• Title/Summary/Keyword: System Air Conditioner

Search Result 408, Processing Time 0.027 seconds

Modelling of System Air-Conditioner for Dynamic Simulation (동적시뮬레이션을 위한 시스템 멀티에어컨의 모델링)

  • Lee, Yoon-Jong;Kim, Chan-Jung;Moon, Je-Myung;Kim, Cheol-Woo;Seo, Hyeong-Joon;Kim, Gyoung-Rok;Shin, Haeng-Cho;Hong, Hi-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.328-333
    • /
    • 2007
  • The purpose of this study is modelling of system air-conditioner for TRNSYS. System air-conditioner is operated by a variable capacity compressor and accommodated by multiple evaporators. By reason of these feature, realizing performance of system air-conditioner for TRNSYS was incomplete. In this study performance data of system air-conditioner and control logics are used to make system air-conditioner module for TRNSYS. Performance data contains total capacity, power input and capacity index of system air-conditioner. The simulation was carried out in a mode of temperature level control using TRNSYS 16. The simulation shows that the system air-conditioner model operate variable capacity and can compute capacity index and power input of system.

  • PDF

Estimation of the Noise Caused by the System Air Conditioner and its Improvement (시스템 에어컨에 의한 실내 소음 평가 및 개선 설계)

  • Lee, Jea-Won;Joo, Jae-Man;Oh, Sang-Kyong;Song, Yong-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.862-865
    • /
    • 2004
  • The system air conditioner has an outdoor unit and a number of indoor units, which connected by several long pipes. In comparison with building HAVC system, the system air conditioner doesn't need lots of facilities, such as control of room, cooling tower, etc. At the beginning stage for the market of the system air conditioner, its main application was a school which size is small to use the building HAVC and large to use home air conditioning system, such as PAC (package air conditioner), RAC (room air conditioner). Therefore, because of the advantages of the system air conditioner mentioned above, the market is expanded rapidly. Since it is difficult to evaluate the noise caused by the system air conditioner because it has to be implemented before the finish of construction, the prediction or estimation of the noise by using CAE technology should be very important. In this research, using a commercial code, RAYNOISE, the noise is estimated to improve the design of building.

  • PDF

A Study of Failure Examples for Refrigerant Gas Leakage in Automotive Air Conditioner System (자동차 에어컨 냉매 가스 누설에 대한 고장사례 고찰)

  • Lee, Il Kwon;Kook, Chang Ho;Moon, Hak Hoon;You, Chang Bae
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.10-15
    • /
    • 2016
  • This paper is to analyze and study the failure examples of refrigerant gas in automotive air conditioner. The first example, the air conditioner compressor continually operated that the refrigerant was leaked in air conditioner system. By lubrication shortage, the piston was partially sticked on cylinder of air conditioner compressor inner part. This was caused the phenomenon of engine operation trouble by load increasing with engine rpm variation during engine running. The second example, it sought the fact that the air conditioner refrigerant gas was leaked from air conditioner compressor to condenser high pressure pipe toward rear air conditioner checking with the lines of air conditioner. The third example, the refrigerant gas of air conditioner found that was leaked imperceptible from condenser inner by crack that was generated on the fins of air conditioner condenser. Therefore, the air conditioner system that maintain the air conditioner by decreasing the in-car temperature must meticulously manage to not leak the air conditioner refrigerant gas.

Effect of Charged Refrigerant Amount on Operating Characteristics and Development of Detecting Program for System Air-Conditioner (시스템에어컨의 냉매충전량에 따른 사이클 운전특성 및 냉매량 판독 프로그램 개발)

  • Tae, Sang-Jin;Kim, Hun-Mo;Mun, Je-Myeong;Kim, Jong-Yeop;Gwon, Hyeong-Jin;Jo, Geum-Nam
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.427-432
    • /
    • 2005
  • This study developed a program for detecting charged refrigerant amount in system air-conditioner. System air-conditioner is an air-conditioning system with multiple indoor units. Due to the complexity of the system, it is more difficult to detect the refrigerant amount charged in system air-conditioner than in a general single air-conditioner. Experiments were performed for 6 HP outdoor units with 3 indoor units in a psychrometric calorimeter. The experimental amount of charged refrigerant were ranged from 60% to 140% with 10% increasement. Fuzzy algorithm were emploeed for detecting the charged refrigerant amount in a system air-conditioner. The experimental data were used for curve fitting for general ranges for indoor and outdoor temperature conditions. membership function were determined for whole ranges of experimentally measured data and rulebase were defined for each amount of refrigerant charge. Developed program successfully predicted the measured data within 10% resolution range.

  • PDF

The Effects of Air Conditioner Noise on Classroom Acoustics (교실 음향에 대한 에어컨 소음의 영향)

  • Kim, Su-Yeon;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.176-179
    • /
    • 2005
  • A case-study in classroom acoustics was conducted and the effects of two types(system air conditioner and packaged air conditioner) of air conditioner were investigated. Acoustical measurements were made in two different classrooms. Each classroom has different acoustics showing sound quality of air conditioner. Mental concentration test was conducted to evaluate the effects of air conditioner noise with different sound presure level(dBA). Speech intelligibility test was also planed with adopting Korean phonetic balanced words.

