• Title/Summary/Keyword: System Architecture Design

Search Result 3,802, Processing Time 0.031 seconds

Evaluation of Steel Tube Connection in Precast Concrete Double Wall System (프리캐스트 콘크리트 더블월 시스템의 각형 강관 연결부 성능평가 )

  • Yujae Seo;Hyunjin Ju
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.2
    • /
    • pp.25-32
    • /
    • 2023
  • In this study, a double wall system is introduced, which was invented to simplify the complicated manufacturing process of the existing precast concrete (PC) double wall systems and to remove defects such as laitance that may occur during the production of concrete panels. An experimental study was conducted to investigate the tensile resisting capacity of the steel tube which is embedded in the precast concrete panel to keep the spacing between PC panels and to prevent damage of the PC panels during transportation and casting concrete onsite. The experiment was planned to determine the detail of effective steel tube connection considering the steel plate treatment method according to the formation of the opening, the presence of embedded concrete, and the reinforcement welding for additional dowel action as key variables. As a result, the ultimate tensile strength increased by 20-30% compared to the control specimen (ST) except for the steel tube specimen (ST_CP) which has steel plates bent inward at the end part of the steel tube. Since the specimen (ST_CON) filled with concrete inside the control specimen has no additional process and cost for the steel tube connections compared to the control specimen during the production of the developed double wall system, it is determined to be the appropriate detail of steel tube connection.

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.

A Study for Improving in Greening System and Method to Revitalize Wall-planting (벽면녹화 활성화를 위한 제도적 개선방안 및 조성방향에 관한 연구)

  • Han, Seung-Ho;Kim, Sun-Hae
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.2
    • /
    • pp.59-71
    • /
    • 2006
  • Due to the rapid process of industrialization the cities of Korea confront changes of climate, destructions of the habitate and decrease of the green. Recently Seoul and other local governments have implemented policies and projects to improve the environmental surroundings. In reality, however, those policies and projects face difficulties in the course of implementation. The fact that there are no concrete regulations and specific legal procedures turns out to be one of the main difficulties. The aim of this study is to present specific plans and methods of wall-planting and to provide basic guidelines for the future direction of wall-planting and offer ideas of facilitating wall-planting. This study is based on questionnaires from specialists of landscape architecture through individual interviews and/or e-mails. The questionnaire is consisted of following 4 sections. 1. Show the experts current regulations and/or legal procedures and ask them improvements and suggestions. 2. Ask them choose matters of the highest priority by using Ricardo's diagram method. 3. Ask them to make a graded list in terms of the location and method of wall-planting. 4. Study the maketability of the wall-planting products currently in circulation. The city of Seoul and the Ministry of Environment recommend that trellis and/or planting inducement structures be installed on the building wall by regulation. The specialists responded to the questionnaire advocate that green wall without trellis should be allowed as green zone. Therefore regulations concerning the wall-planting should be determined specifically according to the characteristics of individual plants and walls. It has been urged that legal aid and social support must be reinforced to establish rules dealing with wall-planting. The respondents also point out that significant cutting down of the tax is far more effective in accelerating the wall-green instead of administrative support. The highest priority in terms of planting has been given to sound-proof wall, retaining wall and building wall. Concerning the maketability of the wall-planting products, panel products are recommended for early-planting and building planting. It has been suggested that the research and study of new materials and species be done in advance.

Design of Partial Discharge Pattern Classifier of Softmax Neural Networks Based on K-means Clustering : Comparative Studies and Analysis of Classifier Architecture (K-means 클러스터링 기반 소프트맥스 신경회로망 부분방전 패턴분류의 설계 : 분류기 구조의 비교연구 및 해석)

  • Jeong, Byeong-Jin;Oh, Sung-Kwun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.114-123
    • /
    • 2018
  • This paper concerns a design and learning method of softmax function neural networks based on K-means clustering. The partial discharge data Information is preliminarily processed through simulation using an Epoxy Mica Coupling sensor and an internal Phase Resolved Partial Discharge Analysis algorithm. The obtained information is processed according to the characteristics of the pattern using a Motor Insulation Monitoring System program. At this time, the processed data are total 4 types that void discharge, corona discharge, surface discharge and slot discharge. The partial discharge data with high dimensional input variables are secondarily processed by principal component analysis method and reduced with keeping the characteristics of pattern as low dimensional input variables. And therefore, the pattern classifier processing speed exhibits improved effects. In addition, in the process of extracting the partial discharge data through the MIMS program, the magnitude of amplitude is divided into the maximum value and the average value, and two pattern characteristics are set and compared and analyzed. In the first half of the proposed partial discharge pattern classifier, the input and hidden layers are classified by using the K-means clustering method and the output of the hidden layer is obtained. In the latter part, the cross entropy error function is used for parameter learning between the hidden layer and the output layer. The final output layer is output as a normalized probability value between 0 and 1 using the softmax function. The advantage of using the softmax function is that it allows access and application of multiple class problems and stochastic interpretation. First of all, there is an advantage that one output value affects the remaining output value and its accompanying learning is accelerated. Also, to solve the overfitting problem, L2-normalization is applied. To prove the superiority of the proposed pattern classifier, we compare and analyze the classification rate with conventional radial basis function neural networks.

