• Title/Summary/Keyword: System Capacity

Search Result 8,716, Processing Time 0.034 seconds

An Evaluation for Progressive Collapse Resisting Capacity of a 80F RC Flat Plate for Sustainable Super Tall Building (지속가능한 초고층 건물을 위한 80층 RC 플랫 플레이트 건물의 연쇄붕괴 저항성능 평가)

  • Seo, Dae-Won;Kim, Hae-Jin;Shin, Sung Woo
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.151-157
    • /
    • 2010
  • This study is connected with evaluation of the progressive collapse resisting capacity for sustainable RC super tall building design. As the progressive collapse is not considered in current design codes in Korea, differences between linear static and dynamic analysis based on the GSA guidelines was analyzed for better evaluation, and the analysis model of flat plate system was determined. Finally, the progressive collapse resisting capacity was evaluated for structural system of super tall building. According to this study, the results by linear dynamic analysis were underestimated than the results by linear static analysis. Thus, the dynamic coefficient value of 2 provides conservative approach. The Effective Beam Width's model, currently used in field, is useful for the analysis about lateral force, but this model does not consider the effect of load redistribution by the slab. Hence, finite element analysis considering slab element will be needed for progressive collapse resisting capacity of the flat plate system. Finally, analysis model of 80-story building designed based on KBC(Korea Building Code) shows the weakness against progressive collapse because the DCR value is over 2. Thus, the countermeasure for alternative loading path such as installment of spandrel beam and reinforcements around slab is required to prevent the progressive collapse.

Battery Monitoring System for High Capacity Uninterruptible Power Supply (대용량 무정전 전원장치를 위한 배터리 모니터링 시스템)

  • Lee, Hyung-Kyu;Kim, Gi-Taek
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.580-585
    • /
    • 2019
  • Batteries are being used in ESS, electric vehicles and uninterruptible power backup systems. Lead-acid batteries are the most used batteries for high capacity power back up equipment due to their high reliability and low price advantages. It is very important to estimate the chargeable capacity(SoH), and many algorithms were proposed to estimate the internal resistance of the battery. In this paper, the Battery Monitoring System(BMS) for high capacity uninterruptible power supply for IDC is proposed. A simple algorithm for estimating internal resistance was proposed. An computational block diagram of the proposed signal processing algorithm and BMS system configuration of CPU and analog circuit were shown. The proposed method was proved useful by presenting data examples of application to actual IDC sites.

Effect of Reversed Austenite on the Damping Capacity of Austenitic Stainless Steel (오스테나이트계 스테인리스강의 감쇠능에 미치는 역변태 오스테나이트의 영향)

  • Kim, Young-Hwa;Sung, Ji-Hyun;Kang, Chang-Yong
    • Journal of Power System Engineering
    • /
    • v.19 no.1
    • /
    • pp.70-75
    • /
    • 2015
  • The influence of reversed austenite on the damping capacity in austenitic stainless steel with two phase of martensite and reversed austenite was investigated. The two phases of deformation induced martensite and reversed austenite was obtained by an reverse annealing treatment at $500^{\circ}C{\sim}700^{\circ}C$ for various time after 70% cold rolling. With an increase of the reverse annealing treatment temperature and time, volume fraction of reversed austenite was rapidly increased. With an increase of volume fraction of reveresd austenite, damping capacity was rapidly increased. At same volume of reveresd austenite, damping capacity of reversed austenite obtained by reverse annealing treatment at $700^{\circ}C$ for various time was higher then reveresd austenite obtained by reverse annealing treatment at $500^{\circ}C{\sim}700^{\circ}C$ for 10min. Thus, the damping capacity was affected greatly by reversed austenite obtained by annealing treatment at $700^{\circ}C$ for various time.

A Study on Optimal Capacity of Energy Storage System in Renewable Energy Based Micorgrids (신재생에너지가 연계된 마이크로그리드에서 에너지 저장장치의 최적 용량 선정에 관한 연구)

  • Kim, Wook-Won;Lee, Nam-Hyung;Lee, Yun-Sung;Shin, Je-Seok;Kim, Jin-O
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.529-533
    • /
    • 2012
  • By introducing RPS(Renewable Portfolio Standard) for reduction of greenhouse gas, Renewable energy sources have becoming widespread gradually. However, Renewable energy sources, such as wind power and PV are difficult to control the output and they have intermittent characteristics of the output. These characteristics would cause some problems when it is connected in the power system. In order to solve these problems, Energy Storage Systems(ESS) are considered to use. Although there are many different storage devices, the utilization of Secondary Battery is the one of the best ways to stabilize an output fluctuation of RES because of its fast responsibility. For that reason, it would better fit a large-capacity of Secondary battery for stabilization. However, batteries cannot be installed with a large capacity blindly because of its expensive cost. So to select proper capacity of the battery is an important consideration. This paper presented a methodology for the optimal capacity and operation of ESS in microgrids.

  • PDF

An Experimental Study on the Performance Characteristics of Hot-gas and Liquid Bypass Heat Pump Systems for Capacity Modulation (고온가스 및 액체 바이패스 적용 용량가변 히트펌프의 성능특성에 관한 실험적 연구)

  • Ahn, Jae Hwan;Joo, Youngju;Yoon, Won Jae;Kang, Hoon;Kim, Yongchan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.137-142
    • /
    • 2013
  • A small air-conditioner or chiller for a constant temperature bath normally uses a constant speed compressor. The constant speed compressor is relatively inexpensive, but it uses on/off control for capacity modulation. The on/off control has several disadvantages, specifically energy loss and large temperature fluctuation. Continuous operation with a bypass system can be an alternative to on/off control, for capacity modulation. In this study, a heat pump system having a hot-gas bypass and a liquid bypass was adopted. The performance of the bypass-type heat pump was measured, by varying the bypass valve opening. The differences of the COP between the hot-gas bypass and the liquid bypass, in the cooling and heating operations, were within 2% and 1%, respectively. The liquid bypass showed a wider range of capacity control in the cooling operation but the hot-gas bypass showed a wider range of capacity control in the heating operation.

