였다. 본 연구에서 제안된 응축모델을 사용한 제어의 효율성과 정확성 및 메가골조구조물에 대한 STMD의 제어성능을 예제해석을 통하여 검증하였다.

Plugger 삽입깊이가 근관내 gutta-percha 점유면적에 미치는 영향 (Influence of plugger penetration depth on the area of the canal space occupied by gutta-percha)

  • 이영미;소호영;김영경;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제31권1호
    • /
    • pp.66-71
    • /
    • 2006
  • Continuous Wave 가압법으로 근관충전시 plugger 삽입 깊이에 따른 근관내 gutta-percha 비율을 평가하고자 40개의 발거치아 근관을 0.06 경사도 40번 크기의 $ProFile^{(R)}$로 근관을 형성하고 세 군에서는 plugger 삽입깊이를 근단 3, 5 또는 7 mm로 하여 System $B^{TM}$를 이용하여 Continuous Wave 가압법으로 충전하였고, 한 군에서는 대조군으로서 측방가압법으로 근관을 충전하였다. 충전된 근관은 치근단 1, 2 및 3mm 수준에서 횡절단하여 근관내 gutta-percha 면적비를 계산하고 일원변량분석법을 이용하여 통계분석 하였다. 모든 절단수준에서, Continuous Wave 가압법으로 충전한 군 사이에서는 plugger의 삽입깊이가 깊을수록 높은 gut-ta-percha 면적비를 나타내었고, 측방가압법으로 충전한 군이 plugger의 삽입깊이를 7 mm로 충전한 군보다 높은 gut-ta-percha 면적비를 나타내었다 (p<0.05).

초음파(超音波) 근관충진법(根管充眞法)의 폐쇄효과(閉鎖效果)에 관(關)한 분광광도계(分光光度界) 측정(測定) (SPECTROPHOTOMETRIC ANALYSIS ON THE SEALING EFFECT OF ULTRASONIC OBTURATION OF THE ROOT CANAL)

  • 김양락
    • Restorative Dentistry and Endodontics
    • /
    • 제15권2호
    • /
    • pp.46-57
    • /
    • 1990
  • 초음파진동과 열을 이용하는 초음파 금관충전법의 근관페쇄효과를 연구하기 위하여 색소회복법(dye recovery method)에 기초한 분광광도계 측정법으로 근단공 누출정도를 정량적으로 측정하였다. 발거된 상하악 중절치 및 측절치에서 치관을 절제한 120개의 치근에 재래식 방법으로 근관형성을 하고 측방가압법, McSpadden 근관충전법 및 초음파 근관충전법으로 근관을 충전한 후 $37^{\circ}C$ 항온기내에서 2% methylene blue에 10일간 침지시킨 다음 색소용출을 위해 60% 질산에 용해시키고 색소회복법에 의한 분광광도계 측정을 시행한 후 검량선에 의한 누출량을 산출하여 통계학적으로 상호비교 하였다. 초음파 근관충전법의 색소침투량은 sealer 사용유무와는 관계없이 측방가압충전법과 유사하게 나타났고 McSpadden 충전법은 측방가압법보다 색소 침투량이 더 많이 나타났다. 측방가압풍전법과 초음파 근관충전법에서는 sealer를 병용시 근관폐쇄효과는 양호하였으나, McSpadden 근관충전법에서는 sealer 사용유무에 따른 근관폐쇄효파는 별 차이가 없었다.

  • PDF

벽식구조물의 효율적인 연직진동해석 (Efficient Floor Vibration Analysis in A Shear Wall Building Structure)

  • 김현수;이동근
    • 한국지진공학회논문집
    • /
    • 제8권6호통권40호
    • /
    • pp.55-66
    • /
    • 2004
  • 현재 국내에서는 벽과 바닥판만으로 이루어진 벽식 구조형식의 아파트 건물이 많이 건설되고 있다. 아파트와 같은 주거구조물에서는 다양한 진동원에 의하여 진동이 발생하고 이러한 진동은 벽과 바닥판을 통하여 이웃한 세대 및 위, 아래층 세대로 전달되게 된다. 벽식구조물의 진동해석을 정확하게 수행하기 위해서는 벽과 바닥판을 많은 수의 유한요소로 세분한 모델을 사용하는 것이 필요하다. 그러나 아파트와 같은 벽식구조물 전체를 수많은 유한요소로 세분하여 모형화하면 막대한 해석시간과 컴퓨터 메모리가 필요하게 된다. 따라서 본 연구에서는 상당히 줄어든 해석시간과 컴퓨터 메모리를 사용하여 정확한 해석결과를 얻기 위하여 행렬응축기법으로 벽과 바닥판에 수직인 자유도만 가지는 효율적인 진동해석 모델을 제안한다. 벽식구조물에서 벽과 바닥에 수직인 자유도만을 남기고 나머지 자유도를 행렬응축기법을 통하여 한꺼번에 소거를 한다면 행렬응축과정에서 상당히 많은 양의 시간이 소요된다. 따라서 본 연구에서는 벽이나 바닥판에 수직인 자유도만을 가진 수퍼요소를 생성한 후 이를 조합하여 한 층을 나타내는 부분구조를 만들고 최종적으로 부분구조를 조합하여 전체 구조물을 구성하는 모형화 기법을 제안하였다. 제안된 해석기법의 정확성과 효율성을 검증하기 위하여 3층 및 5층의 벽식구조물을 예제구조물로 사용하여 동적해석을 수행하였다. 예제해석 결과 제안된 해석방법의 결과는 절점당 6개의 자유도를 모두 사용한 해석모델의 결과와 비슷한 정확성을 보이면서도 소요되는 해석시간과 컴퓨터 메모리를 대폭 줄일 수 있었다.

Influence of plugger penetration depth on the area of the canal space occupied by gutta-percha

  • Lee, Young-Mi;Park, Jeong-Won;Kim, Sung-Kyo
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.557-557
    • /
    • 2003
  • I. Objectives The purpose of this study was to evaluate the ratio of gutta-percha area in the canal after canal obturation with Continuous Wave of Condensation Technique with varying depths of plugger penetration. II. Materials and Methods Forty extracted human teeth with single canal were divided into four group of ten teeth each. Root canals were prepared up to size 40 of 0.06 taper with $ProFile^{\circledR}$. After drying, canals of three groups were filled with Continuous Wave of Condensation Technique with System $B^{TM}$ and different plugger penetration depths of 3, 5, and 7mm from the apex.(omitted)

  • PDF