Case study of Civil Engineering BIM Projects: Perspective of Korean Public Owners (토목분야 BIM 적용 사례 분석을 통한 발주자 관점에서의 BIM 발전 전략)

  • Kim, Changyoon;Moon, Hyoun-Seok;Nah, Heu-Suk;Kim, Jin-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7430-7437
    • /
    • 2014
  • Owing to the increase in large and complex construction projects, the design paradigm of architecture and civil engineering projects has changed from 2D CAD to 3D CAD. For this reason, to meet the strong requirements of project contractors, various efforts have been made to adopt a Building Information Modeling (BIM) technology for effective construction management. On the other hand, compared to architectural projects, only a few civil engineering project cases have been conducted in the perspective of public contractors. This is because the characteristics of civil project contractors and the negative pursuit of adopting BIM technology due to the lack of a current BIM system and technologies. Recently, positive changes in adopting BIM technology for public projects were anticipated by public owners, such as the Public Procurement Service and the Ministry of Land, Infrastructure and Transport. In this regard, this study analyzed the current BIM technology status of public owners in Korea to adopt the BIM policies and guidelines of the Korean government. Strategies for adopting BIM technologies for Korean public owners are also discussed based on an analysis of civil engineering BIM project cases.

The Actual Condition investigation of Residental Environment of Urban Life-Type Housing Regarding Crime Prevention Through Environmental Design -Focused on Five Single Households in studio-type housings in Gwanak-gu, Seoul Urban Life-Type Housing- (도시형생활주택의 범죄예방환경설계 측면에서 본 주거환경 실태조사에 관한 연구 - 서울시 관악구 원룸형 주택 1인가구 5개를 중심으로-)

  • Jung, Yoon-Hye;Lee, You-Mi;Lee, Youn-Jae
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.39-50
    • /
    • 2016
  • Purpose: The purpose of this study is to be performed with studio-type housings among urban life-type housings to investigate the physical characteristic and crime-related factors of studios from the viewpoint of the basic principles of crime prevention through environmental design (CPTED). Method: Eight CPTED guidelines available in Korea were reviewed to select 20 planing factors for actual condition investigation. Five single households in studio-type housings in Gwanak-gu, Seoul, were chosen according to the subject screening criteria to perform the actual condition investigation. Results: First, a lighting plan around a building for natural surveillance should consider the building location, relation with the front road, and surrounding facilities. In a building of a piloti structure, the parking lot and the building gate should be arranged in a manner that enables natural surveillance. Second, the shape of the corridors in studio-type housings should be considered to plan the installation of a lighting at the door of each household, the installation of a viewer window at the door of each household, and the arrangement of the elevator. Third, to support access control, an access control system having the function of video and voice communication is recommended to be installed at the building gate. Criteria for the type of security windows and the floors on which security windows should be installed, and the regulations about the CCTV installation inside and outside the building should be prepared. Fourth, to enhance territoriality in parking lots, ground patterns, parking lot gate, and signs may be installed. Fifth, in view of effective utilization and maintenance, lighting facilities should be installed to increase the usability of ground parking lots, and relevant installation criteria should be prepared regarding the type, number, and brightness of the lightings.

Evolutionally optimized Fuzzy Polynomial Neural Networks Based on Fuzzy Relation and Genetic Algorithms: Analysis and Design (퍼지관계와 유전자 알고리즘에 기반한 진화론적 최적 퍼지다항식 뉴럴네트워크: 해석과 설계)

  • Park, Byoung-Jun;Lee, Dong-Yoon;Oh, Sung-Kwun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.15 no.2
    • /
    • pp.236-244
    • /
    • 2005
  • In this study, we introduce a new topology of Fuzzy Polynomial Neural Networks(FPNN) that is based on fuzzy relation and evolutionally optimized Multi-Layer Perceptron, discuss a comprehensive design methodology and carry out a series of numeric experiments. The construction of the evolutionally optimized FPNN(EFPNN) exploits fundamental technologies of Computational Intelligence. The architecture of the resulting EFPNN results from a synergistic usage of the genetic optimization-driven hybrid system generated by combining rule-based Fuzzy Neural Networks(FNN) with polynomial neural networks(PNN). FNN contributes to the formation of the premise part of the overall rule-based structure of the EFPNN. The consequence part of the EFPNN is designed using PNN. As the consequence part of the EFPNN, the development of the genetically optimized PNN(gPNN) dwells on two general optimization mechanism: the structural optimization is realized via GAs whereas in case of the parametric optimization we proceed with a standard least square method-based learning. To evaluate the performance of the EFPNN, the models are experimented with the use of several representative numerical examples. A comparative analysis shows that the proposed EFPNN are models with higher accuracy as well as more superb predictive capability than other intelligent models presented previously.