A Study on Establishing Operation Mathematical Model for Optimum Capacity Estimation of the ESS Applications for each in the Nationwide Perspective (국가적 관점에서 용도별 ESS 적정용량 산정을 위한 운전수리모델 수립에 대한 연구)

  • Kim, Jung-Hoon;Youn, Seok-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.969-978
    • /
    • 2016
  • Around the world are increasing the demand for ESS. Currently, the domestic is expected to benefit by operating ESS. In the domestic, it is expected to benefit from operations of the installed ESS because of the introduction of ESS less capacity. However ESS capacity to the maximum profit occurs is unknown. ESS is different from the charge-discharge characteristics and the reserve to replace, depending on the application. Therefore, it should be established in accordance with the ESS optimal capacity according to the purpose used because it can maximize the quality and efficiency of the electric energy. To the ESS optimal capacity estimation by the purpose used, It should compare the investment cost caused by ESS facility installation and operation cost caused by operating ESS. In this paper, the operation mathematical model for estimating marginal operation costs established. In operation mathematical model, operating cost is considered fuel cost and no-load cost start-up cost. Because no-load cost and start-up cost are not related to cost and power plant output, there are expressed an integer variable costs as a step function.

Optimal Number of Base Station Antennas and Users in MF Based Multiuser Massive MIMO Systems (MF 기반 다중 사용자 Massive MIMO 시스템의 최적 기지국 안테나 수 및 사용자 수 분석)

  • Jung, Minchae;Choi, Sooyong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.8
    • /
    • pp.724-732
    • /
    • 2013
  • In this paper, we analyze a performance of multiuser massive multiple-input and multiple-output (MIMO) system. We derive the ergodic cell capacity based on a downlink frame structure and analyze the ergodic cell capacity with respect to the number of base station (BS) antennas and the number of users. This paper shows that the ergodic cell capacity is a concave function with respect to the number of BS antennas and the number of users, and also derives the optimal numbers of BS antennas and users for the maximum cell capacity. The simulation results verify the derived analyses and show that the derived numbers of BS antennas and users provide the maximum cell capacity.

Effect of Reverse Transformation on the Damping Capacity of High Manganease Austenitic Stainless Steel (고 Mn 오스테나이트계 스테인리스강의 감쇠능에 미치는 역변태의 영향)

  • Kang, C.Y.
    • Journal of Power System Engineering
    • /
    • v.16 no.4
    • /
    • pp.60-65
    • /
    • 2012
  • This study was carried out to investigate the effect of reverse transformation on the damping capacity in high manganese austenitic stainless steel. ${\alpha}^{\prime}$-martensite was formed with the specific direction and surface relief by deformation. Over 95% of the austenite phase was transformed to deformation-induced ${\alpha}^{\prime}$-martensite by 70% cold rolling. Reverse transformation became rapid above an annealing temperature of $550^{\circ}C$, but there was no significant transformation above $700^{\circ}C$. In addition, with increasing annealing time at $700^{\circ}C$, reverse transformation was induced rapidly, but the transformation was almost completed at 10 min. Damping capacity was increased up to $700^{\circ}C$, and than unchanged with the increasing annealing temperature. Damping capacity increased steeply with an increasing reverse treatment time up to 10min, whereas there were no significant change with a treatment time of more than 10 min. Damping capacity increased with an increasing the reversed austenite and was strongly affected by reversed austenite.

The Effect of grain size on the damping capacity of Fe-26Mn-2Al alloy (Fe-26Mn-2Al 합금의 진동 감쇠능에 미치는 결정립 크기의 영향)

  • Kang, C.Y.;Eom, J.H.;Kim, H.J.;Sung, J.H.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.115-120
    • /
    • 2007
  • The effect of grain size on the damping capacity of Fe-26Mn-2Al alloy studied in this paper has been investigated after changing the microstructure by cold rolling and changing grain size. Micro structures in Fe-26Mn-2Al at room temperature consist of a large quantity of austenite and a small quantity of ${\varepsilon}\;and\;{\alpha}'$ martensite. And ${\varepsilon}\;and\;{\alpha}'$ martensite was increased by increasing the degree of cold rolling. The content of deformation induced martensite was increased with increasing the degree of cold rolling. Damping capacity was linearly increased with increasing ${\varepsilon}$ martensite content, which suggests that stacking faults and ${\varepsilon}$ martensite variant boundaries are the principle damping sources. With increasing the grain size in Fe-26Mn-2Al alloy, the damping capacity was increased due to increasing the volume fraction of ${\varepsilon}$ martensite by decrement in stability of austenite phase. With decreasing the grain size, the content of deformation induced martensite was decreased and the damping capacity was decreased.

  • PDF

Throughput Capacity of a Wireless Multi-hop Relay Network using Cognitive Radio (Cognitive Radio 무선 다중홉 릴레이 네트워크의 Throughput 용량)

  • Hassan, Md. Imrul;Song, Ju-Bin;Kim, Young-Il
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.5
    • /
    • pp.33-39
    • /
    • 2007
  • In this paper, we investigate the throughput capacity of a multi-hop relay with cognitive radio (CR) enabled relay stations (RS). We suggest a TDMA/FDMA based frame structure where RSs dynamically select unused channels to communicate with the base station (BS) using CR techniques to analyze the throughput capacity. We develop the throughput capacity model for the proposed system based on utilization factor. The analytical results based on those equations show significant improvement in throughput capacity for CR enabled multi-hop relay system.