  • PDF

A Study on the Application of Thermoelectric Module in the Air Conditioner System Using Automotive (차량용 냉방시스템에의 열전소자 적용에 관한 연구)

  • Kim, S.H.
    • Journal of Power System Engineering
    • /
    • v.12 no.4
    • /
    • pp.32-38
    • /
    • 2008
  • The improvement of cooling ability for the air conditioner is the most efficient method of application of its system. Therefore, this study has been investigated the improvement of cooling ability for the air conditioner using automotive by attached of a thermoelectric module. According to the result of test, capacity of the thermoelectric module make temperature range from $-75^{\circ}C$ to $+300^{\circ}C$ possible to cooling and exothermic. In addtion to, the reduction effect of energy revealed and the effect of liquid hammer remained with safety by attached the thermoelectric module. It was found that the air conditioner system by attached thermoelectric module have better cooling ability than the air conditioner system of existing vehicle.

  • PDF

Parametric Study on Performance of an Automobile Air Conditioner (차량용 에어컨의 성능에 미치는 인자에 관한 연구)

  • Park, Y.C.;Kwon, K.R.
    • Journal of Power System Engineering
    • /
    • v.6 no.4
    • /
    • pp.16-22
    • /
    • 2002
  • This study was conducted to find performance evaluation method for automobile air conditioner. Experimental facilities were constructed to simulate wide range of operating condition for the automobile air conditioner. Compressor speed was controled by variable speed electric motor and the power was measured through torque transducer and tachometer was used to measure compressor speed. Parametric studies were conducted in this study, to figure out effect of environment variables on the performance of the automobile air conditioner. The environmental variables are inlet air temperature, relative humidity and air flow rate for the evaporator and inlet air temperature and air flow rate for the condenser. Compressor speed is also changed. The results of this study shows that air flow rate of the evaporator is more sensitive to the performance of the automobile air conditioner than the other variables. However relative humidity of the inlet air of the evaporator strongly affects capacity rather that COP.

  • PDF

Development of the TRNSYS Simulation Modules for System Air-Conditioner and Its' Verification (TRNSYS 시뮬레이션을 통한 시스템 에어컨의 구현과 타당성 검증)

  • Ki, Hyun-Seung;Hong, In-Pyo;Park, Jun-Won;Kang, Ki-Nam;Song, Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.315-322
    • /
    • 2012
  • In these days, importance of HVAC system in office building is steadily growing in terms of thermal comfort and energy savings. As a energy efficient heating and cooling system, system air-conditioner which can be controlled distinctly and has a high COP is more widely adopted nowadays. However, the features and advantages of system air-conditioner were not reported well because system air-conditioner did not describe yet by conventional simulation methods such as TRNSYS, e-Quest, Energyplus, etc. In this study, by using the TRNSYS program which is able to show module implementation and building energy consumption analysis, system air-conditioner module will be proposed and validated through comparison between the simulation results and measurement results.

Program Development for Detecting Charged Refrigerant Amount in System Air-Conditioner using Fuzzy Algorithm (퍼지 알고리즘을 이용한 시스템 에어컨의 냉매충전량 감지 프로그램 개발)

  • Tae S. J.;Choi C. S.;Kim H. M.;Cho K.;Moon J. M.;Kim J. Y.;Kwon H. J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.172-179
    • /
    • 2006
  • This study developed a program for detecting charged refrigerant amount in system air-conditioner. System air-conditioner is an air-conditioning system with multiple indoor units. Due to the complexity of the system, it is more difficult to detect the refrigerant amount charged in the system air-conditioner than in a general single air-conditioner. Experiments were performed for a 6 HP outdoor unit with 3 indoor units in a psychrometric calorimeter. The experimental amount of the charged refrigerant was ranged from $60\%\;to\;140\%\;with\;10\%$ increasement. Fuzzy algorithm was employed for detecting the charged refrigerant amount in the system air-conditioner. The experimental data were used for curve-fitting for the general ranges of indoor and outdoor temperature conditions. Membership function was determined for the whole ranges of experimentally measured data and rule-bases were defined for each charged refrigerant amount. Developed program successfully predicted the measured data within $10\%$ resolution range.

Comparison of the PMV and $CO_2$ Concentration, Energy Consumption Characteristics of Central Air-Conditioning System and System Air-Conditioner with Ventilation System for Large Space (중형공간에서 중앙공조방식과 시스템에어컨 방식에 따른 PMV와 $CO_2$농도, 에너지소비량 비교)

  • Sung, Sang-Chul;Noh, Kwang-Chul;Chin, Sim-Won;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.298-303
    • /
    • 2008
  • PMV, $CO_2$ and the energy consumption performance were numerically investigated in a large space with air-conditioning systems of four type. The numerical results showed that thermal comforts in the occupied zone are nearly similar in three systems except 3-way wall type system air-conditioner with ventilation system installed 2.2m height from the bottom. In case of 3-way wall type system air-conditioner the energy consumption for cooling loads was reduced about 25.5% compared to other air-conditioning systems. From the viewpoint of IAQ, it was turned out that system air-conditioner with ventilation system became worse about 20% compared to central air-conditioning systems for cooling load. The PMV, $CO_2$ concentration and energy consumption of all systems for heating loads were similar in a large space considered.

  • PDF