Fabric Mapping and Placement of Field Programmable Stateful Logic Array (Field Programmable Stateful Logic Array 패브릭 매핑 및 배치)

  • Kim, Kyosun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.209-218
    • /
    • 2012
  • Recently, the Field Programmable Stateful Logic Array (FPSLA) was proposed as one of the most promising system integration technologies which will extend the life of the Moore's law. This work is the first proposal of the FPSLA design automation flow, and the approaches to logic synthesis, synchronization, physical mapping, and automatic placement of the FPSLA designs. The synchronization at each gate for pipelining determines the x-coordinates of cells, and reduces the placement to 1-dimensional problems. The objective function and its gradients for the non-linear optimization of the net length and placement density have been remodeled for the reduced global placement problem. Also, a recursive algorithm has been proposed to legalize the placement by relaxing the density overflow of bipartite bin groups in a top-down hierarchical fashion. The proposed model and algorithm are implemented, and validated by applying them to the ACM/SIGDA benchmark designs. The output state of a gate in an FPSLA needs to be duplicated so that each fanout gate can be connected to a dedicated copy. This property has been taken into account by merging the duplicated nets into a hyperedge, and then, splitting the hyperedge into edges as the optimization progresses. This yields additional 18.4% of the cell count reduction in the most dense logic stage. The practicality of the FPSLA can be further enhanced primarily by incorporating into the logic synthesis the constraint to avoid the concentrated fains of gates on some logic stages. In addition, an efficient algorithm needs to be devised for the routing problem which is based on a complicated graph. The graph models the nanowire crossbar which is trimmed to be embedded into the FPSLA fabric, and therefore, asymmetric. These CAD tools can be used to evaluate the fabric efficiency during the architecture enhancement as well as automate the design.

A Study On the Design of a Floating Point Unit for MPEG-2 AAC Decoder (MPEG-2 AAC 복호기를 위한 부동소수점유닛 설계에 관한 연구)

  • 구대성;김필중;김종빈
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.4
    • /
    • pp.355-355
    • /
    • 2002
  • In this paper, we designed a FPU(floating point unit) that it is very important and requires of high density when digital audio is designed. Almost audio system must support the multi-channel and required for high quality. A floating point arithmetic function in MPEG-2 AAC that implemented by hardware is able to realtime decoding when DSP realization. The reason is that MPEG-2 AAC is compatible to the Audio field of MPEG-4 and afterwards. We designed a FPU by hardware to increase the speed of a floating point unit with much calculation part in the MPEG-2 AAC Decoder. A FPU is composed of a multiplier and an adder. A multiplier used the Radix-4 Booth algorithm and an adder adopted 1's complement method for speed up. A form of a floating point unit has 8bit of exponent part and 24bit of mantissa. It's compatible with the IEEE single precision format and adopted a pipeline architecture to increase the speed of a processor. All of sub blocks are based on ISO/IEC 13818-7 standard. The algorithm is tested by C language and the design does by use of VHDL(VHSIC Hardware Description Language). The maximum operation speed is 23.2MHz and the stable operation speed is 19MHz.

Design and Implementation of the Chronic Disease Management Platform based on Personal Health Records (개인건강기록 기반 만성질환 관리 플랫폼의 설계 및 구현)

  • Song, Je-Min;Lee, Yong-Jun;Nam, Kwang-Woo
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.17 no.1
    • /
    • pp.47-62
    • /
    • 2012
  • To propagate clinical disease management service, there should be built a ecosystem where service developers, service providers, device suppliers closely cooperate for u-Health platform. However, most u-Health platform is difficult to build an effective ecosystem due to the lack of secure and effective PHR(Personal Health Record) management, the lack of personalized and intelligent service, difficulties of N-screen service. To solve these problems we suggest the CDMP(Chronic Disease Management Platform) architecture. The CDMP is a software platform that provides the core functions to develop the chronic disease management services and performs a hub function for the link and integration rbetween various services and systems. CDMP is SOA based platform that enables a provision of reusability, expansibility and it provides open API where everybody can share information, contents and services easily. CDMP supports the multi platform system foN-screen service and the self management functions via SNS. In this paper, we design and implement the CDMP including PHR service based on hybrid data model for privacy preservation. Experiment results prove the effectiveness of hybrid model-based PHR service.